• 제목/요약/키워드: Ventilation Performance

검색결과 621건 처리시간 0.029초

공동주택의 환기방식별 다수실 환기 성능에 관한 연구 - 다수실의 환기경로 및 환기효율 - (Study on Ventilation Performance of Multi-room in Apartment - Airflow and Ventilation Effectiveness in Multi-room -)

  • 권경우;조시진;최의성;박준석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.399-404
    • /
    • 2006
  • Heating and cooling load of ventilation is a very important part of building energy saving. Improving ventilation effectiveness can save building energy consume and supply fresh air to indoor efficiently. So this study measured mulity-zone aiflow and ventilation effectiveness according to ventilation types. Result of measurement show that ventilation effectiveness is depends on ventilation system design rather than ventilation types.

  • PDF

분배계통에 따른 지하주차장 환기설비 성능의 예측

  • 김경환;이재헌;오명도;김종필
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.982-992
    • /
    • 2001
  • In this paper, the performance of ventilation equipments in enclosed parking garages were investigated for several air distribution systems by numerical method. Air change effectiveness of the non-mixing system was 0.42. It meant that more supply air as much as the design supply air was needed to maintain good indoor air quality. In the high speed nozzle ventilating system which is most expensive one, air change effectiveness was 0.54. Therefore this system satisfied to ventilation design. In the jet fan ventilating systems, air change effectiveness for jet fan ventilating system-A with 18 jet fans and jet fan ventilating system-B with 6 jet fans in circulation mixing arrangement were 0.565 and 0.42 respectively. Jet fan ventilating system-C with 6 jet fans in transport mixing arrangement was 0.535. Jet fan ventilating system-A and jet fan ventilating system-C met the ventilation design. But velocity in jet fan ventilating system-A was over 2.0m/s which is inappropriate in human comfort. Therefore this system is not proper to ventilation. Jet fan ventilating system-C was the optimum one for enclosed parking garages among 5 systems examined in this paper.

  • PDF

다연동 플라스틱 온실의 자연환기성능 평가 (Evaluation of Natural Ventilation Performance for Multi-span Plastic Greenhouses)

  • 남상운;김영식;서동욱
    • 생물환경조절학회지
    • /
    • 제22권1호
    • /
    • pp.7-12
    • /
    • 2013
  • 측고, 연동수, 측창의 유무 및 천창의 위치에 따른 다연동 온실의 환기성능을 평가하기 위하여 다양한 유형의 연동 플라스틱 온실을 대상으로 실제 농가의 재배현장에서 환경계측 실험을 수행하였다. 실험 대상 온실은 모두 토마토를 수경재배하고 있는 농가였으며, 열수지 방법으로 환기율을 비교 분석하였다. 측고가 4m인 온실은 측고가 2m인 온실에 비하여 22% 정도의 환기율이 증가하는 것으로 나타났다. 9연동 온실은 5연동 온실에 비하여 17% 정도의 환기율이 감소하는 것으로 나타났다. 9연동 온실에서 측창이 없는 경우에는 측창을 설치한 경우 보다 환기율이 1/3 정도로 낮게 나타났다. 전체적으로 다연동 온실의 환기성능은 측고가 높을수록 좋고, 연동수가 많을수록 떨어지며, 측창이 없으면 현저하게 저하하는 것으로 나타났다. 또한, 측고가 높고 천창을 용마루에 설치한 경우의 환기성능이 가장 우수한 것으로 나타났다. 따라서 다연동 온실의 자연환기 성능을 극대화하기 위해서는 온실의 측고는 높이고, 지붕 환기창의 위치는 곡부가 아니라 용마루에 설치하며, 측창을 반드시 설치하고, 연동수는 10연동 내외로 제한하는 등의 구조개선이 필요하다.

재생증발식 냉방기를 이용한 환기 냉방시스템의 성능해석 (Performance Simulation of a Ventilation System Adopting a Regenerative Evaporative Cooler)

  • 장영수;이대영
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.8-15
    • /
    • 2011
  • Cooling load reduction was analysed of a ventilation system adopting a regenerative evaporative cooler. The regenerative evaporative cooler is a kind of indirect evaporative cooler which cools the air down to its inlet dewpoint temperature in principle without change in the humidity ratio. The regenerative evaporative cooler was found able to cool the ventilation air to $18{\sim}21^{\circ}C$ when the outdoor condition ranges $25{\sim}35^{\circ}C$ and 0.01~0.02 kg/kg. When the outdoor humidity ratio is lower than 0.018 kg/kg, the regenerative evaporative cooler was found to provide cooling performance enough to compensate the ventilation load completely and to supply additional cooling as well. Energy simulation during the summer was carried out for a typical office building with the ventilation system using the regenerative evaporative cooler. The results showed that the seasonal cooling load can be reduced by about 40% by applying the regenerative evaporative cooler as a ventilation conditioner. The reduction was found to increase as the outdoor temperature increases and the outdoor humidity ratio decreases.

패시브환기외피의 단면온도분포 및 열회수량에 관한 수치해석적 연구 (A Numerical Study on Sectional Temperature Distribution and Heat Recovery Amount of Passive Ventilation Skin)

  • 이태철;손유남;윤성환
    • 설비공학논문집
    • /
    • 제24권10호
    • /
    • pp.705-710
    • /
    • 2012
  • This study aims to analyse changes of inner temperature of PVS(Passive ventilation skin) and heat recovery when it has ventilation of air through PVS using numerical simulation in the winter condition. Results are as follows. 1) In case of the air inflows through PVS, change of inner temperature of PVS is lower than in case of the air flows inner space to out space, by dynamic insulation. 2) It was identified that the temperature gradient of PVS were bigger by increases of ventilation amount. To reduce ventilation load, heat transfer efficiency at the inner side of PVS is important and what performance of insulation at the inner side of PVS secure helps to improve heat performance of all PVS.

제3종 하이브리드 환기시스템을 적용한 공동주택의 환기성능 예측 (A Prediction of Hybrid Ventilation System Performance in Apartment House)

  • 황지현;오창용;김무현
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.541-548
    • /
    • 2006
  • A hybrid ventilation system was introduced to predict the ventilation performance of the apartments. This ventilation system was composed of the natural supply-air inlet and the forced exhaust-air outlet. Analysis was conducted by CFD technique and was performed on three ventilating flow rates; 30, 60, $120m^3/h$. As the results, residents feel comfortable thermally for $60m^3/h$. In the case of $120m^3/h$, however, residents feel uncomfortable both thermally and in air currents. In this study the energy saving for space heating is also an important factor. In the case of whole region with $180m^3/h$, residents feel comfortable at each region of the model apartment. It is shown that this hybrid ventilation system is possible method for the apartment house.

벽체매립형 폐열회수 환기시스템의 열회수 성능 향상에 관한 실험적 연구 (An Experimental Study on Performance Improvement for Exhaust Heat Recovery Ventilation System in a Lightweight Wall)

  • 정민호;오병길
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.61-66
    • /
    • 2014
  • Exhaust heat recovery ventilation systems conserve energy through enthalpy recovery between air intake and exhaust, and they are being increasingly used. An exhaust heat recovery ventilation system can be installed in the ceiling of a balcony or emergency evacuation space. However, in the case of fire, the emergency evacuation space has to by law remain as empty space, and therefore, a ventilation system can't be installed in an emergency evacuation space. Therefore, the need for a proper installation space for a ventilation system is emphasized. In this study, to install a heat recovery ventilation system in a lightweight wall, a heat exchanger was assembled of thickness below 140 mm. The efficiency of heat recovery was analyzed through performance experiment, in the case of the cooling and heating mode. The heat recovery efficiency increases when the surface area is increased, by using closer channel spacing in the heat exchanger, or by increasing the size of the heat exchanger.

제트홴의 이격거리에 따른 터널내 환기특성에 관한 수치적 연구 (Effects of the Distance between Jet Fans on the Ventilation Performance in a Road Tunnel)

  • 김정엽
    • 한국유체기계학회 논문집
    • /
    • 제14권4호
    • /
    • pp.25-30
    • /
    • 2011
  • The jet fan is generally used to add thrust in the longitudinal ventilation system of road tunnel and the geometric conditions of jet fan such as the distance from tunnel wall have an effect on the performance of ventilation system. Numerical analyses on the flow in tunnel caused by operation of jet fan are presented to study the ventilation characteristics in tunnel. While the distance between jet fans in parallel installed in tunnel is changed 0.5 L/D to 3.0 L/D, the flowrate and mean velocity through tunnel are calculated for each cases. As the distance between jet fans increases, the flowrate through tunnel increases asymptotically and the momentum of tunnel flow is alike.

냉동 컨테이너 적재부의 배관 형상에 따른 환기성능 실험 (Experimental analysis of ventilation performance varying with duct shapes inside reefer container hold)

  • 박일석;박상민;이동조;설신수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1710-1714
    • /
    • 2004
  • The analysis of ventilation performance varying with duct shapes in reefer container of scale-model has studied experimentally. Most container ships have ventilation system of which ducts extended to the bottom for the purpose of efficient exhausting of condensing heat from hold. However, the size of ducts is so over-long that it causes manufacturing troubles. In this study, for various types of duct, flow visualization using smoke and normalized temperature analysis are presented. Finally, the cooling performance are compared respectively.

  • PDF

차체 기밀특성이 선루프 성능에 미치는 영향 연구 (Study of Effects of Body Leakage on Performance of a Sunroof)

  • 이영림
    • 한국자동차공학회논문집
    • /
    • 제9권3호
    • /
    • pp.201-209
    • /
    • 2001
  • Some passenger cars with sunroofs open at tilted positions experience reverse flows into cabin rooms and wind noises much louder compared to other cars. In this study, flows around open sunroofs are numerically studied with the variations of body leakage. The effects of body leakage on ventilation and wind noise of a sun roof are examined, in particular. Furthermore, flow visualization, pressure, and noise measured from wind tunnel and road tests are presented. The results show that too small body leakage results in poor performance of ventilation and generates high wind noise around a sunroof. It is therefore very important to secure an adequate body leakage from the early design stage to achieve better performance of a sunroof as well as passengers' comfort related to HVAC(Heating, Ventilation, and Airconditioning).

  • PDF