• 제목/요약/키워드: Ventilation Noise

검색결과 129건 처리시간 0.028초

A Study on the Improvement of Comfortable Living Environment by Using real-time Sensors

  • KIM, Chang-Mo;KIM, Ik-Soo;SHIN, Deok-Young;LEE, Hee-Sun;KWON, Seung-Mi;SHIN, Jin-Ho;SHIN, YongSeung
    • 웰빙융합연구
    • /
    • 제5권4호
    • /
    • pp.19-31
    • /
    • 2022
  • Purpose: This study was conducted to identify indoor air quality in various living spaces using sensors that can measure noise, vibration, fine dust, and odor in real time and to propose optimal indoor air quality maintenance management using Internet of Things(IoT). Research design, data and methodology: Using real-time sensors to monitor physical factors and environmental air pollutants that affect the comfort of the residential environment, Noise, Vibration, Atmospheric Pressure, Blue Light, Formaldehyde, Hydrogen Sulfide, Illumination, Temperature, Ozone, PM10, Aldehyde, Amine, LVOCs and TVOCs were measured. It were measured every 1 seconds from 4 offices and 4 stores on a small scale from November 2018 to January 2019. Results: The difference between illuminance and blue light for each measuring point was found to depend on lighting time, and the ratio of blue light in total illumination was 0.358 ~ 0.393. Formaldehyde and hydrogen sulphide were found to be higher than those that temporarily attract people in an indoor office space that is constantly active, requiring office air ventilation. The noise was found to be 50dB higher than the office WHO recommendation noise level of 35 ~ 40dB. The most important factors for indoor environmental quality were temperature> humidity> illumination> blue light in turn. Conclusions: Various factors that determine the comfort of indoor living space can be measured with real-time sensors. Further, it is judged that the use of IoT can help maintain indoor air quality comfortably.

고속철도 터널 입구후드에 관한 수치해석적 연구 (Numerical Study on High-Speed railway Tunnel Entrance Hood)

  • 김희동;김동현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.604-611
    • /
    • 1998
  • High-speed railway trains entering and leaving tunnels generate finite amplitude pressure wave which propagate back and forth along the tunnels, reflecting at the open ends of the tunnels and at other discontinuities such as ventilation shafts and the train themselves. In present day railways, the magnitudes of the pressure waves are much too small to cause structual damage, but they are a serious potential source of aural discomport for passengers on unsealed trains. Almost always do the pressure waves propagating along the tunnels lead to a hazardous impulse noise near the exit portal of the tunnel. In order to alleviate such undesirable phenomena, some control strategies have been applied to the compression wave propagating inside the tunnel. The objective of the current work is to investigate the effect of tunnel entrance hoods on the entry compression wave at the vicinity of the tunnel entrance. Three types of entrance hoods were tested by the numerical method using the characteristics of method for a wide range of train speeds. The results show that the maximum pressure gradient of compression wave can be considerably reduced by the tunnel entrance hood. Desirable hood shape for reduction of the pressure transients and impulse noise was found to be of abrupt type hood with its cross-sectional area 2.5times the tunnel area.

  • PDF

테프론(PTFE) 막재료의 흡음율 측정방법에 대한 연구 (Case Study on Sound Absorption Rate Measurement Method of PTFE Membrane Material)

  • 박혜나;김정중;손장열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.645-648
    • /
    • 2005
  • The grounds of multipurpose practical use degree are built much holding world cup 2002 but material that is used in this building most external membrane ceiling is accomplishing PTEE A master and servant. Therefore, this research analyzed assessment about sound absorption special quality that measure ventilation quantitys of 10 act material and analyze correlation with Air Permeability and the sound absorption rate, and follow in change of layer of air of inside facts material. Result is as following. When Air Permeability good dimension is 5$\sim$15 cc/cm$^2$/sec and acoustic absorptivity is the best as Air Permeability result that measure acoustic absorptivity of inside facts material particularly firstly, could know 8$\sim$9 cc/cm$^2$/sec love. When establish sound absorption inside facts in external membrane as result that measure acoustic absorptivity of inside (acts material secondly, could know that acoustic absorptivity is good though become about minimum back layer of air 900mm.

  • PDF

Evaluation of Recursive PIV Algorithm with Correlation Based Correction Method Using Various Flow Images

  • Daichin;Lee, Sang-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.409-421
    • /
    • 2003
  • The hierarchical recursive local-correlation PIV algorithm with CBC (correlation based correction) method was employed to increase the spatial resolution of PIV results and to reduce error vectors. The performance of this new PIV algorithm was tested using synthetic images, PIV standard images of Visualization Society of Japan, real flows including ventilation flow inside a vehicle passenger compartment and wake behind a circular cylinder with riblet surface. As a result, most spurious vectors were suppressed by employing the CBC method, the hierarchical recursive correlation algorithm improved the sub-pixel accuracy of PIV results by decreasing the interrogation window size and Increased spatial resolution significantly. However, with recursively decreasing of interrogation window size, the SNR (signal-to-noise ratio) in the correlation plane was decreased and number of spurious vectors was increased. Therefore, compromised determination of optimal interrogation window size is required for given flow images, the performance of recursive algorithm is also discussed from a viewpoint of recovery ratio and error ratio in the paper.

차세대 도시철도 직접구동전동기 개발 (A Study on Development of Direct Drive Motor for Advanced Urban Transit System)

  • 김길동;오세찬;이장무;이한민;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.141-143
    • /
    • 2008
  • Due to the demand for high-output motors in the limited space between the wheels in an electric train, self-ventilating traction motors have been used for many years. periodical disassembly maintenance is necessary to remove the small quantities of dust that enter the motor from the open-air ventilation. Reducing this burden, as well as increasing efficiency and reducing noise, would benefit the next generation of moters To address these needs, KRRI is developing a fully enclosed type traction motor, a fully enclosed type traction motor with outer fans, a high-efficiency permanent-magnet synchronous motor and a direct-drive motor(DDM) as traction motors for the next generation of trains.

  • PDF

홍콩 버비나하이츠(Verbena Heights) 주거단지의 특징에 관한 연구 (A Study on the Architectural Characteristics of ¡?Verbena Heights¡?Estate in Hong Kong)

  • 이재훈;김남응;김성화
    • 한국주거학회논문집
    • /
    • 제13권3호
    • /
    • pp.21-31
    • /
    • 2002
  • The purpose of this study is to find the architectural characteristics of Verbena Heights, super high-rise complex housing, which has been most highly evaluated as a new town development model in Hong Kong, as a successful case of new housing type and sustainable design. The analyzed features of Verbena Heights are as follows; 1) Formation of various open spaces by a creative layout. 2) Enhancement of natural ventilation and daylighting by a linear plan instead of conventional cruciform plans. 3) Applications of integrated facade design for noise mitigation and for sunlight shading. 4) Adoption of energy-efficient devices, use of recyclable materials, and improvement of livability by a sustainable design process. These architectural characteristics provide the high-density high-rise housing with more efficient and comfortable environments for residents. And it is proved that the sustainable design can enhance the quality of dwelling environment.

차륜답면 변화에 따른 여객열차의 진동$\cdot$승차감 해석 (The analysis of the oscillating comfort in passenger coaches in accordance with variations of the wheel-tread.)

  • 박규한;박영일;김재철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.527-532
    • /
    • 2004
  • As well as the vibration comfort in passenger coaches largely affects passengers, it is one of the most important factors that passengers would betray their dissatisfactions among various elements, such as noise, lighting, couches, seat-arrangement, ventilation, temperature, odor, cleanliness, etc., consisting of comfort in passenger coaches. The wheel-tread figuration in the dynamic behavior of trainsets significantly affects the vibration comfort such as the running safety and the running stability. In this study, therefore, I will examine the dynamic characteristic in passenger coaches in accordance with the variation of wheel-tread figuration during the high-speed traveling with the target of trainsets (KT23 bogie), which are operated as the passenger coache in Korea, and any variation that will exert baneful influence on the vibration comfort accordingly.

  • PDF

아파트 거주자의 욕실에 대한 의식.만족.요수 -30평형대 아파트를 중심으로- (The dweller's consciousness, satisfaction and demands on bathroom in 30s pyung apartments)

  • 이영심;신경주
    • 한국주거학회논문집
    • /
    • 제9권1호
    • /
    • pp.43-53
    • /
    • 1998
  • The purpose of this study is to provide a basic study for a desirable bathroom planning of the 30s pyung apartment. The survey was performed to the housewives of 30s pyung apartments in Seoul. The purpose of the survey was to examine the dweller's consciousness, satisfaction, and demands on bathroom in 30s pyung apartments, and to give useful information on bathroom planning of 30s pyung apartment. Some details shoul be considered in bathroom planning of 30s pyung spartments. It seems that the bathrooms of bath unit and extra sink and a toilet stool are the most approriate type in 30s pyung apartment among present bathroom types. It is suitable that the bathroom is close to bedroom and the bathroom door faces the wall. There is much meed for a showercurtain and more comfortable toilet stool. It is necessary to reduce the noise of toilet stool and reinforce the soundproofing fuction in bathroom. And the function of ventilation, drainage, and insulation should be improved for better bathroom enivronment. The implications of this findings for apartment bathroom planning and future research were discussed.

  • PDF

UPS 기능을 갖는 A/C Blower용 Inverter 시스템 개발 (Development of the Inverter System with UPS Function for the Air-Conditioning Blower)

  • 임승범;이윤하;지준근;목형수;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.345-346
    • /
    • 2010
  • The HVAC(Heating Ventilation and Air Conditioning) system is only controlled by turn on/turn off operations against to AC 380V input. Therefore, the efficiency of the system is reduced and noise occurs. Also, the blower is shut down at the AC power failure. In this paper, the inverter system with UPS function for the A/C(Air Conditioning) blower is proposed. Proposed inverter system which is powered from the AC and DC voltage can control speed, operation mode, and soft-start time using CAN communication. In case of the CAN communication failure, RS-232 communication could be used to control the hardware directly by the engineer that can solve existing problems. To verify the validity of proposed inverter system, simulations and experiments are carried out.

  • PDF

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.