공동주택의 실별 제어환기 도입 타당성 분석 (Feasibility Study on Installation of Individual Room Control Ventilation in Apartment House)

  • 김정엽;신현준;권용일;윤영우;조춘식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.502-507
    • /
    • 2009
  • Trend of mechanical ventilation system applied to apartment house is introduced and feasibility study on installation of the individual room control ventilation as energy-saving method is carried out through field experiment. While initial cost of installation for the individual room control ventilation increases, the running cost is lower than the individual household control ventilation due to automatic flow rate control and reduction of fan power, and the management cost also decreases due to extension of use life of components. As the results of field experiment on $115m^2$-type apartment house, the individual room control ventilation could save the amount of 1,459.5Wh/day when compared with the individual room control ventilation

  • PDF

업무용 빌딩 소재 사무실의 실내환기 평가 (Assessment of indoor ventilation in commercial office buildings)

  • 정지연;이광용;이병규
    • 한국산업보건학회지
    • /
    • 제18권2호
    • /
    • pp.115-121
    • /
    • 2008
  • In winter season, the survey was performed in three commercial office buildings in the metropolitan Seoul, Pusan, and Gwangju city. The purpose of the survey was to evaluate the effectiveness of ventilation for offices in commercial buildings. The data were compared to standard of applicable to the indoor ventilation in office. The results indicated that the most commercial office buildings used the air handing unit and fan coil unit as HVAC system, and the intake amount of fresh outdoor air were very inadequate to compared to the ASHRAE standard value of $0.57\;m^3/min/person$. Also the surveyed all commercial office building used the HVAC system as a meas of controlling temperature for office indoor air. Ultimately, these results presented that there were possibility of evoking indoor air quality problems by the insufficient ventilation.

제트 팬 가동위치에 따른 장대터널 내 CO 농도 변화율에 대한 전산해석 (Investigate on the rate of change of CO concentration in a tunnel under changed position of the jet fans by using numerical method)

  • 민재홍;김대현;정진택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2765-2770
    • /
    • 2008
  • The purpose of tunnel ventilation system for long road tunnels is to keep certain levels of Visibility Index and the concentration of CO. Additional equipments such as jet fans are used in road tunnel to discharge pollutants in the road tunnel. The control algorism of tunnel ventilation system takes the value of sensors as input, and then gives the operation method of jet fans in tunnel as output. Information on the variation of CO concentration in tunnel when jet fans are running is needed to minimize their operation time. Numerical analysis is used in this paper because of the difficulty of conducting experiments under standard condition for ventilation of road tunnel. The concentration of CO has been calculated by using 3-dimensional CFD under transient condition with speed of cars, quantity of air ventilation, and the results for various operation position of jet fans are compared.

  • PDF

등압법과 T-Method법을 이용한 주택환기시스템 덕트설계법의 비교실험 (The Comparative Experiment of Duct Design Method with Equal Friction Loss Method and T-Method on a House Ventilation System)

  • 주성용;김광현;최석용;이정재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.99-104
    • /
    • 2006
  • Accurate flow rate distribution has been become a very important part for controling of air change rate since the introduction of house ventilation system. An inappropriate selection of fan due to Incorrect prediction of friction loss makes waste energy. The purpose of this study is to recognize applicability of T-Method at house ventilation system by comparing experiment with T-method, The result of this study is as follows Flow rate is small amount in a house, so duct size must be accurate. And duct design with Equal Friction Loss Method presented large error range. Equal friction loss method is not fit to applicate small amount air flow rate. T-Method predicts accurate flow rate comparatively in a house ventilation system. Error range was 3.5%.

  • PDF

아연도금 부스 환기시스템 개선에 관한 수치해석 (Numerical Analysis on the Improvement of Zinc Plating Booth Ventilation System)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제24권1호
    • /
    • pp.45-51
    • /
    • 2021
  • The purpose of this study is to suggest the optimal shape for a local air ventilation system for fume removal, which is operated in a zinc galvanizing factory, and to propose the improvement plan for a ventilation system used in a zinc galvanizing factory through flow analysis. A part of the air sprayed by an air curtain goes out. It will be necessary to research the position of an air curtain, its spray angles, and its nozzle shape. In addition, additional research needs to be conducted on the shape of the fan installed before a hood in order to make it easy to induce fume. In a local air ventilation system, air is inhaled from the outside. The higher an inlet negative pressure is, the easier fume is removed. It was found that it was necessary to install an appropriate hole in the wall on the back of a push nozzle in order to reduce an inlet negative pressure.

허브 형상에 따른 정풍량 환기팬의 유동과 성능특성 (Flow Behavior and Performance Characteristics of Constant Air Volume Fan According to Different Hub Shape)

  • 이호호;최항철;정재구;이윤표;신유환;정진택
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.57-62
    • /
    • 2012
  • The constant air volume flow fan can maintain constant flow rate to the wide range of exit pressure. Therefore, the use of this fan is increasing recently for ventilation of high building. Brushless DC motor is adopted to this fan because that has advantages of compactness and performance. But this type of motor protrude from impeller hub side to fan inlet. The Impeller inlet flow is influenced by size of this obstacle called hub. In this paper, the influence of hub shape on the fan performance characteristics are experimentally and numerically analyzed. CFX 12.0 is used to perform the fan internal flow analysis and numerical results are compared with the experiments. Depending on hub shape, internal loss is generated and the performance and efficiency are reduced. The best performance is occurred around $h/b_1$ = 0.25. The results of this study will be contribute to initial design of constant air volume flow fan development.

주거환기용 시로코홴의 공력 및 소음 특성 연구 (A Study on Aerodynamic and Noise Characteristics of a Sirocco Fan for Residential Ventilation)

  • 김진혁;송우석;이승배;김광용
    • 한국유체기계학회 논문집
    • /
    • 제13권2호
    • /
    • pp.18-23
    • /
    • 2010
  • This paper presents a procedure for the aerodynamic and aeroacoustic characteristics of a sirocco fan. For the aerodynamic and aeroacoustic analyses of the sirocco fan, three-dimensional steady and unsteady Reynolds-averaged Navier-Stokes equations are solved with a shear stress transport turbulence model for turbulence closure. The flow analyses were performed on a hexahedral grid using a finite-volume solver. The validation of the numerical results is performed by comparing with experimental data for the pressure, efficiency and power. The internal flow analyses of the sirocco fan are performed to understand the unstable flow phenomenon on the casing for the wall pressure and internal flow characteristics at each position. It was found that fluctuation of pressure and locally concentrated noise source are observed near the cut-off and expansion regions of the casing.

원심 다익홴의 유동에 대한 컷 오프 각도의 영향 (Effect of Cut-off Angle on Flow Pattern of Centrifugal Multi-blade Fan)

  • 강경준;신유환;이윤표;김광호
    • 한국유체기계학회 논문집
    • /
    • 제13권3호
    • /
    • pp.37-42
    • /
    • 2010
  • This study investigated on details of flow characteristics of a multi-blade fan for domestic ventilation. Experiments and analysis were carried out to describe on flow pattern with variations of cut-off angle near the scroll housing throat, which were performed by PIV measurement for the flow field and by total pressure probes. The stagnation point at cut-off region of the fan moves to the exit of the scroll housing as the cut-off angle increases. The movement of stagnation point and the variation of throat area of the scroll housing influence to the distribution of velocity magnitude at the exit of the fan. Furthermore, a large distortion of the velocity distribution at the scroll exit causes to increase mixing loss along the flow path.

A New Blade Profile for Bidirectional Flow Properly Applicable to a Two-stage Jet Fan

  • Nishi, Michihiro;Liu, Shuhong;Yoshida, Kouichi;Okamoto, Minoru;Nakayama, Hiroyasu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.449-455
    • /
    • 2009
  • A reversible axial flow fan called jet fan has been widely used for longitudinal ventilation in road tunnels to secure a safe and comfortable environment cost-effectively. As shifting the flow direction is usually made by only switching the rotational direction of an electric motor due to heavy duty, rotor blades having identical aerodynamic performance for bidirectional flow should be necessary. However, such aerodynamically desirable blades haven't been developed sufficiently, since most of the related studies have been done from the viewpoint of unidirectional flow. In the present paper, we demonstrate a method to profile the blade section suitable for bidirectional flow, which is validated by studying the aerodynamic performances of rotor blades of a two-stage jet fan experimentally and numerically.

단동 비닐하우스의 지붕 환기장치 설치방법 개선이 참외생육 및 과실수량에 미치는 영향 (Effects of Modified Installation Methods of Roof Ventilation Devices in the Single-span Plastic Greenhouses on Yield and Fruit Quality of Oriental Melon)

  • 여경환;유인호;최경이;이성찬;이재한;박경섭;이중섭
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.334-342
    • /
    • 2016
  • 지붕 환기장치 설치방법의 개선에 의한 작물 재배효과를 검증하고자 농가현장에서 개선 지붕 환기방식과 관행환기방식을 비교, 분석하였다. 개선 지붕 환기방식은 참외재배 단동 플라스틱 온실(폭 5.6m, 길이 108m, 측고 1.1m, 동고 2.2m)에 지붕 환기팬(용량 $38m^3/min$)과 환기통(지름 60cm)을 각각 15m와 6m 간격으로 설치하였고, 대조구로서 관행 지붕 환기방식은 각각 20m와 8m 간격으로 설치하였다. 관행 및 개선 지붕 환기 방식에 따른 생육을 조사한 결과, 관행 환기통과 환기팬 처리에 비해 개선 환기통과 개선 환기팬 처리에서 경경, 엽장, 엽병장, 및 엽폭의 값이 낮게 나타나는 경향을 보였다. 생육기 전반부에 관행 환기통 처리는 환기팬 처리에 비해 절간장이 다소 길게 발달하였는데 이는 착과수가 환기팬 처리에 비해 적었고, 착과수 감소로 인해 동화산물이 잎과 줄기의 신장부로 좀 더 이동된 영향으로 판단되었다. 참외재배 단동 비닐하우스에서 과실 수량을 조사한 결과, 개선 환기팬과 개선 환기통 처리는 관행처리에 비해 과중은 약간 작았지만, 착과수 증가로 인해 전체 수량은 높게 나타났다. 개선 환기팬과 개선 환기통 설치 하우스에서는 관행 지붕 환기 하우스에 비해 상품과율이 높았으며, 10a당 상품수량도 각각 8,391kg, 7,283kg 으로 나타나 관행 지붕 환기에 비해 개선 환기팬 처리는 661kg, 개선 환기통 처리는 487kg 더 증가하였다. 개선 환기팬 처리는 고온기에 암꽃수와 착과수가 가장 많았고, 낙과수는 가장 낮게 나타났으며, 관행의 환기통 처리에 비해 과실의 크기는 작았다. 시기별 환기방식에 따른 참외 과실의 품질을 조사한 결과, 관행 환기통 환기에서 과중, 과경, 과폭, 및 과육두께가 가장 높게 나타났으나, 과폭, 과육두께에 있어서 통계적인 유의차는 나타나지 않았다.