A Study of Ventilation Requirements for Tunnel Considering Recirculation near Tunnel Portals (인접 터널로부터의 재유입을 고려한 터널 내 소요환기량 산정 연구)

  • Rie, Dong-Ho;Choi, Baek-Yeol;Yoon, Sung-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.66-70
    • /
    • 2010
  • This paper analyzes difference between current tunnel ventilation calculation method and advanced one which considers effects of polluted air recirculation near tunnel portals. For the calculation, CFD(Computational fluid dynamics) technique was utilized. From the result, it was found that 4.38% more fresh air is required when there is polluted air recirculation near tunnel portal areas. Hence, it is recommanded that the consideration of polluted air recirculation should be made when deciding the ventilation requirements for tunnel.

The Effects of Micro-Environmental Factors on the House Dust Mite

  • Jo, Wan-Je;Sohn, Jang Yeul
    • Architectural research
    • /
    • v.9 no.2
    • /
    • pp.37-45
    • /
    • 2007
  • The proliferation of the House Dust Mite(HDM) is affected by temperature, humidity, ventilation, etc. Measuring temperature and humidity was performed at the very location where dust samplings take place and where they live in reality together with temperature and humidity of the ambient of the room. There has been discussion over the key environment factor of HDM survival; absolute humidity or relative humidity. It seems that relative humidity is the more important determinant for the mite's survival through the analysis of previous studies. Temperature, humidity, ventilation rate and Der P1 were measured in 4 flats in London. Mite allergen was detected in every house. Levels of Der P1 varied between <100ng/g and 22,778ng/g. Flats with high relative humidity(>50%) and poor ventilation(<0.5ach) showed higher levels of mite allergen than flats with lower humidity and adequate air change rate. Questionnaire survey was conducted and the result helped to confirm the findings from monitoring of environmental factors and the dust sampling.

Analysis of Ventilation Rates in Residential Buildings using a Multizone Network Model (멀티존 네트워크 모델을 이용한 주거용 건물의 환기량 분석)

  • Cha, Ji-Hyoung;Park, Cheol-Hun;Kim, Yeong-Ha;Baek, Chang-In;Han, Hwa-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.45-50
    • /
    • 2005
  • The supply outdoor airflow rates are calculated and analyzed using a multizone network model in a high-rise residential apartment. The system parameters include parameters related to weather conditions, building conditions, operation conditions, and facility conditions. Simulations are conducted according to the method of design of experiments and analysis of variance is conducted to investigate the effects of parameters on ventilation rate. A correlation equation is derived to predict ventilation rates of the building depending on the various parameters.

  • PDF

High Frequency Jet Ventilation via Cricothyroid Membrane Puncture under Microlaryngoscopic Surgery (미세 후두현미경술시 윤상갑상막천자를 통한 고빈도 제트환기법)

  • 양훈식;김용주;김춘길
    • Korean Journal of Bronchoesophagology
    • /
    • v.1 no.1
    • /
    • pp.109-115
    • /
    • 1995
  • High frequency Jet ventilation (HFJV) via cricothyroid membrane puncture contols frequency of ventilation as 20-200/min and persuits adequate gas exchange. HFJV was known to have advantages such as improvement of PaO$_2$, lesser barotrauma, stable hemodynamic effects, good operative field and lesser movement of head. The purpose of this study was to clarify the advantages of HFJV in cases of microlaryngeal surgery which operating time was expected even within 30 minutes. Twenty-eight patients were divided two groups : 1)control group : general endotracheal Intubation anesthesia. 2)experimental group : HFJV via cricothyroid membrane puncture with intravenous anesthesia, frequency 40/min, I/E ratio 40%, driving pressure 40 psi. We analyzed blood pressure, arterial blood gas, score of general condition and recovery time after operation. In conclusion, HFJV via cricothyroid membrane puncture had a good score of general condition and rapid recovery of consciousness, although some accumulation of P$CO_2$and elevation of blood pressure.

  • PDF

Experimental Study on the Effect of Environmentally Friendly Materials on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 친환경 마감자재 사용에 따른 실내공기질 개선효과 실증연구)

  • Park, Young-Sok;Lee, Gyu-Dong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.139-142
    • /
    • 2006
  • The indoor air quality of new apartment buildings, which is known to cause sick housing syndrome, has become a major concern among apartment residents as well as construction companies in Korea. In this study, the effects of environmentally friendly materials and ventilation system are evaluated to compare the strategies applied to improve indoor air quality at the pre-occupancy stage. Six residential units are tested under three conditions : one unit is consisted of environmentally friendly materials and ventilation system, another unit is consisted of environmentally friendly materials and non-ventilation system, and the other four units are consisted of common materials and non-ventilation system.

  • PDF

Minimum Ventilation Rate of Kindergarten in the respect of IAQ (실내공기질을 고려한 유치원 보육실의 적정 환기량 검토)

  • Cheong, Chang-Heon;Lee, Yun-Gyu;Kim, Tae-Youn;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.283-288
    • /
    • 2006
  • Indoor Air Quality Guideline of Kindergarten in korea didn't consider the vulnerable properties of children to indoor air pollutants. For this reason, Suggestion for the IAQ guideline of formaldehyde and minimum ventilation rate was made in this study. Suggested IAQ guidelines for formaldehyde in the respect of children's vulnerable immune system is $30{\mu}g/m^3$ and $50{\mu}g/m^3$, and for the ventilation rate 11.9 ACH, 5.8 ACH, respectively. This value is based only formaldehyde and CO2 concentrations in child-care room of Kindergarten and needed to be verified by further investigations and studies. However it is discovered that lower formaldehyde concentration can do mal-effects to children's health by literature review.

  • PDF

A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels (도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구)

  • Yoo, Yong-Ho;Yoo, Ji-Oh;Kim, Hyo Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.553-560
    • /
    • 2014
  • The road tunnel install a vent for the purpose of ventilation and smoke control. Ventilation equipment capacity(number of jet fans) depends on from the condition that of the pressure and ventilation resistance. Pressure and the resistance under operating vehicle have affected on the drag coefficient. The drag coefficient of the tunnel have affected by the blockage effect and slipstream effects. However, when calculating the ventilation fan, are not properly consider taking into account such effects. Therefore, ventilation force may have been slightly overestimated. This paper describes the drag coefficient through a numerical analysis to calculate the equivalent resistance area that reflects the vehicle distance, and examined the equivalent resistance area. The ventilation coefficient corresponding to the result heavy vehicle mixing ratio of the present study was not clear. Equivalent resistance area had reduced by about 86% compared to the road design handbook current standards. Also it had analyzed and reduced to 62.2% compared to Korea Highway Corporation ventilation design criteria ratio, which is the old standard.

A numerical study on the ventilation characteristics of rainfall in road tunnel (강우변화를 고려한 도로터널의 환기특성에 관한 수치해석)

  • Lee, Ho-Hyung;Lee, Seung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.341-351
    • /
    • 2015
  • When rainfall occurred on road tunnel, that is likely to have influence upon ventilation force in the tunnels but the tunnels ventilation system did not consider factors of rainfall. Thus, this study investigated effects of rainfall upon ventilation force in the tunnels at no rainfall and changing of rainfall by 3 dimensional numerical method. Flow rate into road tunnels decreased as many as 52.34% at rainfall of 150 mm/hr, and pressure drop of road tunnel between entrance and exit decreased as many as 22.22%, so that rainfall had influence upon ventilation force in the tunnel. The number of necessary jet fan in road tunnels is 12 at no rainfall but, when rainfall of 80 mm/hr on road tunnels, the number of necessary jet fan in road tunnels is 16, when rainfall of 150 mm/hr on road tunnels, the number of necessary jet fan in road tunnels is 17. So, factor of rainfall should be considered at estimation of ventilation system of road tunnel.

An experimental study on the performance of the separate type heat pipe in accordance with the refrigerant charge (냉매 충진량에 따른 분리형 히트파이프 성능에 관한 실험적 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1600-1604
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this research, we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. Heat-pipe used in this study was designated separately to be applied to a ventilation system. The working fluid was R22, which was filled from 40 to 55 (%vol.) by 5(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

Assistant device development and effects for promotion of bag-valve-mask ventilation (백-밸브-마스크 환기증진을 위한 보조기구 개발 및 효과)

  • Kwon, Chan-Yang;Lee, In-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.49-59
    • /
    • 2018
  • Purpose: The purpose of this study was to develop an assistant device for the promotion of bag-valve-mask ventilation based on a non-equivalent control group pre-test and post-test design. Methods: The experimental tool was a mask assistance device developed by the researchers. Data were analyzed using SPSS 21.0 with the cardiopulmonary resuscitation (CPR) evaluation program from August 18 to 30, 2016. The research tools included general, hand-related, and ventilation-related characteristics. Results: Before and after using the mask assistance device, the tidal volume increased by 64 mL (p<.001) from 461.76 mL to 525.86 mL. The tidal volume for control was 477.86 mL, and there was a statistical difference (p<.05). The ventilation frequency in device users was 10 times per minute for a total of 20 ventilations with before 10.65 after 10 times, and that of the control group was before 10.36 times after 10 times; there was no difference in both groups(p>.05). The accuracy of the assistance device was $81.72{\pm}30.86%$, which was a very high value. However, the accuracy of ventilation in the control group with no assistance device was $18.97{\pm}32.44%$, which was a very low accuracy rate. Conclusion: This study's results suggested utilizing the newly-developed mask assistance device in CPR, and showed increases in tidal volume and accuracy of ventilation using the bag-valve-mask ventilation equipment. The general and hand-related characteristics did not have any effect, so the use of the device proved to increase the efficacy in all users.