• Title/Summary/Keyword: Ventilation Characteristics

Search Result 632, Processing Time 0.027 seconds

Phyto-restoration Potential of Soil Properties using Secale cereale for Recycle of Soils with Residual TPHs (Total Petroleum Hydrocarbons) after Off-site Treatment (잔류유분 함유 반출처리토 재활용을 위한 호밀 식재 식물상 토성회복 가능성)

  • Park, Jieun;Bae, Bumhan;Joo, Wanho;Bae, Seidal;Bae, Enjoo
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.25-32
    • /
    • 2014
  • The amount of TPH contaminated soil treated at off-site remediation facilities is ever increasing. For the recycle of the treated-soil on farmlands, it is necessary to restore biological and physico-chemical soil characteristics and to remove residual TPH in the soil by an economic polishing treatment method such as phytoremediation. In this study, a series of experiments was performed to select suitable plant species and to devise a proper planting method for the phyto-restoration of TPH-treated soil. Rye (Secale cereale) was selected as test species through a germination test, among 5 other plants. Five 7-day-old rye seedlings were planted in a plastic pot, 20 cm in height and 15 cm in diameter. The pot was filled with TPH-treated soil (residual TPH of 1,118 mg/kg) up to 15 cm, and upper 5 cm was filled with horticulture soil to prevent TPH toxic effects and to act as root growth zone. The planted pot was cultivated in a greenhouse for 38 days along with the control that rye planted in a normal soil and the blank with no plants. After 38 days, the above-ground biomass of rye in the TPH-treated soil was 30.6% less than that in the control, however, the photosynthetic activity of the leaf remained equal on both treatments. Soil DHA (dehydrogenase activity) increased 186 times in the rye treatment compared to 10.8 times in the blank. The gross TPH removal (%) in the planted soil and the blank soil was 34.5% and 18.4%, respectively, resulting in 16.1% increase of net TPH removal. Promotion of microbial activity by root exudate, increase in soil permeability and air ventilation as well as direct uptake and degradation by planted rye may have contributed to the higher TPH removal rate. Therefore, planting rye on the TPH-treated soil with the root growth zone method showed both the potential of restoring biological soil properties and the possibility of residual TPH removal that may allow the recycle of the treated soil to farmlands.

A Field Survey on the Odor Concentration in Piggery by the Change of the Season (돈사 내에서 계절별 악취 발생 농도 조사 연구)

  • Kam, D.H.;Jeong, J.W.;Choi, H.C.;Song, J.I.;Hong, J.T.;Lee, D.W.;Yoo, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.187-194
    • /
    • 2007
  • Six pig farms were surveyed to measure the odor concentrations and characteristics of ammonia and sulfide corollary compounds in piggery. They were depended on the scale of piggery, weather conditions such as temperature, humidity, wind speed and direction, scales and types of pig breeding, and manure treatment methods. The highest ammonia concentrations in piggery were measured during the winter, since the tight sealed insulation in piggery made less amount of generated ammonia discharged from piggery. The objective of this study was to measure concentrations of odor in the piggery by season and growing, and to measure concentrations of odor at boundary area. So, we investigated the raising managements, manure managements, and methods of reducing odor according to farm scale. We found that concentration of ammonia gas in the swine fattening piggery in winter was the highest. This result is consistent with the lower ventilation rate to maintain Indoor temperature. In this result, there was no connection between farm scale and ventilating system. Concentration of ammonia gas was 1.64 ppm at one boundary area in the middle scale. $H_2S$, $CH_3SH$, $(CH_3)_2S$, and $(CH_3)_2S_2$ were below the standard of protection odor policy.

  • PDF

Analysis of Changes and Factors Influencing IAQ in Subway Stations Using IoT Technology after Bio-Filter System Installation (IoT 기반 지하역사 내 바이오필터시스템 설치에 따른 실내공기질 변화 및 영향 요인 분석)

  • Yang, Ho-Hyeong;Kim, Hyung-Joo;Bang, Sung-Won;Cho, Heun-Woo;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.410-424
    • /
    • 2021
  • Background: Subway stations have the characteristics of being located underground and are a representative public-use facility used by an unspecified number of people. As concerns about indoor air quality (IAQ) increase, various management measures are being implemented. However, there are few systematic studies and cases of long-term continuous measurement of underground station air quality. Objectives: The purpose of this study is to analyze changes and factors influencing IAQ in subway stations through real-time continuous long-term measurement using IoT-based IAQ sensing equipment, and to evaluate the IAQ improvement effect of a bio-filter system. Methods: The IAQ of a subway station in Seoul was measured using IoT-based sensing equipment. A bio-filter system was installed after collecting the background concentrations for about five months. Based on the data collected over about 21 months, changes in indoor air quality and influencing factors were analyzed and the reduction effect of the bio-filter system was evaluated. Results: As a result of the analysis, PM10, PM2.5, and CO2 increased during rush hour according to the change in the number of passengers, and PM10 and PM2.5 concentrations were high when a PM warning/watch was issued. There was an effect of improving IAQ with the installation of the bio-filter system. The reduction rate of a new-bio-filter system with improved efficiency was higher than that of the existing bio-filter system. Factors affecting PM2.5 in the subway station were the outdoor PM2.5, platform PM2.5, and the number of passengers. Conclusions: The IAQ in a subway station is affected by passengers, ventilation through the air supply and exhaust, and the spread of particulate matter generated by train operation. Based on these results, it is expected that IAQ can be efficiently improved if a bio-filter system with improved efficiency is developed in consideration of the factors affecting IAQ and proper placement.

Extended Use of Extracorporeal Membrane Oxygenation for Acute Respiratory Distress Syndrome: A Retrospective Multicenter Study

  • Kim, Won-Young;Park, SeungYong;Kim, Hwa Jung;Baek, Moon Seong;Chung, Chi Ryang;Park, So Hee;Kang, Byung Ju;Oh, Jin Young;Cho, Woo Hyun;Sim, Yun Su;Cho, Young-Jae;Park, Sunghoon;Kim, Jung-Hyun;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.3
    • /
    • pp.251-260
    • /
    • 2019
  • Background: Beyond its current function as a rescue therapy in acute respiratory distress syndrome (ARDS), extracorporeal membrane oxygenation (ECMO) may be applied in ARDS patients with less severe hypoxemia to facilitate lung protective ventilation. The purpose of this study was to evaluate the efficacy of extended ECMO use in ARDS patients. Methods: This study reviewed 223 adult patients who had been admitted to the intensive care units of 11 hospitals in Korea and subsequently treated using ECMO. Among them, the 62 who required ECMO for ARDS were analyzed. The patients were divided into two groups according to pre-ECMO arterial blood gas: an extended group (n=14) and a conventional group (n=48). Results: Baseline characteristics were not different between the groups. The median arterial carbon dioxide tension/fraction of inspired oxygen ($FiO_2$) ratio was higher (97 vs. 61, p<0.001) while the median $FiO_2$ was lower (0.8 vs. 1.0, p<0.001) in the extended compared to the conventional group. The 60-day mortality was 21% in the extended group and 54% in the conventional group (p=0.03). Multivariate analysis indicated that the extended use of ECMO was independently associated with reduced 60-day mortality (odds ratio, 0.10; 95% confidence interval, 0.02-0.64; p=0.02). Lower median peak inspiratory pressure and median dynamic driving pressure were observed in the extended group 24 hours after ECMO support. Conclusion: Extended indications of ECMO implementation coupled with protective ventilator settings may improve the clinical outcome of patients with ARDS.

Characteristics of Radon Reduction of Small-scale Water Supply System (소규모수도시설 지하수의 라돈저감 특성)

  • Cho, Byong-Wook
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.37-50
    • /
    • 2019
  • It is possible that radon removal in groundwater of small-scale water supply system (SWSS) is caused by atmospheric storage and aeration facilities installed in the water tank. Radon removal rates at water tank and tap of the 32 SWSS during summer season ranged from -69.3% to 62.7% (average 25.7%) and from -64.3% to 83.1% (average 30.3%) while those of 16 SWSS during autumn season ranged from 21.3% to 78.0% (average 42.8%) and from 17.7% to 66.9% (average 44.8%). The reason of higher radon removal rate in the autumn season compared with the summer season is due to higher atmospheric storage effect by lower groundwater use rate. The radon removal rates at the water tank from 12 SWSS were 47.4~94.0% (average 78.9%), in which the removal rates at the atmospheric storage are also included. Atmospheric storage and aeration can be used to reduce radon concentration in SWSS groundwater. For more efficient use of radon reduction, further studies are necessary to assess the radon removal rate considering variation conditions of radon concentration in groundwater, size and forms of water tank, change in groundwater usage rate, aeration capacity and ventilation facilities.

A Study of Dispersion Characteristics of Sunsik Using Fluidized-Bed Granulator (유동층 과립기를 이용한 선식의 분산 특성)

  • Kim, Gorae;Hwang, Yunhee;Lee, Seokhoon
    • Food Engineering Progress
    • /
    • v.21 no.3
    • /
    • pp.267-272
    • /
    • 2017
  • To improve dispersibility of cereal powder without additives, granulation of cereal powder was conducted using fluidized-bed granulator. Operation condition was sample 300 g, internal temperature $40^{\circ}C$, ventilation speed $30-90m^3/h$, inlet temperature $90^{\circ}C$ and spray pressure 2.5 bar. The amount of distilled water (20-45%) as binder, granulation time (10-15 min) and drying time (3-10 min) were controlled. Mean diameter over volume (Brouckere mean, $D_{4,3}$) was increased from $123{\mu}m$ to $263{\mu}m$ and dispersibility was improved from 73% to 92.25% at experiment conditions. Wettability (wetting time) was drastically decreased from 5,000 second to 7 second. Granulation of cereal powder did not affect sinkability and mean diameter over volume as wet analysis was about the same between raw and granulated cereals. Such phenomenon means that granulation with only water as binder enables cereal powder to disperse in water or milk without rapid sedimentation.

Exposure Levels and Influence Factors of PAHs and Benzene Metabolites in the Urine of the General Korean Adult Population - Korean National Environmental Health Survey (2009-2017) - (우리나라 성인의 체내 PAHs 및 벤젠 대사체 노출수준 및 영향요인 분석 - 국민환경보건 기초조사(2009-2017) -)

  • Kwon, Young Min;Joo, Youngkyung;Park, Choong-Hee;Kim, Sung Yeon;Choi, Kyungho;Lee, Chulwoo;Yu, Seung Do;Yoo, Jiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.5
    • /
    • pp.529-540
    • /
    • 2019
  • Objectives: The aim of this study is to compare exposure levels of PAHs and benzene metabolites in the urine of nationally representative adults in Korea and identify exposure factors in relation to questionnaire results. Methods: The study analyzed PAHs and benzene metabolites in the urine of adults aged 19 and older recruited in Cycles 1-3 of the Korean National Environmental Health Survey (KoNEHS). Participants were administered questionnaires on demographic characteristics, lifestyle, and dietary habits to identify the association with exposure levels to environmental chemicals. Results: 1-hydroxypyrene and t,t-muconic acid levels in this study were higher than those in large-scale biomonitoring conducted in other countries (the US and Canada), while 2-hydroxynaphthalene levels were lower. Most environmental chemicals exhibited significant differences depending on gender and age, and exposure levels tended to increase with grilled food intake. In addition, variables such as smoking, distance between home and a road, travelling on public transportation, and ventilation time had a significant effect on exposure to environmental chemicals. Conclusions: The importance of this study lies in utilizing the representative results of KoNEHS, large scale biomonitoring conducted in Korea over roughly ten years. Variables including smoking and roasted food intake were found to affect exposure to PAHs and benzene, which can be used to establish baseline exposure levels of environmental chemicals in Korea.

A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window (창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구)

  • Lee, Jang-bum
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.11
    • /
    • pp.25-34
    • /
    • 2019
  • It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.

Toxin Gene and Antibiotic Resistance of Staphylococcus aureus and Bacillus cereus Isolated from Indoor Air in Cafeteria (급식실 실내공기에서 분리된 황색포도상구균과 바실러스 세레우스의 독소 유전자 및 항생제 내성)

  • Oh, Do-Gyung;Jo, Ah-Hyeon;Kim, Chan-Yeong;Jeong, Eun-Sun;Kim, Jung-Beom
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.6
    • /
    • pp.520-527
    • /
    • 2021
  • In this study, toxin gene and antibiotic resistance of food poisoning strains isolated from indoor air in the cafeteria were analyzed to prevent food poisoning. Staphylococcus aureus (16 strains) and Bacillus cereus (37 strains) isolated from indoor air in child care center were tested. The toxin genes of S. aureus and B. cereus were detected by PCR assay. The antimicrobial susceptibility test followed the disc diffusion method described by the Clinical and Laboratory Standard Institute. The seg and sei toxin genes were detected in 11 of 16 S. aureus strains (68.6%). The nheA and nheB toxin genes were detected in 37 B. cereus strains. In this study, a total of 12 toxin gene patterns of B. cereus were found, among which the nheA-nheB-nheC toxin gene was found to be the most frequent pattern. The result of the antimicrobial susceptibility test of S. aureus revealed 93.8% and 87.5% resistance to ampicillin and penicillin antibiotics, but methicillin resistance S. aureus and vancomycin resistance S. aureus were not detected. All 37 B. cereus tested in this study were resistant to ampicillin and penicillin antibiotics. Based on the result of this study, it was judged that regular ventilation and air quality management were necessary to prevent food poisoning caused by S. aureus and B. cereus contaminated in the indoor air of child care centers.

A Study on Measures to Prevent Leakage of Process Fluid from the VCR Fitting used in the Semiconductor Manufacturing Process (반도체 제조 공정에서 사용되는 이송배관 연결부위(VCR Fitting)로부터 공정유체 누출사고 예방 대책에 관한 연구)

  • Dae Joon Lee;Sang Ryung Kim;Sang Gil Kim;Chung Sang Kang;Joon Won Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.79-85
    • /
    • 2023
  • Recently, in the semiconductor process, large companies are seeking process changes from memory semiconductors to the foundry due to the increase in demand due to the 4th industry. industry is expanding. The characteristics of special gases and precursors, which are raw materials used to produce these semiconductor chips, are toxic, pyrophoric, inflammable, and corrosive. These semiconductor raw materials are operated in a closed system and do not leak to the outside during normal times, but when leaked, they spread to the inside of the gas box, and when proper ventilation is not provided inside the gas box, they spread to the outside, causing fires, explosions, or toxic substances. It can lead to major accidents such as leakage. Recently, there have been cases of accidents in which hazardous materials leaked from the closed system of the semi conductor process and spread to the inside and outside of the gas box. . In this study, we propose preventive measures based on the case of an accident in which raw material leaked from the VCR fitting, which is the connection part of the semiconductor raw material transfer pipe, and spread to the outside of the gas box.