• Title/Summary/Keyword: Ventilation Characteristics

Search Result 640, Processing Time 0.031 seconds

A Study on the Importance of Contents in Middle-School Home-Economics (중학교 가정과 교육내용의 중요성에 관한 연구 -전북지역을 중심으로-)

  • 박일록
    • Journal of Korean Home Economics Education Association
    • /
    • v.9 no.2
    • /
    • pp.69-85
    • /
    • 1997
  • The purpose of this study was to identify the important contents from teachers’, parents’and students’view points based on the sixth Home Economics textbook contents, to apply these results at school settings and to provide the materials as a basis for the next curriculum revision. Subjects were 59 teachers, 253 parents, and 389 students from 3 cities and 5 counties in CholaBukDo. A questionnaire which was made by the researcher was used as an instrument for this study. The results are as follows: Of 32 contents on Family life subarea, all the teachers, the parents and the students put the emphasis on sex such as pregnancy, purity, sex-ethics, etc. This result means that middle-school students emphasized the sexual identity formation and this was also a common concern about adolescents in our society. Of 37 contents of Managing home resource and Consumer life subarea, teachers though the environment pollution is an important subject and parents and students thought finding a method to conserve good environment were more important. This result reflects their concern on the environment. Of 49 contents on Dietary life, teachers and parents emphasized “the importance of nutritive elements”which is basic on their dietary life and students were more interested in “adolescence and growth and development among adolescents’nutritional characteristics and problems”which is more related to their current life. Of 40 contents on Clothing life subarea, while teachers put the emphasis on the method how they can buy ready-made clothes, parents and students wanted them to teach what kind of clothes are suitable for themselves. Of 18 contents on Residing life subarea, teachers emphasized the importance of ventilation for adjusting the room environment and students were more interested in the effective use of the residing space. By finding out what kinds of Home-economics contents are important from the view point of teachers, parents and students, this study can be a useful resource for the next curriculum revision and for selecting contents of a new-coming text book. However, restricted sampling must be considered and further studies which cover the whole area might be needed.

  • PDF

Respiratory Air Flow Transducer Applicable to Cardiopulmonary Resuscitation Procedure (인공심폐소생술에 활용 가능한 호흡기류센서)

  • Kim, Kyung-Ah;Lee, In-Kwang;Lee, You-Mi;Yu, Hee;Kim, Young-Il;Han, Sang-Hyun;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.833-839
    • /
    • 2013
  • Cardiopulmonary resuscitation (CPR) is performed by thoracic compression and artificial ventilation for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are facing the whole area perpendicular to the flow axis. The present study developed a new air flow transducer conveniently applicable to CPR. Specially designed "sensing rod" samples the air velocity at 3 different locations of the flow cross-section, then transforms into average dynamic pressure by the Bernoulli's law. The symmetric structure of the sensing holes of the sensing rod enables bi-directional measurement simply by taking the difference in pressure by a commercial differential pressure transducer. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

An Assessment of Korean Housewives Exposed to Polycyclic Aromatic Hydrocabons(PAHs) in Indoor Air (일부 주부의 실내공기 중 PAHs 노출에 관한 연구)

  • Lee, Tae-Hyung;Kim, Yun-Sin;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.323-331
    • /
    • 2007
  • Polycyclic aromatic hydrocarbons (PAHs) are well known for strong carcinogen. However, the human exposure analysis of PAHs is quite difficult and unreliable because of hard for estimation of actual expose dose. Then urinary 1-hydroxypyrene (1-OHP) has been a biological marker of exposure to PAHs. The purpose of this study was to investigate total amount from exposure to PAHs soused by indoor occupational exposure, and residence at Seoul metropolitan area and Kyeonggi province in Korea. Thirty-five housewives were included in this study from April 2003 through February 2004. Dietary habit and general characteristics such as age, type of building, existence of passive smoking, period of residence, fuel type for heating and ventilation type were obtained by self administered questionnaire. Urine samples were collected at morning and freeze quickly. Urinary creatinine was measured for converting into 24 hr urine. Concentration of the indoor PAHs was examined by NIOSH method number 5506. Urinary 1-OHP and PAHs were analysed by HPLC. Correlation coefficient between urinary 1-OHP levels and pyrene concentration of indoor air was 0.66 and statistically significant(P<0.01). The difference of urinary 1-OHP level due to dietary habits were not significant. Urinary 1-OHP level of Spring, Summer, Autumn, and Winter were $0.21{\pm}0.12,\;0.10{\pm}0.17,\;0.16{\pm}0.12,\;0.17{\pm}0.14{\mu}g/g$ cr, respectively. The arithmetic means of urinary 1-OHP for four season tee $0.16{\pm}0.14 {\mu}g/g$ cr. There was a trend that urinary 1-OHP level of residents who dwelling in apartment were higher compared with detached home, Comparison of 1-OHP level between heating by kerosene and LPG, Much higher gas heating type than kerosene type (P<0.05). This result implies that the urinary 1-OHP can be applied as the PAHs exposure indices.

A Study on Pattern of Introducing the Nature into Interior & Exterior of Modern Architecture - Focusing on Water and Plant - (현대건축 내.외부에 나타나는 자연도입 유형에 관한 연구 - 물과 식물을 중심으로 -)

  • Kang, Hee;Hur, Yong-Seok;Hur, Bum-Pall
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.1
    • /
    • pp.46-54
    • /
    • 2010
  • Since the accomplishment of industrialization and mechanization, human and the nature have gone farther their own way. Human depending on technology have been increasingly expanding and developing their artificial space and as times go by in such a way, estrangement between the human and nature has resulted in dissatisfaction of human's instinctual desire and devastation of human's living. People, to deal with such challenge, begins taking a look at the nature. In introducing the nature into the modern architecture, a physical natural element is often directly taken into or the shape that could be inferred from the nature is taken. The study was intended to identify the characteristics of the pattern introducing the nature into the modern architecture, as mentioned in the former case, which is summarized as follows, Introduction of the nature contains a variety of functions in the space and it creates the new space by integrating the internal and external space which becomes boundaryless integrated space. The boundary in the building tends to be getting more ambiguous, while the space accommodating the nature serves the interface, playing a role of intermediator for both the internal and external space. It functions the open public place that helps build the natural community among the users but taking the nature into the inner space, and it is used to attempt to change the interior of the building or for ventilation lighting or energy-saving purpose. The spatial meaning was found to have varied depending on pattern of the nature introduced. Such conclusions mentioned hereon is expected to help forecast and understand the forthcoming space accommodating the nature when reviewing the pattern of introducing the nature appeared In modern architecture.

A study on cross sectional characteristics and available area for using the lower space in TBM road tunnels (TBM 도로터널의 단면특성 및 하부공간 활용을 위한 유효면적 검토)

  • Kim, Hyun-Soo;Kim, Hong-Moon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.2
    • /
    • pp.141-157
    • /
    • 2012
  • For the application TBM tunneling method, Both tunnel design standard and case study designed & constructed in domestic and foreign have been conducted. According to the study, the number of lane and inner shape (single or duplex) vary depending on the volume of traffic. Also extra space located in the top and bottom of tunnel is used for a multipurpose such as ventilation, disaster prevention, maintenance and administration. To find area ratio according to the components of road TBM tunnel, a standard section was considered as a two-lane road. Then, the analysis of area ratio of this section which consists of components for clearance, extra space in upper and lower tunnel was carried on two widths of shoulder. In addition, after a structural analysis, a thickness requirement of lower slab which is essential for road tunnel was derived on a few supporting types. Through correlation analysis, the ranges of available cross-sectional area between slab thickness and lower extra space of the tunnel was presented.

Clinical courses and diagnoses of neonates who are transferred due to mild respiratory distress soon after birth in a university hospital (일개 대학병원에서 출생 초기 경미한 호흡곤란을 주소로 전원된 신생아의 임상경과 및 진단)

  • Seo, Jee Hyue;Lee, Kyo Ho;Lee, Eun Sil
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.89-93
    • /
    • 2014
  • Background: This study was conducted to investigate the epidemiological features, clinical courses, and diagnoses of neonates who are transferred to neonatal intensive care unit of Yeungnam University Hospital due to tachypnea soon after birth. Methods: Based on medical records, we performed a retrospective study of neonatal intensive care unit admissions due to tachypnea from January 2010 to December 2013. Results: A total of 311 neonates were included in this study. The patient characteristics showed male predominance at 2.65:1. Among the 311 neonates with tachypnea, 127 (40.8%) neonates needed oxygen supply, and 54 (17.4%) neonates needed assisted mechanical ventilation. Transient tachypnea of the newborns (TTN) (158, 50.8%) showed the highest incidence, followed by pneumonia (63, 20.3%), extrapulmonary infection (37, 11.9%), respiratory distress syndrome (21, 6.8%), air leak (16, 5.1%), meconium aspiration syndrome (12, 3.9%), congenital heart disease (5, 1.6%), metabolic acidosis (3, 1%), primary pulmonary hypertension of newborns (2, 0.6%) and anemia (2, 0.6%). Conclusion: Although the neonates with tachypnea showed no other respiratory distress symptom, clinicians should be aware of the possibility of other pulmonary diseases as well as TTN and their extra-pulmonary causes. If tachypnea does not improve within a few hours, the clinician should consider further evaluation and management as soon as possible.

A Study on the Wind Pressure Coefficients of Flat-type Apartment Complexes Considering Building Layout and Aspect Ratio (판상형 공동주택의 동 배치 및 종횡비에 따른 풍압계수 특성에 관한 연구)

  • Yoon, Seong-Hoon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.9
    • /
    • pp.153-159
    • /
    • 2021
  • In this study, basic data that can be referenced for ventilation modeling was presented by analyzing the characteristics of wind pressure coefficients(Cp) according to wind direction angles under conditions of different building layouts and aspect ratios through CFD (Computational Fluid Dynamics) analysis for flat-type apartment complexes. In the case of a wind direction angle of 0°, Cp distribution in the form of an inverted S-shape was shown on the front of the building located on the windward side. And Cp corresponding to the lowest floor, the uppermost floor, and the two inflection points showed relatively close values regardless of the height of the building. The inflection point of the low-rise part was formed at a height of about 11m, and the height of the high-rise part could be calculated through a trend formula proportional to the height of the building. It was confirmed that the averaged Cp value can be applied in most conditions except for the wind direction angle of 45 degrees.

Outcomes after Extracorporeal Membrane Oxygenation in Neonates with Congenital Diaphragmatic Hernia: A Single-Center Experience

  • Choi, Wooseok;Cho, Won Chul;Choi, Eun Seok;Yun, Tae-Jin;Park, Chun Soo
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.348-355
    • /
    • 2021
  • Background: Congenital diaphragmatic hernia (CDH) is a rare disease often requiring mechanical ventilation after birth. In severe cases, extracorporeal membrane oxygenation (ECMO) may be needed. This study analyzed the outcomes of patients with CDH treated with ECMO and investigated factors related to in-hospital mortality. Methods: Among 254 newborns diagnosed with CDH between 2008 and 2020, 51 patients needed ECMO support. At Asan Medical Center, a multidisciplinary team approach has been applied for managing newborns with CDH since 2018. Outcomes were compared between hospital survivors and nonsurvivors. Results: ECMO was established at a median of 17 hours after birth. The mean birth weight was 3.1±0.5 kg. Twenty-three patients (23/51, 45.1%) were weaned from ECMO, and 16 patients (16/51, 31.4%) survived to discharge. The ECMO mode was veno-venous in 24 patients (47.1%) and veno-arterial in 27 patients (52.9%). Most cannulations (50/51, 98%) were accomplished through a transverse cervical incision. No significant between-group differences in baseline characteristics and prenatal indices were observed. The oxygenation index (1 hour before: 90.0 vs. 51.0, p=0.005) and blood lactate level (peak: 7.9 vs. 5.2 mmol/L, p=0.023) before ECMO were higher in nonsurvivors. Major bleeding during ECMO more frequently occurred in nonsurvivors (57.1% vs. 12.5%, p=0.007). In the multivariate analysis, the oxygenation index measured at 1 hour before ECMO initiation was identified as a significant risk factor for in-hospital mortality (odds ratio, 1.02; 95% confidence interval, 1.01-1.04; p=0.05). Conclusion: The survival of neonates after ECMO for CDH is suboptimal. Timely application of ECMO is crucial for better survival outcomes.

Occurrence and distribution of indoor volatile organic compounds in residential spaces by sampling methods (시료채취 방식에 따른 주거 공간 내 휘발성유기화합물 발생 특성 평가)

  • Lee, Suyeon;Kim, Daekeun
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.362-371
    • /
    • 2018
  • Indoor Volatile organic compounds (VOCs) are classified as known or possible toxicants and odorants. This study characterized VOC levels in 11 homes in an area in the capital of Seoul by using two different methods of VOCs sampling, which are the active sampling using a thermal sorption tube and the passive sampling using a diffusion sampler. When using the active sampling method, the total target VOC concentration ranged from 41.7 to $420.7{\mu}g/m^3$ (mean $230.4{\mu}g/m^3$ ; median $221.8{\mu}g/m^3$) during winter and 21.3 to $1,431.9{\mu}g/m^3$ (mean $340.1{\mu}g/m^3$; median $175.4{\mu}g/m^3$) during summer. When using the passive method, 29.6 to $257.5{\mu}g/m^3$ (mean $81.8{\mu}g/m^3$; median $49.4{\mu}g/m^3$) during winter and 1.2 to $5,131.1{\mu}g/m^3$ (mean $1,758.8{\mu}g/m^3$; median $1,375.1{\mu}g/m^3$) during summer. Forty-nine VOCs were quantified and toluene showed the highest concentration regardless of the season and the sampling method studied. The distribution of VOCs was relatively varied by using the active method. However, it showed a low correlation with indoor environmental factors such as room temperature, humidity and ventilation time. The correlation between indoor environmental factors and VOCs were relatively high in the passive method. In particular, these characteristics were confirmed by principal component analysis.

An Analysis of Façade Panel Characteristics of UN Studio's Office Projects (유엔스튜디오 업무시설 외피 패널의 형태적 특성 분석)

  • Ko, Sung Hak
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.8
    • /
    • pp.23-34
    • /
    • 2019
  • The façade, a fundamental function as a skin that protects human life from external environment such as cold and hot weather, snow, rain, and wind, etc, has served as a media for communication between indoor space of the building and outside space. From the media for communication point of view, the approach to envelope design, in which environmental elements are transmitted internally through the filtering of external environments, has been evolving in various ways from the past to the present. Today, modern architecture technologies including curtain wall systems and user-friendly computer programming and environmental analysis programs demonstrate a differentiated approach to envelope design related to the indoor environment. For this reason, it is worth noting that the envelope design factors and trends that appear variously in the UNStudio's projects before and after the 2000s. The factors reflected in the envelop design in conjunction with the indoor environment obtained through the case study of the UNStudio's office projects were daylight environment, thermal environment, ventilation, noise, privacy and view, and consideration for daylight environment and thermal environment was reflected in many cases through the case study. Looking at the changes in the diagrams in order of year, it can be seen that the envelope design using the environmental analysis tool has been performed since 2006. This is a clue to show the envelop design changes from the conceptual method to the data-based one. The diagrams and analysis results related to the envelop design showed that the thermal environment related to solar radiation was the most, and no diagrams and analysis related to the indoor illumination were found. Since 2010, PV panel installation has been shown in the envelope design, which can be found in the increased efficiency of PV panels due to the technological advances and the decrease in production cost.