• 제목/요약/키워드: Vent Mode

검색결과 21건 처리시간 0.024초

CFX를 이용한 내부순환모드에서의 자동차 내부 유동특성 연구 (A study on Flow Characteristic inside Passenger's Compartment under Recirculation Cool vent mode using CFX)

  • 김윤기;양장식;김경천;지호성
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.25-30
    • /
    • 2010
  • The flow characteristics under recirculation cool vent mode is numerically studied using commercial fluid dynamic code(CFX). For the reliable analysis, real vehicle and human FE model is employed in grid generation process. The geometrical location and shape of panel vent, and exhaust vent is set as that of real vehicle model. The flowrate of the working fluid is determined as 330CMH which is equivalent to 70 percent of maximum capacity of HVAC system. The high velocity regions are formed around 4 each panel vent. Because of the non-symmetrically located exhaust, non-uniform flow and partial backflow near the door trim is observed. Streaklines start from each panel vent show the flow pattern of the airflow in the passenger's compartment very well.

자동차 워셔펌프의 통기구 유무에 따른 작동내구 특성 분석 (Analysis Study on Durability Properties of Washer Pump with Vent Hole)

  • 이상훈;위신환;김성우;김규로
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권1호
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the failure mechanism of the washer pump to find what is the failure cause in the road environment. The statistics show the field common failure mode is inner corrosion. The failure mechanism is assumed that the inner part of washer pump is corroded due to inflow of moisture through vent hole. To prevent the failure, we can think a method that is covering the vent hole. In general, the vent hole is designed to play an important role in an automobile parts. So, we need to prove the vent hole is not necessary. The first purpose of this paper is to make sure that the vent hole does not affect the durability of washer pump using the analysis of operating condition. The second purpose is to compare the durability properties if the vent hole is covered.

연료 벤트/릴리프 밸브의 설계 분석 (Design review of fuel vent-relief valve)

  • 장제선;길경섭;한상엽;박종호
    • 항공우주기술
    • /
    • 제11권2호
    • /
    • pp.109-116
    • /
    • 2012
  • 우주발사체의 액체추진공급시스템에서 사용되는 연료 벤트/릴리프밸브는 안전밸브의 조합체로 지상에서 연료를 주입할 때와 비행 중에 추진제 탱크의 과압을 해소하는 역할을 한다. 벤트/릴리프밸브는 구동가스 공급에 의해 벤트밸브를 작동시키는 벤트모드와 설정된 압력을 유지하기 위해 자동으로 밸브를 개폐하는 릴리프모드로 작동한다. 본 논문에서는 해외발사체에 사용된(Saturn) 벤트/릴리프밸브 샘플을 이용하여 한국형발사체의 규격에 적용한 밸브 설계를 검토하였다. 또한 설계 검증 및 기본적인 작동 특성을 분석하기 위해 AMESim 상용코드를 이용하여 해석 모델을 구성하였다. 밸브 모델을 이용해서 동특성 해석을 수행하여 설계 변수에 대해 밸브 개폐 작동시간, 작동성능, 개폐압력을 예상하였다. 이를 통해 연료 벤트/릴리프밸브 설계변수에 따른 작동성을 파악하여 시제품 제작 전 의 상세설계 및 설계 경계조건을 제시하였다.

TLC와 컬러화상처리를 이용한 자동차 실내 환기유동의 온도장 측정 (Temperature Field Measurement of Ventilation Flow in a Vehicle Interior)

  • 윤정환;이상준;김기원
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.120-128
    • /
    • 1997
  • The variations of the temperature field in a passenger compartment were measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. This temperature measurement technique was proved to be useful for analyzing the ventilation flow. The flow field in the passenger compartment was visualized using a particle streak method with pulsed laser light sheet. The temperature field and flow field in the passenger copartment were affected significantly by the ventilation mode. The panel-vent mode heating had shorter elapse time to reach a uniform temperature than the foot-vent mode under the same ventilation condition and nonuniformity inside the passenger compartment could be minimized effectively by using the bilevel heating mode. The temperature increase rate in the rear passenger compartment was iower than the front compartment, especially in the vicinity of the rear seat occupants' knee level.

  • PDF

산화제 탱크 2단계 압력 설정을 위한 벤트/릴리프밸브 설계 (Design of Vent Relief Valve for Bi-level Pressure Setting of Oxidizer Tank)

  • 고현석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1051-1053
    • /
    • 2017
  • 2단계 압력 설정이 가능하도록 산화제 탱크용 벤트/릴리프밸브를 설계하였다. 압력 편차를 줄이기 위하여 최소 캐비티 부피를 계산하였고 모델링을 활용하여 밸브 작동 특성을 해석하였다. 해석 결과를 토대로 검증을 위한 시제품을 제작할 예정이다.

  • PDF

차량용 공조덕트의 소음특성에 관한 연구 (Characteristics of noise in HVAC duct for vehicle)

  • 김재원;김진민;박정영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.529-534
    • /
    • 2003
  • Comprehensive study on the system, including blower and ducts, of HVAC device of a vehicle has been carried out for improvements of noise characteristics. The parameters of design improvements are concerned with geometric informations such as the shape of ducts and presence of a windshield window. Test results show that noise level increasing the following order: HV (HD) < V (D) < BH ${\sim}$ BHV (BHD) < B (B, H, V, D denote for blower, heater unit, vent duct, defrost duct, respectively). The effects of windshield glass on the noise level in the case of defrost mode are pronounced and the effects of the geometry of ducts on the overall HVAC noise prove to be not small.

  • PDF

강제환기 통풍구가 설치된 철도터널 열차화재에서 연기거동에 관한 수치해석적 연구 (Numerical study for smoke behavior in case of train fires in railway tunnel with axial fan vents)

  • 김동현;신민호;문정주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1998-2004
    • /
    • 2003
  • Numerical study were performed to analyze for fire safety in railway tunnel with forced ventilation vents. For the condition of train fires with heat release rate of 30 MW, unsteady three dimensional analysis were carried out to investigate the effects of smoke movements, the heat transfer and $CO_2$ concentrations and in double track tunnel with two vents. Among three operation modes of forced ventilations at two vents, the exhaust-exhaust mode of the vent represents the best performance for the evacuation of passengers to avoid the fire.

  • PDF

디스크 브레이크의 마찰열 접촉거동에 관한 트라이볼로지적 연구 - 벤트홀의 방열효과를 중심으로 - (Tribological Analysis on the Contact Behaviors of Disk Brakes Due to Frictional Heatings -Cooling Effects By Vent Holes-)

  • 김청균;황준태
    • Tribology and Lubricants
    • /
    • 제15권2호
    • /
    • pp.199-205
    • /
    • 1999
  • Using a coupled thermal-mechanical analysis, the thermal distortion of the ventilated disk brakes has been investigated based on the air cooling effects during 15 braking operations. The FEM results show that the bendings and distortions of the disk toward the left side are decreased, but the sinusoidal distortion of the disk rubbing surface along the arc length of the vent hole is highly increased by increasing the convective air cooling effects, which is heavily related to the squeal, wear and micro-thermal crackings at the rubbing surfaces due to uneven dissipation rates of friction heatings.

차량 내부 탑승자의 쾌적성 평가를 위한 초기 냉방운전 성능에 대한 수치해석적 연구 (Numerical Analysis on the Initial Cool-down Performance Inside an Automobile for the Evaluation of Passenger's Thermal Comfort)

  • 김윤기;양장식;백제현;김경천;지호성
    • 한국자동차공학회논문집
    • /
    • 제18권5호
    • /
    • pp.115-123
    • /
    • 2010
  • Cool-down performance after soaking is important because it affects passenger's thermal comfort. The cooling capacity of HVAC system determines initial cool down performance in most cases, the performance is also affected by location, and shape of panel vent, indoor seat arrangement. Therefore, optimal indoor designs are required in developing a new car. In this paper, initial cool down performance is predicted by CFD(computational fluid dynamics) analysis. Experimental time-averaging temperature data are used as inlet boundary condition. For more reliable analysis, real vehicle model and human FE model are used in grid generation procedure. Thermal and aerodynamic characteristics on re-circulation cool vent mode are investigated using CFX 12.0. Thermal comfort represented by PMV(predicted mean vote) is evaluated using acquired numerical data. Temperature and velocity fields show that flow in passenger's compartment after soaking is considerably unstable at the view point of thermodynamics. Volume-averaged temperature is decreased exponentially during overall cool down process. However, temperature monitored at different 16 spots in CFX-Solver shows local variation in head, chest, knee, foot. The cooling speed at the head and chest nearby panel vent are relatively faster than at the knee and foot. Horizontal temperature contour shows asymmetric distribution because of the location of exhaust vent. By evaluating the passenger's thermal comfort, slowest cooling region is found at the driver's seat.

거대 화상용 PIV 시스템을 이용한 실차 내부 공기벨트 토출흐름의 속도장 측정 연구 (PIV Measurements of Ventilation Flow from the Air Vent of a Real Passenger Car)

  • 이진평;김학림;이상준
    • 한국가시화정보학회지
    • /
    • 제7권1호
    • /
    • pp.3-8
    • /
    • 2009
  • Most vehicles have a heating, ventilating and air conditioning (HVAC) device to control the thermal condition and to make comfortable environment in the passenger compartment. The improvement of ventilation flow inside the passenger compartment is crucial for providing comfortable environment. For this, better understanding on the variation of flow characteristics of ventilation air inside the passenger compartment with respect to various ventilation modes is strongly required. Most previous studies on the ventilation flow in a car cabin were carried out using computational fluid dynamics (CFD) analysis or scale-down water-model experiments. In this study, whole ventilation flow discharged from the air vent of a real passenger car was measured using a special PIV (particle image velocimetry) system for large-size FOV (field of view). Under real recirculation ventilation condition, the spatial distributions of stream-wise turbulence intensity and mean velocity were measured in the vortical panel-duct center plane under the panel ventilation mode. These experimental data would be useful for understanding the detailed flow structure of real ventilation flow and validating numerical predictions.