• Title/Summary/Keyword: Vent Analysis

Search Result 158, Processing Time 0.025 seconds

Tribological Analysis on the Contact Behaviors of Disk Brakes Due to Frictional Heatings -Cooling Effects By Vent Holes- (디스크 브레이크의 마찰열 접촉거동에 관한 트라이볼로지적 연구 - 벤트홀의 방열효과를 중심으로 -)

  • 김청균;황준태
    • Tribology and Lubricants
    • /
    • v.15 no.2
    • /
    • pp.199-205
    • /
    • 1999
  • Using a coupled thermal-mechanical analysis, the thermal distortion of the ventilated disk brakes has been investigated based on the air cooling effects during 15 braking operations. The FEM results show that the bendings and distortions of the disk toward the left side are decreased, but the sinusoidal distortion of the disk rubbing surface along the arc length of the vent hole is highly increased by increasing the convective air cooling effects, which is heavily related to the squeal, wear and micro-thermal crackings at the rubbing surfaces due to uneven dissipation rates of friction heatings.

Acoustic and Electrical Analysis of Microspeaker for Mobile Phones (모바일 폰용 마이크로스피커의 음향 및 전기 해석)

  • Park, Seok-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.525-536
    • /
    • 2014
  • In this paper, GUI program for microspeaker system simulation program was developed and verified through closed box, vent box and 6th order bandpass enclosure system. By using the pseudo loudspeaker model concept, TS parameters and rear volume of microspeaker were identified. Their suitabilities were proved by comparing test results with simulations of electrical impedance and sound pressure response curves for the three box types; closed box, vent box and 6th order bandpass box. Also, MSSP was found to be effective regardless of the microspeaker's shape, either circular or rectangular shape. MSSP can be used for the microspeaker system simulation, and can give a general prediction of such as; sound pressure level curve, electrical impedance, diaphragm velocity and displacement curve according to multiple design parameters; diaphragm mass, compliance, force factor, front and rear volume, front and rear port's diameter and length.

Thermal Fluid Flow and Deformation Analysis of Medium Commercial Vehicle Ventilated Brake Disc in Braking (중형 상용차 통풍형 브레이크 디스크의 제동 시 열 유동 및 변형 해석)

  • Kang, Chaeuk;Choi, Gyoojae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.63-69
    • /
    • 2014
  • Domestic automobile companies have adopted drum type brake system for commercial vehicles. However recently those companies have been applying disc-brake system to solve vehicle control-instability and inefficient heat discharge performance of conventional drum brake system for a medium commercial vehicle. Because the kinetic energy of a running commercial vehicle is relatively high, the brake system should discharge lots of heat energy while braking. A ventilated type brake disc has been used to increase heat discharge performance of a brake system. The vent structure of a disc highly affects cooling efficiency. This paper compares thermal characteristics of three types of vent structure in JASO C421 braking condition. It is found that the slant bend type disc has the lowest temperature and thermal stress distributions in the braking condition.

Analysis of studies on the by-products of the Broussonetia kazinoki Siebold or Broussonetia papyrifera (L.) Vent. (닥나무 부산물에 대한 문헌 연구)

  • Lee, Nam-Hun;Ha, Hye-Kyung;Lee, Ho-Young;Jung, Da-Young;Choi, Ji-Yoon;Choi, Young-Jae;Jeong, Seung-Il;Shin, Hyun-Kyoo
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.1
    • /
    • pp.49-58
    • /
    • 2008
  • Objective : To provide information about the accessory product of Broussonetia kazinoki Siebold or Broussonetia papyrifera (L.) Vent by analyzing old books of oriental medicine, domestic/international papers and related patents Methods : Old books related to the accessory product in the field of oriental medicine were reviewed. Research papers regarding the pharmacological activity of the by-products were reviewed and analyzed. Patents about the residual products were examined and classified by year and subject Results : Seven kinds of by-products from Broussonetia kazinoki Siebold or Broussonetia papyrifera (L.) Vent has been used as medicines in oriental medicine. Recently, anti-oxidating, anti-cancer, anti-mutagenic and anti-inflammation activity of the residual product of these plants has been investigated through scientific research. There were 19 patents related with the accessory products of these plants, which were in the subjects of functional cosmetics, anti-inflammation, cleansing goods, hair restorers or improvement of learning ability. Further investigations about the activity of these plants are needed in bone metabolism, water balance and hemostasis in the future. Conclusion : Residual products from these plants is being used in various ways. However, more studies on the efficacy and mechanism, as well as safety, of these plants should be conducted precisely in the future.

  • PDF

Comparison of CTD Cast and CTD Tow-yo Methods for Detecting Hydrothermal Plume (열수 플룸 검출을 위한 CTD Cast와 CTD Tow-yo 방법 비교)

  • Son, Juwon;Joo, Jongmin;Ham, Dong Jin;Yang, Seungjin;Kim, Jonguk
    • Ocean and Polar Research
    • /
    • v.36 no.2
    • /
    • pp.179-187
    • /
    • 2014
  • Directly searching for undiscovered hydrothermal vent sites is inefficient due to the practical difficulty of comprehensively imaging vent fields. Thus, most searches for hydrothermal vent sites rely on the detection of hydrothermal plumes from water column observation. Detecting and measuring the hydrothermal plumes are the most efficient way to infer the presence and distribution of hydrothermal vents. Both the array of vertical casting and lateral towing are the most common methods to discover hydrothermal plumes. In this study, we compared results of cast and tow-yo operations along the same section of a spreading center with a distance of 20.5 km in the North Fiji Basin for mapping hydrothermal plumes. Operation of CTD tow-yo provides a detailed pattern of plumes which enable us to locate the hydrothermal vents. On the other hand, identification of hydrothermal activity can be determined effectively by CTD cast with additional analysis of geochemical tracers. Reduction in the operating time is another advantage of CTD cast operation, especially for regional-scale survey. Our results show that the combination of CTD cast and tow-yo would improve the efficiency of the hydrothermal plume survey to locate new hydrothermal vent sites.

3D GEOMETRY EFFECTS ANALYSIS ON PROPAGATION OF PRESSURE WAVE GENERATED BY HIGH-SPEED TRAIN TRAVELING IN A TUNNEL USING CFD (3차원 형상을 고려한 고속철도에 의한 터널내 압력파 전파의 CFD 해석)

  • Shin, D.Y.;Lee, S.G.;Oh, H.J.;Kim, H.G.;Yoon, S.H.;Kim, C.J.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.49-55
    • /
    • 2012
  • Research has importance in proposing the design of a tunnel with a vertical vent to secure passengers in a comfortable environment and safe against pressure. Using several analysis methods, the magnitude of the pressure induced by the vertical vent in the tunnel can be analyzed. In addition to the 3-dimensional method, the 2-dimensional method and the 2-dimensional axis-symmetric method are also used to analyze the strong and weak points of each so that the optimum analysis method can be obtained. As a result, it appears that the 2-dimensional axis-symmetric method is the most suitable in analyzing tunnel pressure consider to accuracy and time effective aspect. Also, the 3-dimensional method is disadvantageous in that it takes longer in calculating results, but is more effective in predicting phenomena around the vertical vent in the tunnel.

Thermal and Fluid Analysis on Air Distribution in a Elevator Car (엘리베이터 카 내부 기류분포에 관한 열 유동해석)

  • Chung, Kyung Taek;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.1
    • /
    • pp.56-62
    • /
    • 2020
  • The purpose of this study is to observe the visualization of the flow field for air flow distributed in the car from the ventilation fan installed in the ceiling of the passenger elevator car through the numerical analysis using computational fluid dynamics. STAR-CCM+, which is a code used for the numerical analysis, was used to predict the airflow distribution inside the elevator car. The numerical analysis of the distribution of the air current in the elevator was carried out. As a result, the analysis results for each point and the visualization of the air current distribution and the temperature distribution in the elevator car and were obtained. It was found that heat transfer was actively occurring inside the car due to the influence of the flow field discharged from the ventilation vent installed in the ceiling in the elevator car, and especially the convection heat transfer of Model-2 was more active than that of Model-1. As a result, the temperature distribution inside the car was found to be relatively low. In addition, the temperature distribution at a cross-section of 1700mm height in the elevator car shows that Model-2 is the location of the ventilation vent which makes people feel more comfortable.

An Analysis of the Loss of Residual Heat Removal System Event for Pressurized Water Reactor at Reduced Inventory Operation (가압경수로의 저수위 운전시 잔열제거계통 상실사고에 대한 분석)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.645-660
    • /
    • 1995
  • The loss of Residual Heat Removal System (RHRS) event during reduced inventory operation for the Korean Standard Nuclear Power Plants (KSNPPS) is simulated by RELAP5/MOD3 and RELAP5/MOD3.1 Tn cases are considered : Base case for an intact Reactor Coolant System (RCS) with no tent and a vent case for an open system. Comparative simulations of base case are peformed by RELAP5/MOD3 and RELAP5/MOD3. 1 computer codes. The results of too simulations are generally in good qualitative and quantitative agreement. However, since the results of RELAP5/MOD3 simulation reveals the deficiency of RELAP5/MOD3 wall heat model, the RELAP5/AOD3.1 computer code is used for the simulation of the vent case. The analysis result of base case show that two steam generators are insufficient to remove decay heat at one day after shutdown, where the RCS is closed. The RCS pressure increased continuously and reached the RCS temporary boundaries design pressure of 0.24 MPa around 4,000 seconds. In the vent case with a flow capacity equivalent to three times the capacity of Pressurizer Safety Valve (PSV), it is shown that the RCS Pressure does not reach 0.24 MPa and core uncovery does not occur until 10,000 seconds. The detailed discussions on the results of this study suggest the feasibility of RELAP5/AOD3.1 as an analysis tool for the simulation of the loss of RHRS event at reduced inventory operation. The results of this study also provide insight for the determination of proper vent capacity.

  • PDF

Simplified Modeling of Deflagration in Vessels

  • Kim, Joon-Hyun;Kim, Joo-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1338-1348
    • /
    • 2004
  • A simplified method that models the deflagration process occurring in closed or vented vessels is described. When combustion occurs within the spherical or cylindrical vessels, the flame moves spherically or segmentally to the vessel periphery. The volume and area of each element along the propagating flame front are calculated by using simple geometrical rules. For instabilities and turbulence resulting in enhanced burning rates, a simple analysis results in reasonable agreement with the experimental pressure transients when two burning rates (a laminar burning rate prior to the onset of instability and an enhanced burning rate) were used. Pressure reduction caused by a vent opening at predetermined pressure was modeled. Parameters examined in the modeling include ignition location, mixture concentration, vented area, and vent opening pressure. It was found that venting was effective in reducing the peak pressure experienced in vessels. The model can be expected to estimate reasonable peak pressures and flame front distances by modeling the enhanced burning rates, that is, turbulent enhancement factor.

Flow Analysis of the Air Pocket in Draw Die (드로우 금형의 에어포켓 유출 유동해석)

  • Hwang, Se-Joon;Park, Warn-Gyu;Kim, Chul;Oh, Se-Wook;Cho, Nam-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.345-348
    • /
    • 2006
  • In sheet metal forming process using press and draw die some defect can be made because of the high pressure of air pocket between draw die and the product. The purpose of this study is to develop a program to decide an optimal combination of air vent hole size and number to prevent those defect on product. The air inside air pocket is considered as ideal gas and the compression and expansion is assumed as isentropic process. The mass flow is computed in two flow condition: unchocked and chocked condition. The present computation obtains required cross-sectional area of air vent hole for not exceeding the user specified pressure such as the pressure for yielding strength of the product or the pressure for unchocked flow. To validate the program the present results are compared with the results of other researchers and commercial CFD code.

  • PDF