공동주택에서의 실외 급.배기구 위치에 따른 환기효율 향상 연구 (A study on the Improvement of Ventilation Performance in Apartment House According to the Location of Exterior Air-Vents)

  • 박진철;유형규;차진영
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.71-79
    • /
    • 2005
  • In this study, the ventilation performance of mechanical ventilation system in apartment House was analyzed through model test according to characteristics of air-vent. Then adequate interval of air-vent was suggested using computer simulation which will create comfort environment through improvement of ventilation performance in apartment house. The result of experiment with separation plate to prevent mixture of contaminated exhaust air with fresh supply air, the ventilation efficiency improved about 10%. The result of simulation with horizontal location of exterior air-vent, contaminated exhaust air is mixed regardless of interval variation. Consequently, mixture of the exhaust air can be prevented through locating the supply air vent on the top side and exhaust air vent on the lower side.

급기구 형상에 따른 겨울철 실내 온열환경의 비교 (Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations)

  • 한화택;정영균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

Double Vent 창호 시스템의 단열성능평가 (The Evaluation of Thermal Performance of Double Vent Window System)

  • 유승호;박진우;문현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.557-560
    • /
    • 2008
  • Window system is an essential component for ventilation, lighting, and thermal environment in buildings. However, window system has the lowest insulation performance and may cause high energy consumptions, if it is not properly designed. Thus, performance of window systems play an important role in built environment. This study proposes a new window systems for balcony, which has double vents and analyses the thermal performance using an intergrated simulation method with Therm 6.1 and Widow 6.1. The result shows higher U-factor than conventional window systems. It is expected that the double vent window system can increase thermal performance and save energy in apartment houses.

  • PDF

발사체용 추진제 탱크 벤트릴리프 밸브 기술 동향 (Technology Trend of Propellant Tank Vent Relief Valve for Launch Vehicle)

  • 고현석
    • 항공우주산업기술동향
    • /
    • 제9권1호
    • /
    • pp.130-138
    • /
    • 2011
  • 벤트릴리프 밸브는 추진제 탱크의 충전 중 내부의 기체를 배출시키고 충전이 완료된 후에는 탱크의 과압을 해소하는 안전밸브의 역할을 수행한다. 신뢰성과 비용 절감 차원에서 모든 미국의 극저온 액체 추진제를 사용하는 발사체에서는 거의 유사한 벤트릴리프 밸브를 적용해오고 있다. 그리고 발사체의 다양한 임무요구조건을 만족하기 위하여 밸브를 다소 수정하여 사용해오고 있다. 본 논문에서는 발사체 추진제 공급 시스템에 적용되는 벤트릴리프 밸브의 설계 및 제작과 관련한 핵심 기술 동향을 살펴본다. 그리고 우주개발 선진국 발사체에 사용된 벤트릴리프밸브의 운용기술을 소개한다.

  • PDF

밀폐공간에서 파열면에 따른 가스폭발특성에 관한 연구 (A study on the characteristics of gas explosion with vent area)

  • 김상섭;채재우;조영도;장기현
    • 한국가스학회지
    • /
    • 제7권4호
    • /
    • pp.53-60
    • /
    • 2003
  • 보통 가정이나 건물에서 화재 및 가스에 의한 사고 중에 가스의 폭발에 의한 사고는 폭발과 동시에 발생하는 압력 때문에 발생하는 건물의 붕괴로서 많은 인명피해 및 재산상의 손해를 가져온다. 이와 같은 2차적인 피해를 막기 위해 본 연구에서는 건물의 폭발시 발생하는 개구부의 크기 및 형태에 따른 모델을 선정하여 건물의 체적대비 개구부 면적에 따른 압력변화를 실험을 통하여 개구부의 면적 비를 도출하였으며, 개구부 형태에 따른 압력실험을 통하여 최소의 압력으로 피해을 막을 수 있는 모델을 선정하였다. 이를 이용하여 건물의 설계시 안전율을 고려하여 개구부의 면적 및 형태를 선정함으로써 2차 피해를 예방할 수 있을 것으로 판단된다.

  • PDF

연동형 비닐하우스의 환기창 형태 조사 및 자연환기 효과 분석 (Field Survey and Analysis of Natural Ventilation Characteristics of Multi-span Greenhouse with Different Roof Vent)

  • 박민정;최덕규;손진관;윤성욱;김희태;이승기;강동현
    • 생물환경조절학회지
    • /
    • 제29권1호
    • /
    • pp.36-42
    • /
    • 2020
  • 본 연구에서는 국내에 가장 많이 보급되어 있는 1-2W 모델 연동온실에 대한 온실 규격 및 환기창 형태 실태 조사를 수행하고, 이를 바탕으로 연동온실의 천창 형태에 따른 유동 특성을 분석하기 위해 수치해석을 수행하여 자연환기효과를 분석하고자 하였다. 온실 실태조사 대상농가의 환기창면적 비율은 평균10%로 자연환기를 위한 시설면적 대비 환기창 면적 설계가 부족한 것으로 나타나 환기창 개선이 필요할 것으로 판단된다. 연동 온실의 천창 형태별 자연환기를 해석 및 분석한 결과, 온실 내 작물위치의 온도 분포 및 내외부 온도차는 몽골식 천창 온실에서 가장 낮고 외몽골식 천창 온실에서 가장 높게 나타났으나 추후 풍하중에 의한 구조적인 안전성을 평가해야할 것으로 판단된다.

상자포장 청과물의 송풍저항 특성 (Resistance to Air Flow through Packed Fruits and Vegetables in Vented Box)

  • 윤홍선;조영길;박경규
    • Journal of Biosystems Engineering
    • /
    • 제20권4호
    • /
    • pp.351-359
    • /
    • 1995
  • In pressure cooling system, produce were packed in vented box and cooled rapidly by producing a difference in air pressure on opposite faces of stacks of vented box. So, energy requirements and performance of pressure cooling system depended upon the air flow rate and the static pressure drop through packed produce in vented box. The static pressure drop across packed produce in vented box normally depended upon air flow rate, vent area of box and conditions of produce bed (depth, porosity, stacking patterns, size and shape of products) in box. The objectives of this study were to investigate the effect of vent area and air flow rate on airflow resistance of empty box and packed produce in vented box, and to investigate the relationship between the air flow resistance of packed products in vented box and sum of air flow resistance of empty box only and products in bulk only. Mandarins and tomatoes were used in the experiment. The airflow rate were in the range of 0.02~1.0$m^3$/s.$m^2$, the opening ratio of vent hole were in the range of 2.5~20% of the side area. The results were summerized as follows. 1. The pressure drops across vented box increased in proportion to superficial air velocity and decreased in proportion to opening ratio of vent hole. A regression equation to calculate airflow resistance of vented box was derived as a function of superficial air velocity and opening ratio of vent hole. 2. The pressure drops across packed produce in vented box increased in proportion to superficial air velocity and decreased in proportion to opening ratio of vent hole. 3. Because of the air velocity increase in the vicinity of vent hole in box, the airflow resistances of packed products in vented box were always higher than sum of air flow resistance of empty box only and products in bulk only. 4. Based on the airflow resistance of empty box and products in bulk, a regression equation to calculate airflow resistance of packed products in vented box was derived.

  • PDF

맨홀에 설치된 지역난방 열공급관 에어벤트의 전단부 파손 원인 규명 (Failure Analysis of Air Vent Connected with Heat Supply Pipeline Under Manhole)

  • 조정민;채호병;김희산;김정구;김우철;정준철;이수열
    • Corrosion Science and Technology
    • /
    • 제19권4호
    • /
    • pp.196-202
    • /
    • 2020
  • The air vent connected to a heat supply pipeline in the district heating system has been used to eliminate the existing air in the pipe, which has a detrimental effect on corrosion durability and heat efficiency. Recently, the air vent installed under a manhole for 22 years was corroded and several pinholes were detected in the front-end of the air vent. To identify the cause of the failure, thickness reduction, corrosion products, and water quality were examined. The corrosion damage was significant at the outside of the front-end of the air vent where the insulator was covered. While a thin oxide layer was formed in the interior of the tube, the coarse and porous corrosion products consisting of magnetite and hematite were found externally. Water flowing into the thermal insulator was absorbed by the insulator following hydrolysis. The hydrolyzed insulator ejected the corrosion factors such as Cl-, SO42-, and NH4+. The findings suggest that the corrosion under insulation due to rain water is the main cause of the underlying failure in the air vent.

FDS를 이용한 실규모 공연장 무대 내 화재 시 연기 거동 분석: 방화막 및 자연배출구 면적의 영향 (Analysis of Smoke Behavior in Fire within Real-scale Theater Using FDS: Influences of Fire Curtain and Natural Smoke Vent Area)

  • 김재한;이치영;정이규;김동균
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.7-14
    • /
    • 2018
  • 본 연구에서는 방화막 및 자연배출구 면적이 공연장 무대 화재 시 연기 거동에 미치는 영향에 대해 Fire Dynamics Simulator (FDS)를 이용하여 전산시뮬레이션(Numerical simulation)을 수행하였다. 공연장의 무대 크기는 폭 31 m, 깊이 34 m, 높이 32 m로 설정하였고, 자연배출구 면적은 무대 바닥면적의 약 10%, 약 8%, 약 5%, 약 1%로 하였다. 방화막은 프로시니엄(Proscenium) 벽과 0.5 m 이격하여 설정하였다. 방화막과 자연배출구 면적은 객석으로의 연기유출, 자연배출구 및 프로시니엄 개구부를 통한 유입 및 유출 질량 유량에 지대한 영향을 미치는 것으로 관찰되었고, 동일한 자연배출구 면적 조건에서 방화막이 설치된 경우가 미설치된 경우에 비해 무대 내 압력이 더 낮은 것으로 나타났다.