• Title/Summary/Keyword: Vehicle source

Search Result 657, Processing Time 0.03 seconds

Development of Korean RDE Routes for On-road Emissions Measurement of Light Duty Vehicles (소형자동차 실제도로 주행 배출가스 측정을 위한 국내 주행경로 개발)

  • Kang, Gunwoo;Lee, Jongtae;Park, Junhong;Cha, Junepyo;Chon, Mun Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.3
    • /
    • pp.287-296
    • /
    • 2017
  • Although emission regulations have been gradually strengthened in the past decade, the road transport section remains the most important source of NOx emission in air pollution. One reason is that there has been an increase in the proportion of diesel vehicles and in the volume of traffic. In addition, the certification procedure for standard emission limit does not sufficiently reflect real traffic condition and various driving patterns. Therefore, the European Commission(EC) has recently come up with the RDE-LDV(Real driving emissions-light duty vehicle) regulations, and the Ministry of Environment in Korea has been conducting research on evaluating RDE-LDV with PEMS(Portable Emission Measurement Systems). According to the trip requirements of the 2nd RDE package announced by the EC, the objectives of the present study include the development of Korean RDE routes to reflect domestic traffic and road conditions. Based on the results, both RDE routes are in correct compliance with RDE-LDV regulations, including trip requirements and trip dynamics. KOR-NIER Route 1, in particular, has a higher driving load in rural driving with regard to excessive gradient of elevation compared to KOR-NIER Route 2, including relatively plane rural driving.

Elemental Composition of PM2.5 Particulate with a 3-Stage DRUM Sampler during Spring and Summer Seasons in Urban Area of Gwangju, Korea (3-Stage DRUM 샘플러를 이용한 광주 도심지역의 봄철과 여름철 PM2.5 원소적 조성 비교)

  • Ryu S.Y.;Kim Y.J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.699-708
    • /
    • 2005
  • To characterize the elemental composition of fine particles in urban area, $PM_{2.5}$ was collected by a 3-stage DRUM impactor at Gwangju during spring and summer. Time and size resolved concentrations for 19 trace elements were obtained by synchrotron X-Ray fluorescence analysis. Trace elements in summer were distributed in smaller size range compared to those in spring. Almost trace element concentrations in fine particles were highly increased during the Asian dust. In spring, soil elements such as Si, K, Ca, Ti and Fe had low enrichment factors indicating the dominant influence of soil dust. However, all elements had high enrichment factors in summer implying that these elements could be emitted from the anthropogenic sources. Factor analysis was conducted with the elemental composition data in order to identify anthropogenic sources of aerosols in urban area during spring and summer. Fine particles in spring have several sources such as soil dust originating from China continental region, coal and oil combustion, biomass burning, sea salt, ferrous and nonferrous metal sources. On the other hand, fine particles in summer were influenced by road dust, gasoline vehicle as well as coal and oil combustion, sea salt, ferrous and nonferrous metal sources.

Development of Hydrazine Thruster Latching Valve (하이드라진 추력기 래칭 밸브 개발)

  • Yoon Ho-Sung;Chae Heon-Jung;Lee Jae-Hun;Cho Nam-Kyung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.363-367
    • /
    • 2005
  • Latching valves are operated like solenoid valves by open/close command and they maintain final open or close commend without electric power source, so they are widely used in propulsion system of satellite and launch vehicle requiring reliability and being subject of restriction of power. This paper present design and test procedure of latching valve using permanent magnet polarized solenoid, which is developed for 45N Hydrazine propulsion system, to estimate feasibility of design and manufacture of latching valve.

  • PDF

Suggestions on the Selection Method of Priority Monitoring Sites for Hazardous Air Pollutants in Megacities (유해대기오염물질 모니터링을 위한 대도시 우선순위 측정지점 선정기법 제안)

  • Kwon, Hye-Ok;Kim, Seong-Joon;Kim, Yong Pyo;Kim, Sang-Kyun;Hong, Ji-Hyung;Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.544-553
    • /
    • 2017
  • There is an overall guideline of the installation of air quality monitoring stations in Korea, but specified steps for the selection of monitoring sites for hazardous air pollutants(HAPs) are not provided. In this study, we proposed a systematic method for the selection of monitoring sites for HAPs using geographic information system (GIS). As a case study, the Seoul metropolitan area (Seoul, Incheon, and Gyeonggi Province) was chosen, and 15 factors including population, vehicle registration, and emission data were compiled for each grid cell ($7km{\times}7km$). The number of factors above the top 30% of individual data for each grid cell was used to select priority monitoring sites for HAPs. In addition, several background sites were added for data comparison and source identification. Three scenarios were suggested: Scenario 1 with 7 sites, Scenario 2 with 17 sites, and Scenario 3 with 30 sites. This proposal is not the final result for an intensive monitoring program, but it is an example of method development for selecting appropriate sampling sites. These results can be applied not only to HAPs monitoring in megacities but also to the national HAPs monitoring network.

Measurement and Analysis of Transient Voltage for an Inverter-fed Induction Motor (인버터 구동 유도전동기에서 과도전압의 측정과 분석)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Park, Dae-Won;Cho, Young-Jin;Cheon, Sang-Gyu;Choi, Su-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.650-654
    • /
    • 2007
  • Induction motors are widely used as a source of driving force in electric vehicles and pulse width modulation (PWM) inverters are applied to their operation. The issue is that insulation of inverter-fed induction motors (IFMs) are more stressed than in line-powered motors by transient voltages. This paper dealt with experimental results on transient voltage produced by the PWM operation of an induction motor. The peak and the dv/dt of transient voltage depending on the length of power feeding cable and operating frequency were investigated. In the experiment, transient voltages up to 3.3PU of the rated-inverter voltage were recorded for the cable length of 50m. As the cable length is increased, the peak voltage appeared at the motor terminals increases. This phenomenon can be explained by the reflection and the transmission of travelling wave. Consequently, special care for the cable length between the motor and the inverter should be taken in the use of IFM to ensure the full life of insulation system.

Analysis of Nonpoint Sources Runoff Characteristic by Road Types (도로 유형별 비점오염원 유출특성 분석)

  • Yoon, Young-Sam;Kwon, Hun-Gak;Yi, Youn-Jung;Yu, Jay-Jung;Lee, Chun-Sik;Lee, Jae-Kwan
    • Journal of Environmental Science International
    • /
    • v.19 no.11
    • /
    • pp.1375-1384
    • /
    • 2010
  • Growth in population and urbanization has progressively increased the loading of pollutants from nonpoint sources as well as point sources. Especially in case of road regions such as city trunk road, national road and highway are rainfall and pollutants runoff intensive landuses since they are impervious and emit a lot of pollutants from vehicle activity. This research was conducted to investigate the nonpoint sources concentration and quantifying stormwater pollutants which are contained in rainfall runoff water. Three different monitoring sites in Jinju and Changwon city were equipped with an automatic rainfall gauge and flow meter for measuring rainfall and the volume of rainfall runoff. In the case of average EMC value, city trunk road was shown the highest value in target water quality items like as BOD, COD, SS, TN and TP. Or the amount of runoff loads by water quality items showed the highest value in city trunk road. And runoff load in city trunk road was 43.8 times high value compared to highway by value of city trunk road $356.7 mg/m^2$, highway $8.150 mg/m^2$, national road $19.99 mg/m^2$ in the case of BOD.

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.

A Basic Design of Multi Energy Hub Based on Natural Gas Governor Station (가스정압관리소 기반의 복합에너지허브 기본설계)

  • PARK, SOJIN;KIM, HYOUNGTAE;KIM, JINWOOK;KANG, IL-OH;YOO, HYUNSUK;CHOI, KYOUNGSHIK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.405-410
    • /
    • 2020
  • In this literature, we are introduce a basic design of multi energy hub based on natural gas governor station. Multi energy hub consists of turbo expender generator, phosphoric acid fuel cell, pressure swing adsorption, H2 charging station, utilities and etc. We design a hybrid energy hub system that provides energy using these complex energies, and calculates the amount of electricity that can be produced and the amount of hydrogen charged through the process analysis. TEG and phosphoric acid fuel cell produce 2,290 to 2,380 kW and can supply electricity to 500 houses. In addition, By-product H2 gas is refined to H2 vehicle fuel. This will help maximize the balance of energy demand and supply and improve national energy efficiency by integrating unused decompression energy power generation technology and various power generation/heat source technologies.

A Study on the Actual Condition of Playground According to the Characteristics of Outdoor Space in Apartment Housing (아파트 외부 공간 특성에 따른 어린이놀이터 이용실태에 관한 연구)

  • Shin, Eun-Ju
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.9 no.2
    • /
    • pp.5-16
    • /
    • 2009
  • The importance of playground, which is a central place in the outdoor space scheme for apartment and in children's outdoor activity, is increasing. The stature and availability in playground may be varied according to connection between playground and outdoor space and to characteristics of outdoor space. The purpose of this study is to arrange basic data in guidelines of a planning for supporting children's development and for activating its use in the apartment housing. This study conducted the field survey and questionnaire research after selecting 4-case apartment complexes based on the relevant preceding research. The survey results are as follows. Children were recognizing and preferring the playground as the central space in outdoor play activity. Mothers were preferring outdoor space adjacent to playground. There were the most responses with saying that a mother takes to play with a child. Children responded that the use of playground and the rides are the outdoor activity that they do the most. And, it was surveyed that there is difference in dweller's using playground by apartment complex according to characteristics of a planning for outdoor space. Given being connected with square with segregation of pedestrian and vehicle and with the resting space, the availability in playground was the highest. The availability in playground, which has high connection with diversely outdoor space elements while having good accessibility to the apartment building, was surveyed to be high. Playground had high preference in case of being connected with waterfront and resting space, rather than green zone. Diverse environmental artifacts and decorative fence may become a visually stimulus source that can activate the use of playground.

  • PDF

Exhaust Emissions Reduction using Unburned Exhaust Gas Ignition Technology and Hydrocarbon Adsorber (미연 배기가스 점화 기술과 탄화수소 흡착기를 이용한 배기저감)

  • Kim, C.S.;Chun, J.Y.;Choi, J.W.;Kim, D.S.;Lee, Y.S.;Kim, I.T.;Ohm, I.Y.;Cho, Y.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.150-155
    • /
    • 2000
  • Exhaust emissions from vehicles are the main source of air pollution. Many researchers are trying to find the way of reducing vehicle emissions, especially in the cold transient period of the FTP-75 test. In this study, UEGI (Unburned Exhaust Gas Ignition) technology, warming up the close-coupled catalytic converter (CCC) by igniting the unburned exhaust mixture using two glow plugs installed in the upstream of the catalyst, was developed. It was applied to an exhaust system with a hydrocarbon adsorber to ensure an effective reduction of HC emission during the cold start period. Results showed that the CCC reaches the light-off temperature (LOT) in a shorter time compared with the baseline exhaust system, and HC and CO emissions are reduced significantly during the cold start.

  • PDF