• Title/Summary/Keyword: Varying coefficient

Search Result 591, Processing Time 0.033 seconds

pH-sensitive Swelling Behavior of Poly(vinyl alcohol)-hyaluronic Acid Polymer Hydrogel Membranes

  • Ji, Hye Won;Chon, Se Won;Yoon, Tae Il;Hwnag, Ho Sang;Kwon, Ji Young;Shin, Seung Hoon;Chung, Sung Il;Rhim, Ji Won
    • Korean Membrane Journal
    • /
    • v.6 no.1
    • /
    • pp.24-29
    • /
    • 2004
  • Poly(vinyl alcohol)(PVA) and hyaluronic acid(HA) hydrogel membranes were prepared with varying HA contents from 10 to 50 wt% of PVA. The water contents of the resulting PVA-HA hydrogel membranes in various pH conditions were measured. And the permeation coefficient of indomethacin was determined using several PVA-HA hydrogel membranes at various pH conditions and also 37$^{\circ}C$.

Effect of the Nano Ceria Slurry Characteristics on end Point Detection Technology for STI CMP (STI CMP용 가공종점 검출기술에서 나노 세리아 슬러리 특성이 미치는 영향)

  • 김성준;강현구;김민석;백운규;박재근
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.1
    • /
    • pp.15-20
    • /
    • 2004
  • Through shallow trench isolation (STI) chemical mechanical polishing (CMP) tests, we investigated the dependence of pad surface temperature on the abrasive and additive concentrations in ceria slurry under varying pressure using blanket film wafers. The pad surface temperature after CMP increased with the abrasive concentration and decreased with the additive concentration in slurries for the constant down pressure. A possible mechanism is that the additive adsorbed on the film surfaces during polishing decreases the friction coefficient, hence the pad surface temperature gets lower with increasing the additive concentration. This difference in temperature was more remarkable for the higher concentration of abrasives. In addition, in-situ measurement of spindle motor was carried out during oxide and nitride polishing. The averaged motor current for oxide film was higher than that for nitride film, meaning the higher friction coefficient.

  • PDF

NUMERICAL STUDY FOR COOLING CAPACITY IMPROVEMENT OF ENGINE ROOM ENCLOSURE SYSTEM (엔진실 차폐 시스템의 냉각성능 개선을 위한 수치적 연구)

  • Bae, Y.S.;Yoo, G.J.;Choi, H.K.
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.39-45
    • /
    • 2009
  • In engine room, proper enclosure system is preferable for reducing noise level but the enclosure system in the engine room causes bad influence on cooling performance due to poor ventilation. Cooling efficiency of the enclosure system can be improved by varying fan speed and proper flow path for ventilation. In this study, numerical analysis is performed to assess cooling effect of the enclosure system using finite volume method. The RNG k-$\varepsilon$ model is adopted for turbulence model along with heat exchanger model and porous media model for heat exchanger analysis, and moving reference frame model for rotational fan. Verification result shows reasonable agreement with experimental data. Analysis results show direct effect of velocity and temperature distribution on cooling ability in the enclosure system. Enclosure system of case B shows high heat transfer coefficient and has the smallest area ratio of opened flow passages which is good for noise level reduction.

Frost formation on a cold cylinder surface in cross flow (원관의 냉각면에서의 착상)

  • Lee, Dong-Hoon;Yang, Dong-Keun;Lee, Kwan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1540-1545
    • /
    • 2004
  • This paper presents a semi-empirical model to predict the frost growth formed on the cold cylinder surface. The model is composed of the correlations for frost properties including the various frosting parameters and local heat transfer coefficient. The effects of varying the correlations for local heat transfer coefficient on the frost growth are examined to establish the model. The numerical results are compared with experimental data obtained by the previous researchers. The results agree well with the experimental data within a maximum error of 13%. As the results, the frost thickness decreases with changing angular position from front stagnation to separation point. Also the effects of air velocity on the frost growth are negligible, as compared to the other frosting parameters.

  • PDF

나노 세리아 슬러리에 첨가된 연마입자와 첨가제의 농도가 CMP 연마판 온도에 미치는 영향

  • 김성준;강현구;김민석;박재근
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.12a
    • /
    • pp.122-125
    • /
    • 2003
  • We investigated the effect of the abrasive and additive concentrations in Nano ceria slurry on the pad surface temperature under varying pressure through chemical mechanical polishing (CMP) test using blanket wafers. The pad surface temperature after CMP increased with the abrasive concentration and decreased with increase of the additive concentration in slurries for the constant down pressure. A possible mechanism is that the additive adsorbed on the film surface during polishing decreases the friction coefficient, hence the pad surface temperature gets lower with increase of the additive concentration. This difference of temperature was more remarkable for the higher concentration of abrasives. In addition, in-situ measurement of spindle motor was carried out during oxide and nitride polishing. The averaged motor current for oxide film was higher than that for nitride film, which means the higher friction coefficient.

  • PDF

Analysis of Welding Deformation By Equivalent Load Method on Steel Structures (등가하중법을 이용한 강구조물 용접변형 해석)

  • 박정용;이재원;박길현
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.93-98
    • /
    • 2002
  • This study presents a new method to derive the constraint coefficient from the degree of angular deformation caused by welding, as measured experimentally by varying the shape of welded joints and the magnitude of constraints and from analysis results given by the elastic FEM method. The equivalent load was then calculated with this constraint coefficient. The validity of the numerical analysis involved in this new method was confirmed by its agreement with the experimental results. As for the effects of the constraints based on the shape of the welded joints in the case of Butt welding when the constraint coefficients are not considered, the deformed quantity produced by analysis is larger that produced by experiment and consequently is largely affected by the constraints.

  • PDF

Mode-by-mode evaluation of structural systems using a bandpass-HHT filtering approach

  • Lin, Jeng-Wen
    • Structural Engineering and Mechanics
    • /
    • v.36 no.6
    • /
    • pp.697-714
    • /
    • 2010
  • This paper presents an improved version of the Hilbert-Huang transform (HHT) for the modal evaluation of structural systems or signals. In this improved HHT, a well-designed bandpass filter is used as preprocessing to separate and determine each mode of the signal for solving the inherent modemixing problem in HHT (i.e., empirical mode decomposition, EMD, associated with the Hilbert transform). A screening process is then applied to remove undesired intrinsic mode functions (IMFs) derived from the EMD of the signal's mode. A "best" IMF is selected in each screening process that utilizes the orthogonalization coefficient between the signal's mode and its IMFs. Through mode-by-mode signal filtering, parameters such as the modal frequency can be evaluated accurately when compared to the theoretical value. Time history of the identified modal frequency is available. Numerical results prove the efficiency of the proposed approach, showing relative errors 1.40%, 2.06%, and 1.46%, respectively, for the test cases of a benchmark structure in the lab, a simulated time-varying structural system, and of a linear superimposed cosine waves.

Dynamic Analysis on the Closing Resistors of Gas Insulated Switchgear

  • Cho Hae-Yong;Lee Sung-Ho;Lim Sung-Sam
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1607-1613
    • /
    • 2006
  • GIS (Gas Insulated Switchgear) is used in electric power system to insure non conductivity, breaking capacity and operating reliability. In the present study, dynamic analysis on the closing resistors of the GIS has bees carried out by the commercial dynamic analysis code COSMOS MOTION and 3-D modeling program SOLID WORKS. In order to find the minimum value of chatter vibration of closing resistors, the motion of moving and fixed resistor parts of closing resistors were simulated by varying the spring constant, the damping coefficient and the mass of moving and fixed resistor parts. The simulated results were compared with experimental results. The application of the results could reduce chatter vibration of closing resistors of the GIS. These data are also useful on the development of future model GIS with minimum chatter vibration for the determinations of the spring constant, the damping coefficient and mass of a moving part.

Study on Insulation Prediction of Triple Junction in $SF_6$ ($SF_6$ 가스 중의 삼중점 절연파괴 예측기술에 관한 연구)

  • Cho, Yong-Sung;Chong, Jin-Kyo;Lee, Woo-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.989-993
    • /
    • 2009
  • Triple junction which consists of three media(electrode, insulator, and gas) should be considered in designing of high voltage equipments due to the electric field enhancement. In this paper, positive lightning impulse breakdown voltage is predicted based on the streamer theory for simplified insulator models and 72.5kV spacer with varying the triple junction geometry and gas pressure, and the results are compared to the experimental results. The electric field coefficient concept is also applied in order to evaluate the partial discharge inception voltage and the surface flashover voltage from the streamer inception voltage. The application of this method using the constant electric field coefficient of 1.3 and 0.66 is possible for evaluating the triple-junction insulation of the simplified insulator and the 72.5kV spacer respectively. The error rate is under 10%.

Development of Vibrational Analysis Algorithm for Truncated Conical Shells (끝이 잘린 원추형 셸의 진동해석 알고리즘의 개발)

  • Yeo, D.J.
    • Journal of Power System Engineering
    • /
    • v.9 no.3
    • /
    • pp.58-65
    • /
    • 2005
  • This paper deals with the free vibrations of truncated conical shell with uniform thickness by the transfer influence coefficient method. The classical thin shell theory based upon the $Fl\ddot{u}gge$ theory is assumed and the governing equations of a conical shell are written as a coupled set of first order differential equations using the transfer matrix. The Runge-Kutta-Gill integration and bisection method are used to solve the governing differential equations and to compute the eigenvalues respectively. The natural frequencies and corresponding mode shapes are calculated numerically for the truncated conical shell with any combination of boundary conditions at the edges. And all boundary conditions and the intermediate supports between conical shell and foundation could be treated only by adequately varying the values of the spring constants. Numerical results are compared with existing exact and numerical solutions of other methods.

  • PDF