• 제목/요약/키워드: Variation of parameter

검색결과 1,675건 처리시간 0.031초

합성얼음을 이용한 얼음의 두께와 수선면각 변화에 따른 쇄빙상선 저항특성 연구 (Study on Resistance Performance of Icebreaking Cargo Vessel According to Variation of Thickness and Waterline Angle by Using Synthetic Ice)

  • 신병철;김문찬;이승호;이승기
    • 대한조선학회논문집
    • /
    • 제48권2호
    • /
    • pp.134-140
    • /
    • 2011
  • The present paper deals with characteristics of resistance performance according to the variation of synthetic ice thickness and hull form. The resistance test has been conducted with pack ice condition in Pusan National University towing tank. Waterline angle has been chosen as a main parameter for the variation of hull form characteristics, which is the most important factor especially in icebreaking cargo vessel. The serial comparisons of resistance test have been done with the variation of hull form parameter as well as with the different thickness of synthetic ice. The different trend of resistance performances with increasing of waterline angle has been shown at each synthetic ice thickness. The present test results is expected to be confirmed by comparing the test results in ice tank in the near future.

슬라이딩 관측기를 이용한 유도전동기의 센서리스 벡터제어 (Sensorless Vector Control of Induction Motor using Sliding Observer)

  • 박지호;김구형;조용길;김춘삼;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1922-1924
    • /
    • 1998
  • In this paper, the robust vector control method of Induction Motor for the purpose of improving the system performance deterioration caused by parameter variations is proposed. The full order state observer estimates the stator current and the rotor flux by using the state prediction of state variables. And, the motor speed is estimated without speed sensor using the full order state observer. Also, the parameter variation is compensate by the Sliding Observer. By using this method, speed sensorless control and current contol with no affection of the parameter variation can be obtained simultaneously.

  • PDF

Adaptive Sliding Mode Control을 이용한 전기유압식 서어보시스템의 위치제어에 관한 연구 (A Study on the Position Control of Electrohydraulic Servo System Using Adaptive Sliding Mode Control)

  • 현장환;이정오
    • 한국정밀공학회지
    • /
    • 제11권6호
    • /
    • pp.143-157
    • /
    • 1994
  • This paper is concerned with the position control of electrohydraulic servo system under parameter variation. An adaptive sliding mode control which uses the direct parameter estimation scheme, is proposed to design a robust controller for fast and accurate control of the system. It is shown that the adaptive sliding mode control algorithm is robust and effective in attaining fast and accurate position control of system under time-dependent parameter variation. It is also shown experimentally that chattering phenomena in a sliding mode control can significantly be reduced by using boundary layer technique, and that new approach in sliding mode control introducing a term proportional to the distance between the current state and the sliding surface in the control law is effective to obtain fast response and to increase stability of the system. Computer simulation on the dynamic performance of the control system is also presented.

  • PDF

유도전동기 직접벡터제어를 위한 회전자 시정수 추정 (Rotor Time Constant Estimation for Induction Motor Direct Vector Control)

  • 배상준;최종우;김흥근;이홍희;전태원
    • 전력전자학회논문지
    • /
    • 제9권5호
    • /
    • pp.413-419
    • /
    • 2004
  • 고피나스 모델 자속관측기를 사용한 유도전동기 직접벡터제어 시스템에서 회전자 시정수에 오차가 있을 경우 시스템의 동특성이 저하되는 현상을 살펴보았으며, 이를 해결하기 위한 방안으로 MRAC를 이용한 회전자 시정수 실시간 추정 알고리즘을 제안하였다. 제안한 방식의 타당성을 검증하기 위해서 자속관측기에 사용되는 전동기 상수들의 오차가 회전자 시정수 추정에 미치는 영향을 실험적으로 분석한 결과 전동기 상수에 다소 오차가 있더라도 회전자 시정수의 추정오차는 5% 이내로 수렴됨을 보였다. 따라서 본 연구에서 제안한 회전자 시정수 추정 알고리즘을 고피나스 모델 자속관측기에 적용하게 되면 전동기 상수 변동에 강인한 유도전동기 직접벡터제어 시스템을 구현할 수 있다.

State--Feedback Guaranteed-Cost Controllers for Systems with Controller Gain Variation

  • Park, Sung-Wook;Oh, Jun-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.75.3-75
    • /
    • 2001
  • This paper addresses the design of State-feedback Robust Guaranteed-Cost Controllers with controller gain variations. Since the unstructured uncertainty is the most dominant uncertainty in the modeling of the plant, the plant is assumed to have the unstructured uncertainty. It is necessary to take the controller parameter perturbation into consideration when we design the robust controller. Otherwise, the resulting controller may show the fragility property. That is to say, the extremely small controller parameter variation may result in the instability of the overall closed-loop system. Therefore, the design purpose is that the maximum performance index is guaranteed in the presence of the unstructured plant uncertainty and controller parameter variations ...

  • PDF

위치모수를 이용한 로버스트 CV 관리도의 설계 (Design of the Robust CV Control Chart using Location Parameter)

  • 전동진;정영배
    • 산업경영시스템학회지
    • /
    • 제39권1호
    • /
    • pp.116-122
    • /
    • 2016
  • Recently, the production cycle in manufacturing process has been getting shorter and different types of product have been produced in the same process line. In this case, the control chart using coefficient of variation would be applicable to the process. The theory that random variables are located in the three times distance of the deviation from mean value is applicable to the control chart that monitor the process in the manufacturing line, when the data of process are changed by the type of normal distribution. It is possible to apply to the control chart of coefficient of variation too. ${\bar{x}}$, s estimates that taken in the coefficient of variation have just used all of the data, but the upper control limit, center line and lower control limit have been settled by the effect of abnormal values, so this control chart could be in trouble of detection ability of the assignable value. The purpose of this study was to present the robust control chart than coefficient of variation control chart in the normal process. To perform this research, the location parameter, ${\bar{x_{\alpha}}}$, $s_{\alpha}$ were used. The robust control chart was named Tim-CV control chart. The result of simulation were summarized as follows; First, P values, the probability to get away from control limit, in Trim-CV control chart were larger than CV control chart in the normal process. Second, ARL values, average run length, in Trim-CV control chart were smaller than CV control chart in the normal process. Particularly, the difference of performance of two control charts was so sure when the change of the process was getting to bigger. Therefore, the Trim-CV control chart proposed in this paper would be more efficient tool than CV control chart in small quantity batch production.

분산 전원의 고립 운전 검출 기법의 개발 (Development of a New Islanding Detection Method for Distributed Resources)

  • 장성일;김광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권11호
    • /
    • pp.506-513
    • /
    • 2001
  • The islanding detection for distributed resources (DR) becomes an important and emerging issue in power system protection since the distributed generator installations are rapidly increasing and most of the installed systems are interconnected with distribution network. In order to avoid the negative impacts from islanding operations of DR on protection, operation and management of distribution system, it is necessary to effectively detect the islanding operations of DR and rapidly disconnect it from distribution network. Generally, it is difficult to detect islanding operation by monitoring only one system parameter This paper presents a new logic based islanding detection method for distributed resources(DR) which are interconnected with distribution network. The proposed method detects the islanding operation by monitoring four system parameter: voltage variation, phase displacement, frequency variation, and the variation of total harmonic distortion(THD) of current; therefore, it effectively detects island operation of DR unit operating in parallel with the distribution network. We also verified the efficiency of the proposed algorithm using the radial distribution network of IEEE 34 bus model.

  • PDF

연산시간지연 및 민감성을 고려한 UPS 인버터용 2차 데드비트 제어기 (2nd Order Deadbeat Controller Considering Calculation Time Delay and Sensitivity for UPS Inverter)

  • 김병진;최재호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권4호
    • /
    • pp.170-178
    • /
    • 2001
  • Deadbeat technique has been proposed as a digital controller for an UPS inverter to achieve the fast, response to a load variation and to conserve a very low THD under a nonlinear load condition. This scheme contains a fatal drawback, sensitivity against parameter variation and calculation time delay. This paper proposes a second order deadbeat controller, which fundamentally solves the calculation time delay problem and certainly guarantees the robustness of the parameter's variation. RLP(Repetitive Load Predictor) which predicts the load current ahead of two sampling time and FVR(Fundamental Voltage Regulator) which eliminates the fundamental errors of the output voltage are also proposed for the second order deadbeat controller to apply to UPS inverter systems. These are shown theoretically and practically through simulation and experiment.

  • PDF

가변구조제어기를 이용한 BLDC 모터의 전류제어 (Variable Structure Current Controller for BLDC Motor)

  • 박영배;김대준;전향식;최영규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.452-455
    • /
    • 1997
  • It is well known that Variable Structure Controller(VSC) is robust to parameters variation and disturbance but its performance depends on the design parameters such as switching gain and slope of sliding surface. This paper proposes a more robust VSC that is composed of local VSC's. Each local VSC considers the local system dynamics which has narrow parameter variation and disturbance. We optimize the local VSC's by use of Evolution Strategy, and then we use Artificial Neural Network to generalize the local VSC's and construct the overall VSC in order to cover the whole range of parameter variation and disturbance. Simulation on BLDC motor current control has verified the proposed VSC is superior to the conventional VSC.

  • PDF

연산시간지연을 고려한 UPS 인버터용 2차 데드비트 전류 제어기의 강인 제어 (Robust control of End order deadbeat current controller considering calculation time delay for UPS inverter)

  • 김병진;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1056-1058
    • /
    • 2000
  • Deadbeat technique has been proposed as a digital controller for an UPS inverter to achieve the fast response to a load variation and to conserve a very low THD under a nonlinear load condition. This scheme contains a fatal drawback, sensitivity against parameter variation and calculation time delay. This paper proposes a second order deadbeat current controller, which fundamentally solves the calculation time delay problem and certainly guarantees the robustness of the parameter's variation. This is shown theoretically and practically through simulation and experiment.

  • PDF