• Title/Summary/Keyword: Variation of Thickness

Search Result 1,690, Processing Time 0.03 seconds

Development of Phantom and Comparison Analysis for Performance Characteristics of MOSFET Dosimeter (MOSFET 선량계 특성분석을 위한 팬톰 개발 및 특성 비교)

  • Chung, Jin-Beom;Lee, Jeong-Woo;Kim, Yon-Lae;Lee, Doo-Hyun;Choi, Kyoung-Sik;Kim, Jae-Sung;Kim, In-Ah;Hong, Se-Mie;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.48-54
    • /
    • 2007
  • This study is to develope a phantom for MOSFET (Metal Oxide Semiconductors Field Effect Transistors) dosimetry and compare the dosimetric properties of standard MOSFET and microMOSFET with the phantom. In this study, the developed phantom have two shape: one is the shape of semi-sphere with 10cm diameters and the other one is the flat slab of $30{\times}30cm$with 1 cm thickness. The slab phantom was used for calibration and characterization measurements of reproducibility, linearity and dose rate dependency. The semi-sphere phantom was used for angular and directional dependence on the types of MOSFETs. The measurements were conducted under $10{\times}10cm^2$ fields at 100cm SSD with 6MV photon of Clinac (21EX, Varian, USA). For calibration and reproducibility, five standard MOSFETS and microMOSFETs were repeatedly Irradiated by 200cGy five times. The average calibration factor was a range of $1.09{\pm}0.01{\sim}1.12{\pm}0.02mV/cGy$ for standard MOSFETS and $2.81{\pm}0.03{\sim}2.85{\pm}0.04 mV/cGy$ for microMOSFETs. The response of reproducibility in the two types of MOSFETS was found to be maximum 2% variation. Dose linearity was evaluated In the range of 5 to 600 cGy and showed good linear response with $R^2$ value of 0.997 and 0.999. The dose rate dependence of standard MOSFET and microMOSFET was within 1% for 200 cGy from 100 to 500MU/min. For linearity, reproducibility and calibration factor, two types of MOSFETS showed similar results. On the other hand, the standard MOSFET and microMOSFET were found to be remarkable difference in angular and directional dependence. The measured angular dependence of standard MOSFET and microMOSFET was also found to be the variation of 13%, 10% and standard deviation of ${\pm}4.4%,\;{\pm}2.1%$. The directional dependence was found to be the variation of 5%, 2% and standard deviation of ${\pm}2.1%,\;{\pm}1.5%$. Therefore, dose verification of radiation therapy used multidirectional X-ray beam treatments allows for better the use of microMOSFET which has a reduced angular and directional dependence than that of standard MOSFET.

  • PDF

Theoretical Analysis of FBARs Filters with Bragg Reflector Layers and Membrane Layer (브래그 반사층 구조와 멤브레인 구조의 체적 탄성파 공진기 필터의 이론적 분석)

  • Jo, Mun-Gi;Yun, Yeong-Seop
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.4
    • /
    • pp.41-54
    • /
    • 2002
  • In this study, we have analyzed the effects of the membrane layer and the bragg reflector layers on the resonance characteristics through comparing the characteristics of the membrane type FBAR (Film Bulk Acoustic Wave Resonator) and the one type bragg reflector layers with those of the ideal FBAR with top and bottom electrode contacting air by using equivalent circuit technique. It is assumed that ZnO is used for piezoelectric film, $SiO_2$ are used for membrane layer and low acoustic impedance layer, W are used for the high acoustic reflector layer and Al is used for the electrode. Each layer is considered to have a acoustic propagation loss. ABCD parameters are picked out and input impedance is calculated by converting 1-port equivalent circuit to simplified equivalent circuit that ABCD parameters are picked out possible. From the variation of resonance frequency due to the change of thickness of electrode layers, reflector layers and membrane layer it is confirmed that membrane layer and the reflector layer just under the electrode have the greatest effect on the variation of resonance frequency. From the variation of resonance properties, K and electrical Q with the number of layers, K is not much affected by the number of layers but electrical Q increases with the number of layers when the number of layers is less than seven. The electrical Q is saturated when the number of layers is large than six. The electrical Q is dependent of mechanical Q of reflector layers and membrane layer. Both ladder filter and SCF (Stacked Crystal Filters) show higher insertion loss and out-of-band rejection with the increase of the number of resonators. The insertion loss decreases with the increase of the number of reflector layers but the bandwidth is not much affected by the number of reflector layers. Ladder Filter and SCF with membrane layer show the spurious response due to spurious resonance properties. Ladder filter shows better skirt-selectivity characteristics in bandwidth but SCF shows better characteristics in insertion loss.

Anatomic Study of Pterygomaxillary Junctions in Koreans

  • Kim, Dong-Yul;Cho, Yeong-Cheol;Sung, Iel-Yong;Yun, Dae-Kawn;Kim, Min-Uk;Kim, Ji-Uk;Son, Hyung-Suck;Son, Jang-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.6
    • /
    • pp.368-375
    • /
    • 2013
  • Purpose: This study is to evaluate the location of descending palatine artery, the anatomy of pterygomaxillary junction, and the association between the obtained anatomic values and several variables. Methods: We studied 40 patients who were treated for dentofacial deformites from January 2010 to December 2012 in Ulsan University Hospital, Ulsan, Korea. Cone beam computed tomogram (CBCT) was done for all patients. The reference point was approximately 5 to 7 mm above anterior nasal spine on axial image. We evaluated the location of the greater palatine canal (line a: on the coronal view, the shortest line between the center of greater palatine canal and pterygoid fossa; distance a: the distance of line a). We also measured the thickness (line b: on the coronal view, the shortest line between maxillary posterior sinus wall and pterygoid fossa; distance b: distance of line b), width (line c: on the coronal view, the line perpendicular to the line b and the nearest line from the most concave point of lateral pterygoid plate to the medial pterygoid plate; distance c: distance of line c) and height (line d: on sagittal view, the vertically longest line of pterygoid junction; distance d: the distance of line d) in pterygomaxillary junctions. We evaluated the association between the obtained anatomic values and several variables (sex, age, height and weight). Results: The mean distance a was 4.78 mm, mean distance b was 5.53 mm, mean distance c was 8.01 mm and mean distance d was 13.22 mm. The differences between age and mean distance c and weight and mean distance d in pterygomaxillary junctions are statistically significant. Conclusion: There apparently is anatomic variation of pterygomaxillary junctions by various values, particularly weight and age in a Korean clinical population.

Theoretical analysis of erosion degradation and safety assessment of submarine shield tunnel segment based on ion erosion

  • Xiaohan Zhou;Yangyang Yang;Zhongping Yang;Sijin Liu;Hao Wang;Weifeng Zhou
    • Geomechanics and Engineering
    • /
    • v.37 no.6
    • /
    • pp.599-614
    • /
    • 2024
  • To evaluate the safety status of deteriorated segments in a submarine shield tunnel during its service life, a seepage model was established based on a cross-sea shield tunnel project. This model was used to study the migration patterns of erosive ions within the shield segments. Based on these laws, the degree of deterioration of the segments was determined. Using the derived analytical solution, the internal forces within the segments were calculated. Lastly, by applying the formula for calculating safety factors, the variation trends in the safety factors of segments with different degrees of deterioration were obtained. The findings demonstrate that corrosive seawater presents the evolution characteristics of continuous seepage from the outside to the inside of the tunnel. The nearby seepage field shows locally concentrated characteristics when there is leakage at the joint, which causes the seepage field's depth and scope to significantly increase. The chlorine ion content decreases gradually with the increase of the distance from the outer surface of the tunnel. The penetration of erosion ions in the segment is facilitated by the presence of water pressure. The ion content of the entire ring segment lining structure is related in the following order: vault < haunch < springing. The difference in the segment's rate of increase in chlorine ion content decreases as service time increases. Based on the analytical solution calculation, the segment's safety factor drops more when the joint leaks than when its intact, and the change rate between the two states exhibits a general downward trend. The safety factor shows a similar change rule at different water depths and continuously decreases at the same segment position as the water depth increases. The three phases of "sudden drop-rise-stability" are represented by a "spoon-shaped" change rule on the safety factor's change curve. The issue of the poor applicability of indicators in earlier studies is resolved by the analytical solution, which only requires determining the loss degree of the segment lining's effective bearing thickness to calculate the safety factor of any cross-section of the shield tunnel. The analytical solution's computation results, however, have some safety margins and are cautious. The process of establishing the evaluation model indicates that the secondary lining made of molded concrete can also have its safety status assessed using the analytical solution. It is very important for the safe operation of the tunnel and the safety of people's property and has a wide range of applications.

Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array (선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Kim, H.J.;Suh, J.J.;Kim, S.H.;Lee, C.H.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

A Study on the Dose Changes Depending on the Shielding Block Type of Irradiation During Electron Beam Theraphy (전자선치료 시 조사부위 차폐물 형태에 따른 선량변화 연구)

  • Lee, Sun-Yeb;Park, Cheol-Soo;Lee, Jae-Seung;Goo, Eun-Hoe;Cho, Jae-Hwan;Kim, Eng-Chan;Moon, Soo-Ho;Kim, Jin-Soo;Park, Cheol-Woo;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.253-260
    • /
    • 2010
  • The primary focus of this study was to explore the variation in dose distributions of electron beams between different types of construction structure of cut-out blocks embodied in electron cones, given that the structure is considered one of the causes of multiple scattered radiation from electrons which may affect dose distributions. For evaluation, two types of cut-out blocks, divergency and straight, manufactured for this study, were compared in terms of area of interval in distribution of dose, and flatness and symmetric state of surface being radiated. The results showed that divergency cut-out blocks reduced the lateral scattering effects on the thickness of cut-out blocks more substantially than straight ones, leading to more uniform dose distribution at baseline depth. Notably in divergency cut-out blocks, the high dose area decreased more significantly, and more uniform dose distribution was observed at the edge of the irradiated field. This points to a need to consider the characteristics of dose distribution of electron beams when setting up radiotherapy planing at the venues. Therefore, this study is significant as an exploratory work for ensuring high accuracy in dose delivery for patients.

Requirement of Non-phytate Phosphorus in Synthetic Broiler Breeder Diet

  • Bhanja, S.K.;Reddy, V.R.;Panda, A.K.;Rama Rao, S.V.;Sharma, R.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.6
    • /
    • pp.933-938
    • /
    • 2007
  • An experiment was conducted to study the laying performance, shell quality, bone mineralization, hatchability of eggs and performance of progeny (weight at day one and 14 d of age, P content in day old chick, leg score and survivability of chicks) of synthetic broiler breeders fed different levels of non-phytate phosphorus (NPP). Six levels of NPP (1.2, 1.8, 2.4, 3.0, 3.6 and 4.2 g/kg diet) at a constant calcium (Ca) level (30 g/kg) in a maize-soya-deoiled rice bran based diet were tested. Levels of dicalcium phosphate, shell grit and deoiled rice bran were adjusted to achieve the desired levels of NPP and Ca. Each level of NPP was fed with a weighed quantity of feed (160 g/b/d) to 40 female broiler breeders from 25 to 40 weeks of age housed in individual cages. Each bird was considered as a replicate. Egg production, feed/egg mass, body weight, egg weight, shell weight, shell thickness, egg specific gravity, serum Ca content and tibia breaking strength were not influenced (p>0.05) by the variation in dietary NPP levels tested. Increasing the dietary levels of NPP did not influence the hatchability of eggs, phosphorus (P) contents both in egg yolk and day old chick, chick body weight at day one and 14 d of age, leg score and survivability of chicks up to 14 d of age. Maximum response ($p{\leq}0.01$) in shell breaking strength, tibia ash and serum inorganic P contents were observed at NPP levels of 2.09, 2.25 and 3.50 g per kg diet, respectively. The retention of Ca increased, while the P retention decreased ($p{\leq}0.01$) with increasing dietary levels of NPP. Though maximum responses in shell breaking strength, bone ash and serum inorganic P were observed at NPP higher than 1.2 g/kg diet, the broiler breeder performance in terms of egg production, shell quality, hatchability of eggs and progeny performance and their survivability was not influenced by dietary NPP concentrations. It is concluded that synthetic broiler breeders maintained in cages do not require more than 1.2 g NPP/kg diet with a daily intake of 192 mg NPP/b/d during 24 to 40 weeks of age.

Effect of End-taping Treatments on Prevention of Drying Defects during Radio-Frequency/Vacuum Drying of Domestic Yellow Poplar Log Cross Section (엔드테이핑 처리들이 백합나무 원반의 고주파진공건조 중 건조결함 예방에 미치는 영향)

  • LEE, Nam-Ho;ZHAO, Xue-Feng;Chang, Sae-Hwan;SHIN, Ik-Hyun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.59-68
    • /
    • 2008
  • This study was carried out to investigate the effects of the Inside end-taping (Inside-ET) and Outside end-taping (Outside-ET) treatments on prevention of drying defects during radiofrequency/vacuum (RF/V) drying domestic yellow poplar log cross section with size of 20~75 mm in thickness and 120~470 mm in diameter. The treatments of Inside-ET and Outside-ET were quite effective for producing sound log cross sections with thinner than 33 mm and smaller than 270 mm in diameter. Even the 60 mm- and 75 mm-thick log cross sections, if the diameter was smaller than 30 cm, it might expect preventing formation of border checks by appropriate end-taping treatments. The positions of the observed border checks differed in diameter ranging at a relative radius about 0.50~0.63 diameter, and it was estimated that it was necessary to select the border position of end-taping treatment properly according to the diameter of log cross sections. It was observed that the radius of 0.3 diameter was the critical location for pretreatment for preventing formation of border checks in the log cross section with middle diameter. There were severe border checks and V-shaped cracks in the log cross section with large diameter. This was because of the severe variation of moisture content along radial direction of natural characteristic of domestic yellow poplar.

Evaluation of high nutrient diets on litter performance of heat-stressed lactating sows

  • Choi, Yohan;Hosseindoust, Abdolreza;Shim, YoungHo;Kim, Minju;Kumar, Alip;Oh, Seungmin;Kim, YoungHwa;Chae, Byung-Jo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.11
    • /
    • pp.1598-1604
    • /
    • 2017
  • Objective: The present study investigated the litter performance of multiparous sows fed 3% and 6% densified diets at farrowing to weaning during summer with mean maximum room temperature of $30.5^{\circ}C$. Methods: A total of 60 crossbred multiparous sows were allotted to one of three treatments based on body weight according to a completely randomized design. Three different nutrient levels based on NRC were applied as standard diet (ST; metabolizable energy, 3,300 kcal/kg), high nutrient level 1 (HE1; ST+3% higher energy and 16.59% protein) and high nutrient level 2 (HE2; ST+6% higher energy and 17.04% protein). Results: There was no variation in the body weight change. However, backfat thickness change tended to reduce in HE1 in comparison to ST treatment. Dietary treatments had no effects on feed intake, daily energy intake and weaning-to-estrus interval in lactating sows. Litter size, litter weight at weaning and average daily gain of piglets were significantly greater in sows in HE1 compared with ST, however, no difference was observed between HE2 and ST. Increasing the nutrient levels had no effects on the blood urea nitrogen, glucose, triglyceride, and creatinine at post-farrowing and weaning time. The concentration of follicle stimulating hormone, cortisol and insulin were not affected by dietary treatments either in post-farrowing or weaning time. The concentration of blood luteinizing hormone of sows in ST treatment was numerically less than sows in HE2 treatment at weaning. Milk and colostrum compositions such as protein, fat and lactose were not affected by the treatments. Conclusion: An energy level of 3,400 kcal/kg (14.23 MJ/kg) with 166 g/kg crude protein is suggested as the optimal level of dietary nutrients for heat stressed lactating sows with significant beneficial effects on litter size.

Effect of Immersion in Water and Thermal Cycling on the Mechanical Properties of Light-cured Composite Resins (광중합형 수복용 복합레진의 기계적 성질에 미치는 수중침적과 Thermal Cycling의 영향)

  • Bae, Tae-Sung;Kim, Tae-Jo;Kim, Hyo-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.327-336
    • /
    • 1996
  • This study was performed to investigate the effec% of immersion in water and thermal cycling on the mechanical peoperties of light cured restorative composite resins. Five commerically available light-cured composite resins(Photo Clearfil A : CA, Lite-Fil A . LF, Clearril Photo Posterior CP, Prisms AP.H.. PA, 2100 : ZH) were unto The specimens of 12 m in diameter and 0.7 m in thickness were made, and an immersion in $37^{\circ}C$ water for 7 days and a thermal cycling of 1000 cycles at 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$ baths were performed. Biaxial flexure test was conducted using the ball-on-three-ball method at the crosshead speed of 0.5mm/min. In order to investigate the deterioration of composite resins during the thermal cycling test, Weibull analysis for the biaxial flexure strengths was done. Fracture surfaces and the surfaces before and after the thermal cycling test were examined by SEM. The highest Weibull modulus value of 10.09 after thermal cycling tests which means the lowest strength variation, was observed in the CP group, and the lowest value of 4.47 was obsered in the LF Group. Biaxial flexure strengths and Knoop hardness numbers significantly decreased due to the thermal cycling ($\textit{p}$< 0.01), however, they recovered when specimens were drie4 The highest biaxial flexure strength of 125.65MPa was observed in the ZH group after the thermal cycling test, and the lowest value of 64.86MPa was observed in the CA group. Biaxial flexure strengths of ZH and CP groups were higher than those of PA, CF, and CA groups after thermal cycling test($\textit{p}$< 0.05). Knoop hardness numbers of CP group after the thermal cycling test was the highest(95.47 $\pm$ 7.35kg/$mm^2$) among the samples, while that of CA group was the lowest(30.73 $\pm$ 2.58kg/$mm^2$). Knoop hardness numbers showed the significant differences between the CP group and others after the thermal cycling test(($\textit{p}$< 0.05). Fracture surfaces showed that the composite resin failure developed along the matrix resin and the filler/resin interface region, and the cracks propagated in the conical shape from the maximum tensile stress zone.

  • PDF