• Title/Summary/Keyword: Variation of Discharge Ratio

Search Result 92, Processing Time 0.026 seconds

System Performance Variation for Relative Location of Pre-swirl Nozzles and Receiver Holes in Radial On-Board Injection Type Pre-swirl System (반경방향 분사방식 프리스월 시스템의 프리스월 노즐과 리시버 홀의 상대적 위치에 따른 시스템 성능변화)

  • Lee, Jonggeon;Lee, Hyungyu;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.1
    • /
    • pp.43-53
    • /
    • 2020
  • The effect of the relative location between pre-swirl nozzle and receiver hole on the performance of radial on-board injection type pre-swirl system was analyzed. In this study, tendency of the change of discharge coefficient and temperature drop efficiency were analyzed for 20 design points through the combination of 5 pre-swirl nozzle location and 4 receiver hole location. Discharge coefficient of system tended to be similar to the pressure ratio of the pre-swirl nozzle. System performance variation occurred as the flow structure in the cavity was affected by the surface, and the influence of the stationary surface is greater than that of the rotating surface. Discharge coefficient of system changed -1.39% to 1.25% and temperature drop efficiency changed -5.41% to 2.94% refer to reference design point.

Validity of Fecal Pollution Source Tracking using FC/FS Ratio (FC/FS 비율에 의한 분변오염원의 출처파악의 유효성)

  • Park, Ji-Eun;Lee, Young-Ok
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • This study was conducted to assess the validity of fecal coliforms to fecal streptococci ratio (FC/FS) for distinguishing the human from animal origin of fecal pollution in surface water. FC/FS ratio determined in effluent from municipal wastewater and human feces treatment plant (WWTP) and in downstream close to discharge of human feces was above 4 which indicates human origin. However FC/FS ratios determined seasonally in other water zones of the Nakdong River, even in the same sampling site, varied differently (above 4 or less than 0.7) due to different survival time of FC and FS and other environmental factors such as rainfall in watershed. Compared to other season, FC/FS ratios in winter were much lower regardless of the origin. It is concluded that the FC/FS ratio determined in surface water is not always valid for determining the origin of fecal pollution.

Residual Stress Prediction in Multi-layer Butt Weld Using Crack Compliance Method (컴플라이언스법에 의한 다층 맞대기 이음의 잔류응력 추정)

  • Kim, Yooil;Lee, Jang Hyun
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.74-79
    • /
    • 2012
  • It depends on the joint configuration, dimensions and constraints of the joint whether the residual stress at the root of single-sided butt weld is tensile or not. Therefore, recommendation is generally made that high R ratio should be used in the fatigue test of welded joint in order to prevent excessively long life caused by compressive residual stress. In this research, the residual stress profile in butt weld joint was obtained through compliance method, using successive extension of a slot and measurement of the variation of strain during the slot extension. The residual stress profile was firstly assumed to be the linear summation of Legendre polynomials up to 9th order excluding 0th and 1st order. Strain variation on the surface was measured while the slot was being extended by cutting to find out the 8 unknown coefficients of each polynomial term. The cut was made by the electric discharge machine. It was concluded that the residual stress near the surface is positive valued, however, it turned into the negative value as soon as it passed through 2 or 3 mm of the depth.

Historical changing of flow characteristics over Asian river basins

  • Ha, Doan Thi Thu;Kim, Tae-Son;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.118-118
    • /
    • 2020
  • This study investigates the change of flow characteristics over 10 Asian river basins in the past 30 years (1976-2005). The variation is estimated from The Soil and Water Assessment Tool (SWAT) model outputs based on reanalysis data which was bias-corrected for Asian monsoon reagion. The model was firstly calibrated and validated using observed data for daily streamflow. Four statistical criteria were applied to evaluate the model performance, including Coefficient of determination (R2), Nash - Sutcliffe model efficiency coeffi cient (NSE), Root mean square error-observations standard deviation ratio (RSR), and Percentage Bias (PBIAS). Then parameters of the model were applied for the historical period 1976-2005. The estimates show a temporal non-considerable increasing rate of daily streamflow in most of the basins over the past 30 years. The difference of monthly discharge becomes more significant during the months in the wet season (June to September) in all basins. The seasonal runoff shows significant difference in Summer and Autumn, when the rainfall intensity is higher. The line showing averaged runoff/rainfall ratio in all basins is sharp, presenting high variation of seasonal runoff/rainfall ratio from season to season.

  • PDF

New Electrode Designs for High Luminous Efficiency in AC PDP

  • Moon, Cheol-Hee;Moon, Jae-Seung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.740-743
    • /
    • 2009
  • In this paper we proposed a new electrode design to get an enhanced luminous efficiency in AC PDP. The width and shape of the TTO electrode were varied, and the electro-optical properties such as luminance, power consumption, luminous efficiency were estimated with the variation of frequency, duty ratio and applied voltage. The discharge characteristics were investigated to explain the effect of the new electrode structure on the electro-optical properties.

  • PDF

Study on the Atmospheric Plasma Characteristics of Dielectric Barrier Discharge due to a Variation of the Duty Ratio of Pulse Modulation (펄스변조의 듀티비 변경에 따른 DBD 대기압 플라즈마 특성 연구)

  • Park, Jong-in;Hwang, Sang-hyuk;Jo, Tae Hoon;Yun, Myoung Soo;Kwak, Hyoung sin;Jin, Gi nam;Jeon, Buil;Choi, Eun Ha;Kwon, Gi-Chung
    • Korean Journal of Materials Research
    • /
    • v.25 no.11
    • /
    • pp.616-621
    • /
    • 2015
  • Atmospheric pressure plasma is used in the biological and medical fields. Miniaturization and safety are important in the application of apply atmospheric plasma to bio devices. In this study, we made a small, pocket-sized inverter for the discharge of atmospheric plasma. We used pulse power to control the neutral gas temperature at which the, when plasma was discharged. We used direct current of 5 V of bias(voltage). The output voltage is about 1 to 2 kilo volts the frequency is about 80 kilo hertz. We analyzsed the characteristics of the atmospheric plasma using OES(Optical emission spectroscopy) and the Current-Voltage characteristic of pulse power. By calculating of the current voltage characteristics, we were able to determine that, when the duty ratio increased, the power that actually effects the plasma discharge also increased. To apply atmospheric plasma to human organisms, the temperature is the most important factor, we were able to control the temperature by modulating the pulse power duty ratio. This means we can use atmospheric plasma on the human body or in other areas of the medical field.

Emission Characteristics of Flat Fluorescent Lamp for LCD Backlight Using Inert Gas Mixture

  • Heo, Sung-Taek;Lee, Yang-Kyu;Kang, Jong-Hyun;Yoon, Seung-Il;Oh, Myung-Hoon;Lee, Dong-Gu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1522-1525
    • /
    • 2007
  • In this study, flat fluorescent lamps (FFLs) having surface discharge structures was fabricated by screen printing technique and were studied using spectraradiometer and square pulse power supply. Two types of FFLs having different shapes of electrodes (crosstype and line-type structure) were compared with variation of discharge shape and mixed gas ratio.

  • PDF

Discharge Characteristics of Low Xe and High Xe Content in He-Ne-Xe Gas Mixture in PDP

  • Kwon, Oh-Yung;Bae, Hyun-Sook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.366-368
    • /
    • 2008
  • The discharge characteristics of He-Ne-Xe gas mixture with the variation of Xe content are investigated through the numerical simulation. VUV efficacy in the gas condition of low Xe content increases due to more excitation and the case of high Xe content shows the improvement of VUV efficacy with the increase of He content but decreased VUV efficacy after tthe He mixing ratio of He and Ne is 0.5 due to frequent ionization.

  • PDF

Two-Dimensional Simulation of Hg Flat Fluorescent Lamps for an LCD Backlight unit (액정디스플레이 후판광원용 평판형 수은 형광램프의 2차원 시뮬레이션 연구)

  • Yoon, Hyun-Jin;Lee, Hae-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1275-1281
    • /
    • 2007
  • The discharge phenomena in a flat fluorescent lamp for the backlight unit of liquid crystal displays are simulated by sung a two-dimensional fluid model. The numerical methods for the calculation of plasma dynamics and the radiation transport are introduced for the discharge simulation and for the transmission of the vacuum ultraviolet lights. The simulation results are presented to compare the luminance and the luminance efficacy with the variation of gas pressure, gas mixture ratio, driving voltage, and frequency.

Discharge Waveform Properties on Electrical Sterilization by HV Impulse (고전압 펄스에 의한 전기 살균에서 방전 파형의 특성 분석)

  • Lee, H.K.;Suehiro, J.;Hara, M.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.944-946
    • /
    • 1998
  • We evaluated cell survivability by changing RLC value on HV impulse network. When the L value is changed from 0 to 10mH in this circuit. we found that cell survivability is shown large decline with 4mH of L value. I respect to this result, when waveshapes of oscillatory decay are presented along the variation of L value in RLC circuit, we analyzed whether discharge waveform properties have an effect on sterilization ratio, and measured threshold voltage as the minimum peak voltage of a single pulse which can sterilize cells. Finally, we found that the sterilization effect was related to number of threshold voltage waveforms being applied.

  • PDF