• Title/Summary/Keyword: Variable wavelength

Search Result 107, Processing Time 0.025 seconds

Localized Surface Plasmon Resonance (LSPR) Biosensors on Metal Nanoparticles with the Design of Bioreceptors

  • Kim, Min-Gon;Park, Jin-Ho;Byun, Ju-Young;Shin, Yong-Beom
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.126-126
    • /
    • 2014
  • Label-free biomolecular assay based localized surface plasmon resonance (LSPR) of noble metal nanoparticles enables simple and rapid detection with the use of simple equipment. Nanosized metal nanoparticles exhibit a strong absorption band when the incident light frequency is resonant with the collective oscillation of the electrons, which is known as the LSPR. Here we demonstrate localized surface plasmon resonance (LSPR) substrates such as plasmonic Au nanodisks fabricated by a nanoimprinting process and gold nanorod-immobilized surfaces and their applications to highly sensitive and/or label-free biosensing. To increase detection sensitivity various bioreceptors weree designed. A single chain variable fragment (scFv) was used as a receptor to bind C-reactive protein (CRP). The results of this effort showed that CRP in human serum could be quantitatively detected lower than 1 ng/ml. Aptamers, which were immobilized on gold nanorods, were used to detect mycotoxins. The specific binding of ochratoxin A (OTA) to the aptamer was monitored by the longitudinal wavelength shift of LSPR peak in the UV-Vis spectra resulting from the changes of local refractive index near the GNR surface induced by accumulation of OTA and G-quadruplex structure formation of the aptamer. According to our results, OTA could be quantitatively detected lower than 1 nM level. Additionally, aptamer-functionalized GNR substrate was quite robust and can be regenerated many times by rinsing at 70 OC to remove bound target. During seven times of washing steps, the developed OTA sensing system could be reusable. Moreover, the proposed biosensor exhibited selectivity over other mycotoxins with an excellent recovery for detection in grinded corn samples, suggesting that the proposed LSPR based aptasensor plays an important role in label-free detection of mycotoxins.

  • PDF

Simulation Study of Front-Lit Versus Back-Lit Si Solar Cells

  • Choe, Kwang Su
    • Korean Journal of Materials Research
    • /
    • v.28 no.1
    • /
    • pp.38-42
    • /
    • 2018
  • Continuous efforts are being made to improve the efficiency of Si solar cells, which is the prevailing technology at this time. As opposed to the standard front-lit solar cell design, the back-lit design suffers no shading loss because all the metal electrodes are placed on one side close to the pn junction, which is referred to as the front side, and the incoming light enters the denuded back side. In this study, a systematic comparison between the two designs was conducted by means of computer simulation. Medici, a two-dimensional semiconductor device simulation tool, was utilized for this purpose. The $0.6{\mu}m$ wavelength, the peak value for the AM-1.5 illumination, was chosen for the incident photons, and the minority-carrier recombination lifetime (${\tau}$), a key indicator of the Si substrate quality, was the main variable in the simulation on a p-type $150{\mu}m$ thick Si substrate. Qualitatively, minority-carrier recombination affected the short circuit current (Isc) but not the opencircuit voltage (Voc). The latter was most affected by series resistance associated with the electrode locations. Quantitatively, when ${\tau}{\leq}500{\mu}s$, the simulation yielded the solar cell power outputs of $20.7mW{\cdot}cm^{-2}$ and $18.6mW{\cdot}cm^{-2}$, respectively, for the front-lit and back-lit cells, a reasonable 10 % difference. However, when ${\tau}$ < $500{\mu}s$, the difference was 20 % or more, making the back-lit design less than competitive. We concluded that the back-lit design, despite its inherent benefits, is not suitable for a broad range of Si solar cells but may only be applicable in the high-end cells where float-zone (FZ) or magnetic Czochralski (MCZ) Si crystals of the highest quality are used as the substrate.

Net Analyte Signal-based Quantitative Determination of Fusel Oil in Korean Alcoholic Beverage Using FT-NIR Spectroscopy

  • Lohumi, Santosh;Kandpal, Lalit Mohan;Seo, Young Wook;Cho, Byoung Kwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.208-220
    • /
    • 2016
  • Purpose: Fusel oil is a potent volatile aroma compound found in many alcoholic beverages. At low concentrations, it makes an essential contribution to the flavor and aroma of fermented alcoholic beverages, while at high concentrations, it induced an off-flavor and is thought to cause undesirable side effects. In this work, we introduce Fourier transform near-infrared (FT-NIR) spectroscopy as a rapid and nondestructive technique for the quantitative determination of fusel oil in the Korean alcoholic beverage "soju". Methods: FT-NIR transmittance spectra in the 1000-2500 nm region were collected for 120 soju samples with fusel oil concentrations ranging from 0 to 1400 ppm. The calibration and validation data sets were designed using data from 75 and 45 samples, respectively. The net analyte signal (NAS) was used as a preprocessing method before the application of the partial least-square regression (PLSR) and principal component regression (PCR) methods for predicting fusel oil concentration. A novel variable selection method was adopted to determine the most informative spectral variables to minimize the effect of nonmodeled interferences. Finally, the efficiency of the developed technique was evaluated with two different validation sets. Results: The results revealed that the NAS-PLSR model with selected variables ($R^2_{\upsilon}=0.95$, RMSEV = 100ppm) did not outperform the NAS-PCR model (($R^2_{\upsilon}=0.97$, RMSEV = 7 8.9ppm). In addition, the NAS-PCR shows a better recovery for validation set 2 and a lower relative error for validation set 3 than the NAS-PLSR model. Conclusion: The experimental results indicate that the proposed technique could be an alternative to conventional methods for the quantitative determination of fusel oil in alcoholic beverages and has the potential for use in in-line process control.

Analysis of Polarization and Beam Tilt Characteristics of Single Arm Spiral Antenna by Varying Length and Feed (한팔 나선 안테나의 길이 및 급전 변화에 따른 편파 및 빔 틸트 특성에 대한 분석)

  • Yang, Chan-Woo;Park, Se-Hyun;Jung, Chang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3137-3143
    • /
    • 2009
  • In this paper, a single arm spiral antenna has been investigated about the characteristics of polarization and tilt beam. If a circumference length of spiral is bigger than a wavelength, it have a characteristic of varying maximum radiation beam direction. In addition, circular polarizations (RHCP, LHCP) can be variable by the feeding points (inner, outer). Also maximum beam directions tilt in different direction according to the circular polarizations, LHCP and RHCP. These characteristics of single arm spiral antenna are able to apply in the beam forming, diversity, MIMO application which has dual polarization using an antenna element.

A Study on the Simultaneous Analysis of Fat-Soluble Vitamins in Food Stuffs and Vitamin Products by High Performance Liquid Chromatography (고성능 액체 크로마토그래피에 의한 식품 및 비타민 제제중의 지용성 비타민의 동시 분석에 관한 연구)

  • Poongzag Kim;Chong-Hyeak Kim
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.46-54
    • /
    • 1989
  • The extraction method and quantitative analysis for the fat-soluble vitamins present in food stuffs and vitamin products have been investigated. The simultaneous separation and analysis of the vitamins by reverse phase high performance liquid chromatographic method was conducted using an isocratic elution with methanol : water (95 : 5) eluent on a Novapak $C_{18}$ column. The detection of vitamins was achieved by a variable wavelength UV detector. To improve the detection sensitivity detection wavelengths were set at the highest absorption bands such as 330, 265, 285, and 290nm for the respective vitamins. The analysis for the fat-soluble vitamins was finished within 40 minutes. Alkaline hydrolysis and enzymatic hydrolysis were investigated for the sample preparation; and liquid-liquid extraction and liquid-solid extraction were attempted for the extraction of vitamins. Both hydrolysis methods were turned out to be appropriate for the analysis for vitamins A, D, and E, while for the analysis of vitamin K the enzymatic hydrolysis method demonstrated better results. Diethyl ether, pentane, and n-hexane were found to give higher recovery for the liquid-liquid extraction and silica cartridge for the liquid-solid extraction.

  • PDF

Structural and Optical Properties of CuS Thin Films Grown by RF Magnetron Sputtering (RF 마그네트론 스퍼터링법으로 성장시킨 CuS 박막의 구조적 및 광학적 특성)

  • Shin, Donghyeok;Lee, SangWoon;Son, Chang Sik;Son, Young Guk;Hwang, Donghyun
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.1
    • /
    • pp.9-14
    • /
    • 2020
  • CuS (copper sulfide) thin films having the same thickness of 100nm were deposited on the glass substrates using by radio frequency (RF) magnetron sputtering method. RF powers were applied as a process variable for the growth of CuS thin films. The structural and optical properties of CuS thin films deposited under different power conditions (40-100W) were studied. XRD analysis revealed that all CuS thin films had hexagonal crystal structure with the preferential growth of (110) planes. As the sputtering power increased, the relative intensity of the peak with respect to the (110) planes decreased. The peaks of the two bands (264cm-1 and 474cm-1) indicated in the Raman spectrum exactly matched the typical spectral values of the covellite (CuS). The size and shape of the grains constituting the surface of the CuS thin films deposited under the power condition ranging from 40W to 80W hardly changed. However, the spacing between crystal grains tended to increase in proportion to the increase in sputtering power. The maximum transmittance of CuS thin films grown at 40W to 80W ranged from 50 % to 51 % based on 580nm wavelength, and showed a relatively small decrease of 48% at 100W. The band gap energy of the CuS thin films decreased from 2.62eV (at 40W) to 2.56eV (at 100W) as the sputtering power increased.

A Fundamental Study on Detection of Weeds in Paddy Field using Spectrophotometric Analysis (분광특성 분석에 의한 논 잡초 검출의 기초연구)

  • 서규현;서상룡;성제훈
    • Journal of Biosystems Engineering
    • /
    • v.27 no.2
    • /
    • pp.133-142
    • /
    • 2002
  • This is a fundamental study to develop a sensor to detect weeds in paddy field using machine vision adopted spectralphotometric technique in order to use the sensor to spread herbicide selectively. A set of spectral reflectance data was collected from dry and wet soil and leaves of rice and 6 kinds of weed to select desirable wavelengths to classify soil, rice and weeds. Stepwise variable selection method of discriminant analysis was applied to the data set and wavelengths of 680 and 802 m were selected to distinguish plants (including rice and weeds) from dry and wet soil, respectively. And wavelengths of 580 and 680 nm were selected to classify rice and weeds by the same method. Validity of the wavelengths to distinguish the plants from soil was tested by cross-validation test with built discriminant function to prove that all of soil and plants were classified correctly without any failure. Validity of the wavelengths for classification of rice and weeds was tested by the same method and the test resulted that 98% of rice and 83% of weeds were classified correctly. Feasibility of CCD color camera to detect weeds in paddy field was tested with the spectral reflectance data by the same statistical method as above. Central wavelengths of RGB frame of color camera were tried as tile effective wavelengths to distingush plants from soil and weeds from plants. The trial resulted that 100% and 94% of plants in dry soil and wet soil, respectively, were classified correctly by the central wavelength or R frame only, and 95% of rice and 85% of weeds were classified correctly by the central wavelengths of RGB frames. As a result, it was concluded that CCD color camera has good potential to be used to detect weeds in paddy field.

The Detailed Design of the NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Park, Sung-Joon;Moon, Bongkon;Lee, Dae-Hee;Park, Won-Kee;Lee, Duk-Hang;Ko, Kyeongyeon;Pyo, Jeonghyun;Kim, Il-Joong;Park, Youngsik;Nam, Ukwon;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.39.3-40
    • /
    • 2015
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) onboard NEXTSat-1 is the near-infrared instrument optimized to the first small satellite of NEXTSat series. The capability of both imaging and low spectral resolution spectroscopy in the near-infrared range is a unique function of the NISS. The major scientific mission is to study the cosmic star formation history in local and distant universe. For those purposes, the main targets are nearby galaxies, galaxy clusters, star-forming regions and low background regions. The off-axis optical design of the NISS with two linear variable filters is optimized to have a wide field of view ($2deg.{\times}2deg.$) as well as the wide wavelength range from 0.95 to $3.8{\mu}m$. The mechanical structure is considered to endure the launching condition as well as the space environment. The dewar inside the telescope is designed to operate the infrared detector at 80K stage. From the thermal analysis, we confirmed that the telescope and the dewar can be cooled down to around 200K and 80K, respectively in order to reduce the large amount of thermal noise. The stray light analysis is shown that a light outside a field of view can be reduced below 1%. After the fabrications of the parts of engineering qualification model (EQM), the NSS EQM was successfully assembled and integrated into the satellite. To verify operations of the satellite in space, the space environment tests such as the vibration, shock and thermal-vacuum test were performed. Here, we report the results of the critical design review for the NISS.

  • PDF

ATTITUDE AND EXPOSURE CORRECTIONS OF FIMS DATA (원자외선분광기 FIMS 자료의 자세정보 및 노출시간 보정)

  • Seon, K.I.;Yuk, I.S.;Ryu, K.S.;Lee, D.H.;Park, J.H.;Jin, H.;Shinn, J.H.;Nam, U.W.;Han, W.;Min, K.;Korpela Eric;Nishikida Kaori;Edelstein Jerry
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.399-416
    • /
    • 2004
  • The FIMS (Far-ultraviolet IMaging Spectrograph), the main payload onboard the first Korean science satellite STSAT-1, has performed various observations since its launch on September 2003. It has been found that the attitude informations provided by spacecraft bus system have a time offset problem, and the problem has been extensively studied. After the time offset correction, boresight offsets between FIMS fields of view, of long and short wavelength bands, respectivley, and spacecraft attitude systems, which are mainly due to alignment error between the FIMS and spacecraft mechanical systems, were calculated through the observations of well known calibration targets. Monthly status and precision of the attitude information are also described. Correction methods for spatially variable exposure, intrinsic to FIMS data, are discussed. These results are essential to the FIMS data analysis, and will be used as references for subsequent studies on more accurate attitude corrections.

The Flight Model of the NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Park, Sung-Joon;Moon, Bongkon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Won-Kee;Kim, Il-Joong;Park, Youngsik;Lee, Duk-Hang;Ko, Kyeongyeon;Kim, Mingyu;Nam, Ukwon;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.64.3-65
    • /
    • 2016
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) is the near-infrared instrument optimized to the Next Generation of small satellite series (NEXTSat). The capability of both imaging and low spectral resolution spectroscopy in the near-infrared range is a unique function of the NISS. The major scientific mission is to study the cosmic star formation history in local and distant universe. For those purposes, the main observational targets are nearby galaxies, galaxy clusters, star-forming regions and low background regions. The off-axis optical design is optimized to have a wide field of view ($2deg.{\times}2deg.$) as well as the wide wavelength range from 0.95 to $3.8{\mu}m$. Two linear variable filters are used to realize the imaging spectroscopy with the spectral resolution of ~20. The mechanical structure is considered to endure the launching condition as well as the space environment. The compact dewar is confirmed to operate the infrared detector as well as filters at 80K stage. The electronics is tested to obtain and process the signal from infrared sensor and to communicate with the satellite. After the test and calibration of the engineering qualification model (EQM), the flight model of the NSS is assembled and integrated into the satellite. To verify operations of the satellite in space, the space environment tests such as the vibration, shock and thermal-vacuum test were performed. Here, we report the test results of the flight model of the NISS.

  • PDF