Longitudinal reaction on conductors due to tornado wind load

  • Dingyu Yao;Ashraf El Damatty
    • Wind and Structures
    • /
    • 제38권4호
    • /
    • pp.325-339
    • /
    • 2024
  • The longitudinal force resulting from tornado loads on transmission line is considered a crucial factor contributing to the failure of transmission line structures during tornado events. Accurate estimation of this longitudinal force poses a challenge for structural designers. Therefore, the objective of this paper is to provide a set of charts that can be easily used to estimate the peak longitudinal forces transferred from the conductors to a tower. The critical wind field and corresponding configuration considered in this paper are previously studied and determined. The charts should account for all the conductor parameters that can affect the value of the longitudinal force. In order to achieve that, a parametric study is first conducted to assess the variation of the longitudinal forces with different conductor parameters, based on the critical tornado configuration. Results of this parametric study are used to develop the charts that can be used to calculate longitudinal forces by adopting a multi-variable line regression. The forces calculated from charts are validated by finite element analysis. An example for the usage of the charts is provided at the end of this paper.

소형화된 5.3 GHz 대역 360° 아날로그 위상천이기 설계 (Design of a Miniaturized 5.3 GHz 360° Analog Phase Shifter)

  • 정해창;손범익;이동현;압둘 라흐만;염경환
    • 한국전자파학회논문지
    • /
    • 제24권6호
    • /
    • pp.602-612
    • /
    • 2013
  • 본 논문에서는 주파수 5.3 GHz에서 소형화된 branch line 커플러와 $360^{\circ}$ 이상의 위상천이를 보일 수 있는 가변 리액턴스 부하를 결합하여 소형화된 위상천이기의 설계를 보였다. 위상천이기의 소형화를 위하여, branch line 커플러의 새로운 구조를 제안하였다. 새로운 branch line 커플러는 전송선의 T 및 ${\pi}$형 등가회로 변환 방법을 이용하여 소형화하였다. 소형화된 branch line 커플러는 일반적인 구조에 비해 50 % 이상 소형의 크기를 가진다. 넓은 위상천이량을 갖기 위하여 전송선에 버렉터 다이오드 두 개를 입력과 출력에 연결한 부하 구조를 채택하였다. 특히, 조정 전압에 대한 위상천이량이 완만하도록 임피던스 변환기 역할을 하는 전송선을 설계된 부하 구조에 추가하여 구조를 보완하였다. 추가된 임피던스 변환기에 사용된 전송선 및 선정된 부하 구조의 전송선은 소형화에 장애가 되기 때문에 이를 집중 소자로 등가하여 소형화하였다. 제작된 위상천이기는 $15{\times}15mm^2$의 소형의 크기를 가지며, 조정 전압 0~10 V 범위의 경우, 중심 주파수 5.3 GHz에서 삽입 손실은 약 -4~-6 dB, 반사 손실은 -20 dB 이하, 약 $480^{\circ}$의 넓은 위상천이를 보였다.

이중 특성 임피던스 선로를 이용한 Gysel 3:1 가변 전력분배기 (Gysel 3:1 variable power divider using the dual characteristic impedance transmission line)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제25권10호
    • /
    • pp.1409-1415
    • /
    • 2021
  • Rat-race 구조의 변형인 Gysel 전력분배기는 분배기내 저항을 쉽게 설정할 수 있는 장점을 가지고 있다. Gysel 전력분배기 내에서 선로 임피던스를 다르게 설정하면 두 개의 출력단자에서의 출력 전력 비율을 다양하게 분배할 수 있다. 본 논문에서는 Gysel 전력분배기에서 선로 임피던스를 변화하여 두 개의 출력 단자의 출력 비율을 1:3 또는 3:1로 선택할 수 있는 회로를 제안하였다. 선로의 임피던스 변화는 마이크로스트립 선로 형태의 전송선로 밑면에 비접지 동판을 위치시켜 구현할 수 있다. 비접지 동판과 접지면이 단락 연결하면 전송 선로는 마이크로스트립 선로로 동작하고, 비접지 동판과 접지면을 연결하지 않으면 전송 선로는 코플라나 선로로 동작하게 된다. 제안된 Gysel 가변전력분배기는 중심주파수 1.5GHz에서 제작하였다. 제작된 Gysel 가변 전력분배기는 1.3~1.7 GHz에서 입력 반사계수(S11) -17dB 이하, 두개의 출력 단자의 전력차는 4.8±0.2dB, 높은 출력 전력을 가지는 단자로의 신호 전달계수(S21)는 -1.39±0.12dB, 낮은 출력 전력을 가지는 단자로의 신호 전달계수(S31)는 -6.15±0.08dB의 안정된 값을 가졌다.

Compact Metamaterial-Based Tunable Phase Shifter at 2.4 GHz

  • Jung, Youn-Kwon;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • 제13권2호
    • /
    • pp.137-139
    • /
    • 2013
  • A compact metamaterial (MTM)-based tunable phase shifter consisting of four unit cells with a simple DC bias circuit has been designed at 2.4 GHz. The variable series capacitors and shunt inductors that are required to be loaded periodically onto a host transmission line are realized employing only chip variable capacitors (varactors). In addition, the proposed phase shifter requires only one DC bias source to control the varactors, with the matching condition of the MTM line automatically satisfied. The measured phase shifting range is $285.2^{\circ}$ (from $-74.2^{\circ}$ to $211^{\circ}$). The measured insertion loss is approximately 1.5 dB. The circuit/electromagnetic-simulated and measured results are in good agreement.

비동차 미분방정식을 이용한 외부 전자파에 의한 전송선로 결합해석 (The Coupling Analysis of Electromagnetic Wave to Transmission Line using Nonhomogeneous Differential Equations)

  • 이기철;명성호
    • 한국전자파학회지:전자파기술
    • /
    • 제1권1호
    • /
    • pp.20-27
    • /
    • 1990
  • 본연구의 목적은특성엄피던스가서로다른션로가상호접속되어 있을때,외부전자파에 의해 전송선 로에 유기되는 전류를 해석하기 위한 효과적인 방법을 제안하는 데 었다. 이것은 전송선로 해석을 위해 비동차 미분방정식을 상태변수법으로 풀이하는 과정에서 얻어지는 천이행렬의 특성을 이용한 것으로 전송선로모델의 1차측과2차측을상호 변환시킬 수 있는새로운 전환기법이다. 이 방법을 이용하여 완전 도체명연 위의 전송선로모텔에 대한 유기전력의 특성을 시율레이션 결과를 통해 평가하였다.

  • PDF

송전선로의 고장점 표정 알고리즘 (An Algorithm of fault Location Technique for Long Transmission Line)

  • 박철원;김삼룡;신명철;남시복;이복구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.145-147
    • /
    • 2002
  • In this paper, the improved fault locating method using distributed parameter which calculating the reduced voltage and current according to the ground capacitance in long transmission line was proposed. For the purpose of the fault locating algorithm non influenced source impedance, the loop method was used in the system modeling analysis. To enhance the fault locating, zero sequence of the fault current which is variable according to ground capacitance was not used but positive and negative sequence. System model was simulated using EMTP software. To verify the accuracy of proposed method, in different cases 64 sampled data per cycle was used and 160km and 300km long transmission line has fault resistance $0{\Omega}\;and\;100{\Omega}$ respectively was compared.

  • PDF

UPFC연계시 거리계전기 동작특성에 따른 보호 관리 시스템 (Protective Management System followed Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller)

  • 서정남;정창호;조종만;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.296-298
    • /
    • 2001
  • This paper represents protective management system for transmission line involving the UPFC(Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover, depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. Therefore, established protective system should be taken into account the variable injected voltage of the UPFC and constructed data base system.

  • PDF

송전선로에 UPFC연계시 거리계전기 동작특성에 관한 연구 (A Study on Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller)

  • 서정남;정창호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.220-222
    • /
    • 2001
  • This paper represents impedance calculation of the distance relay using PSCAD/EMTDC software for transmission line involving the UPFC (Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. The presence of the UPFC in the fault loop affects both voltage and current seen by relay. Therefore, the distance relay should be taken into account the variable injected voltage of the UPFC.

  • PDF

선형소자로 종단된 손실이 있는 다중 전송선의 FDTD 해석 (FDTD Analysis of Lossy Multiconductor Transmission Lines Terminated in Linear Loads)

  • 박범준;주재철;이형영;박동철
    • 한국전자파학회논문지
    • /
    • 제11권3호
    • /
    • pp.419-428
    • /
    • 2000
  • 전송선 방정식을 이용하여 선형소자로 종단된 손실이 있는 다중 전송선에서의 누화(crosstalk)와 외부 전자파 에 의한 결합현상을 FDTD 기법으로 해석하였다. 표피효과에 의한 도체의 손실을 고려하여 해석할 경우 전송선 방정식에 컨벌루션 적분이 나타나게 되는데 컨벌루션 적분의 계산량을 줄이기 위해서 프로니(Prony) 방법을 이 용하였다. 또한 저항뿐만 아니라 인덕터나 커패시터로 종단된 다중 전송션을 해석하기 위해 상태변수 표현식 (state-variable formulation)을 이용하였다, TEM(Transverse Electromagnetic) 셀을 이용해서 다중 전송선에서의 누화와 외부 입사장에 의한 전자파 결합현상을 시간영역에서 측정하였고 이론적으로 구한 시율레이션 결과 와 비교하여 잘 일치함을 확인하였다. 또한 PCB와 같이 KSC 3340 TIV보다 상대적으로 손실이 큰 전송선 구조 인 경우 도체의 길이가 짧아도 손실을 포함해야 정확한 예측이 가능함을 확인하였고 저주파에서의 저항은 정상 시간 응답을 결정하고 고주파에서의 임피던스는 초기시간 응답을 결정함을 보였다.

  • PDF

가변 특성 임피던스 전송 선로를 이용한 가변 이중 대역 대역 통과 여파기 (A Tuable Dual-Band Bandpass Filter Design Using Variable Characteristic Transmission Lines)

  • ;정용채;임종식;김동수;김준철
    • 한국전자파학회논문지
    • /
    • 제22권9호
    • /
    • pp.852-857
    • /
    • 2011
  • 본 논문에서는 이중 대역 대역 통과 여파기 설계에 이용 가능한 가변 특성 임피던스 전송 선로의 응용을 제시하였다. 제안된 여파기는 고정된 첫 번째 통과 대역과 가변 가능한 두 번째 통과 대역을 갖는다. 스터브 부하공진기(Stub Loaded Resonator: SLR)는 직렬 공진기와 개방 단락 스터브로 구성되는데, 개방 단락 스터브를 결함 접지 구조(Defected Ground Structure: DGS) 전송 선로와 바랙터 다이오드로 구현함으로써 두 번째 통과 대역의 조정이 가능하다. 제안된 구조의 타당성을 보이기 위해 3개의 전송 영점을 갖는 2단 이중 대역 대역 통과 여파기를 설계하였고, 이론적인 예측값과 시뮬레이션 결과를 실험적으로 증명하였다.