• Title/Summary/Keyword: Variable current

Search Result 1,675, Processing Time 0.023 seconds

The Effect of Direct and Variable Current on Current Efficiency of Copper Anode (조동의 전류효율에 미치는 직류 및 가변전류의 영향)

  • Ahan, Sung-Chen;Lee, Sang-Mun;Kim, Yong-Hwan;Chung, Won-Sub
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.5
    • /
    • pp.223-228
    • /
    • 2006
  • The current efficiency of copper anode containing impurities in copper sulfate solution for electrorefining was studied at various current type such as direct current, variable current and periodic reverse current. The passivity behavior was investigated by galvanostatic technique. The results obtained were that current efficiency of variable current was higher than those of direct current and periodic reverse current. The increased current efficiency could be explained by the formation of slime structure with lower average resistance due to variable current. The frequency of various factors in variable current condition has a greatest effect on current efficiency. It appeared that frequency increased current efficiency when increased from 1 to 4, but further increases did not have an effect.

Parameters Estimation Characteristics of Five-Phase Squirrel-Cage Induction Motor within Over Current Load (과전류 부하에서 5상 농형 유도전동기의 정수 특성)

  • Kim, Min-Huei
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.38-46
    • /
    • 2015
  • This paper propose a variable parameter estimations for variable over current load of five-phase squirrel-cage induction motor(IM) to servo control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, torque command of current components, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental within variable over current load at rated input frequency. There are results of stator winding measurement, no-load test, locked-rotor test, variable over current load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.

A Study on the Reduction of Current Unbalancing of Two-phase Interleaved Buck Converter using Variable Inductor (가변 인덕터를 적용한 2상 인터리브드 벅 컨버터의 전류 불평형 저감에 관한 연구)

  • Lim, Jaeseong;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.417-424
    • /
    • 2022
  • This study proposes a current-balancing technique for an interleaved buck converter using a variable inductor and a snubber capacitor. The proposed scheme balances the inductor current by using the variable inductor and enables zero voltage switching under all load ranges. With the variable inductor, the ripple of inductor current changes according to load variation. In addition, a 1.6 kW prototype is built to verify the validity of the proposed scheme, and the experimental results are successfully obtained.

Variable Step Size Maximum Power Point Tracker Using a Single Variable for Stand-alone Battery Storage PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.218-227
    • /
    • 2011
  • The subject of variable step size maximum power point tracking (MPPT) algorithms has been addressed in the literature. However, most of the addressed algorithms tune the variable step size according to two variables: the photovoltaic (PV) array voltage ($V_{PV}$) and the PV array current ($I_{PV}$). Therefore, both the PV array current and voltage have to be measured. Recently, maximum power point trackers that arc based on a single variable ($I_{PV}$ or $V_{PV}$) have received a great deal of attention due to their simplicity and ease of implementation, when compared to other tracking techniques. In this paper, two methods have been proposed to design a variable step size MPPT algorithm using only a single current sensor for stand-alone battery storage PV systems. These methods utilize only the relationship between the PV array measured current and the converter duty cycle (D) to automatically adapt the step change in the duty cycle to reach the maximum power point (MPP) of the PV array. Detailed analyses and flowcharts of the proposed methods are included. Moreover, a comparison has been made between the proposed methods to investigate their performance in the transient and steady states. Finally, experimental results with field programmable gate arrays (FPGAs) are presented to verify the performance of the proposed methods.

On-line Fault Detection and Diagnosis for Heat Exchanger of Variable Speed Refrigeration System Based on Current Information (전류정보를 이용한 가변속냉동시스템의 열교환기 실시간 고장 진단)

  • Lee, Dong-Gyu;Jeong, Seok-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.88-94
    • /
    • 2007
  • This study deals with on-line fault detection and diagnosis for heat exchanger of variable speed refrigeration system. Conventional studies about fault of heat exchanger in refrigeration system have used temperature and pressure information. The temperature and pressure are able to be used valuably for faults detection of constant speed refrigeration system. However in case of variable speed refrigeration system, the temperature and pressure are no longer useful information for fault detection due to compensation effect of feedback controller. While current information is possible to detect faults of variable speed refrigeration system. The current information was detected in an inverter, it was used after transforming rms value. The faults of variable speed refrigeration system are divided into electrical faults and mechanical faults. We performed fault detection and diagnosis about heat exchanger among mechanical faults such as condenser fouling and evaporator fan fouling through some experiments.

  • PDF

Fault Diagnosis of Variable Speed Refrigeration System Based on Current Information

  • Lee, Dong-Gyu;Jeong, Seok-Kwon;Hua, Li
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.4
    • /
    • pp.137-144
    • /
    • 2008
  • This study deals with on-line fault detection and diagnosis(FDD) for heat exchangers of a variable speed refrigeration system(VSRS) based on current information. The current residual which is the difference between real detected current from current sensors and estimated current from no fault model was utilized to diagnose faults of the heat exchangers. Comparing to the conventional FDD of constant refrigeration system based on temperature and pressure information, the suggested FDD method shows better robustness to the VSRS which has a feedback control loop. Moreover the suggested method can be expected more precise and faster diagnosis of faults about heat exchangers. Throughout some experiments, the validity of the method was verified.

Suppression of Leakage Current and Distortion in Variable Capacitance Devices and their Application to AC Power Regulators

  • Katsuki, Akihiko;Oki, Takuya
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.66-73
    • /
    • 2016
  • The quantity of alternating current (AC) leakage and the value of distortion factor in capacitor currents are discussed with regard to a new power component called variable capacitance device (VCD). This component has terminals for controlling its capacitance. Nonlinear dielectric characteristics are utilized in this device to vary the capacitance. When VCD operates in an AC circuit, the AC leakage from this device through direct current (DC) control voltage source increases according to the conditions of DC control voltage and so on. To solve this problem, we propose techniques for suppressing AC leakage. Although VCD has strong nonlinear characteristics, the current through the capacitor is not distorted significantly. The relations between AC leakage and the distortion in current waveforms are investigated. An application example for an AC power regulator is also introduced to evaluate the distortion in waveforms.

Research on Variable Constant Current Efficiency Measuring Device for Solar Panel to Reuse (태양광 패널 재사용을 위한 가변 정전류 기반의 효율 측정장치에 관한 연구)

  • Sang-Jin Woo;Dae-Heon Kim;Jae-Jin Lee;Oh-Min Kwon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.1
    • /
    • pp.9-17
    • /
    • 2023
  • This paper relates to the development of a device for measuring the efficiency of a solar panel based on a variable constant current, and proposed a standard for reuse of the solar panel. By applying a variable constant current circuit to a solar panel efficiency measuring device, it was easy to apply a maximum power point tracking (MPPT) algorithm. In addition, a load dispersion method was applied to measure the efficiency of a high-capacity solar panel. and it is possible to solve a problematic thermal runaway during a MOSFET parallel operation by applying the load dispersion method. As a result of the experiment, the solar panel efficiency measuring device was able to accommodate a large solar panel of 350W, which is the maximum measurement goal. In this paper, the validity was confirmed through the 310W solar panel efficiency measurement experiment collected after removal.

The Effects of Permanent Income and Non-Human Capital Asset on the Housing Tenureship (항상소득과 비인적자산이 주택점유에 미치는 영향)

  • Lee, Chae-Sung
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.69-78
    • /
    • 2009
  • The purpose of this study is to identify which is the better indicator to forcast housing tenureship between permanent income and current income, and study the effects of non-human capital asset on housing tenureship. To forcast permanent income, a statistic regression equation is used with current income as the dependent variable. Multi-nomial logistic model is used to forcast the housing tenureship Using current income as the dependent variable delivered a more accurate result than using permanent income. Current income is used as a dependent variable and sex, age, education and occupation are used as independent variables to forcast permanent income. Non-human capital asset is also used as an independent variable. Also, excluding non-human capital asset variable when forcasting bothe permanent income and housing tenureship proved to be more accurate. Because permanent income, the sum of future income and current asset, is a good indicator of current consumption including housing, the result with permanent income should be more accurate than the forcast using current income. This implies an underdevelopment of a housing mortgage system that enables people to consume now on the basis of their future income. The Korea's unique Chonsei housing rental system has also made it difficult to forcast housing tenureship based on people's permanent income and asset. While, the Key-money of Chonsei housing and the housing asset of homeowners with debt are very similar in their amount, the result is completely different. One is a renter and the other is a homeowner.

A Study on Speed Variable Proportional Resonant Current Controller of Single-Phase PMSM (단상 영구자석 동기전동기의 속도 가변형 비례공진 전류제어에 관한 연구)

  • Lee, Won-Seok;Hwang, Seon-Hwan;Park, Jong-Won
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.954-960
    • /
    • 2020
  • This paper proposes a speed variable proportional resonant current control method for a single-phase permanent magnet synchronous motor(PMSM). Due to the electromagnetic characteristics of a single-phase PMSM, negative and zero torques are generated in the part corresponding to the phase difference between the stator current and the back electromotive force. In addition, overcurrent limitation is required because of the low stator resistance and inductance in sensorless operation. When using the vector control for current control of single-phase PMSM under these conditions, processes of coordinate transformation, inverse coordinate transformation, and generation of virtual dq-axis components are required. However, the proposed variable speed proportional resonant current control method does not need the coordinate transformation used for AC motors. In this paper, we have confirmed stable maneuverability by using variable proportional resonant current control algorithm, and proposed sensorless control based on a mathematical model of a single-phase PMSM without a position sensor when reaching a constant speed. The usefulness of the current control method was verified through several experiments.