• Title/Summary/Keyword: Variable Guide Vane

Search Result 20, Processing Time 0.027 seconds

The influence of guide vane opening on the internal flow of a francis turbine

  • Wei, Qingsheng;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.274-281
    • /
    • 2013
  • The variable demand on the energy market requires a great flexibility in operating hydro turbines. However, Francis turbine operated at off-design conditions poses technical challenges related to large unsteady forces given by residual swirl and angular momentum. In order to improve the performance of a Francis turbine, the paper presents a numerical investigation of the 3D flow in the turbine at off-design conditions and discusses the influence of variable guide vane openings on the internal flow of a Francis turbine with the help of computational fluid dynamics. First, the internal flow characteristics of Francis turbine operated by varied guide vane angle at off design condition are computed and the optimal guide vane angle is obtained. Secondly, the Francis turbine is operated with guide vane number varies at the optimal guide vane angle. Finally, pressure contours and velocity distributions in the distributor are discussed and compared.

An Approach for the Integrated Performance Analysis of a Small Turbofan engine with Variable Inlet Guide and Variable Stator Vane (가변 안내익 및 정익을 가지는 소형 터보팬 엔진의 성능예측을 위한 통합 해석법 연구)

  • Kim, Sang-Jo;Kim, Dong-Hyun;Son, Chang-Min;Kim, Kui-Soon;Kim, You-Il;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.23-32
    • /
    • 2012
  • The present study is aimed to develop an integrated performance analysis approach for the application of a compressor with variable inlet guide vane (VIGV) and vairable stator vane (VSV) in a small turbofan engine. For the integrated analysis approach, an engine performance analysis program, NPSS and a computer program used for predicting of axial flow compressor performance based on stage stacking method, STGSTK were linked with an optimisation package, Isight. This enables off-design performance analysis for the turbofan engine with VIGV and VSV hence provides the capability to predict stable operation condition of the engine with acceptable surge margin.

Off-design performance analysis of radial inflow turbines with or without variable area guide vane (가변안내깃이 존재하거나 없는 구심터빈의 탈설계 성능해석)

  • 한기수;김광호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2171-2180
    • /
    • 1991
  • An analysis model for off-design performance of radial inflow turbines with or without variable area guide vane is developed, where two important factors in loss models, total pressure ratio between variable area guide vane exit and scroll casing inlet and rotor loss coefficient are determined without experimental data. The analysis results show that the predicted trends with or without variable area guide vane are consistent with the experimental observations. The comparison of present method with the well-known NASA off-design performance analysis program shows that the mass flow rate and static efficiency by present analysis are in good agreement with those by the NASA program. Therefore, this method can be used to predict off-design performance of radial inflow turbines with validity of the loss models used by present analysis.

Effects of Variable Guide Vane Setting Angle on the Performance of Multi-Stage Axial Compressor (가변안내깃 설치각이 다단 축류압축기 성능에 미치는 영향)

  • Park, JunYoung;Seo, JeongMin;Lim, HyungSoo;Choi, Bumseok;Choi, Taewoo;Choi, Jaeho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.5
    • /
    • pp.9-18
    • /
    • 2016
  • Generally the variable guide vane is used to secure the sufficient operating point in the off-design condition. In this study the inlet guide vane, 1st and 2nd stators in a multi-stage axial compressor are movable to obtain the operating range. So the effects of variable guide vane setting angle on the performance of 2.5 stage axial compressor were investigated at 70 % and 90 % conditions of nominal rotating speed in this paper. The steady-state and unsteady numerical analyses were conducted at each operating condition. The performance map, lost efficiency and flow fields were compared.

NUMERICAL PREDICTION OF THE OPTIMAL STAGGER ANGLES FOR A HIGH-POWER TURBO BLOWER (고마력 터보 블로어의 최적 깃배치각에 관한 수치 예측)

  • Park, T.G.;Chung, H.T.;Park, J.Y.;Sung, B.I.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.75-81
    • /
    • 2011
  • The turbo blowers having large power capacity are generally composed of the variable inlet guide vane, the impeller and the variable diffuser. In the present study, the effect of the stagger angles on the aerodynamic performances has been investigated by CFD methods. The design specifications of the reference model having 400kW power were given as 7.43kg/s of mass flow rate, 1.66 of pressure ratio with 12000rpm of impeller rotating speed. As the first simulation parameter, the diffuser vane angle was varied in the range of ${\pm}$20 degree from the initial-design point. The inlet guide vane angles, as the second one, was changed in the range of ${\pm}$40 degree from the initial-design point. The commercial Navier-Stokes solver, ANSYS-CFX, was applied to solve the three-dimensional unsteady flow fields inside the turbo blower. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.

Surge Control of Turbofan Engine Compressor with the Variable Inlet Guide Vane (가변 안내익을 이용한 터보팬 엔진 압축기의 서지 제어)

  • Bae, Kyoungwook;Kim, Sangjo;Han, Dongin;Min, Chanoh;Lee, Daewoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.7
    • /
    • pp.539-546
    • /
    • 2013
  • Surge phenomenon can be occurred in a compressor when compressor performance of turbofan engine for an aircraft is changed considerably in a short time on the cases like take-off phase and changing of RPM from idle to maximum, because performance of aircraft engine is changed suddenly. This study is aimed to avoid surge in a compressor. Dynamic simulation in a compressor is modeled by simulink in specific condition. Fuel flow is control input, rpm and air mass flow are expressed in terms of transfer function. Surge margin is obtained by using compressor performance map from NPSS. VIGV(Variable Inlet Guide Vane) is controlled by PD controller with difference between surge margin and reference. Finally this paper verifies IGV can prevent surge phenomenon in a compressor.

A Study on the Performance Prediction Method for an Axial Compressor with Variable Inlet Guide Vane (가변 입구 안내익이 있는 축류압축기의 성능예측 방법에 관한 연구)

  • Kim, Dong-Hyun;Kim, Sang-Jo;Kim, Kui-Soon;Son, Chang-Min;Kim, You-Il;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • In this study, numerical method, stage stacking method based on the result of numerical method and scaled stage stacking method have been applied to predict the performance of a multi-stage axial compressor with inlet guide vane. The results obtained through three different methods for off-design conditions were compared with performance test data. And the effect the angle of variable inlet guide vane was also investigated. The three-dimensional numerical simulation has been performed by using flow analysis program, $FLUENT^{TM}$ 6.3 and the performance prediction based on the stage stacking method has been performed with compressor analysis code from NASA.

Active Surge Control with Variable Inlet Guide Vane

  • Choi, Wook-Jin;Kim, Sang-Un;Won, Sang-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1211-1214
    • /
    • 2004
  • In this paper, we propose to use variable inlet guide vane as a means of active surge control to solve above problems. There is some advantage. For example, since the inlet guide vanes are already present in POSCO, no additional actuation device is required. We can collect all data easily which is related to the test and can simulate new model using our compressors. We can obtain the result that blow-off valve is opened less 5% and can operate air compressor automatically and more efficiently. Through a simulation example, the effectiveness of the proposed schemes is illustrated.

  • PDF

A Study on Flow Characteristics and Efficiency in Guide Vane of Diffuser Pump Using PIV Measurement (PIV를 이용한 디퓨저펌프 정익에서의 성능과 유동특성에 관한 연구)

  • 김정환;김범석;김진구;함승덕;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.633-640
    • /
    • 2003
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation Identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

A Study on Flow and Efficiency Characteristics in Guide Vane of Diffuser Pump Using PIV Measurement (PIV 계측을 이용한 디퓨져펌프의 정익에서의 성능과 유동특성에 관한 연구)

  • Kim, J. H.;Choi, M. S.;Kim, J. G.;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.29-35
    • /
    • 2000
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF