• 제목/요약/키워드: Variable Displacement

검색결과 496건 처리시간 0.03초

자기에너지법을 이용한 선형 BLDC전동기의 최적설계 (Optimal Design of Linear BLDC Motor Using Magnetic Energy Method)

  • 흥정표;강도현;주수원;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.895-897
    • /
    • 2001
  • It must be able to calculate thrust to design and manufacture linear BLDC motor by required specification. If magnetic energy with respect to displacement of mover of linear BLDC electric motor be obtained, thrust can be calculated. It can decide optimal design factor of linear BLDC motor through change of thrust by design variable using magnetic energy method. It can predict variation of thrust by pitch of pole and design optimally using coenergy that is attained from FEM.

  • PDF

다이아프램이 없는 콘크리트 충전 원형강관 기둥-H형강 보 접합부의 구조적 거동에 관한 실험적 연구 (Experimental Study on the Structural Behavior of Concrete-Filled Circular Tubular Column to H-Beam connections without Diaphragm)

  • 강현식;문태섭
    • 한국강구조학회 논문집
    • /
    • 제9권1호통권30호
    • /
    • pp.13-22
    • /
    • 1997
  • This paper is concerned with an experimental study on structural behavior of Concrete-Filled Circular Tubular(CFCT) column to H-beam connections. The important parameters are the number of inner reinforced rib and the width of H-beam flange(100, 150, 200mm) with variable column thickness(5.8mm, 9.2mm, 12.5mm) around the joint between CFCT and H-beam. Test results are summarized for the displacement, strength, initial stiffness, failure mode and energy absorption capacity of each specimen. The purpose of this paper is to investigate the initial stiffness and the strength of connections to evaluate the structural behavior of the CFCT column to H-beam connections. From the discussion about the test results, the basic data for non diaphragm connection design would be suggested.

  • PDF

Microstep Stepper Motor Control Based on FPGA Hardware Implementation

  • Chivapreecha, Sorawat;Dejhan, Kobchai
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.93-97
    • /
    • 2005
  • This paper proposes a design of stepper motor control in microstep driven mode using FPGA (Field Programmable Gate Array) for hardware implementation. The methods to drive stepper motor in microstep excitation mode are to control of the controlling currents in each phase windings of stepper motor with reference signals. These reference signals are used for controlling the current levels, the required variation of current levels with rotor position can be obtained from the ideal linear or sinusoidal approximations to the static torque-displacement ($T-{\theta}$) characteristic curve. In addition, the hardware implementation of stepper motor controller can be designed uses VHDL (Very high speed integrated circuits Hardware Description Language) and synthesis using an Altera FPGA, FLEX10K family, EPF10K20RC240-4 device as target technology and use MAX+PlusII program for overall development. A multi-stack variable-reluctance stepper motor of Sanyo Denki is used in the experiments.

  • PDF

Inelastic seismic analysis of RC bridge piers including flexure-shear-axial interaction

  • Lee, Do Hyung;Elnashai, Amr S.
    • Structural Engineering and Mechanics
    • /
    • 제13권3호
    • /
    • pp.241-260
    • /
    • 2002
  • The effect of shear coupled with axial force variation on the inelastic seismic behaviour of reinforced concrete bridge piers is investigated in this paper. For this purpose, a hysteretic axial-shear interaction model was developed and implemented in a nonlinear finite element analysis program. Thus, flexure-shear-axial interaction is simulated under variable amplitude reversed actions. Comparative studies for shear-dominated reinforced concrete columns indicated that a conventional FE model based on flexure-axial interaction only gave wholly inadequate results and was therefore incapable of predicting the behaviour of such members. Analysis of a reinforced concrete bridge damaged during the Northridge (California 1994) earthquake demonstrated the importance of shear modelling. The contribution of shear deformation to total displacement was considerable, leading to increased ductility demand. Moreover, the effect of shear with axial force variation can significantly affect strength, stiffness and energy dissipation capacity of reinforced concrete members. It is concluded that flexure-shear-axial interaction should be taken into account in assessing the behaviour of reinforced concrete bridge columns, especially in the presence of high vertical ground motion.

Optimum design of parabolic and circular arches with varying cross section

  • Uzman, Umit;Daloglu, Ayse;Saka, M. Polat
    • Structural Engineering and Mechanics
    • /
    • 제8권5호
    • /
    • pp.465-476
    • /
    • 1999
  • A structural optimization process is presented for arches with varying cross-section. The optimality criteria method is used to develop a recursive relationship for the design variables considering displacement, stresses and minimum depth constraints. The depth at the crown and at the support are taken as design variables first. Then the approach is extended by taking the depth values of each joint as design variable. The curved beam element of constant cross section is used to model the parabolic and circular arches with varying cross section. A number of design examples are presented to demonstrate the application of the method.

철근콘크리트 구조물의 비탄성해석을 위한 보-기둥 접합부의 해석모델링 기법 (Analytical Modeling Method of Beam-Column Joints for the Inelastic Analysis of R/C Structures)

  • 장극관;황정현;양승호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.287-295
    • /
    • 2001
  • The purpose of this paper to describe an analytical model that is capable of reproducing the hysteretic behavior of beam-column joints under cyclic loading and to suggest the variable of hysteretic model for the inelastic analysis of R/C frame structures to do this quasi-static analysis using IDARC program was performed for the beam-column joints. The effort to obtain the result of analysis similar to those of experiment was made by determining the value for hysteretic parameters representing stiffness degradation, strength deterioration and pinching effect. The accuracy and reliability of the proposed analytical model was demonstrated by comparison of load-displacement relation, maximum strength, stiffness degradation and energy dissipation.

  • PDF

Active Stick 제어기 개발에 관한 연구 (A study of an Active Stick Controlling System with Friction Observer)

  • 김명열;남윤수
    • 산업기술연구
    • /
    • 제24권B호
    • /
    • pp.207-214
    • /
    • 2004
  • An active stick which supplies force feedback to the operator is developed in this study. A mathematical model of the active stick is derived, and compared with the experimental result. It turns out that the frictional torque due to the mechanical contacts of several parts of the stick is one of the major barriers to achieve high precision operation of the stick. The frictional effect of the stick is cancelled out by using a friction observer. The efficacy of the friction observer is verified through the numerical simulation. Because of the observer dynamics, there are some limitations in exact recovering the static friction and Stribeck effect. However, the friction observer follows the real friction on the average. It's anticipated that the application of the friction observer to the closed loop control of the active stick improves the performance of the displacement versus force characteristics, which will be proved experimentally in the further study.

  • PDF

변위 및 응력제약을 받는 철골구조물의 최적설계 (Optimal Design of Steel Frameworks with Displacement and Stress Constraints)

  • 정영식;정진현
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.288-295
    • /
    • 1996
  • This work presents an optimality criteria method applicable io the design of plane frames with I-shape sections. All kinds of constraints are treated properly to ensure the mathematical rigour of the method as ever. Among the various properties of a section, the cross-sectional area is chosen as the design variable associated with the member. Then other properties, moment of inertia and depth, are determined from the cross-sectional area using relationships established in advance from the sectional data for AISC standard W shapes. The optimality criteria established in this work is perfect in mathematical terms provided that the relationships between properties of a section are correct. A redesign algorithm is derived relying heavily on the Newton-Raphson method to solve the system of nonlinear constraint equations. A worked example is also Presented.

  • PDF

모형시험을 통한 Smart 양방향말뚝 재하시험에 관한 연구 (Study of Smart Bi-directional Pile Load Test by Model Test)

  • 김낙경;김웅진;주용선;김성규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1088-1093
    • /
    • 2010
  • The Smart bi-directional pile load test with variable end plate overcomes the shortcoming of the Osterberg cell test. It is possible that the ultimate bearing capacity of piles can be known by using two different end plates. The first step is to measure end bearing capacity with smaller end plate and the second step is similar to the conventional O-cell test. In this study, model test was performed to evaluate the smart bi-directional pile load test in sand. Vertical displacement of the model pile were messured at the axial loading condition.

  • PDF

기기기초 시스템의 보강방안에 대한 연구 (Study on Reinforcing Method of Equipment Foundation System)

  • 송영철;최홍식;조명석;우상균;이시우;이성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.367-370
    • /
    • 2003
  • This study was carried out to suggest the effective reinforcing method which can evaluate the tensile capacity of cast-in-place anchor with cracks. Currently, cast-in-place anchor is used widely for the fastening of equipment in Korean NPPs. 26 test specimens with a single anchor under 4 cracked conditions are prepared using plain concrete. The distance between crack and anchor and reinforcing materials were selected as the main test variable. The tensile force was applied using a actuator with a capacity of 100 tonf using a displacement control method of 0.5 mm/min velocity. Test results from this result show the combination of carbon plate and epoxy will be more available for repair and reinforcement of equipment foundation system in NPPs. Further experimental work is indeed involving the epoxy injection effect and adjustment of reinforcing location of carbon sheet.

  • PDF