• 제목/요약/키워드: Vapor refining

검색결과 8건 처리시간 0.02초

종이 물성에 따른 판형 전열교환기의 성능 (Performance of a Plate-Type Enthalpy Exchanger Made of Papers Having Different Properties)

  • 김내현;조진표;송길섭;김동훈
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.547-555
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Papers having different properties were made from the same pulp by calendering or refining. Enthalpy exchanger samples were made from the papers, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were obtained, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that effective efficiency of latent heat transfer was approximately the same independent of the samples, which suggests that papers made of the same pulp show similar water vapor transmission characteristics independent of the degree of calendering or refining. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

유동법에 의한 용융 ZnCl2 및 FeCl2의 증기압 측정 (Measurement of Vapor Pressure of Molten ZnCl2 and FeCl2 by the Transpiration Method)

  • 이우상;김원용;정우광
    • 한국재료학회지
    • /
    • 제20권3호
    • /
    • pp.111-116
    • /
    • 2010
  • Chloride-based fluxes such as NaCl-KCl are used in the refining of Al melt. The vapor pressure of the chloride is one of the fundamental pieces of information required for such processes, and is generally high at elevated temperatures. In order to measure the vapor pressure for chlorides, the apparatus for the transpiration method was assembled in the present study. The vapor pressure of $ZnCl_2$ and $FeCl_2$, which is related with the process of aluminum refining and the recovery of useful elements from iron and steel industry by-products, was also measured. In the measurement of vapor pressure by the transpiration method, the powder of $ZnCl_2$ or $FeCl_2$ in a alumina boat was loaded in the uniform zone of the furnace with a stream of Ar. The weight loss of $ZnCl_2$ and $FeCl_2$ after holding was measured by changing the flow rate of Ar gas (10 sccm -230 sccm), and the partial pressures of $ZnCl_2$ and $FeCl_2$ were calculated. The partial pressures within a certain range were found to be independent of the flow rate of Ar at different temperatures. The vapor pressures were measured in the temperature range of 758-901K for $ZnCl_2$ and 963-983K for $FeCl_2$. The measured results agreed well with those in the literature.

전자선 용해법에 의한 V의 정련 및 용해에 관한 연구 (A Study on Refining and Melting of V by Electron Beam Melting)

  • 김휘준;백홍구;윤우영;이진형;강춘식
    • 한국주조공학회지
    • /
    • 제15권3호
    • /
    • pp.235-241
    • /
    • 1995
  • In order to improve the production process of low cost and high purity Vanadium, this study was done to reduce $V_2O_5$ into V-Al master alloy by Aluminothermic Reduction, followed by refining of V-Al master alloy electron beam melting. As melting time was increased in electron beam melting of V, the contents of interstitial impurities and Al, Fe were decreased but the contents of Si, Mo and W were increased due to lower vapor pressure of these elements than that of matrix V. Consequently, it was profitable that melting of V was done for 180 seconds. In addition, with number of melting, the purity of V did not significantly vary, because volatile impurities in V were removed mostly during the first step of melting. As a result of V refining by electron beam melting, high purity Vanadium of 3N(99.91wt%) was acquired including interstitial impurities total contents of which were maximum 400ppm.

  • PDF

InSb 자속계의 제작과 그 특성에 관한 연구 (Fabrication and Characteristic of an InSb Mognetic Flvxmeter)

  • 윤재강;유용택
    • 대한전자공학회논문지
    • /
    • 제12권6호
    • /
    • pp.5-8
    • /
    • 1975
  • Hall효과의 이용으로, 자계의 세기 또는 자속을 계측할 수 있는 자속계의 제조 및 특성조사를 시도하였다. Hall계수가 큰 InSb의 단결품을 Bridgemann법에 의하여 제작하고, 자장내에서 자계의 세기와 기전력 또는 전류를 계측한 결과, 만족할만한 감도와 직선적인 특성곡선을 얻었으며, 유사한 연구결과와 비교할때, 좋은 결과임을 알게 되었다. An Insb magnetic fluxmeter was made of InSb Single Crystal that was grown by Bridgemannmethods and then purified by vapor cone refining method. We investigated some properties of the InSb magneto fluxmeter. It was found that the resistivity and the Hall Coefficient of this single Crystal Were 4.4X10-2Ω and 4.5cm3/Coul, respectively, at room temperature. The Characteristic Curve of the InSb magnetic fluxmeter between the magnetic field the Hall voltage, with the Current flowing through the element a Parameter, had good lineanty i.e., We obtained a linear Calibration Curve of the flwmeter. The fluxmeter erved the purpose well enough up to 5 k-gaus.

  • PDF

고분자 유기하드마스크 합성에 따른 특성에 관한 연구 (A Study on Characteristics of Polymer Organic Hard Mask Synthesis)

  • 이우식
    • 한국정보전자통신기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.217-222
    • /
    • 2023
  • 본 논문은 제조공정이 단순하고, 공정시간도 매우 짧아 제조원가를 절감할 수 있는 고분자 유기하드마스크를 합성하는데 목적을 두었다. 승화 정제 장치를 통한 잔류금속을 측정한 결과, 9-Naphthalen-1-ylcarbazole(9-NC)은 4th zone에서 101.75ppb, 2-Naphthol(2-NA)은 5th zone에서 306.98ppb, 9-Fluorenone(9-F)는 4th zone에서 5th zone 사이에서 129.05ppb로 측정되었다. 그리고 합성된 유기하드마스크를 필터 시스템을 거친 후 잔류금속을 측정한 결과 9 ~ 7ppb 측정되었다. 또 열분석 변화를 측정한 결과, 2.78%로 감소하였고 분자량은 942로 측정되었고 탄소 함량은 89.74%이고 수율은 72.4%로 나타났다. 에칭 속도는 평균 18.22Å/s로 측정되었고 코팅 두께 편차는 평균 1.19로 측정되었다. 유기하드마스크의 입자크기가 0.2㎛ 이하에서는 입자가 존재하지 않았다. 코팅 속도를 1,000, 1,500, 1,800rpm으로 변화를 주어 코팅 두께를 측정한 결과, 수축률은 17.9에서 20.8%까지 측정되었고 코팅 결과 SiON과 접착력이 우수하고 유기하드마스크가 균일하게 도포되었음을 알 수 있었다.

Electron Beam Floating Zone Melting에 의한 몰리브덴의 정련 및 단결정 성장에 관한 연구 (Purification and Single Crystal Growth of Molybdenum by Electron Beam Floating Zone Melting)

  • 최용삼;지응준
    • 한국결정학회지
    • /
    • 제3권2호
    • /
    • pp.85-97
    • /
    • 1992
  • EBFZM( Electron Beam Floating Zone Melting) 법을 이용하여 몰리브덴에서의 금속계 불순물과 침입형 불순물의 정련기구 및 단결정 성장기구를 연구하 였다. Fe, Cr, Co등의 금속계 불순물은 몰리브덴과의 평형증기압의 차이에 따른 불순물의 선택적 증발에 의하여 우수한 정련효과를 나타내며, 몰리브덴보다 응점이 높은 Ta, W는 잘 제거되지 않았다. 한편 대역 정제에 의한 정련효과는 미약함을 확인하였다. EBF ZM은 C,0,N등의 침입형 불순물의 정련에도 효과적 이었다. 본 연구의 모든 조건에서 몰리브덴은 단결정으로 성장하였으며 2차 재결정 epitaxy에 의한 단결 정 성장기구가 제시되었다. 몰리브덴 단결정 내의 전 위밀도는 strain-anneal법에 의한 단결정의 경우보다 높았으며,본 실험의 열처리 조건에서는 변화하지 않았다. The purification and single crystal growth mechanisms of molybdenum were analysed in EBFZM ( electron beam floating zone melting). Metallic impurities of Fe, Cr, Co were purified efficiently but Ta and W were not removed well in this study. It was due to a preferential evaporation of the elements caused by the difference in equillibrium vapor pressure between the elements and molybdenum. The pu- rification effect by zone refining was not significant. The EBFZM also refined the interstitial impurities of C, 0 and N, effectively. The single crystals of molybdenum were grown regardless of the experimental conditions and the secondary recrystallization epitaxy was surge sled as a growth mechanism. The dislocation density in single crystal was higher than that by strain-anneal method, and was not reduced by heat treatments.

  • PDF

환경대기 중 저분자 PAHs 측정을 위한 흡착-열탈착-GC/MS 방법의 적용 (Application of Adsorption Sampling and Thermal Desorption with GC/MS Analysis for the Measurement of Low-Molecular Weight PAHs in Ambient Air)

  • 서석준;서영교;황윤정;정동희;백성옥
    • 한국대기환경학회지
    • /
    • 제30권4호
    • /
    • pp.362-377
    • /
    • 2014
  • Polycyclic aromatic hydrocarbons (PAHs) have been of particular concern since they are present both in the vapor and particulate phases in ambient air. In this study, a simple method was applied to determine the vapor phase PAHs, and the performance of the new method was evaluated with a conventional method. The simple method was based on adsorption sampling and thermal desorption with GC/MS analysis, which is generally applied to the determination of volatile organic compounds (VOCs) in the air. A combination of Carbotrap (300 mg) and Carbotrap-C (100 mg) sorbents was used as the adsorbent. Target compounds included two rings PAHs such as naphthalene, acenaphthylene, and acenaphthene. Among them, naphthalene was listed as one of the main HAPs together with a number of VOCs in petroleum refining industries in the USA. For comparison purposes, a method based on adsorption sampling and solvent extraction with GC/MS analysis was adopted, which is in principle same as the NIOSH 5515 method. The performance of the adsorption sampling and thermal desorption method was evaluated with respect to repeatabilities, detection limits, linearities, and storage stabilities for target compounds. The analytical repeatabilities of standard samples are all within 20%. Lower detection limits was estimated to be less than 0.1 ppbv. In the results from comparison studies between two methods for real air samples. Although the correlation coefficients were more than 0.9, a systematic difference between the two groups was revealed by the paired t-test (${\alpha}$=0.05). Concentrations of two-rings PAHs determined by adsorption and thermal desorption method consistently higher than those by solvent extraction method. The difference was caused by not only the poor sampling efficiencies of XAD-2 for target PAHs and but also sample losses during the solvent extraction and concentration procedure. This implies that the levels of lower molecular PAHs tend to be underestimated when determined by a conventional PAH method utilizing XAD-2 (and/or PUF) sampling and solvent extraction method. The adsorption sampling and thermal desorption with GC analysis is very simple, rapid, and reliable for lower-molecular weight PAHs. In addition, the method can be used for the measurement of VOCs in the air simultaneously. Therefore, we recommend that the determination of naphthalene, the most volatile PAH, will be better when it is measured by a VOC method instead of a conventional PAH method from a viewpoint of accuracy.

고농도 수은 노출자의 혈 중 및 뇨 중 수은 농도 변화에 관한 연구 (Patterns of Mercury Concentrations in Blood and Urine After High Mercury Exposure)

  • 윤충식;임상혁;하권철
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.71-80
    • /
    • 2001
  • Blood and urine mercury level of three workers were monitored during 60~80 days after high exposure to mercury at the silver refining plant. Mercury was used to form silver-mercury amalgam from plating sludge. Workers were exposed to mercury about 70 days at the several processes, such as hand held weaving, vibration table, and heating from the furnace. mercury was analysed by atomic absorption spectroscopy-vapor generation technique. Recovery from the biological sample was 95.51% and pooled standard deviation was 0.033. At the time of study, there was no work at the workplace. So, airborne mercury concentration was measured with area sampling 5 days after the work, ranged from 0.1459 to 1.2351 mg/㎥(Arithmatic mean 0.4711 mg/㎥, Geometric mean 0.3566 mg/㎥) at the inside of the plant, that is far above the ACGIH's TLV(0.025 mg/㎥) and ranged from 0.0073 to 0.0330 mg/㎥ at the outdoor. Blood mercury levels at the beginning of the monitoring were 4~14 times greater than the American Conference of Governmental Industrial Hygienists Biological Exposure Index(ACGIH BEI, 15 ug/L). Blood mercury levels were decreased logarithmically, that is, rapidly at the high level and slowly at the low level but sustained above the level of the ACGIH BEI 60~80 days after the work. Urine mercury levels at the beginning of the monitoring were 8~16 times greater than the ACGIH BEI(35 ug/g creatinine). Urine mercury levels were decreased logarithmically, but correlation between urine level and off-days were lower than those of blood. Decreasing pattern of blood mercury levels were little affected than that of urine levels when the chelating agent, D-penicillamine, was administered. There was correlation between blood mercury level and urine mercury level(0.81~0.83) but it didn\`t mean that the highest blood mercury level corresponded the highest urine mercury level. In our study, Case 1 always shows the highest level in urine but case 3 always shows the highest level in blood. Creatinine correction represented better correlations between urine mercury levels and blood levels, and between urine levels and off-days rather than by urine volume. Spot urine sampling had a wide variation than that of whole day urine sampling. So, We recommend spot urine sampling for screening and whole day urine sampling for exact diagnosis.

  • PDF