• Title/Summary/Keyword: Vapor recovery system

Search Result 41, Processing Time 0.023 seconds

Experimental Study on the Interference of Water Vapor on the Chemical Ionization of OH by Sulfur Hexafluoride Ion

  • Park, Jong-Ho
    • Mass Spectrometry Letters
    • /
    • v.5 no.4
    • /
    • pp.120-123
    • /
    • 2014
  • The interference of water vapor on the chemical ionization (CI) of hydroxyl radicals (OH) by sulfur hexafluoride ion ($SF_6{^-}$) was investigated using a flow tube system coupled to a high-pressure CI mass spectrometer. Water vapor, which is required to study heterogeneous reactions of OH under real tropospheric conditions, transforms the reagent ion $SF_6{^-}$ into $SF_4O^-$ and $F^-(HF)_n$, resulting in a substantial loss in CI sensitivity. Therefore, under humid conditions, peaks corresponding to OH are drastically diminished, while those corresponding to OH-water complex ions ($[OH(H_2O)_n]^-$) are enhanced. $[OH(H_2O)_3]^-$ was observed as the major OH species. The obsercation of $[OH(H_2O)_n]^-$ by isolating humid conditions to the CI region and preliminary ab initio calculations suggested that $[OH(H_2O)_n]^-$ ions were produced from reactions between OH ions ($OH^-$) and water molecules. An additional helium buffer flow introduced into the CI region reduced loss of the reagent ion and resulted in a partial recovery of OH peak intensities under humid conditions.

Performance Characteristics of Refrigeration Cycles with Ejector using Refrigerants (이젝터를 적용한 냉동사이클의 냉매종류별 성능특성)

  • Yoon, Jung-In;Kim, Chung-Lae;Son, Chang-Hyo
    • Journal of Power System Engineering
    • /
    • v.21 no.1
    • /
    • pp.24-29
    • /
    • 2017
  • Studies in liquid-vapor ejector, which performs a great efficiency in refrigeration cycle is highly concerned. This paper is based on basic refrigeration cycle and three ejector refrigeration cycles and the comparison and contrasts about when 6 different refrigerants are applied to such refrigeration cycles. All cycles had a percentage increase of COP from 4 to 74% when ejector was applied, and the source of increasement was the decrease of total work done due to ejector's pressure recovery function. When R-245fa is applied to cycle (d), results showed that COP was the most superior in such cycle, R-245fa showed high volume entrainment ratio in all cycles. Future studies in refrigeration cycles will require more knowledge and experiments on ejector's appliance to refrigeration cycles and the actuation of such functions.

Study on the Thermal Characteristics of Organic Rankine Cycles for Use of Low-Temperature Heat Source (저온열원 활용을 위한 유기랭킨사이클의 열적 특성에 관한 연구)

  • Jin, Jae-Young;Kim, Kyoung-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.191-194
    • /
    • 2011
  • Low-grade waste heat has generally been discarded in industry due to lack of efficient recovery methods. In recent years, organic Rankine cycle(ORC) has become a field of intense research and appears as a promising technology for conversion of heat into useful work of electricity. In this work thermodynamic performance of ORC with superheating of vapor is comparatively assessed for various working fluids. Special attention is paid to the effects of system parameters such as the evaporating temperature on the characteristics of the system such as maximum possible work extraction from the given source, volumetric flow rate per 1 kW of net work and quality of the working fluid at turbine exit as well as thermal efficiency.

  • PDF

A Cost Analysis of the Heat Recovery Ventilator under Various Condition (열회수형 환기장치의 운전조건에 따른 경제성 평가에 관한 연구)

  • Kang, Tae-Wook;Koh, Jae-Yoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Changes in building construction methods and repairing of older buildings have reduced infiltration rate. Synthetic materials, release airborne particles and uneven healthy odor are increased. For preventing pollutants introduce fresh outdoor air into the building, simply letting fresh outdoor air into building, however, Is not a cost-effective way to ventilation. When additional ventilation is added to an existing HVAC system, the heating and cooling equipment, often cannot handle the increased load. A HRV provides a way to minimize in energy costs while introducing fresh air to a building. In this study, the economical research of HRV, made of three types of materials, are conducted. Heat recovering characteristics are studied at seasonal outdoor air conditions based on the outdoor air property condition at, Seoul in 2002. As a results, the average sensible effectiveness is 0.75 in the sensible heat exchanger and average total effectiveness is 0.65 in the total heat exchanger. The pay back period of the sensible heat exchangers are $3.2{\sim}3.5$ year and it of total heat exchanger is 2.2 years.

Developing Unity BLDC motor controller adding TCP/IP for Vapor Recovery System (TCP/IP 기반 유증기 회수용 제어기 일체형 BLDC모터 개발)

  • Kim, Duck-young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.4
    • /
    • pp.3-9
    • /
    • 2010
  • Recently, Applications of BLDC motor have grown gradually in energy savings and controls of speed and torque. But most of BLDC motors need controller and driving circuits aside from motor, according to various situations. In this paper, it was designed for a embedded controller and motor including microprocessor that programmable intelligent control as various circumstances. And in order that the user conveniently use better than to use web browser using TCP/IP module in controller.

  • PDF

Analysis of Hydrogen Fuel for Existing Domestic Boilers and New Heat Recovery Boilers with Water Spray (기존 가정용 보일러 및 신형 물분사 폐열회수 보일러에 대한 수소 연료의 평가)

  • LEE, CHANG-EON;KIM, DAEHOON;PARK, TAEJOON;MOON, SEOKSU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.2
    • /
    • pp.210-222
    • /
    • 2020
  • Hydrogen is evaluated as one of new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is free from CO2, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. This study investigates the differences in operating characteristics and its problems to be modified when the hydrogen is used as fuel for existing domestic boilers and new heat recover boilers with water spray. When the hydrogen is used in domestic boilers, the efficiency is about 6-7% lower than methane due to higher partial vapor pressure in the exhaust gas at usual operating conditions above 60℃ in combustion chamber outlet temperature. On the other hand, the heat recovery boiler with water spray (HR-B/WS-X) is expected to achieve up to 95% efficiency, which is 12% more efficient than conventional boilers. It can also significantly reduce NOx emission by lowering the flame temperature.

An Analysis of the Application Technology of Heat Recovery System from Dyeing Wastewater (염색폐수 열회시스템 적용기술 분석)

  • 장기창;박성룡;이상남;라호상;박준택;함성원;박영태
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.195-205
    • /
    • 2001
  • A great deal of energy is necessary with emission of lots of wastewater in dyeing and finishing process, but heat recovery from wastewater is not introduced since is technology is not developed yet. In order to obtain the method utilizing hot water produced by heat source, that is, dyeing wastewater it was investigated the characteristics of dyeing and finishing process and energy basic unit. Energy basic unit of polyester/cotton (T/C), polyester/rayon (T/R) and polyester dyeing process are higher than that of the other process. The average quantity of wastewater for each dyeing company is 20,470 ton/month, the average temperature of wastewater is about 41$^{\circ}C$. Because the SS solution of wastewater in polyester dyeing process is lower than that of the other process, the effect of corrosion in heat recovery system is low. Since the energy price for 1000 kcal produced by vapor compression heat pump is presumed to be 22.50 won, it is found to be very economic heat recovery system, and its payback is 2.09 years for the factory with LNG boiler.

  • PDF

Dimensional Stability of Plastic Processing Wood Material - Compression Wood and Bentwood -

  • Hwang, Kweon-Hwan;Lee, Won-Hee
    • Journal of the Korea Furniture Society
    • /
    • v.18 no.2
    • /
    • pp.143-146
    • /
    • 2007
  • This study was carried out to assess the dimensional stability of wood material treated by plastic processing for bentwood and compression wood. The evaluation method was different between two wood materials, but the treatments for them were very similar to each other. One of the main methods is heat treatment with sufficient water vapor. In bentwood, the used species were painted maple (Acer mono), bitter wood (Picrasma quassioides) and birch (Betula schmidtii). Steaming was the worst treatment method for dimensional stabilization of bentwood. The best results could be attained with PEG treatment for dimensional stabilization of bentwood. Dimensional stability of bitter wood was found to be conspicuous. However the steaming treatment at lower temperatures, i.e., about $130^{\circ}C$ was not suitable for dimensional stability of bentwood. In compression wood, the used specimen was Italian poplar wood (Populus euramericana). Two heat compressive pressing conditions, an open-press system and an air-tighten closed-press system, were used. The recovery rate was measured after boiling and/or absorbing in water to estimate the dimensional stability of heat compressed wood. The best dimensional stability of compressed wood in the air-tighten closed-press system was found to be better at $200^{\circ}C$ than $180^{\circ}C$. The best compression rate for dimensional stability was 73 percent.

  • PDF

Development of Reuse Process Through Recovery and Refinement of Precursor for LED (LED용 precursor 재이용을 위한 회수 및 정제 공정 개발)

  • Yang, Jae Yeol;O, Byung Sung;Yoon, Jae Sik
    • Resources Recycling
    • /
    • v.23 no.1
    • /
    • pp.25-32
    • /
    • 2014
  • The purpose of this research is to develop a process and a system to collect, purify and reuse the residual quantity of trimethylgallium, used as a raw material, upon GaN epitaxial growth for LED from a metal organic chemical vapor deposition(MOCVD) equipment. This research reviews whether TMGa collected from the process can be used through a chemical and structural characteristics evaluation. As a result of analyzing the purity using ICP-MS and ICP-AES, 7N high purity (99.99999%) of TMGa was obtained. According to checking the structural change of TMGa through NMR analysis, TMGa having pure $(CH_3)_3Ga$ structure was obtained without structural change. For reliability review of the collected TMGa, u-GaN was deposited using the MOCVD process and an structural, optical and electrical characteristics evaluation was conducted. As a result, it was found out that the reuse was possible.

Sensing characteristics of Polypyrrole-based methanol sensors preparedbyin-situ vapor state polymerization

  • Linshu Jiang;Jun, Hee-Kwon;Hoh, Yong-Su;Lee, Duk-Dong;Huh, Jeung-Soo
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.137-137
    • /
    • 2003
  • Conducting PPy/PVA composite and pure PPy gas sensors were prepared by in-situ vaporstate polymerization method in a vaporization chamber under N2 condition, by exposing the pre-coated electrode with PVA/FeC13 to distilled pyrrole monomer. The various electrical sensing behaviors of both types of sensors were systematically investigated by a flow measuring system including mass flow controller (MFC) and bubbling bottle. The FT-Raman spectroscopy of vapor state polymerized PPy was identical to that of chemically polymerized PPy, confirming the same chemical structure. Both types of sensors had positive sensitivity when exposed to methanol gas. The sensitivity varied linearly with gas concentration in the range of 50ppm to 1059ppm. The detection limit of PPy/PVA sensor was believed to be as low as 10ppm. The sensitivity of PPy/PVA composite sensor was higher than that of pure PPy sensor. Both the response time and recovery time of PPy/PVA composite sensors were longer than those of pure PPy sensors. The thickness of the sensing film affected the sensitivity this way that the sensor having thinner film had higher sensitivity, indicating that the resistance of polymer film involved in the sensing behavior was bulk resistance rather than surface resistance. The reproducibility of PPy/PVA composite sensor was excellent during eight on-off cycles by switching between N2 and 3000ppm methanol gas. The sensitivity of PPy/PVA composite sensor was only maintained for two weeks, while the sensitivity of pure PPy sensor was maintained over two months.

  • PDF