• Title/Summary/Keyword: Vapor recovery system

Search Result 41, Processing Time 0.043 seconds

A Study on Urinary Trans, Trans-Muconic acid, Hippuric acid of gas station worker according to the use of gasoline vapor recovery system (유증기 회수설비 유무에 따른 주유소 근로자들의 요중 trans, trans-Muconic acid, Hippuric acid에 관한 연구)

  • Choi, Jaejun;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.152-159
    • /
    • 2014
  • Objectives: This study aims to investigate the excretion aspect of urinary t, t-MA and hippuric acid by measuring concentrations of urinary metabolites according to the use of gasoline vapor recovery system. Materials:In order to analyze urinary metabolites, samples from the 23 gas station workers ten gas stations in the Seoul and Gyeonggi Province area were collected once daily after work. In addition, a survey was conducted on work factors and lifestyle habits as factors affecting the concentration of urinary metabolites. Results: The average concentrations of t, t-MA and hippuric acid after work were $0.124{\pm}0.177mg/g$ creatinine and $0.557{\pm}0.251g/g$ creatinine among workers at gas stations where gasoline vapor recovery systems were installed. The average concentrations of t, t-MA and hippuric acid were $0.160{\pm}0.113mg/g$ creatinine and $0.682{\pm}0.619g/g$ creatinine among workes at gas stations where gasoline vapor recovery systems were not installed. Average concentrations were higher at gas stations where a gasoline vapor recovery system was not installed, but the differences were not statistically significant differences. Urinary t, t-MA and hippuric acid average concentrations of smokers and non-smokers were higher in the gas stations where gasoline a vapor recovery system was not installed. T, t-MA as a factor evaluation affecting the concentration of urinary metabolites was not statistically significant in all factors, while hippuric acid was statistically significant only for age(p=0.024). Conclusions: The average concentrations of urinary t, t-MA and hippuric acid were higher in gas stations where gasoline vapor recovery systems were not installed compared to gas stations where such a system was installed. There needs to be an assessment of biological monitoring according to refueling activity considering skin absorption of benzene and toluene and presence of gasoline vapor recovery system.

Occupational Exposure Aspects of Gasoline Vapor According to the Use of a Gasoline Vapor Recovery System (주유소 유증기 회수설비 사용에 따른 가솔린 증기의 개인노출양상)

  • Lee, Heemyung;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.156-165
    • /
    • 2015
  • Objectives: The purpose of this study was to investigate the possible effects of a gasoline vapor recovery system on personal exposure levels of gasoline vapor constituents including benzene, toluene, ethyl benzene, xylene(BTEX), and methyl tert-butyl ether(MTBE) among gas station workers in a metropolitan area. Methods: Thirty-one gas station workers at ten gas stations in a metropolitan area were selected as subjects for this study. Test method PV2028 as recommended in the OSHA process was used for sampling and analysis. Results: The personal exposure levels of benzene, toluene, ethyl benzene, xylene, MTBE and gasoline vapor in the gas station workers were $0.0018{\pm}0.0069ppm$, $0.0077{\pm}0.0137ppm$, $0.0002{\pm}0.0008ppm$, $0.0016{\pm}0.0084ppm$, $0.2619{\pm}0.3340ppm$, and $1.4940{\pm}1.7984ppm$, respectively. After adjustment for refueling frequency and volume, personal exposure levelswere higher in the gas stations where gasoline vapor recovery systems(Stage II) were not installed, but the results were not statistically significant. Gasoline vapor concentrations showed a positive correlation to the level of MTBE, a gasoline additive. Conclusions: Vapor recovery systems(Stage II) were effective not only in reducing emissions of air pollutants, but also in reducing exposure to hazardous substances among gas station workers. In addition, acorrelation between gasoline vapors and MTBE concentration was confirmed.

A Study on the Calculation Method of VOCs Emissions Using Equation of State in the Gas Station Tank (상태방정식을 이용한 주유소 탱크에서의 유증기 배출량 산정법에 관한 연구)

  • Park, Taejoon;Oh, Wheesung;Lee, Chang-Eon
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.4
    • /
    • pp.42-48
    • /
    • 2015
  • This study was investigated the estimation of VOCs (Volatile Organic Compounds) emission from a gas station tank. To improve the atmosphere environmental quality near the gas station, the installation of vapor recovery system has been expanded recently. Therefore, it was necessary to calculate VOCs emissions from the gas station tank with vapor recovery systems for evaluation of their performance. The VOCs emissions are difficult to measure directly because of various sources and irregularly emission by pressure rise. In this study, VOCs emissions were estimated by simple calculation based on the equation of state for measured pressure, temperature and volume of a gasoline tank at a gas station. The result confirmed that the present national emission factor did not have significant discrepancy with the calculated value.

Evaluation of Air Quality with and without Vapor Recovery Systems of Stage II (주유소 Stage II의 유증기회수설비 가동에 따른 대기질 평가)

  • Kim, Jae Hyuck;Jung, Seok Hyeon;Kim, Hyung-Seok;Jang, Tae-Hyuk;Yoo, Kyung Seun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.801-810
    • /
    • 2013
  • A field study was conducted to evaluate air quality from gas stations with and without Stage II vapor recovery systems that are currently used to reduce VOCs. The THC and VOCs levels were monitored for the test at three locations (inside office, around refueling area, site boundary) from a total of five gas stations. The results showed a considerable reduction in THC concentration which ranged from 48.7% to 81.8% with and without the operation of the Stage II VRS. Acoording to our comparative analysis, BTEX and other 19 VOCs levels were also significantly reduced with Stage II vapor recovery systems.

The implementation of liquefaction equipment monitoring system based on Android (안드로이드 기반의 유증기 액화장치 모니터링 시스템 구현)

  • Park, Man-Kyu;Tack, Han-Ho;Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.583-589
    • /
    • 2016
  • Volatile organic compounds(VOCs) are regarded as a harmful cause substance not only causing air pollutions but also causing global warming phenomenon. For this reason, VOCs are managed politically to reduce emissions by each country. In particular, the vapor from the gas station contains VOCs which is harmful to the human body such as carcinogens benzene and pollute the atmosphere, the Ministry of Environment defined every gas station must install vapor recovery equipment to recover volatile organic compounds. Recently, there are many accidents caused by existing vapor treatment methods, the liquefaction recovery technology is getting the spotlight to cool the vapor at the field. However, because the liquefaction recovery technology have risks of fire or explosion in accordance with temperature, the real time monitoring is critical factor. In this paper, we implement an Android-based monitoring application for liquified vapor recovery device which attached sensor module for temperature and power to monitoring real time information.

A Study on the Safety Assessment of Alternative Safety Devices Replacing Liquid Seal in Ship Vapor Recovery Unit (선박 유증기 회수설비의 Liquid Seal 대체 안전설비 안전성 평가 방안에 대한 연구)

  • Park, Beom-Jin;Kang, Hee-Jin;Choi, Jin;Lee, Dong-Kon
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.114-116
    • /
    • 2011
  • By 33 CFR 154.828 regulation, a liquid seal must be installed on the inlet to vapor destruction unit in vapor control system. However, install and maintenance of liquid seal are subject to many problems in ship environment. Therefore, US Coastguard, which is the governing body of the regulation, have prepared another clause in the regulation for the exemption from previous clauses. In this paper, relevent regulation is reviewed, together with the requirements for exemption from liquid seal installation. A previous example case is also studied to propose how safety assessment for the alternative safety devices replacing liquid seal should be performed.

  • PDF

Performance Test for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy (해수열원 및 폐열이용 고성능 열펌프 시스템 성능실험)

  • 최광일;오종택;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.979-986
    • /
    • 2003
  • The performance characteristics of heating and cooling operation for a heat pump system using seawater heat source and exhaust energy are presented. The heat pump system is made of a waste heat recovery system and a vapor compression refrigeration system. The working fluid is R-22. The heat pump system COPs are measured during heating and cooling operation modes, and the resultant COPs were 9.7 and 7.9, respectively, which are three times higher than those of the heat pump itself. Therefore, the performance of the heat pump system using exhaust energy is excellent compared to that of a general heat pump. The experimental data can be effectively used for the design of the high efficient heat pump using a seawater heat source.

An Analytical Investigation on Fluid Dynamics of Filler Neck Check Valve for On-board Refueling Vapor Recovery (주유중 증발가스제어 필러넥 체크밸브의 유동해석)

  • 김성훈;이재천
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.105-111
    • /
    • 2003
  • ORVR filler neck check valve, which is one of the essential components of the vapor fuel control system, should diminish the evaporation by maintaining laminar fluid flow on refueling process. This study presents numerical. results of pressure and velocity distributions of the fluid flow in a ORVR filler neck check valve on refueling process. CFD-ACE+ has been employed for numerical analysis based on the information of experimental results of valve position as a function of inlet flow rate. No abrupt pressure change, which may causes vaporization of fuel, has been confirmed to take place on the concave surface of the valve spool. However, it is clear that some possibility exist at the mid-position of surface of valve spool and downstream according to the opening of valve.

Analysis of a Continuous and Instantaneous Vacuum Drying System for Drying and Separation of Suspended Paricles in Waste Solvent (폐용제에 함유된 입자의 건조 및 분리용 연속식 순간 진공건조시스템 해석)

  • 구재현;이재근
    • Resources Recycling
    • /
    • v.9 no.4
    • /
    • pp.28-36
    • /
    • 2000
  • This study describes to analyze the characteristics for separation and recovery of both the dried particles and the purified solvent from the waste solvent through the vaporization process by the continuous and instantaneous vacuum drying system. The vacuum drying system for the waste solvents recovery consists of a feeding pump, a double pipe heat exchanger, a vacuum spray chamber, and a condenser. The vacuum drying system heats the waste solvent to the vapor in the double pipe heat exchanger and the expanded vapor is sprayed at the end of the tube. The vaporized solvent in the condenser are recovered. The particles in the waste solvent are separated and dried from the vapor in the vacuum spray chamber. Performance evaluation of the vacuum drying system was conducted using the mixture of the dried pigment particles and benzene or alkylbenzene as test samples. For the mixture of 10 wt% pigment particles an 90% benzene, the recovery efficiency of benzene was 88% with the purity of 99% and the recovery efficiency of dried particles was 94% with the moisture of 1.1 wt%. The size of pigment particles was decreased from $6.5\mu\textrm{m}$ to $5.6\mu\textrm{m}$ in diameter due to high speed spraying and dispersion in the vacuum drying system during drying process. Therefore, the vacuum drying system showed to be an effective method for separating particles and solvent in the waste solvent.

  • PDF

Performance Analysis of 1MW Organic Rankine Cycle with Liquid-Vapor Ejector using Effluent from Power Plant (화력발전소 폐열에 따른 작동유체별 액-증기 이젝터를 적용한 1MW급 ORC의 성능 분석)

  • Kim, Hyeon-Uk;Yoon, Jung-In;Son, Chang-Hyo
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.120-125
    • /
    • 2014
  • In this paper, suitable working fluid of 1MW Organic Rankine Cycle(ORC) with liquid-vapor ejector using effluent from power plant is selected. The results of comparison performance of 5 refrigerants are as follows; R600a, R134a, R1270, R236fa, R235fa. The operating parameters considered in this study include the condensation capacity evaporation capacity and efficiency. As a result of comparison of basic ORC system and with liquid-vapor ejector, with ORC system presents the higher system efficiency since the ejector makes the turbine outlet pressure lower than condensation pressure through its pressure recovery. Also, this ejector ORC system is advantageous in miniaturizing the size of components owing to decrease of evaporation capacity and condensation capacity.