• 제목/요약/키워드: Vapor absorption

검색결과 324건 처리시간 0.023초

목재의 흡방습에 관한 연구 - 수종에 의한 흡방습성의 차이 - (Studies on Absorption and Desorption Wood - Difference of Absorption and Desorption Behavior of Wood -)

  • 이원희
    • Journal of the Korean Wood Science and Technology
    • /
    • 제19권4호
    • /
    • pp.52-61
    • /
    • 1991
  • In this paper, the difference of the property of absorption and desorption for five species in semi-steady state are studied. The species used are listed in Table 1 and the dimension of specimen was $8\times8{\times}T$(Tangential direction)cm and tested in various conditions. A change of average moisture content with time were measured in each cycles. The results obtained are summarized as follows. When the relative humidity in air was maximum or minimum, the distribution of moisture In wood of all specimens were illustrated by exponential curves of decrease or increased from lace 10 center of wood. From the consideration of coefficient of decrease(C), the amount of moisture change of spruce was larger than the others. The pheonomenon was considered no relation to the specific gravity in air dry, but the wood structures. The velocity of the absorption and desorption for species decreased in the order spruce(Picea sitchensis) neodobam(Fagus crenata), solsong(Tsuga heterophylla), meranti(Shorea sp.) and kaesoo(Cercidiphyllum japoicum). In case of constant temperature and water vapor pressure is changed. the amount of absorbed moisture was larger than that of constant water vapor pressure and temperature vaned. In this fact, it is considered that the property of sorption of wood is strongly influenced by vapor pressure gradient than temperature gradient.

  • PDF

수평원관상의 LiBr-수용액에 수증기가 흡수될때의 열 및 물질전달 (Coupled Heat and Mass Transfer during the Absorption of Water Vapor into LiBr-H2O Liquid Solution Flowing down the Outside of the Horizontal Cylinder)

  • 이관수;서석청;김영인;박동규
    • 대한설비공학회지:설비저널
    • /
    • 제17권2호
    • /
    • pp.140-149
    • /
    • 1988
  • The problem of heat and mass transfer accompanying the absorption of water vapor into LiBr-$H_2O$ liquid solution flowing over the outside of the horizontal cylinder was theoretically studied to understand the absorption process occuring in the absorber of the absorption heat pump. Numerical results are presented for various quantities of interest relating to temperature, concentration, heat flux and mass flux. Also, the effects of mass flowrate, initial average velocity, and the radius of the cylinder were investigated.

  • PDF

경(硬)갚셀제(劑)의 흡습(吸濕)에 관(關)한 연구(硏究) (Studies on Water Vapor Absorption through Hard Gelatin Capsules)

  • 박종훈
    • Journal of Pharmaceutical Investigation
    • /
    • 제3권3호
    • /
    • pp.16-19
    • /
    • 1973
  • Stability is impaired in capsules in which there is a transfer of water vapor from capsule to the contents of the capsules. The water vapor transfer between AEA-coated capsules and corn starch, magnesium trisilicate in the closed container was examined. Experimental eguilibrium relative humidity after water vapor transfer and estimated values calculated from a formula of these substances were in close agreement with each other.

  • PDF

Non-absorbable Gas Effects on Heat and Mass Transfer in Falling Film Absorption

  • Kim, Byongjoo;Lee, Chunkyu
    • Journal of Mechanical Science and Technology
    • /
    • 제17권4호
    • /
    • pp.581-589
    • /
    • 2003
  • Film absorption involves simultaneous heat and mass transfer in the gas-liquid system. While the non-absorbable gas does not participate directly In the absorption process. its pretence does affect the overall heat and mass transfer. An experimental study was performed to investigate the heat and mass transfer characteristics of LiBr-H$_2$O solution flow ing over 6-row horizontal tubes with the water vapor absorption in the pretence of non-absorbable gases. The volumetric concentration of non-absorbable gas, air, was varied from 0.17 to 10.0%. The combined effects of the solution flow rate and its concentration on the heat and mass transfer coefficients were also examined. The presence of 2% volumetric concentration of air resulted in a 25% reduction in the Nusselt number and 41% reduction in the Sherwood number Optimum film Reynolds number was found to exist at which the heat and mass transfer reach their maximum value independent of air contents. Reduced Nusselt and Sherwood numbers. defined as the ratio of Nusselt and Sherwood numbers at given non-absorbable gas content to that with pure water vapor, were correlated to account for the reduction in the heat and mass transfer due to non-absorbable gases in a falling film absorption process.

우드세라믹을 첨가한 기능성 한지가 실내습도 조절에 미치는 영향 (Effect of Functional Hanji Using Wood Ceramics on Indoor Humidity Control)

  • 임현아;오승원;강진하
    • 펄프종이기술
    • /
    • 제38권2호
    • /
    • pp.35-42
    • /
    • 2006
  • This study was carried out to develop a new application field of traditional Hanji and obtain the basic data for producing functional Hanji using sawdust ceramics and rice-husk ceramics as an architectural material. The results measuring water vapor permeance and water vapor absorption for using window materials and wallpapers are as follows. Hanji wallpaper has good things in controlling indoor space comfortably. Particularly, ability of controlling humidity of Hanji wallpaper affects indoor space comfort and human health. In the case indoor humidity is higher than outdoor humidity, according to the addition of ceramics, Hanji wallpapers maintain the humidity by retaining water vapor molecules in the pores of ceramics. Thus the Hanji wallpapers with ceramics, in particular rice-husk ceramics, make it superior to non-ceramics Hanji wallpapers in maintaining the humidity indoors.

Study on High Performance and Compact Absorber Using Small Diameter Heat Exchanger Tube

  • Yoon Jung-In;Phan Thanh Tong;Moon Choon-Geun;Kim Eun-Pil;Kim Jae-Dol;Kang Ki-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.463-473
    • /
    • 2006
  • The effect of tube diameter on heat and mass transfer characteristics of absorber in absorption chiller/heater using LiBr solution as a working fluid has been investigated by both of numerical and experimental study to develop a high performance and compact absorber. The diameter of the heat exchanger tube inside absorber was changed from 15.88mm to 12.70mm and 9.52mm. In numerical study a model of vapor pressure drop inside tube absorber based on a commercial 20RT absorption chiller/heater was performed. The effect of tube diameter, longitudinal pitch, vapor Reynolds number, longitudinal pitch to diameter ratio on vapor pressure drop across the heat exchanger tube banks inside absorber have been investigated and found that vapor pressure drop decreases as tube diameter increases, longitudinal pitch increases, vapor Reynolds number decreases and longitudinal pitch to diameter ratio increases. In experimental study, a system includes a tube absorber, a generator, solution distribution system and cooling water system was set up. The experimental results shown that the overall heat transfer coefficient, mass transfer coefficient. Nusselt number and Sherwood number increase as solution flow rate increases. In both of study cases, the heat and mass transfer performance increases as tube diameter decreases. Among three different tube diameters the smallest tube diameter 9.52mm has highest heat and mass transfer performance.

건조분말 식품의 수분 특성에 관한 비교 연구 (Characteristics of Water Vapor Sorption Phenomena of Powdered Foods)

  • 박길동;김동원
    • Journal of Ginseng Research
    • /
    • 제6권1호
    • /
    • pp.30-37
    • /
    • 1982
  • This study was conducted to investigate the water vapor permeability of packaging film, Al- foil laminated paper, and sorption properties of dehydrated and powdered foods. The results are as fellows. 1. Absorption rate of each products was greately affeoted by physicochemical properties of foods rather than initial moisture contents of the products. 2. The absorption rate of each products were in the order of freeze dried coffee, spray dried coffee, freeze drie4 ginseng extract, spray dried ginseng extract, ginger tea, black tea, citrus juice Powder and ssang wha tea. 3. Most of the products such as freeze dried coffee, spray dried coffee, freeze dried ginseng extract, ginger tea and black tea have shorter than a month of shelf life. 4. The stability of the products were greatly affected by its desorption properties than the degree of desorption of moisture. 5. Water vapor permeability of packaging materials which are laminated Al-foil with polythylene and glassin paper were mainly affected of thickness of Al-foil and polyethylene.

  • PDF

암모니아/물 흡수식 냉동기의 대향류 판형 재생기의 수치모델

  • 지제환;정은수;정시영
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.1034-1041
    • /
    • 2001
  • A numerical model which simulates the flow boiling process of the ammonia/water solution within a plate type generator for ammonia/water absorption refrigerators was developed. The ammonia/water solution flows downward under gravity and the ammonia/water vapor generated by flow boiling flows upward. The heating medium flows counter to the ammonia/water solution. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phases were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the heating medium inlet temperature, the mass flow rate of the heating medium and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF

Optimization of Diode-pumped Cesium Vapor Laser Using Frequency Locked Pump Laser

  • Hong, Seongjin;Kong, Byungjoo;Lee, Yong Soo;Oh, Kyunghwan
    • Current Optics and Photonics
    • /
    • 제2권5호
    • /
    • pp.443-447
    • /
    • 2018
  • We propose a diode-pumped cesium laser using frequency locking of a pump laser that can effectively increase the maximum output power of the cesium laser. We simultaneously monitored the absorption spectrum of cesium and the laser output power, and the frequency of pump laser was locked at the center of the $D_2$ absorption line of the cesium atom to obtain an effective gain enhancement. Using this scheme, we have achieved output power increase of ~0.1 W compared to when frequency locking was not applied. Furthermore, by optimizing the temperature of the cesium cell and the reflectivity of the output coupler, we successfully achieved an output power of 1.4 W using the pump power of 2.9 W, providing a slope efficiency of 61.5% and optical-to-optical efficiency of 49%.

상용 흡수식 냉동기에서 LiBr 수용액 유량변화에 따른 영향 (Effect of LiBr solution flow rates in commercial absorption chiller)

  • 최승학;정봉철;남임우;정종수;진성민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.292-297
    • /
    • 2001
  • This paper discusses the effect of varying LiBr solution circuits flow rates for a direct fired double effect commercial absorption chiller in the parallel flow configuration. The effects of solution flow rates have been investigated for generator, condenser, solution heat exchanger, absorber and evaporator. According to the result of this work, it was found that sensible heat rate of generator increases and refrigerant vapor generated in that decreases when inlet solution flow rate of that increases. As solution flow rate of absorber increases, the degree of superheat increases because of decreasing solution heat exchanger efficiency. The flashing vapor at the top of absorber increases in proportion to the degree of superheat whileas decreases cooling capacity inversely.

  • PDF