• 제목/요약/키워드: Vapor Compression Refrigerator

검색결과 10건 처리시간 0.022초

증기 압축식 냉동기의 비가역성 분석 (Analysis of the Irreversibilities of a Vapor Compression Type Refrigerator)

  • 신기열;정평석;김수연;이상천
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.30-41
    • /
    • 1995
  • The present paper investigated irreversibilities and energy flow of a vapor compression refrigerator. The entropy generation and the available energy dissipation in components of the system were analyzed by using experimental data. It was shown that the dissipated available energy in the compressor including electric motor was much more than those in other components. The effects of the pressure drop and heat loss on irreversibilities in the condenser and the evaporator were small in comparison with heat transfer.

  • PDF

공진특성을 고려한 냉동/공조용 횡자속 선형압축기의 설계 (The Design of a Linear Compressor Based on the Resonance Characteristics for the Air Conditioner)

  • 홍용주;박성제;김효봉
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.39-46
    • /
    • 2004
  • The compressors in the air conditioner have the role of the pressurization and circulation of the refrigerant. The hermetic reciprocating compressors driven by rotary motor have been used for the air conditioner. The linear compressor has very simple structure and enhancement in the efficiency in comparison to that of conventional reciprocating compressor. The linear compressors are widely used for the small cryogenic refrigerator (below 1 kW), such as the Stirling refrigerator and pulse tube refrigerator. In the cryogenic application, the pressure ratio of the linear compressor is below 1.5, but the linear compressor for the air conditioner should overcome the high pressure ratio and the large pressure difference between the each sides of the piston. The resonance characteristics of the linear compressor has the significant impacts on the power consumption. To minimize the power consumption, the linear compressor should be operated at the resonance point. In the resonance characteristics, the role of the mechanical and gas spring should be considered. In present study, the cycle of the analysis of the vapor compression refrigeration cycle with the different refrigerants (R134a, R4l0a, R600a) and the designs of the linear compressor are performed. The effects of the stiffness of the mechanical spring on the electromagnetic forces would be discussed. Finally, the results show the design specification of the linear compressor for the air conditioner.

  • PDF

냉매분사식 팽창장치를 적용한 냉동기의 특성에 관한 연구 (A Study on the Characteristics of the Refrigerator Using a Refrigerant Injection Type Expansion Device)

  • 조병옥
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.925-931
    • /
    • 2000
  • Refrigerating ability of vapor compression refrigerator is decided by the harmonic work of it's components such as compressor, condenser, evaporator, expansion device, and so on. In this study, choosing refrigerant injectors as a new one of expansion device, temperature change of the cold room, ice freezing ability, and power consumption on flowrate of injector and refrigerant charging condition are evaluated experimentally. As the results of this study, it is verified that the spray injection type refrigeration system has some merits according to the flowrate and spray pattern of injector and charging quantum of refrigerant. And there are some design factors such as spray pattern and shape of spray chamber to utilize and fabricate this refrigerant injection type refrigerator.

  • PDF

냉동기 팽창장치로서 인젝터 사용의 적합성에 관한 연구 (Study on the Adaptiveness of Using an Injector As an Expansion Device of Refrigerator)

  • 조병옥
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.1-8
    • /
    • 2000
  • Spray as a liquid atomization technique has wide applications of combustion, painting, chemical, medical and agricultural purpose, and so on. Capillary tubes and expansion valves, as an expansion device of vapor compression type refrigerators, has been used from the early time. But there are some problems in practice, the former can't control refrigerant flowrate exactly and the later most of imported are expensive relatively and has some difficulties to install. Choosing an injector as a new concept of expansion device of refrigerator in this study to improve such troubles of the coming expansion device, the refrigerant spray behavior and refrigeration characteristics are evaluated experimentally. It is verified that the injector with a good function of refrigerant atomization plays a desirable role of refrigerant expansion in the actual refrigeration cycle.

  • PDF

공기분사식 제상장치 개발에 관한 실험적 연구 (Experimental Study for Development of Air Eject Defrost Equipment)

  • 한인근;김창영;김재돌;윤정인
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

태양열을 이용한 흡수식 냉방시스템의 시뮬레이션과 운전조건의 검토 (Simulation of Solar/Absorption Cooling Hybrid System and Examination of Its Operating Condition)

  • 허재영;이상용
    • 대한설비공학회지:설비저널
    • /
    • 제14권1호
    • /
    • pp.1-11
    • /
    • 1985
  • Solar/absorption cooling system was analyzed and its operating condition was examined. For the system, the optimum size of absorption refrigerator and collector area should be determined. As the temperature of water supplied to the generator increases, the collector efficiency decreases whereas the coefficient of performance of absorption refrigerator increases up to a certain point, and vice versa for decreasing of the temperature of water supplied to the generator . Thus if the reeling load is given, the appropriate operating condition can be determined between the two opposing trends by simulation program. As an example of the simulation, the case of Jejudo province was studied. Under the conditions (such as weather data and prices of components, etc.) given en the sample calculation, the result shows that the optimum temperature of water supplied to the generator turned out to be $80.3^{\circ}C$, and still shows a large economical disadvantage in present stage compared to the case of conventional vapor compression cooling/heating combined heat pump system.

  • PDF

냉동기 펌프다운 운전성능에 관한 연구 (A Study on Pump Down Operation Performance of Refrigerator)

  • 김철수;정한식;정효민
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.964-970
    • /
    • 2006
  • Vapor compression refrigerators have much critical variables such as the controls of temperature and pressure switches, control durations and operating hours of electronic valves. This study compares and analyzes the data which is obtained from system controlling of the evaporation temperatures which are generally used in automatic pump down operating systems. Through this study, the automatic evaporation control operation system will be more ideal for the system to keep the proper temperature distribution depending on the purpose of evaporation side. The automatic pump down control operation is more appropriate for the system to aim at the effective use of evaporation side without using the temperature difference. And this test will be proved that the changes at the low pressure side didn't have significant impacts on the high pressure side.

운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성 (Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions)

  • 백승문;손창효;허정호;최인수;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1021-1026
    • /
    • 2014
  • 본 논문에서는 hot-gas를 이용한 다양한 바이패스 제어 방식 중에서 증발기 흡입부 방식에 대해 각각의 성능에 영향을 미치는 외기온도, 출수온도, 과열 및 과냉도 등에 대해서 알아보았다. 그 주요 결과를 요약하면 다음과 같다. 우선, 증발기 흡입부로 hot-gas를 바이패스 하였을 경우에 냉동장치의 성능은 외기온도, 출수온도, 과열 및 과냉도 등에 영향을 받는 것을 알 수 있었다. 따라서 이러한 변수에 대한 최적화를 통해 본 냉동장치의 기초 설계 자료를 제공할 수 있다. 그리고 증발기 흡입부 hot-gas 바이패스 방식의 운전특성을 고찰하여 본 논문에서 제안하는 냉동장치에 대한 적용 가능성을 확인할 수 있었다.

부하변화에 따른 hot-gas 바이패스 방식별 성능 비교 (Performance Comparison of Hot-gas Bypass Types with the Variation of Refrigeration Load)

  • 백승문;윤정인;손창효;허정호
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.48-54
    • /
    • 2014
  • In this paper, three refrigeration systems bypassing hot-gas to compressor outlet, compressor and condenser outlet and evaporator inlet are theoretically compared to offer basic design data for performance depending on cooling load using a HYSYS program. The main results are summarized as follows : First, the COP of third system is the highest. Next, the COP of second system is higher than first one. And, the temperature of compressor inlet of third system is constant for all cooling load. Compared to first and second system, the compressor inlet temperature of the first system is higher than second one for all cooling loads. From the above results, third system, which is bypassing hot-gas to evaporator inlet, is more advantageous when considering the precise temperature control and excellent performance of oil and water cooler of industrial machine.

비단열 모세관 접합방법이 증기압축식 냉동사이클 성능에 미치는 영향 해석 (Analysis of Vapor Compression Refrigeration Cycle Performance Depending on Different Joining Method of Non-adiabatic Capillary Tube)

  • 이대용;박상구;김현정;정지환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권8호
    • /
    • pp.1144-1151
    • /
    • 2009
  • 냉동기는 비단열모세관을 채택하여 사용함으로써 사이클의 효율을 향상시킬 수 있다. 비단열모세관은 모세관과 흡입관을 접합함으로써 둘 사이에 열전달이 일어날 수 있도록 한 장치로서 SLHX 라고 부른다. 두 관을 접합하는 방법은 다양하며 이는 사이클의 성능에 영향을 미칠 수 있다. 본 연구에서는 가장 널리 사용되는 두 가지 접합방법이 냉동사이클에 미치는 영향을 해석하였다. 실험결과 용접형 SLHX의 열저항이 테이프형 SLHX의 열저항 보다 크게 작은 것으로 나타났다. 이를 이용한 사이클해석 결과 용접형 SLHX는 COP 와 냉동능력을 5.09%와 14.77% 향상시키고 테이프형 SLHX는 각각 5.05%와 14.75% 향상시켜 둘 사이의 차이는 매우 작은 것으로 나타났다.