• 제목/요약/키워드: Vane test

검색결과 179건 처리시간 0.022초

전치 가이드 베인 배치 및 형상에 따른 보일러 입구 온도분포의 수치해석 연구 (Numerical Simulation of Duct Flow about Shape and Arrangement of Inlet Guide Vane to Increase the Temperature Uniformity)

  • 이수윤;신승원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1172-1177
    • /
    • 2008
  • Diverging channel from gas burner exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW steam supply and power generation system. Three different test geometries have been chosen for the numerical simulation. The existing design for 300 kW HRSG system (CASE B) has been improved by geometry and position changes of inlet guide vanes along with gas velocity entrance angle at the diverging channel inlet (CASE C). Both cases has been compared with the case where hot combustion gas is directly injected without any guide vanes (CASE A). Improved design shows overall uniform velocity and temperature distribution compared to existing design.

  • PDF

Unsteady Pressure Measurement of Fan Stator Vane Using Pressure Sensitive Paint

  • Sakamoto, Kazuyuki;Tsuchiya, Naoki;Yamamoto, Masahiko;Hamano, Yasunori;Fujii, Kozo
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.789-794
    • /
    • 2004
  • The pressure sensitive paint (PSP) technique has been well established in external flow field. However, there are still unresolved issues in internal flow field. This work was focused on the application to unsteady pressure measurement of fan flow field. The PSP measurement system was established and the image processing software was developed. First, the performance of PSP was investigated at the static cell. Then the unsteady PSP measurement was carried out at fan test facility. PSP data images were acquired from the suction and pressure surface of stator vanes. Pressure distributions on the surface of the stator vane were detected non-intrusively. The issues of image acquisition and image processing were clarified through the practical PSP application to fan flow field.

  • PDF

가변 디퓨저를 장착한 원심 압축기 불안정성 연구 (A Study on the Instabilities of the Centrifugal Compressor with Variable Diffuser)

  • 차봉준;임병준;양수석
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1123-1131
    • /
    • 2002
  • An experimental study on the performance and instability development characteristics of a centrifugal compressor equipped with a cambered variable diffuser has been performed with varying diffuser vane angles. The test was conducted at the design speed of 20,800 rpm and the 80% design speed of 16,640 rpm for 5 diffuser angles : 65$^{\circ}$, 70$^{\circ}$, 75$^{\circ}$, 77.5$^{\circ}$, 80$^{\circ}$ The steady performance test results showed that choking mass flow rate decreases and total pressure ratio increases with a narrowed surge margin as the diffuser vane angle increases. Unsteady pressures were measured using high-frequency pressure transducers at the inducer and the diffuser throat to investigate the instability phenomena such as rotating stall and surge inside the compressor. From the unsteady measurements, it is found that the transient process from rotating stall to surge was mainly affected by diffuser angles. The results of the present study can be applied to the instability control of the centrifugal compressors using a variable diffuser.

낮은 증발온도에서 운전되는 가변속 롤러형 베인 압축기의 성능특성에 관한 분석 (Analysis on the performance characteristics of a variable-speed, roller-type vane compressor operating at low evaporating temperature)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.193-204
    • /
    • 1999
  • Performance of a variable-speed, roller-type vane compressor was evaluated at low evaporating temperature. First, an experimental investigation was conducted to examine the performance variation as functions of both outdoor temperature and rotating speed. For this purpose, a typical heat pump was implemented as a test apparatus to measure mass flow rate and power input. Secondly, computational investigations corresponding to the heat pump test conditions were performed to predict compressor performance using ORNL Map-Based compressor model. Results obtained from the heat-pump experiments showed that both mass flow rate and power consumption were sensitively dependent on both evaporating temperature and compressor speed as was predicted from the computational results. From the comparisons of both experimental and computational results, it was well recognized that the ORNL model was subjected to larger error in the accuracy of prediction as outdoor temperature decreased. When the outdoor temperature was above $-5^{\cire}C$, errors of predicted values corresponding to both mass flow rate and power consumption were estimated as $\pm$10% and $\pm$ 15%, respectively. Finally, it is suggested that the ORNL model needs to be re-evaluated if compressor map data tested below $-5^{\cire}C$(in evaporating temperature) are available.

  • PDF

Cone Pressuremeter를 이용한 점성토의 전단 강도 산정 (Determination of Undrained Shear Strength In Clay from Cone Pressuremeter Test)

  • 이장덕
    • 한국지반공학회논문집
    • /
    • 제20권8호
    • /
    • pp.49-58
    • /
    • 2004
  • 콘프레셔미터는 피에조콘 시험과 프레셔미터 시험을 동시에 수행할 수 있는 현장시험기로서 본 연구에서는 국내 점토지반에서 수행한 시험결과를 해석적으로 분석하였다. 콘프레셔미터 결과에 대한 이론적인 해는 흙이 비선형 거동을 하는 경우와 전단변형 중 체적변화가 발생하지 않는 경우에 대하여 해석적인 해가 존재한다. 이러한 해석적인 해로부터 콘프레셔미터의 결과중 하중 재하구간과 제하구간에 대해 Curve Fitting 방법을 사용한 콘프레셔미터 결과의 해석 방법을 제안하였다. 20개소의 현장에서 수행한 콘프레셔미터 결과 중 지반교란의 영향을 적게 받는 제하구간에 대하여 Curve Fitting 방법을 적용하여 점성토의 비배수 전단특성을 구하였다. 이렇게 구한 지반의 비배수 전단강도와 현장 Vane, 일축압축, 삼축압축 시험결과로부터 구한 지반의 비배수 전단강도를 서로 비교하여 콘프레셔미터 시험 결과로부터 Curve Fitting 방법을 통한 점성토 지반의 전단강도 특성파악의 적정성에 대해 평가하였다.

펌프의 저 유량 운전특성에 관한 실험적 연구 (An Experimental Study on the Pump Operating Characteristics with Low Flow Operation)

  • 오광석;신필권;박종호;심우건;조두연
    • 소음진동
    • /
    • 제9권1호
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF

공내재하시험을 이용한 지반정수 평가 (Evaluation of Soil Properties using Pressuremeter Test)

  • 한상연;장서만;전성곤;이종규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.175-182
    • /
    • 2001
  • The PMT test results are compared with other in situ test such as Standard Penetration Test (SPT), Cone Penetration Test (CPT), Field Vane Test (FVT) and the laboratory test in order to investigate the correlationships for the strength parameters obtained from Busan and Incheon areas. Many proposed correlation formulas also make a comparative study and new correlation formulas for domestic soils are introduced. Limit pressure ( $P_1$) could be determined by P-log($\Delta$V/V) and Relative volume Method. PMT for the granular soils showed relatively high correlation with SPT, while CPT has good correlation with PMT for cohesive soil. The predicted undrained shear test ( $S_{u}$) by the PMT test results for Incheon and Busan samples showed low correlativity with proposed equations, therefore, new correlation formulas are proposed for domestic soils.s.

  • PDF

생석회파일에 의한 연약지반개량효과 (The Improvement Effects of Soft Ground by Quick Lime Pile)

  • 천병식;고갑수;장은석;임지섭;이용한
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 춘계학술대회 논문집
    • /
    • pp.383-389
    • /
    • 1999
  • This paper is a study on the improvement effects by quick lime pile through theoretical analysis and in-situ construction test. Effects of strength increase is studied to verify the improvement effects of soft ground arounding quick lime pile. First, engineering characteristics of quick lime and ground was studied, in the second place, laboratory test(consolidation test, triaxial compression test) and in-situ test(portable cone penetration test, vane test) were peformed for verification of strength increase of adjacent ground. Finally, the results of in-situ test were compared with those of theorecal study. From in-situ test results, strength at 28th curing days(6.11-6.55t/㎡) was twice as great as strength before improvement(3.06t/㎡) and was slightly greater than theoretical value(4.95t/㎡).

  • PDF

연약지반에 대한 현장시험 적용에 관한 연구 (A STUDY ON THE APPLICATION OF FIELD TESTS TO WEAK GROUND)

  • 이승래;정한중;김준석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1992년도 가을학술발표회 논문집
    • /
    • pp.145-148
    • /
    • 1992
  • This paper reports the application of field tests to weak ground. In this study, field and laboratory tests were performed in the west seashore of KOREA(Ildo, Sore, Kunsan, Youngam). Applied tests are standard penetration test, cone penetration test, dilatometer test, field vane test, unconsolidated undrained test, oedometer test and other fundametal material properties tests. The results of in-situ test are used to estimate soil types and undrained shear strengths of five clay local deposits. SPT results showed low reliability and FVT war also demonstrated the best field test to weak clayey deposits.

  • PDF

베인과 블레이드 사이의 상대위치 변화에 따른 터빈 블레이드 표면에서의 열/물질전달 특성 (Effect of Relative Position of Vane and Blade on Heat/Mass Transfer Characteristics on Stationary Turbine Blade Surface)

  • 이동호;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.140-150
    • /
    • 2004
  • In this study, the effect of relative position of the blade for the fixed vane has been investigated on blade surface heat transfer. The experiments were conducted in a low speed stationary annular cascade, and heat transfer of blade was examined for six positions within a pitch. Turbine test section has one stage composed of sixteen guide vanes and blades. The chord length of the tested blade is 150 mm and the mean tip clearance of the blade having flat tip is about $2.5\%$ of the blade chord. For the detailed mass transfer measurements on the blade surfaces, a naphthalene sublimation technique was used. The inlet flow Reynolds number is fixed to $1.5{\times}10^5$. Complex heat transfer characteristics are observed on the blade surface due to various flow characteristics, such as separation bubble, relaminarization, transition to turbulence and leakage vortices. The distributions of velocity and turbulence intensity change significantly with the relative position due to the blockage effect of the blade. This causes the variation of heat transfer patterns on the blade surface. The results show that the flow near the leading edge get highly disturbed and deflected toward the either side of the blade when the blade leading edge is positioned close to the trailing edge of the vane. Therefore, separation bubble disappears on the pressure side and overall heat transfer on the relaminarization region is increased. But, due to reduced tip gap flow at the upstream region, the effect of leakage flow on the upstream region of the blade surface is weakened. Thus, the heat transfer characteristics significantly change with the blade positions.

  • PDF