• 제목/요약/키워드: Vane test

검색결과 179건 처리시간 0.024초

부산점토의 Fall Cone Test에 의한 지수 및 강도특성 (Index Properties and Undrained Shear Strength of the Pusan Clays by Fall Cone Test)

  • 정승원;정성교;;곽정민;김무겸
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.391-398
    • /
    • 2000
  • The index properties of cohesive soils play an important role to examine entire tendency of soil properties. Especially, the Atterberg limits have a good correlation with compression and shear strength of cohesive soils. However, these values strongly depend on their testing methods. In this study, for Pusan clays the Atterberg limits were peformed under different conditions; for example, four kinds of specimen preparation, two kinds of testing equipment, and four kinds of estimating method. And a laboratory vane test was peformed to compare the undrained shear strength with that of the fall cone test. As experimental results, the value of liquid limit performed for oven-dried sample, followed in ASTM D4318, underestimated by about 10% compared to those of another three methods, irrespective to the used equipments. But the value of plastic limit was not influenced by sample preparation methods and equipments. The liquid limits by one-point methods(Leroueil et al., 1996; Nagaraj et al., 1981) were agreed well with those of different methods. Finally, the undrained shear strength by laboratory vane test was relatively larger than that of fall cone test, and the relationship between both showed a bad trend.

  • PDF

사면파괴 하부 점토지반 비배수강도의 평가 (Estimation of Undrained Shear Strength of Clay under Failed Slope)

  • 이승현;한진태
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5572-5577
    • /
    • 2012
  • 사면파괴가 발생한 사면의 하부 연약지반에 대한 현장원치시험결과와 실내시험결과 그리고 강도 추정식에 의한 결과를 상호 비교분석해 보았다. 사면 하부연약지반에 대한 콘관입시험결과와 현장베인시험결과의 비교를 통해 결정된 연약지반의 콘계수값은 12였다. 콘관입시험자료로부터 콘계수 추정식을 적용하여 구한 연약지반의 비배수강도는 현장베인시험에 의한 그것보다 보수적인 값을 주었다. 압밀시험결과를 이용한 추정식을 통해 연약지반의 비배수강도를 추정하고 현장베인시험에 의한 비배수강도와 비교해 보았다. 세 가지 방법을 통한 추정결과에 따르면 Jamiolkowsky 방법에 의한 결과가 시험을 통해 구한 결과에 가장 근접하였으며 현장베인시험에 의한 비배수강도에 비해 0.88~1.23 범위의 값을 보였다.

봉다발 유동 내 비틀림 혼합날개 지지격자의 대류열전달 성능 평가 (Evaluation of Convective Heat Transfer Performance of Twist-Vane Spacer Grid in Rod Bundle Flow)

  • 이치영
    • 대한기계학회논문집B
    • /
    • 제40권3호
    • /
    • pp.157-164
    • /
    • 2016
  • 봉다발 유동에서 비틀림 혼합날개 지지격자의 대류열전달 성능을 실험적으로 평가하였다. 시험부는 $4{\times}4$ 정사각 배열의 봉다발로 제작하였고, 모의 봉다발에서 봉 중심 간 거리와 봉 외경의 비는 ~1.35이다. 대류열전달 성능 평가를 위해 혼합날개 지지격자 하류에서 봉 벽면 온도의 원주방향 및 축방향 분포를 측정하였다. 원주방향의 경우, 지지격자 하류에서 비틀림 혼합날개 끝이 향하는 벽면의 온도가 가장 낮게 나타났는데 이는 비틀림 혼합날개에 의해 왜곡된 유동 때문으로 판단된다. 반면, 축방향의 경우, 혼합날개 지지격자 근처에서 벽면의 온도가 크게 낮아졌는데, 이는 비틀림 혼합날개에 의해 대류열전달이 향상됨을 의미한다. 비틀림 혼합날개 지지격자에 의해 대류열전달 성능은 지지격자 상류에 비해 지지격자 근처 하류에서 ~35 % 향상되었고, 실험데이터를 기반으로 비틀림 혼합날개 지지격자에 대한 열전달 성능 예측 상관식을 제안하였다.

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

  • Tamaki, Hideaki;Unno, Masaru
    • International Journal of Fluid Machinery and Systems
    • /
    • 제1권1호
    • /
    • pp.47-56
    • /
    • 2008
  • The flow behind the variable area nozzle which corresponds to the flow at the leading edge of the impeller was measured with a 3-hole yaw probe and calculated with CFD. Two nozzle throat-areas were investigated. One is the smallest and the other is the largest opening for the variable nozzle. Test results agreed with the calculated results qualitatively. The leakage flow through the tip clearance of the nozzle vane significantly affected the flow field downstream of the nozzle vane with the smallest opening. However, the effect on leakage flow on the flow field downstream of the nozzle vane with the largest opening was very weak and the effect of wake is dominant.

자동차 PS용 베인펌프의 캠곡선 설계 (Design for Cam Curve of a Oil Hydraulic Vane Pump for Vehicles′ Power Steering System)

  • 정석훈;정재연
    • Tribology and Lubricants
    • /
    • 제20권3호
    • /
    • pp.157-162
    • /
    • 2004
  • The cam curve of a balance type vane pump consists usually of circular arcs and Archimedes' spirals. However, if they are connected directly together, the curve must have a few discontinuous points of the gradients and the motion of the vanes is no longer smooth. Designing data for an oil hydraulic vane pump used in power steering system were obtained by the acquisition of optimum cam profile data which can be available to reduce noises and vibrations through the minimization of cavitation with the improvement of suctional performance. The performance test is carried on the trial manufactures by measuring the volumetric and the mechanical efficiency. And from that result, maintaining the same characteristic as the conventional one in the relief pressure and noise level, the experimental pump discharges 0.7 $\ell$/min and shows nearly 3.5% enhancement in the total efficiency more than the conventional one.

연약지반에 대한 기계식 및 전자식 콘관입시험 비교 연구 (Comparative study of Dutchcone and piezocone test on soft ground)

  • 장병욱;김재현;김동범;윤상묵;원정윤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.237-244
    • /
    • 2002
  • A comparative study of 134 mechanical (Dutch cone) and 9. electronic cone (Piezocone) penetration data from the southern part of Korea has been performed. In general, Dutch cone results may be different from piezocone results due to the difference in structure of the cones. Cone penetrometer test data were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986,1990) Cone factors of Dutch cone and piezocone test have empirically been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

  • PDF

전남 광양지역 연약지반의 피에조콘계수 산정 (Estimation of Soft Ground Piezocone Factors at Gwangyang, Jeonnam)

  • 오동춘;김기범;백승철
    • 한국지반환경공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.59-67
    • /
    • 2019
  • 전남 남해안 지역인 광양항 동측배후단지 연약지반에서 수행한 실내시험, 현장베인시험 및 피에조콘 관입시험 결과를 이용하여 연약지반의 공학적 특성을 규명하고, 피에조콘계수 산정을 위해 최적의 피에조콘 관입시험 심도를 결정하였다. 본 논문에서 이용한 자료는 61개의 실내시험과 226회의 현장베인시험, 피에조콘 관입시험 26개소이다. 실내시험 분석 결과 남해안의 다른 지역에 비해 비중, 함수비, 액성한계 및 소성지수 등의 물리적 특성이 높게 나타나며, 일축압축강도와 비배수전단강도의 역학적 특성은 넓은 범위로 분포하고 비교적 작은 값을 나타냈다. 소성도에 의한 흙 분류 결과 소성이 큰 무기점토(CH)와 소성이 작은 무기점토(CL)로 분류되었으며, Robertson(1990) 분류도표에 의한 흙 분류 결과 대부분 Type 3인 점성토에 해당하였다. 현장베인시험으로 구한 비배수전단강도를 기준으로 경험적 방법에 의해 피에조콘계수를 산정했다. 이를 위해 현장베인시험 측정심도와 비교되는 피에조콘 관입시험의 적정 측정심도 범위를 설정하기 위해 3가지 심도범위로 상관성을 분석한 결과 베인 길이의 5배 범위 측정값의 평균을 사용하는 것이 높은 상관성을 보여준다.

베인에 작용하는 수평응력과 토크를 이용한 모래의 마찰각 측정 (Measurement of Friction Angle of Sand from Horizontal Stress and Torque Acting on Vane)

  • 박성식;김동락;이새벽
    • 대한토목학회논문집
    • /
    • 제38권1호
    • /
    • pp.63-71
    • /
    • 2018
  • 본 연구에서는 베인에 작용하는 수평응력과 토크를 측정한 다음 이를 이용하여 모래의 마찰각을 구하는 연구를 수행하였다. 건조한 낙동강모래를 원통형 셀에 느슨하거나 조밀한 상태로 성형한 다음 상부에서 공기압 실린더로 상재하중(overburden pressure)을 25, 50, 75 또는 100kPa 가하여 베인(직경 5cm, 높이 10cm) 회전 시 주변에 작용하는 수평응력과 토크를 실시간으로 측정하였다. 베인 회전에 따른 최대 토크값은 느슨한 모래는 3.5~9.5Nm, 조밀한 모래는 7.4-17.6Nm 사이로 상재하중이 증가할수록 최대 토크값도 증가하였다. 조밀한 정도에 관계없이 $14-20^{\circ}$ 회전 시 최대 토크값에 도달하였으며, 베인날과 토압계의 초기 위치에 따른 최대값의 차이는 나지 않았다. 상재하중에 따라 베인에 작용하는 초기 수평응력비($K_0$)는 평균 0.33-0.35 사이이며, 베인 회전에 따라 수평응력이 전반적으로 증가하다가 모래 입자가 교란되면서 다시 감소하는 경향을 보였다. 실시간으로 측정된 수평응력과 토크를 이용하여 계산된 마찰각은 상재하중이 증가함에 따라 감소하는 경향을 보였으며, 느슨한 모래는 직접전단시험 결과와 유사한 마찰각을 보였다. 하지만, 조밀한 모래의 마찰각은 다소 과대평가하는 경향을 보였다.

Vane Test에 관한 토의

  • 채영수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1998년도 지반조사위원회 여름 학술세미나
    • /
    • pp.119-124
    • /
    • 1998
  • PDF

베인 전단시험기를 이용한 낙동강모래의 마찰각에 관한 연구 (Vane Shear Test on Nakdong River Sand)

  • 박성식;쪼우안;김동락
    • 대한토목학회논문집
    • /
    • 제36권3호
    • /
    • pp.463-470
    • /
    • 2016
  • 베인 전단시험은 흙의 교란을 최소화하면서 점성토의 비배수전단강도를 측정하는 간단한 시험이다. 하지만, 본 논문에서는 베인 전단시험기를 이용하여 모래의 배수전단강도를 측정하기 위한 연구를 수행하였다. 건조한 낙동강모래를 원통형 셀에 느슨하거나 조밀한 상태로 재성형한 다음 상부에서 공기압 실린더로 상재하중(overburden pressure)을 25, 50, 75 또는 100kPa 가한 다음 베인(직경 5cm, 높이 10cm)을 회전시켜 회전 모멘트인 최대 토크를 구하였다. 베인 회전 모멘트와 모래 입자의 마찰 저항 모멘트가 평형을 이룬다는 조건을 이용하여 모래의 마찰각을 구하였다. 점토의 경우에는 베인 전단 시 원통형의 회전체 상하면과 주면에 균일한 비배수전단강도인 점착력이 작용한다고 가정하지만, 사질토를 사용한 본 연구에서는 베인 날 주면에서 형성되는 파괴면을 원기둥, 팔각기둥 또는 사각기둥 형태로 가정하여 각각에 대한 마찰각을 계산하였다. 한편, 본 연구에서 제안한 방법을 검증하기 위해 동일한 모래로 직접전단시험을 실시하여 마찰각을 구하였다. 베인 전단시험으로부터 구한 마찰각은 가정한 파괴면의 형태에 따라 느슨한 모래의 경우 24-42도, 조밀한 모래는 33-53도 사이이며, 직접전단시험 결과는 이 범위 내에 속하였다.