• Title/Summary/Keyword: Valveless

Search Result 39, Processing Time 0.031 seconds

Traumatic Asphyxia -A Case Report- (외상성 질식 증후군 -1례 보고-)

  • 신화균
    • Journal of Chest Surgery
    • /
    • v.27 no.4
    • /
    • pp.335-338
    • /
    • 1994
  • Traumatic asphyxia is a distinctive clinical syndrome characterized by cervicofacial cyanosis and edema, bilateral subconjuctival hemorrhage, and multiple petechiae of the face, neck, and upper part of the chest after a severe compressive crush injury of the thorax or of the upper part of the abdomen.The pathophysiologic mechanism of traumatic asphyxia is reflux of blood from the heart retrograde through the valveless superior vena cava and the great veins of the head and neck by severe compression of the thorax or the abdomen.We experienced one case of the traumatic asphyxia, and its clinical features are discussed.

  • PDF

Three Dimensional Electro-Fluid-Structural Interaction Simulation for Pumping Performance Evaluation of a Valveless Micropump (무밸브 마이크로 펌프의 성능평가를 위한 3차원 전기-유체-구조 상호작용 해석)

  • Pham, My;Phan, Van Phuoc;Han, Cheol-Heui;Goo, Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.744-750
    • /
    • 2009
  • In this study, the pumping performance of a piezoelectric valveless micropump is simulated. The micropump, which was developed in the previous work, is composed of a four-layer lightweight piezocomposite actuator, a polydimethylsiloxane (PDMS) pump chamber, and two diffusers. The piezoelectric domain, the fluid domain and the structural domain are coupled in the three-dimensional simulation. We used ANSYS for the piezoelectric and structural domains and ANSYS CFX for the fluid domain. The effects of driven frequency on the flow rate have been investigated by simulating the flow characteristics for 10 Hz and 40 Hz driven frequencies. The flow rates with respect to driven frequencies up to 300 Hz have been calculated.

Design and Characteristics of valveless micro-pump for small liquid delivery (미소유체 밸브리스 압전펌프의 설계 및 특성)

  • Lim, Jong-Nam;Oh, Jin-Heon;Lim, Kee-Joe;Kim, Hyun-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1275_1276
    • /
    • 2009
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. Using the flexural vibration mode of PZT bar, a piezopump is successfully made. The PZT bar is polarized with thickness direction. The proposed structure for the piezo-pump consists of an input and an output port, piezoelectric ceramic actuator, actuator support, diaphragm. The traveling flexural wave along the bar is obtained by dividing two standing waves which are temporally and spatially phase shifted by 90 degrees from each other. Fluid is drawn into a forming chamber, eventually the forming chamber closes trapping the fluid therein.

  • PDF

Design of valveless type peristaltic micro-pump (밸브레스 연동(連動) 압전펌프의 설계 및 특성)

  • Oh, Jin-Heon;Jeong, Eui-Hwan;Lim, Jong-Nam;Lim, Kee-Joe;Song, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1301_1302
    • /
    • 2009
  • Recently, there has been increased incessantly an interest in research area on micro-fluidic pump for electronic and biological applications. The proposed pump takes an unobtrusive operation into the simple displacing mechanism using peristaltic traveling waves without the physical moving valves. And, this piezopump makes up a panel type design. The ATILA simulation was performed to estimate the operating frequency of the vibrating wave mode, to optimize the design conditions of piezopump such as structure, elastic body material, piezoelectric ceramics, and to analyze the distribution of vibration displacement. The best measured value of the pumping rate is about $118{\mu}l$/min under the following parameters : 4-wave mode, 50kHz operating frequency, $200V_p$.

  • PDF

Vibration analysis of valveless Type Piezoelectric micro-pump by using ATILA (ATILA를 이용한 진행파 회전형 밸브리스 압전펌프의 진동 해석)

  • Lim, Jong-Nam;Oh, Jin-Heon;Park, Cheol-Hyun;Lim, Kee-Joe;Kim, Hyun-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.215-216
    • /
    • 2008
  • Using the extensional vibration mode of PZT ring, a piezopump is successfully made. The PZT ring is polarized with thickness direction. The traveling extensional wave along the circumference of the ring is obtained by dividing two standing waves which are temporally and spatially phase shifted by 90 degrees from each other. The proposed piezopump is consisted of coaxial cylindrical shells that are bonded piezoelectric ceramic ring.

  • PDF

A Study on the Performance Characteristics of a New Bi-directional Micropump Using Piezoelectric Actuator (압전식 구동기를 이용한 양방향 마이크로 펌프의 성능에 관한 연구)

  • Choi Jong-Won;Yoon Jae-Sung;Kim Min-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.350-357
    • /
    • 2006
  • A new valveless micropump for bi-directional application has been developed and tested. The micropump was fabricated on silicon and glass substrates by micromachining process. The micropump in this study consists of a membrane actuator, a pumping chamber, fluidic channels and two piezoelectric ceramic films. The channels and pumping chamber were etched on a glass wafer and the membrane was made on a silion wafer which is actuated by a piezoelectric ceramic (PZT) film. The geometry of the micropump was optimized by numerical analysis and the performance of the micropump was investigated by the experiments. The maximum flow rate was $323{\mu}L/min$ and the maximum back pressure was 294 Pa when the membrane actuator of $10{\times}10mm^2$ was driven at 130 Hz and 385 V.

Micro Tube Pump for an Implantable Drug Infusion Device (이식형 약물 주입 장치용 마이크로 튜브 펌프)

  • Bach, Du-Jin;Park, Jun-Woo;Lee, Duck-Hee;Lee, Chul-Han;Hong, So-Young;Jo, Yung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • This paper proposes a tube pump composed of small-sized cams and followers for an implantable intrathecal drug infusion device. Each followers is driven by a cam and liquid is discharged by a sequential reciprocal motion of the followers. The advantage of this structure is that it allows the pump to be clean and valveless. To design a small-sized, low power pump some analysis were performed to determine the design parameters of the cam, follower and the tube. To verify the feasibility of the experiment, a prototype was manufactured and its operating characteristics were investigated. Experimental results were in accordance with the expected results obtained from analysis.

Fabrication of a Thermopneumatic Valveless Micropump with Multi-Stacked PDMS Layers

  • Jeong, Ok-Chan;Jeong, Dae-Jung;Yang, Sang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.137-141
    • /
    • 2004
  • In this paper, a thermopneumatic PMDS (polydimethlysiloxane) micropump with nozzle/diffuser elements is presented. The micropump is composed of nozzle/diffuser elements as dynamic valves, an actuator consisting of a circular PDMS diaphragm and a Cr/Au heater on a glass substrate. Four PDMS layers are used for fabrication of an actuator chamber, actuator diaphragm by a spin coating process, spacer layer, and nozzle/diffuser by the SU-8 molding process. The radius and thickness of the actuator diaphragm is 2 mm and 30 ${\mu}{\textrm}{m}$, respectively. The length and the conical angle of the nozzle/diffuser elements are 3.5 mm and 20$^{\circ}$, respectively. The actuator diaphragm is driven by the air cavity pressure variation caused by ohmic heating and natural cooling. The flow rate of the micropump in the frequency domain is measured for various duty cycles of the square wave input voltage. When the square wave input voltage of 5 V DC is applied to the heater, the maximum flow rate of the micropump is 44.6 ${mu}ell$/min at 100 Hz with a duty ratio of 80% under the zero pressure difference.

Vibration analysis of characteristics and valveless Type Piezoelectric micro-pump (VALVELSS 압전펌프 진동 해석 및 특성)

  • Lim, Jong-Nam;Oh, Jin-Heon;Lim, Kee-Joe;Kim, Hyun-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.185-185
    • /
    • 2009
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. Using the flexural vibration mode of PZT bar, a piezopump is successfully made. The PZT bar is polarized with thickness direction. The proposed structure for the piezo-pump consists of an input and an output port, piezoelectric ceramic actuator, actuator support, diaphragm. The traveling flexural wave along the bar is obtained by dividing two standing waves which are temporally and spatially phase shifted by 90 degrees from each other. Fluid is drawn into a forming chamber, eventually the forming chamber closes trapping the fluid therein. The finite elements analysis on the proposed pump model is carried out to verify its operation principle and design by the commercial FEM software. Components of piezopump were made, assembled, and tested to validate the concepts of the proposed pump and confirm the simulation results. The performance of the proposed piezopump the highest pressure level of 83.4kHz.

  • PDF