• Title/Summary/Keyword: Valve-pipe System

Search Result 166, Processing Time 0.024 seconds

Crack Effects on Dynamic Stability of Elastically Restrained Valve-pipe System (탄성 지지된 밸브 배관계의 안정성에 미치는 크랙의 영향)

  • Hur, Kwan-Do;Son, In-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.79-86
    • /
    • 2011
  • The dynamic instability and natural frequency of elastically restrained pipe conveying fluid with the attached mass and crack are investigated. The pipe system with a crack is modeled by using extended Hamilton's Principle with consideration of bending energy. The crack on the pipe system is represented by a local flexibility matrix and two undamaged beam segments are connected. In this paper, the influence of attached mass, its position and crack on the dynamic stability of a elastically restrained pipe system is presented. Also, the critical flow velocity for the flutter and divergence due to the variation in the position and stiffness of supported spring is studied. Finally, the critical flow velocities and stability maps of the pipe conveying fluid with the attached mass are obtained by the changing parameters.

The Study of Water Hammer in Polybutylene Double Piping System (폴리부틸렌 이중관에서의 워터 햄머 현상에 관한 연구)

  • Kim, Yong-Bong;Yang, Chan-Mo;Lee, Yong-Hwa
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.511-516
    • /
    • 2005
  • This study is to investigate the pressure wave characteristics and the maximum pressure rise generated by instantaneous valve closure at the end of the straightening polybutylene double piping system with header. Experiments were conducted under the following conditions: initial pressure $1{\sim}5$ bar, flow velocity $0.5{\sim}3.0$ m/s and water temperature $25^{\circ}C$.

  • PDF

The Study of Water Hammer in Polybutylene Double Piping System (폴리부틸렌 이중관에서의 수격 현상에 관한 연구)

  • Lee, Yong-Hwa
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.380-385
    • /
    • 2009
  • This study is to investigate the pressure wave characteristics and the maximum pressure rise generated by instantaneous valve closure at the end of the straightening polybutylene double piping system with header. Experiments were conducted under the following conditions: initial pressure $0.1{\sim}0.5$ MFa, flow velocity $0.5{\sim}3.0$ m/s and water temperature $25^{\circ}C$.

Analysis of a transient vibration response caused by Water Hammer in a pipe-line system (수격 현상에 의한 파이프의 과도진동응답 해석)

  • 조성문;서영수;정의봉;정호경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.119-124
    • /
    • 2004
  • A water hammer mostly comes out when a valve fixed at the downstream end of the pipe-line system is rapidly closed or opened. A simple phenomenon of water hammer is often caused around us, and this phenomenon imperils the pipe systems occasionally. In this paper, we confirmed the phenomenon of water hammer by an experiment and forecasted a change of pressure in the pipe-line system by a numerical method. Also a vibration response, which is caused by water hammer, of the pipe-line system confirmed by an experiment and analyzed by a numerical method.

  • PDF

Preliminary Review of On-Site Clamping Repair Technology for Welding Part Leakage of Safety Related Valve in the Nuclear Power Plant (원전용 안전등급 밸브의 용접부 누설 클램핑 현장보수 기술 검토)

  • Ki Hong Kim;Ki Su Kim;Hwan Seok Jung;Moo Kyung Jang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.1
    • /
    • pp.52-59
    • /
    • 2023
  • The welding part of the valve needs immediate action when leakage occurs due to cracks or damage. In order to repair leakage of the welding part, the valve must be separated from the pipe or replaced with a new valve. However, it is difficult to remove the valve while operating the power plant. This study presents a method to remove leakage by precisely processing the gap between the clamp and the incision part within 0.1mm while installed in the pipe system. If the external leakage is removed using a clamp on the welding part without removing the valve during operation, the time and cost required for maintenance can be reduced.

An automated control system for concrete temperature development in construction

  • Qiang, Sheng;Leng, Xue-jun;Wang, Xiang-rong;Zhang, Jing-tao;Hua, Xia
    • Computers and Concrete
    • /
    • v.24 no.5
    • /
    • pp.437-444
    • /
    • 2019
  • PLC and its expansion module, electric ball valve and cooling pipe, electric heating steel plate and various components of the system, which is used to control test and process data. By automatically adjusting the opening of the valve, the system makes the top temperature and cooling speed develop along the ideal temperature diachronic curve. Moreover, the system enables the temperature difference between inside and surface of test block limited in a given range by automatically controlling the surface board heating. The method of physical simulation test by sandbox with built-in cooling water pipe and heating rod is adopted. On the premise of a given standard value, the operation of the system is checked under different working conditions. Further, an extension of this system is proposed, which enables its application to obtain some thermal parameters when cooperating with numerical simulation.

Optimization Design of a Gas Valve for a LPG Cylinder Using a Taguchi's Experimental Method (다구찌 실험법을 이용한 액화석유가스 용기용 밸브의 최적설계에 관한 연구)

  • Kim, Chung-Kyun;Oh, Kyoung-Seok
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.23-28
    • /
    • 2006
  • This paper presents the strength safety and the weight reduction analysis of nine gas valve models for a LPG cylinder using a finite element analysis program, MARC and Taguchi's experimental method. The maximum Von Mises stress of a gas valve body represents a safety of a brass valve structure for the given gas pressure of $91kg/cm^2$, which considered a safety factor of a LPG gas cylinder. The weight reduction analysis is very important for reducing a gas flow friction loss and a manufacturing cost as a design parameter. The calculated results present an design model 9 as an optimized design data with 10mm radius of a lower part gas flow pipe A, 6mm radius of an upper part gas flow pipe B and a connecting length 2 mm of tapered pipe D between lower and upper pipes.

  • PDF

A Study on Fluid Flow in the Intake Manifold for an Engine (엔진 흡기관내의 유체유동에 관한 연구)

  • 성낙원;이응석;강건용;엄종호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.295-307
    • /
    • 1988
  • In order to predict performance of the intake manifold, which is dependent on the length and diameter of a resonance pipe, the Fluid Dynamic Model for 4-cylinder diesel engine is developed using two step Lax-Wendroff method to solve the governing equations of air flow in the intake system. Boundary conditions at the intake valve, branch at the manifolds, and pipe end are also modeled. The results of the models are compared with the experimental results of a motored engine. The model is capable of predicting the real phenomena satisfactorily with reasonable computing time.

Effect of Differential Pressure on the Performance of Motor Operated Flexible Wedge Gate Valve (차압이 모터구동 Flexible Wedge형 게이트밸브의 성능에 미치는 영향)

  • Kim, Dae-Woong;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.151-158
    • /
    • 2007
  • The mechanism of power transmission from motor torque to stem thrust and the operation characteristic of each stroke position are analyzed using the diagnostic signal, and effects of differential pressure on the performance of motor operated flexible wedge gate valve are investigated. Test facility consists of 76 mm motor operated valve(flexible wedge type), pump and pipe system. Static and dynamic test are performed separately, and two differential pressure conditions are applied in the dynamic test. To evaluate the performance of valve, test signals for the torque, thrust, current, voltage and stroke length are acquired by using UDS which is diagnosis device for motor operated valve, and each diagnostic signal is analyzed and compared. The characteristic of valve performance factors such as stem factor, rate of loading, valve factor, are evaluated, and these factors are found to be severely influenced by the fluid differential pressure.

Study of Thermal Stratification into Leaking Flow in the Nuclear Power Plant, Emergency Core Coolant System (원자로 비상 냉각재 누설에 의한 열성층의 비정상 특성에 관한 연구)

  • Han Seong-Min;Choi Yong-Don;Park Min-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.202-210
    • /
    • 2006
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can be occurred due to coolant leaking in the check valve. The thermal stratification produces excessive thormal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, when the turbulence penetration occurs in the branch pipe, the maximum temperature differences of fluid at the pipe cross-sections of the T-branch with thermal stratification are examine.