• 제목/요약/키워드: Valve surgery

검색결과 1,199건 처리시간 0.025초

Aortic Valve Sparing Operations: A Review

  • David, Tirone E.
    • Journal of Chest Surgery
    • /
    • 제45권4호
    • /
    • pp.205-212
    • /
    • 2012
  • Aortic valve sparing operations were developed to preserve the native aortic valve during surgery for aortic root aneurysm as well as surgery for ascending aortic aneurysms with associated aortic insufficiency. There are basically two types of aortic valve sparing oprations: remodeling of the aortic root and reimplantation of the aortic valve. These operations have been performed for over two decades and the clinical outcomes have been excellent in experienced hands. Although remodeling of the aortic root is physiologically superior to reimplantation of the aortic valve, long-term follow-up suggests that the latter is associated with lower risk of developing aortic insufficiency. Failure of remodeling of the aortic root is often due to dilatation of the aortic annulus. Thus, this type of aortic valve sparing should be reserved for older patients with ascending aortic aneurysm and normal aortic annulus whereas reimplantation of the aortic valve is more appropriate for young patients with inherited disorders that cause aortic root aneurysms. This article summarizes the published experience with these two operations. They are no longer experimental procedures and should be part of the surgical armamentarium to treat patients with aortic root aneurysm and ascending aortic aneurysms with associated aortic insufficiency.

Postoperative Outcomes of Mitral Valve Repair for Mitral Restenosis after Percutaneous Balloon Mitral Valvotomy

  • Lee, Ji Seong;Chee, Hyun Keun;Kim, Jun Seok;Song, Myong Gun;Park, Jae Bum;Shin, Je Kyoun
    • Journal of Chest Surgery
    • /
    • 제48권5호
    • /
    • pp.328-334
    • /
    • 2015
  • Background: There have been a number of studies on mitral valve replacement and repeated percutaneous mitral balloon valvotomy for mitral valve restenosis after percutaneous mitral balloon valvotomy. However, studies on mitral valve repair for these patients are rare. In this study, we analyzed postoperative outcomes of mitral valve repair for mitral valve restenosis after percutaneous mitral balloon valvotomy. Methods: In this study, we assessed 15 patients (mean age, $47.7{\pm}9.7years$; 11 female and 4 male) who underwent mitral valve repair between August 2008 and March 2013 for symptomatic mitral valve restenosis after percutaneous mitral balloon valvotomy. The mean interval between the initial percutaneous mitral balloon valvotomy and the mitral valve repair was $13.5{\pm}7years$. The mean preoperative Wilkins score was $9.4{\pm}2.6$. Results: The mean mitral valve area obtained using planimetry increased from $1.16{\pm}0.16cm^2$ to $1.62{\pm}0.34cm^2$ (p=0.0001). The mean pressure half time obtained using Doppler ultrasound decreased from $202.4{\pm}58.6ms$ to $152{\pm}50.2ms$ (p=0.0001). The mean pressure gradient obtained using Doppler ultrasound decreased from $9.4{\pm}4.0mmHg$ to $5.8{\pm}1.5mmHg$ (p=0.0021). There were no early or late deaths. Thromboembolic events or infective endocarditis did not occur. Reoperations such as mitral valve repair or mitral valve replacement were not performed during the follow-up period ($39{\pm}16months$). The 5-year event-free survival was 56.16% (95% confidence interval, 47.467-64.866). Conclusion: On the basis of these results, we could not conclude that mitral valve repair could be an alternative for patients with mitral valve restenosis after percutaneous balloon mitral valvotomy. However, some patients presented with results similar to those of mitral valve replacement. Further studies including more patients with long-term follow-up are necessary to determine the possibility of this application of mitral valve repair.

Traumatic Tricuspid Regurgitation Treated by the Minimally Invasive Double Orifice Technique

  • Lee, Chan Kyu;Jang, Jae Hoon;Lee, Na Hyeon;Song, Seunghwan
    • Journal of Chest Surgery
    • /
    • 제54권1호
    • /
    • pp.68-71
    • /
    • 2021
  • A 37-year-old man was transferred to our level I trauma center after a road traffic accident, presenting with right acetabular fracture, multiple rib fractures, epidural hemorrhage, and liver contusion. Severe traumatic tricuspid regurgitation was also discovered during the work-up for surgery. Our initial attempt at acetabular surgery failed when the patient experienced near cardiac arrest during anesthetic induction. It was hence decided that tricuspid valve repair should precede orthopedic surgery. Minimally invasive tricuspid valve repair using the double orifice technique was successfully performed. Subsequently, acetabular surgery was performed and he was discharged 35 days post-trauma without any complications.

선천성 사엽성 반월형 판막 - 1예 보고 - (Congenital Quadricuspid Semilunar Valve - A case report -)

  • 서민범;서홍주
    • Journal of Chest Surgery
    • /
    • 제42권3호
    • /
    • pp.361-363
    • /
    • 2009
  • 호흡곤란을 주소로 내원한 17세 환자가 대동맥 및 폐동맥 사엽성 판막을 보이며 심방중격결손과 폐동맥 판막 협착증이 발전되어 소심막을 이용한 심방중격결손 봉합 및 폐동맥 판막 교련절개술을 시행하였다. 대동맥 판막과 폐동맥 판막이 모두 사엽성 판막을 보이는 경우는 매우 드문 선천성 기형으로 폐동맥 사엽성 판막이 대동맥 사업성 판막보다 9배정도 많다. 본 증례는 Hurwitz and Roberts 분류법상 대동맥판막은 A형, 폐동맥판막은 B형이었으며 대동맥 판막기능은 정상적이었고 폐동맥 판막 협착증을 보였다.

Outcomes of Nonpledgeted Horizontal Mattress Suture Technique for Mitral Valve Replacement

  • Kim, Gun Jik;Lee, Jong Tae;Lee, Young Ok;Cho, Joon Young;Oh, Tak-Hyuk
    • Journal of Chest Surgery
    • /
    • 제47권6호
    • /
    • pp.504-509
    • /
    • 2014
  • Background: Most surgeons favor the pledgeted suture technique for heart valve replacements because they believe it decreases the risk of paravalvular leak (PVL). We hypothesized that the use of nonpledgeted rather than pledgeted sutures during mitral valve replacement (MVR) may decrease the incidence of prosthetic valve endocarditis (PVE) and risk of a major PVL. Methods: We analyzed 263 patients, divided into 175 patients who underwent MVR with nonpledgeted sutures from January 2003 to December 2013 and 88 patients who underwent MVR with pledgeted sutures from January 1995 to December 2001. We compared the occurrence of PVL and PVE between these groups. Results: In patients who underwent MVR with or without tricuspid valve surgery and/or a Maze operation, PVL occurred in 1.1% of the pledgeted group and 2.9% of the nonpledgeted group. The incidence of PVE was 2.9% in the nonpledgeted group and 1.1% in the pledgeted group. No differences were statistically significant. Conclusion: We suggest that a nonpledgeted suture technique can be an alternative to the traditional use of pledgeted sutures in most patients who undergo MVR, with no significant difference in the incidence of PVL.

Trends in Heart Valve Surgery in Korea: A Report from the Heart Valve Surgery Registry Database

  • Choi, Jae Woong;Kim, Joon Bum;Jung, Yoo Jin;Hwang, Ho Young;Kim, Kyung Hwan;Yoo, Jae Suk;Lee, Sak;Lee, Seung Hyun;Sung, Kiick;Je, Hyung Gon;Lim, Mi Hee;Chang, Byung-Chul;Hong, Soon Chang;Lee, Heemoon;Shin, Yoon Cheol;Kim, Jae Hyun;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • 제55권5호
    • /
    • pp.388-396
    • /
    • 2022
  • Background: In this study, we present recent trends in heart valve surgery in Korea through analyses of data from the Korea Heart Valve Surgery Registry (KHVSR). Methods: We enrolled 8,981 patients who were registered in the KHVSR from 2017 to 2020. Yearly trends in patients' baseline characteristics, surgical profiles, and early mortality rates were explored. The observed/expected mortality ratio (O/E ratio), calculated from the actual mortality in the KHVSR and the predicted mortality estimated using the EuroSCORE II, was also analyzed. Results: The proportion of aortic valve surgery significantly increased from 56.8% in 2017 to 60.3% in 2020. The proportion of all combined procedures and minimally invasive surgery significantly increased over the 4-year study period. The operative mortality rate was 2.9% in the entire cohort, while mitral valve repair showed the lowest mortality risk (0.9%). The mortality rates of isolated aortic valve replacement (AVR) significantly decreased from 2.1% in 2017 to 0.8% in 2020 (p=0.016). Overall, the O/E ratio was 0.784 (95% confidence interval [CI], 0.677-0.902) demonstrating significantly lower actual mortality risks than expected based on the EuroSCORE II. In particular, the O/E ratios were as low as 0.364 (95% CI, 0.208-0.591) for isolated AVR. Conclusion: The recent data from the KHVSR showed increasing trends for complex procedures and minimally invasive surgery in heart valve surgery in Korea, and demonstrated remarkably low risks of operative mortality.

Comparable Outcomes of Bicuspid Aortic Valves for Rapid-Deployment Aortic Valve Replacement

  • Somin Im;Kyung Hwan Kim;Suk Ho Sohn;Yoonjin Kang;Ji Seong Kim;Jae Woong Choi
    • Journal of Chest Surgery
    • /
    • 제56권6호
    • /
    • pp.435-444
    • /
    • 2023
  • Background: Edwards Intuity is recognized as a relatively contraindicated bioprosthesis for bicuspid aortic valve disease. This study compared the early echocardiographic and clinical outcomes of rapid-deployment aortic valve replacement for bicuspid versus tricuspid aortic valves. Methods: Of 278 patients who underwent rapid-deployment aortic valve replacement using Intuity at Seoul National University Hospital, 252 patients were enrolled after excluding those with pure aortic regurgitation, prosthetic valve failure, endocarditis, and quadricuspid valves. The bicuspid and tricuspid groups included 147 and 105 patients, respectively. Early outcomes and the incidence of paravalvular leak were compared between the groups. A subgroup analysis compared the outcomes for type 0 versus type 1 or 2 bicuspid valves. Results: The bicuspid group had more male and younger patients. Comorbidities, including diabetes mellitus, hypertension, chronic kidney disease, and coronary artery disease, were less prevalent in the bicuspid group. Early echocardiographic evaluations demonstrated that the incidence of ≥mild paravalvular leak did not differ significantly between the groups (5.5% vs. 1.0% in the bicuspid vs. tricuspid groups, p=0.09), and the early clinical outcomes were also comparable between the groups. In the subgroup analysis between type 0 and type 1 or 2 bicuspid valves, the incidence of mild or greater paravalvular leak (2.4% vs. 6.7% in type 0 vs. type 1 or 2, p=0.34) and clinical outcomes were comparable. Conclusion: Rapid-deployment aortic valve replacement for bicuspid aortic valves demonstrated comparable early echocardiographic and clinical outcomes to those for tricuspid aortic valves, and the outcomes were also satisfactory for type 0 bicuspid aortic valves.

심장판막질환과 동반된 관상동맥질환의 수술 (Cardiac Valve Replacement and Simultaneous Myocardial Revascularization)

  • Reiner, Korfer;Jee, Heng-Ok
    • Journal of Chest Surgery
    • /
    • 제21권1호
    • /
    • pp.164-168
    • /
    • 1988
  • Between November, 1984, and May, 1986, 93 patients underwent combined valvular and coronary artery operation. They were 70 male and 23 female, the age ranging from 29 to 82. From this population 89 patients underwent single valve replacement and 4 patients underwent double valve replacement. Patients with mitral valve disease were in the majority present in the age group between 50 till 70, where as in the group after 60 years, patients with aortic valve disease were dominant. The main indication for aortic valve replacement was aortic stenosis and the indication for mitral valve replacement was equal between mitral stenosis and mitral incompetence, the later was due to papillary dysfunction after myocardial infarction. Dyspnea was a very frequent symptom and it was found in nearly all patients. 28 patients had a previous myocardial infarction and severe left ventricular dysfunction. The grafts were placed prior to valve replacement and periods of myocardial ischemia were kept at a minimum by maintaining coronary perfusion throughout the operation. It is our opinion that simultaneous valve replacement and myocardial revascularization does not increase the risk of cardiac valve replacement substantially.

  • PDF

Bjork-Shiley 기계판막의 임상적 연구 (Clinical Analysis of Bjork-Shiley Mechanical Valve Replacement)

  • 김병열
    • Journal of Chest Surgery
    • /
    • 제22권3호
    • /
    • pp.393-401
    • /
    • 1989
  • Between Dec. 1984, and May, 1988,96 prostheses were implanted in 80 patients at Dept. of Thoracic k Cardiovascular Surgery of National Medical Center. 43 patients had mitral valve replacement, 21 underwent aortic valve replacement, and 15 had double valve replacement [Mitral k Aortic], and 1 had tricuspid valve replacement. Seventy-one cases [88.8 %] were in NYHA Class III or IV. The mean duration of follow up was 22.1 months and follow-up information was available for 74 [92.5 %] of the patients. The overall actuarial survival rate at 45 months was 93.05 % and overall hospital mortality was 10 %, late Mortality was 5 %. The linearlized incidence of thromboembolism [2.4%/pt-yr], thrombotic valve obstruction [1.6 %/pt-yr], anticoagulant related bleeding [0.8 %/pt-yr]. There were no fatal valve related complications. The blood was studied in 40 patients 1 year after valve operation. Hgb and reticulocyte count were within normal values and Serum LDH value was slightly elevated but it was not of clinical significance. In conclusion, Monostrut Bjork-Shiley valve prosthesis to be a reliable valve substitute with an acceptable incidence of complications.

  • PDF

Mitral Valve Replacement with a Pulmonary Autograft in an Infant

  • Jeong, Yong Ho;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • 제51권2호
    • /
    • pp.149-152
    • /
    • 2018
  • A 76-day-old infant weighing 3.4 kg was referred for surgical intervention for severe mitral valve stenoinsufficiency caused by leaflet fibrosis and calcification. He had ex perienced a cerebral infarction in the left middle cerebral artery territory, which was deemed attributable to an embolism of a calcified particle from the dysmorphic mitral valve. Because mitral valve replacement using a prosthetic valve was not feasible in this small baby, mitral valve replacement with a pulmonary autograft was performed. After a brief period of extracorporeal membrane oxygenation (ECMO) support, he was weaned from ECMO and was discharged home without further cardiovascular complications.