• 제목/요약/키워드: Valve prosthesis

검색결과 160건 처리시간 0.026초

임신중 발생한 인공승모판 혈전증의 혈전 용해제를 이용한 치료 -치험 1례 보고- (Thrombolytic Therapy for Prosthetic Mitral Valve Thrombosis of Pregnant Patient -A Case Report-)

  • 김영대
    • Journal of Chest Surgery
    • /
    • 제27권10호
    • /
    • pp.858-861
    • /
    • 1994
  • Prosthetic valve thrombosis is rare but it is one of fatal complication after heart valve surgery. Improvements of the valve design and the material have decreased the frequency of thrombosis but have not eliminated completely. And some cases of prosthetic valve thrombosis during pregnancy were reported inspite of adequate anticoagulation therapy.Urgent surgical intervention is indicated for prosthetic valve thrombosis but it is associated with high operative risk, therefore medical thrombolytic therapy such as urokinase or streptokinase therapy is regarded as an alternative therapy. This is a case report of the successful thrombolytic therapy for valve thrombosis in a pregnant patient after mechanical mitral valve replacement.

  • PDF

쎈트쥬드 대동맥판막의 장기 임상성적 (Clinical Results of the St. Jude Medical Valve in Aortic Pposition)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제28권3호
    • /
    • pp.258-262
    • /
    • 1995
  • We have experienced 18 abdominal aortic aneurysms between March,1987 and June,1994.Unruptured patients were 11 cases and ruptured were 7.The fifth[33.4% ,sixth[27.7% and seventh[27.7% decades were most common age distributions.Sex ratio was 2.6:1[m:f .The most frequent symptoms were abdominal or back pain and palpable pulsating mass.Sixteen patients underwent resection and graft replacement.One patient refused operation.Atherosclerosis was the underlying pathology in 76%.Two ruptured patients died postoperative[28.5% .The frequency of postoperative complication was higher in the ruptured group.

  • PDF

Early Clinical Experience with Sutureless Aortic Valve Replacement for Severe Aortic Stenosis

  • Kim, Do Jung;Kim, Hyo-Hyun;Lee, Shin-Young;Lee, Sak;Chang, Byung-Chul
    • Journal of Chest Surgery
    • /
    • 제51권1호
    • /
    • pp.1-7
    • /
    • 2018
  • Background: Sutureless aortic valve replacement (SU-AVR) has been developed as an alternative surgical treatment for patients with symptomatic severe aortic stenosis (AS). The aim of this study was to evaluate the clinical outcomes of SU-AVR through an assessment of hemodynamic performance and safety. Methods: From December 2014 to June 2016, a total of 12 consecutive patients with severe AS underwent SU-AVR. The endpoints were overall survival and valve-related complications (paravalvular leakage, valve thrombosis, migration, endocarditis, and permanent pacemaker implantation). The mean follow-up duration was $18.1{\pm}8.6months$. Results: The mean age of the patients was $77.1{\pm}5.8years$ and their mean Society of Thoracic Surgeons score was $9.2{\pm}17.7$. The mean cardiopulmonary bypass and aortic cross-clamp times were $94.5{\pm}37.3$ minutes and $54.9{\pm}12.5minutes$, respectively. Follow-up echocardiography showed good prosthesis function with low transvalvular pressure gradients (mean, $13.9{\pm}8.6mm\;Hg$ and peak, $27.2{\pm}15.0mm\;Hg$) at a mean of $9.9{\pm}4.2months$. No cases of primary paravalvular leakage, valve thrombosis, migration, or endocarditis were reported. A new permanent pacemaker was implanted in 1 patient (8.3%). The 1-year overall survival rate was $83.3%{\pm}10.8%$. Conclusion: Our initial experience with SU-AVR demonstrated excellent early clinical outcomes with good hemodynamic results. However, there was a high incidence of permanent pacemaker implantation compared to the rate for conventional AVR, which is a problem that should be solved.

ATS 인공 심장 판막의 단기 및 중기 임상성적 (Short and Intermediate Term Results of the ATS Heart Valve Replacement)

  • 임창영;문승철;양진영;구원모;김대식;이건;이헌재
    • Journal of Chest Surgery
    • /
    • 제32권11호
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

St.Jude Medical 판막의 임상성적 (Clinical Study of St.Jude Medical Cardiac Valve)

  • 김상형;장원채
    • Journal of Chest Surgery
    • /
    • 제27권2호
    • /
    • pp.114-121
    • /
    • 1994
  • St. Jude Medical cardiac valve replacement was performed in 135 consecutive patients from Aug.1986 to Dec. 1991.72 had mitral, 28 had aortic, 1 had tricuspid and 34 had double valve replacement. The hospital mortality rate was 4.4% & the late mortality rate was 3.7 %. Follow-up was done on 115 surviving patients:mean follow-up period was 29.78 $\pm$ 18.32 months. Paravalvular leakage was observed in two patients, possible prosthetic valvular endocarditis wasobserved in one patient and other specific valve-related complications were none. The overall actuarial survival rate at 6 years were 91.6% in total, 96.4% in aortic, 95.5 % in mitral and 81.9 % in double valve replacement.We concluded, therefore that good clinical results and a low complication rate could be achieved with St. Jude Medical valve in short-term follow-up & long-term follow-up was also necessary.

  • PDF

거대상행핵대동맥루를 동반한 대동맥륜확장증 수술 치험: Cabrol씨 수술 1례 보 (Surgical correction in annuloaortic ectasia associated with ascending aortic aneurysm: one case report)

  • 곽문섭
    • Journal of Chest Surgery
    • /
    • 제17권4호
    • /
    • pp.753-761
    • /
    • 1984
  • Most patients having annuloaortic ectasia are associated with marked dilatation of the sinuses of Valsalva and the aortic annulus as well as the huge aneurysm of the ascending aorta. A 19 year old male patient complaining of tightness on left posterior chest wall underwent cardiac angiography in which demonstrated annuloaortic ectasia with ascending aortic aneurysm and aortic insufficiency. The patient had corrective operation replacing the ascending aorta and aortic valve with a composite graft[Dacron prosthesis containing a Bjork-Shiley aortic valve] within the aneurysmal sac. The coronary orifices were anastomosed to the tubular Dacron prosthesis [30 mm in diameter] by means of a second smaller Gore-Tex tube [8mm in diameter]. The aneurysmal sac was trimmed by removing the redundant wall and then wrapped outer wall of the Dacron prosthesis. Postoperatively, mediastinal bleeding was temporarily observed in the operative day and satisfactory blood pressure was maintained with small dose of dopamine. One week later, large amount of serous effusion was drained out of the retrosternal space making partial disruption of the skin which was healed well by daily local dressing. The patient discharged in good condition on postoperative 29th day with no residual complications and is doing very well on the 4 months follow-up.

  • PDF

인공심장판막 실패에 대한 재치환술의 임상적 고찰 (Clinical Analysis of Reoperations on Prosthetic Valve Failur)

  • 최병철;유환국;안욱수;허용;김병열;이정호;유회성
    • Journal of Chest Surgery
    • /
    • 제24권7호
    • /
    • pp.663-668
    • /
    • 1991
  • To evaluate risks, complications and mortality of reoperations on heart valve prosthesis, we reviewed clinical records of 53 patients who underwent reoperation because of prosthetic valve failure[PVF], from Jan 1959 through Jun. 1991. They had undergone 48 mitral, 10 aortic valve rereplacement Primary tissue failure was the main cause of reoperation : it occurred in 51 valves at a mean postoperative interval of 58 months. Calcification and collagen disruption of prosthesis were main causes of primary tissue failure in macro and micropathology, In 3 failing mechanical prostheses, paravalvular leak was in 2 cases, another one case had the thrombi at the hinge portion. If conditions such as emergency operation with or without endocarditis, thromboembolism and advanced NYHA functional class are prevented, we think that reoperative valve replacement has similar morbidity and mortality to initial valve replacement surgery. But our sturdy represents higher mortality [22.6%] because of late surgical intervention failing the prevention of conditions leading to myocardial damage. In conclusion if the tearing, calcification, and a new murmur were detected the early reoperation should be considered to increase late survival.

  • PDF

인공판막의 비구조적 기능이상 (Nonstructural Dysfunction of Mechanical Valve)

  • 신종목;정동섭;김경환;안혁
    • Journal of Chest Surgery
    • /
    • 제34권1호
    • /
    • pp.91-93
    • /
    • 2001
  • 기계판막의 비구조적 기능이상은 판막 치환 후 생길 수 있는 심각한 합병증 중의 하나이다. 이러한 기계판막의 비구조적 기능이상은 일반적으로 1) pannus나 조직 혹은 봉합물질에 의한 장애 2) 치환 판막 주위의 틈 3) 부적절한 판막의 크기나 위치, 판막 삽입시의 잘못 등에 의해 생긴다. 저자들은 상대적으로 작은 판막륜을 가진 환자에서 치환 판막의 잘못된 위치로 야기된 pannus 형성에 의한 판막의 기능부전을 경험하였으며, 이 환자에 대해 pannus 제거 후 판막륜 확장술(닉스 술식, Nicks procedure)을 포함한 판막 재치환술을 성공적으로 시행하여 이를 보고하는 바이다.

  • PDF

인공심장판막의 재치환술 (Replacement of the Prosthetic Heart Valves -Clinical analysis of 12 cases-)

  • 김덕실;전상훈
    • Journal of Chest Surgery
    • /
    • 제29권2호
    • /
    • pp.164-170
    • /
    • 1996
  • From January 1986 to June 1993, 12 patients Aad required reoperation: 9 had undergone mitral and 3 aortic valve replacement. Five were male and 7 female, and ages ranged from 29 to 61 years. Replacement of the prosthetic heart valve was performed at a mean interval of 98 $\pm$ 1 months after the Hrst operation. In aortic valve replacement patients the mean interval was 115 $\pm$ 2 months and in mitral valve replacement patients 98 $\pm$ 4 months. Primary tissue failure was the most frequent reason of replacement (10 patients) followed by valve thrombosis (1 patient) and prophylactic replacement (1 patient) in order. The most pronounced pathology of the failed prosthetic heart valves seen in the primary tissue failure group was calcification, perforation, shrinkage and tearing of the cusps. There was one early operative death (8.3%) due to intractable low cardiac output and acute renal failure. Eleven early survivors had successful operative results and there was no late death.

  • PDF