• Title/Summary/Keyword: Valve prosthesis

Search Result 160, Processing Time 0.021 seconds

Long Term Results of Rastelli Operation with a Mechanical Valve (기계 판막을 이용한 라스텔리 수술의 장기 성적)

  • Choi, Se-Hoon;Kim, Kwan-Chang;Kwak, Jae-Gun;Kim, Chang-Young;Lee, Jeong-Ryul;Kim, Yong-Jin;Rho, Joon-Ryang;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.900-905
    • /
    • 2006
  • Background: Homografts and bioprostheses are most commonly used for Rastelli operation in congenital heart disease, but the limited durability is responsible for multiple reoperations associated with increased morbidity This study evaluated long-term results after Rastelli operation with a mechanical valved conduit. Material and Method: A total of 20 patients underwent Rastelli operation with mechanical valved conduit from January 1990 to July 1992. Operative mortality was 1 of 20 patients, and a retrospective review of 19 patients(10 males, 9 females) was done. Initial diagnosis was congenitally corrected transposition of great arteries(cc-TGA, n=4), complete TGA (n=2), ventricular septal defect with pulmonary atresia(VSD with PA, n=9), truncus arteriosus(n=2), double outlet right ventricle with pulmonary stenosis(DORV with PS, n=2). The mean age at Rastelli operation was $4.6{\pm}3.4$ years, and mean follow-up period was $12.8{\pm}2.7$ years. Patients underwent Rastelli opearation using 16 CarboMedics mechanical valve, and 3 Bjork-Shiley mechanical valve($17{\pm}2$ mm). Result: There were 15 reoperations for failed mechanical valved conduit. The freedom from reoperation at 5 and 10 years was 53% and 37%. Most patients were received oral anticoagulation with warfarin, and maintained the international normalized ratio(INR) of 1.5 to 2.0. There was no anticoagulation or thromboembolism related complication. There was a significant difference in the causes of a conduit failure between early(within 3 years) and late(after 3 years) failure groups. The six patients reported early prosthetic valve failure, mainly due to valvular dysfunction by thrombosis or pannus formation. The other nine patients reported late prosthetic valve failure, mainly due to dacron conduit stenosis at anastomosis sites, whereas their valvar motion was normal except 1 patient. Conclusion: To avoid early prosthetic valve failure, strict anticoagulation therapy would be helpful. About the late development of obstructive intimal fibrocalcific peels within the Dacron conduit, an improvement of conduit material is necessary to reduce late prosthetic valve failure. In selected patients, the long term results were satisfactory.

Midterm Results of the Bioprosthesis in Mitral Position (조직판막을 이용한 승모판 치환술의 중기 성적)

  • Cho, Hyun-Jin;Lee, Jae-Won;Jung, Sung-Ho;Je, Hyoung-Gon;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.695-702
    • /
    • 2008
  • Background: The choice between a bioprosthetic and a mechanical valve is an important decision in cardiac valve surgery, and the durability of the tissue valve is a major decision factor. We retrospectively evaluated the midterm results of bioprosthetic valve replacement in the mitral position. Material and Method: The subjects were all patients who had undergone mitral bioprosthesis replacement between July 1989 and August 200.7. Among the 216 patients, there were 236 surgical cases. The mean age was $63{\pm}15$ years, and the male to female ratio was 1 : 3. We retrospectively analyzed hospital and outpatient records such that the total follow-up duration amounted to 760.2 patient-years, and the mean follow-up duration was $41.9{\pm}40.7$ months (range $0{\sim}212$ months). Result: Early death occurred in 18 patients (8.3%), and 13 of these underwent concomitant cardiac procedures. The survival rate after 5 years was $79.9{\pm}3.5%$, and the survival rate after 8 years was $65.5{\pm}5.5%$, while freedom from structural valve deterioration (SVD) was $96.2{\pm}2.2%$ at 5 years and $85.9{\pm}5.3%$ at 8 years. Freedom from reoperation was $90.6{\pm}1.7%$ at 5 years and $90.4{\pm}4.2%$ at 8 years, while freedom from reoperation for SVD was $98.1{\pm}1.2%$ at 5 years and $92.3{\pm}4.1%$ at 8 years. On multivariate analysis of preoperative risk factors, small valve size (between 25mm and 27mm) was a significant risk factor for reoperation, and low LV ejection fraction (<40%) was a significant risk factor for SVD and mortality. Conclusion: Survival and freedom from reoperation for SVD in mitral bioprosthesis replacement had acceptable midterm results, but freedom from SVD Was relatively low. In particular, since SVD increased sharply at the eighth postoperative year, frequent follow-up and echocardiograms around that time will be helpful for the early detection of SVD. It will be necessary to conduct further studies involving long-term follow-up and more patients.

In Vivo Experiment of Tissue-Engineered Artificial Vessel (조직공학적 인조혈관의 생체 내 이식 실험)

  • 임상현;조승우;홍유선;김병수;유경종;장병철;최차용
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.220-227
    • /
    • 2004
  • The number of patients with coronary artery disease and peripheral vascular disease are increasing, and the need of small diameter vessel is also increasing. We developed small diameter artificial vessel and experimented in vivo. We got allogenic valve from mongrel dogs, and removed all cells from the allogenic valve. Then, we seeded autologous bone marrow cells onto the decellularized scaffold. After implantation of artificial vessel into the canine carotid artery, we performed angiography regularly. In case of vessel occlusion or at 8 weeks after operation, we euthanized dogs, and retrieved the implanted artificial vessels. Control vessels were all occluded except one (which developed aneurysmal dilatation). But autologous cell seeded vascular graft were patent by 4 weeks in one, by 6 in one and by 8 weeks in two. Histologic examination of patent vessel revealed similar structure to native artery. Tissue-engineered vascular graft manufactured with decellularized allogenic matrix and autologous bone marrow cells showed that tissue engineered graft had similar structure to native artery.

Pregnancy in Patients with Prosthetic Heart Valve (심장판막을 대치 받은 환자에서의 임신)

  • 이석열;장병철;박한기;박용원;강면식;홍승록;조범구;홍필훈
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1023-1030
    • /
    • 1999
  • This is a retrospective study of 42 pregnancies from 33 women with prosthetic heart valves who were on anticoagulation regimen prior to or during their pregnancy. Material and Method: Of the 17 women with bioprosthesis, 15 had 21 pregnancies following cessation of the anticoagulation therapy which resulted in the delivery of 20 healthy babies and 1 abortion. Remaining 2 had 3 pregnancies maintained with heparin, resulting in 2 healthy babies and 1 spontaneous abortion. Result: Among 16 women with mechanical heart valves, there were 7 pregnancies during which warfarin was used and this was associated with 4 fetal wastages(2 therapeutic abortion, 1 spontaneous abortion and 1 stillbirth with cerebral hemorrhage). However, in pregnancies where heparin was used, there was no fetal wastage. A patient who did not take anticoagulant for the first trimester and took warfarin for the remaining period and a patient who did not take anticoagulant during pregnancy delivered normal babies. There was an other fetal wastage in a patient on anti-platelet therapy for the first trimester and warfarin therapy for the remaining periods. There was 1 minor petechial complication in a heparin administered group. Conclusion: The study indicates that woman with bioprosthetic heart valves can go through pregnancy without undue risks or complications. On the other hand, the use of warfarin during pregnancy in women with mechanical heart valves, was shown to be associated with unacceptable high risk for the fetus. However, in the same group of women, judicious use of heparin during pregnancy was accompanied by a much reduced risk. The safety and adequate therapeutic range of heparin usage under such circumstances are subject to further studies.

  • PDF

Surgical Treatment for Dissecting Aneurysm of the Aorta using Sutureless Intraluminal graft (무봉합 혈관내 인조이식혈관을 이용한 박리성 대동맥류의 수술요법)

  • 이재원
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.305-313
    • /
    • 1985
  • Surgical therapy for dissection of the aorta has had a high mortality. One contributing factor has been hemorrhage from the prosthesis and the suture lines. Recently, a new method of treatment with an intraluminal graft that requires no end-to-end anastomosis has been developed. Of the four patients with dissecting aneurysm of the aorta treated by inserting sutureless ringed intraluminal graft at the Department of Thoracic and Cardiovascular Surgery, S.N.U.H., three were DeBakey type I [one with associated aortic insufficiency] and the other was DeBakey type III. Suspected etiology of the dissection was Marfan`s syndrome in one and hypertension in the others. Total cardiopulmonary bypass was utilized in repairing dissecting aneurysms of the ascending aorta [type A] and simple aortic crossclamping was used for the patient with dissecting aneurysm of the descending aorta. The basic technique consists of inserting the whole ringed graft into the true lumen of the dissected aorta and circumferentially ligating the aorta against the groove in the rings. The proximal ring of the graft effectively stabilized the flail aortic valve in patient with aortic insufficiency associated with dissection of the ascending aorta. There were no hospital deaths and one patient with type III dissecting aneurysm developed postoperative paraparesis and renal insufficiency which was resolved. Follow-up has been from 1 month to 16 months with no evidence of prosthetic problems, such as erosion, migration, or thrombosis.

  • PDF

Supravalvular Aortic Stenosis - Report of 3 cases - (대동맥판상부협착증: 치험 3례)

  • 전예지
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.280-286
    • /
    • 1991
  • Supravalvular aortic stenosis may be defined as an obstructive congenital deformity of the ascending aorta which originates just distal to the level of the origins of the coronary arteries It may be localized or diffuse. Enlargement of the aorta with a diamond-shaped patch of the noncoronary sinus of Valsalva was reported in 1961 by McGoon and associates But this reconstruction is asymmetric and the aortic obstruction may remain. In 1977, Dotty and associates reported the extended aortoplasty, the supravalvular ring was incised at two points in the noncoronary and in the right coronary sinuses of Valsalva closed with a tubular Dacron prosthesis of inverted Y-shape tailored to reconstruct the aorta We experienced three cases of the supravalvular aortic stenosis. The 11-year-old female and 4-year-old male with localized supravalvular aortic stenosis in William`s syndrome were operated with an inverted Y-shaped aortotomy toward the non-coronary sinus and the right coronary sinus and closed with "Hemashield`s collagen impregnated Dacron" tube graft, fashioned into "pantaloon" form patch. The 12-year-old male with localized supravalvular aortic stenosis and mitral insufficiency in William`s syndrome were operated with same procedure as two other patient above-mentioned for relief of supravalvular aortic stenosis and with mitral valve replacement. Postoperative course has been good.ourse has been good.

  • PDF

Short Term Clinical Experiences of 52 Sorin Bicarbon Mechanical Valves (Sorin Bicarbon 기계판막의 단기 임상성적)

  • Lee, Cheol-Joo;Choi, Ho;Kim, Jung-Tai;Soh, Dong-Moon;Roh, Hwan-Kyu;Han, Jeong-Seon
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.679-683
    • /
    • 1998
  • From June 1995 to May 1997, we have implanted 52 Sorin Bicarbon mechanical valves in 41 patients. They were 16 men and 25 women, and their mean age was 47.4${\pm}$14.8(range; 18∼74 y.o.). 35(27 mm∼31 mm) were in mitral position, 15(19 mm∼25 mm) in aortic position, and 2(31 mm) in tricuspid position. 3 CABGs and a tumor excision were taken concomittantly. 35 patients were primary operation, and 6 were re-do operations. By intraoperative transesophageal doppler echocardiography, transvalvular peak/mean pressure gradient was 6.1${\pm}$2.7/2.4${\pm}$1.4 mmHg in mitral position and 27.6/10.7 mmHg in aortic position. The effective valve opening area in mitral position was 3.2${\pm}$0.6 cm2. Follow-up was total 508.6 patient-months, and mean follw-up was 12.7${\pm}$9.2 months. NYHA class was improved from 2.6${\pm}$0.6 to 1.2${\pm}$0.3 in average postoperatively. During that period, there was no operative death. 2 late non-valve related deaths were occurred. One was died of COPD, and the other was possible acute myocardial infarction. Among 7 postoperative complications, one valve related complication(minimal paravalvular leakage) was noticed. In conclusion, Sorin Bicarbon mechanical valve is believed one of the safe choice in clinical settings. It showed excellent hemodynamic and mechanical functions, and very low postoperative valve related complications in short term clinical experience.

  • PDF

Relationship between Warfarin Related Knowledge, Self Efficacy and Medication Adherence of Patient with Prosthetic Heart Valve Replacement (인공심장판막치환 환자의 와파린 관련 지식, 자기효능감 및 약물복용이행도의 관계)

  • Kil, A-Ram;Shin, Yong Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.584-592
    • /
    • 2020
  • The purpose of this study is to explore the relationship between warfarin-related knowledge, self-efficacy, and medication adherence among patients who underwent heart valve replacement surgery. The patients who underwent heart valve surgery and warfarin therapy were included in this study. The data was collected by administering questionnaires, and the data was then analyzed using the SPSS WIN 22.0 program. There was a positive relationship between warfarin-related knowledge and the adherence to medication (r=.285, p=004). Medication adherence was also positively correlated with warfarin-related knowledge (r=.250, p=.046) and self-efficacy (r=.292, p=.019) for elderly patients under 70 years of age. Further, medication adherence of elderly patients over 70 years of age was correlated with only warfarin-related knowledge (r=.358, p=.032). The results of this study show that in order to improve medication adherence, elderly people should be provided with warfarin-related knowledge through individually tailored education and nursing interventions that strengthen self-efficacy, as well as the knowledge that is needed in the elderly group under 70 years old.

Aortic and Mitral Valve Replacement with Reconstruction of the Intervalvular Fibrous Skeleton in Prosthetic Valve Endocarditis (인공판막 심내막염에서 판막간 섬유체 재건을 이용한 대동맥판 및 승모판 치환술)

  • Baek, Man-Jong;Kim, Wook-Sung;Oh, Sam-Se;Jeon, Yang-Bin;Ryu, Jae-Wook;Kong, Joon-Hyuk;Lim, Cheong;Kim, Soo-Cheol;Kim, Woong-Han;Na, Chan-Young;Lee, Seong-Ki;Lee, Chang-Ha;Lee, Young-Tak;Yoon, Youg-Woong;Park, Young-Kwang;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.34 no.7
    • /
    • pp.561-565
    • /
    • 2001
  • Patients who have complex endocarditis with involvement of both the aortic and mitral valves and intervalvular fibrous skeleton are among the most difficult to treat and still have the highest surgical mortality and morbidity rates. We report one case of aortic and mitral valve replacement with reconstruction of the fibrous skeleton performed in a 55-year-old female patient who had an aortic annular abscess and both the aortic and mitral prosthetic valve endocarditis with destruction of the fibrous skeleton. Previously, she had undergone redo double valve replacement\`, Transesophageal echocardiogram showed the paravalvular defect at the noncoronary aortic sinus and abnormal sinus tract along the fibrous skeleton. Emergent operation was performed due to positive blood cultures of staphylococcus epidermidis and persistent sepsis despite appropriate antibiotic therapy. After aortotomy extended to the roof of left atrium, both prosthetic valves and destroyed fibrous skeleton were completely resected and the aortic annular abscess was debrided and closed with a bovine pericardial patch. Reconstructions of both aortic and mitral annuli and the fibrous skeleton were done by using two separate bovine pericardial patches in triangular shape and mechanical valves were implanted. Postoperatively, adequate antibiotic therapies were continued and the patient was discharged at the postoperative 72 days without evidence of recurrence of endocarditis. Transthoracic echocardiogram of the postoperative 8 months shows no paravalvular leakage or recurrence of endocarditis and the patient has been followed up with no symptom.

  • PDF

Determination of Practical Dosing of Warfarin in Korean Outpatients with Mechanical Heart Valves (인공심장판막 치환환자의 Warfarin 용량결정)

  • Lee Ju Yeun;Jeong Young Mi;Lee Myung Koo;Kim Ki-bong;Ahn Hyuk;Lee Byung Koo
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.761-772
    • /
    • 2005
  • Background: Following the implantation of heart valve prostheses, it is important to maintain therapeutic INR to reduce the risk of thromboembolism. The objective of this study was to suggest a practical dosing guideline for Korean outpatients with prosthetic heart valves managed by a pharmacist-run anticoagulation service (ACS). Material and Method: A retrospective chart review was completed for all patients enrolled in the ACS at Seoul National University Hospital from March, 1997 to September, 2000. Patients who were at least 6 months post-valve replacement and had nontherapeutic INR value (less than 2.0 or greater than 3.0) were included. The data on 688 patients (1,782 visits) requiring dosing adjustment without any known drug or food interaction with warfarin were analyzed. The amount of adjusted dose and INR changes based on the INR at the time of the event were calculated. Aortic valve replacements (AVR) patients and mitral or double valve replacement (MVR/DVR) patients were evaluated separately. Result: Two methods for the warfarin dosage adjustment were suggested: Guideline I (mg-based total weekly dose (TWD) adjustment), Guideline II (percentage-based TWD adjustment). The effectiveness of Guideline 1 was superior to Guideline II overall in patients with both AVR and MVR/DVR. Conclusion: The guideline suggested in this study could be useful when the dosage adjustment of wafarin is necessary in outpatients with mechanical heart valves.