• Title/Summary/Keyword: Valve prosthesis

Search Result 160, Processing Time 0.031 seconds

Establishment of Valve Replacement Registry and Risk Factor Analysis Based on Database Application Program (데이터베이스 프로그램에 기반한 심장판막 치환수술 환자의 레지스트리 확립 및 위험인자 분석)

  • Kim, Kyung-Hwan;Lee, Jae-Ik;Lim, Cheong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.209-216
    • /
    • 2002
  • Background: Valvular heart disease is still the most common health problem in Korea. By the end of the year 1999, there has been 94,586 cases of open heart surgery since the first case in 1958. Among them, 36,247 cases were acquired heart diseases and 20,704 of those had valvular heart disease. But there was no database system and every surgeon and physician had great difficulties in analysing and utilizing those tremendous medical resources. Therefore, we developed a valve registry database program and utilize it for risk factor analysis and so on. Material and Method: Personal computer-based multiuser database program was created using Microsoft AccessTM. That consisted of relational database structure with fine-tuned compact field variables and server-client architecture. Simple graphic user interface showed easy-to-use accessability and comprehensibility. User-oriented modular structure enabled easier modification through native AccessTM functions. Infinite application of query function aided users to extract, summarize, analyse and report the study result promptly. Result: About three-thousand cases of valve replacement procedure were performed in our hospital from 1968 to 1999. Total number of prosthesis replaced was 3,700. The numbers of cases for mitral, aortic and tricuspid valve replacement were 1600, 584, 76, respectively. Among them, 700 patients received prosthesis in more than two positions. Bioprosthesis or mechanical prosthesis were used in 1,280 and 1,500 patients respectively Redo valve replacements were performed in 460 patients totally and 40 patients annually Conclusion: Database program for registry of valvular heart disease was successfully developed and used in personal computer-based multiuser environment. This revealed promising results and perspectives in database management and utilization system.

Successful emergency transcatheter aortic valve implantation

  • Lee, Jung-Hee;Ji, Ah-Young;Kim, Young Ju;Song, Changho;Jin, Moo-Nyun;Kim, Sun Wook;Hong, Myeong-Ki;Hong, Geu-Ru
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.144-147
    • /
    • 2014
  • Despite the necessity of surgical aortic valve replacement, many patients with symptomatic severe aortic stenosis (AS) cannot undergo surgery because of their severe comorbidities. In these high-risk patients, percutaneous transcatheter aortic valve implantation (TAVI) can be safely accomplished. However, no study has shown that TAVI can be performed for patients with severe AS accompanied by acute decompensated heart failure. In this case report, 1 patient presented a case of severe pulmonary hypertension with decompensated heart failure after diagnosis with severe AS, and was successfully treated via emergency TAVI. Without any invasive treatment, acute decompensated heart failure with severe pulmonary hypertension is common in patients with severe AS, and it can increase mortality rates. In conclusion, TAVI can be considered one of the treatment options for severe as presented as acute decompensated heart failure patients with pulmonary hypertension.

Surgical Treatment of Degenerative Mitral Valve Regurgitation in the Elderly: Comparison of Early and Long-Term Outcomes Using Propensity Score Matching Analysis

  • Lee, Joon Seok;Kim, Kyung Hwan;Choi, Jae Woong;Hwang, Ho Young;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.51 no.6
    • /
    • pp.367-375
    • /
    • 2018
  • Background: It is unclear whether mitral valve (MV) repair for degenerative mitral regurgitation (MR) provides the same advantages in the elderly that it does in the general population. Methods: From 1994 to 2016, 188 elderly patients (mean age, $68.3{\pm}5.50years$) underwent MV repair (n=153) or MV replacement (n=35) for primary degenerative MR. Early and long-term outcomes were compared before and after propensity score matching (PSM). Results: Before PSM, there was a significant difference in operative mortality (p=0.011). Overall survival and freedom from cardiac-related death (CRD) at 5, 10, and 15 years were significantly higher in patients who underwent MV repair (p=0.039 and p=0.007, respectively). In the multivariable analysis, MV replacement was an independent risk factor of CRD. After PSM, operative mortality was not significantly lower in patients who underwent MV repair (p=0.125). Overall survival and freedom from CRD at 5, 10, and 15 years showed no significant difference between the 2 groups in the PSM cohort (p=0.207, p=0.47, respectively). There was no significant difference in freedom from reoperation before or after PSM (p=0.963 and p=0.575, respectively). Conclusion: MV repair for primary degenerative MR might be a valid option in the elderly population if successful repair is possible.

Six-year Clinical Experience with CarboMedics Valve (CarboMedics 판막의 6년 임상 성적)

  • 구본원;허동명
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.971-976
    • /
    • 1996
  • From March 1988 to October 1992, 201 CarboMedics cardiac valve prostheses (150 mitral, 50 aortic and 1 tricuspid) were implanted in 166 consecutive patients (mean age 38 years, male/female 66/100) by one surgical team operating on adult cardiac patients at Kyungpook University Hospital. Total follow up represen:toed 6646 patient-months (mean 40mon1hs) and follow up rate was 96%. One hundred and twenty-four patients (74.7 %) were in NYHA functional class 111 or tV preoperatively and 164 patients (98.7 %) were in class I or ll postoperatively. Hospital mortality was 4.2 % and late death was 4.2%. The actuarial survival at 78 months was 89.4%. The linearized incidence of valve related death, prosthetic valve thrombosis, anticoagulant related hemorrhage, non-structural dysfunction and reoperation was 0.72%/pt-yr, 0.18%/pt-yr, 0.18%trapt-yr, 0.18 %/pt-yr and 0. 36%/pt-yr respective y. The 78 month rates of freedom from valve related death, prosthetic valve thrombosis, anticoagulant related hemorrhage, non-structural dysfunction and reoperation were 94.9%, 99.4%, 99.4%, 98.6 % and 97.9 % respectivly. The 78 month rate of freedom from all valve related complications and deaths including hospital mortality was 90.9%. These fact suggest that the CarboMedics cardiac valve has execellent result, low incidence of valve-ie-lated complications and no structural deterioration, and long term follow up study is necessary.

  • PDF

Hemolytic Anemia due to Tiny Prosthetic Paravalvular Leakage (작은 인공판막주위 누출에 의한 용혈성 빈혈)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.444-448
    • /
    • 1996
  • Hemolytic anemia due to tiny prosthetic paravalvular leakage is one of a complication of prosthetic valve replacement. Mild Hemolysls usually occurs after aortic valve replacement with mechanical valve but rarely occurs in mitral valve position especially in case of tissue valve. Cardiac valves fabricated from biologic material are associated with a reduced incidence of hemolytic anemia. Hemolysis was reported in patients with an lonescu-Shiley bovine pericardial xenograft prosthesis in the aortic position but not in the mitral site. A 41-year-old female patient was admitted due to sudden development dark colored urine. About 10 years ago the patient was underwent MVR (Mitral Valve Re lacement) with fTmm lonescu-Shiley valve due to MR (Mitral regurgitation). Echocardiographic examination showed mild degree of mitral regurgitation with valvular thickening. However, there was no definitive evidence of paravalvular leakage. The peripheral blood smear showed nomochromic normocytic anemia, but the hematologic and urinary examination revealed severe hemolytic evidence. Mitral valve replacement with St. Jude Medical valve (27mm) was done and intraoperatively, a tiny paravalvular leakage was found which was regarded as the point of hemolysis. The hemolytic evidence completely disappeared. We are reporting a case of severe hemolytic anemia due to tiny prosthetic paravalvular leakage with a review of the literature.

  • PDF

Midterm Results of Aortic Valve Replacement Using Tissue Valve (조직판막을 이용한 대동맥판막치환술의 중기성적)

  • Moon, Duk-Hwan;Lee, Jae-Won;Kim, Yun-Seok;Cho, Won-Chul;Jung, Sung-Ho;Choo, Suk-Jung;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.627-634
    • /
    • 2010
  • Background: The durability of the tissue valve is important in choice between a mechanical valve and a tissue valve in cardiac surgery. We studied the mid-term results of tissue valve in the aortic position. Material and Method: The subjects were 380 patients who had undergone aortic prosthesis replacement between May 1990 and March 2009. We retrospectively analyzed hospital and outpatient records: the mean age was $69{\pm}9$ years; the male to female ratio was 227 : 162; and the mean follow-up duration was $46.7{\pm}40.8$ months (range 0~196 months). Result: 389 surgical cases in total had been taken with 380 patients. Early death occurred in 15 patients (3.9%). Overall survival rate at 1, 5 and 10 years were 92.3%, 78.1% and 54.2% respectively. Freedom from reoperation at 1, 5 and 10 years were 98.4%, 97.1% and 91.7% respectively. Freedom from structural valvular deterioration at 1, 5 and 10 years were 96.1%, 92.3% and 88.0% respectively. In the multivariate analysis of preoperative risk factors, young age (p<0.001) was significant risk factor for reoperation. High peak velocity in the postoperative period (p=0.034) and young age (p=0.029) were significant risk factors for structural valvular deterioration. Old age (p=0.001), long bypass time (p=0.035), concomitant coronary artery bypass graft surgery (p=0.003) and preoperative low left ventricular ejection fraction (p=0.003) were significant factors for early mortality. Preoperative estimated glomerular filtration rate (< 60 mL/min) (p=0.025) and persistent left ventricular hypertrophy (p=0.032) were the risk factors for late mortality. Conclusion: This study showed that the freedom from reoperation and the freedom from structural valvular deterioration in aortic tissue valve replacement were acceptable. It will be necessary to conduct further studies with long-term follow-up and more patients.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.

Regression of Left Ventricular Hypertrophy after AVR in Aortic Valvular Stenosis (대동맥판막협착증 환자에서 판막치환 후 좌심실심근비후의 변화)

  • 이재원;최강주;송명근
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.586-590
    • /
    • 1998
  • Background: The regression of the left ventricular hypertrophy after prosthetic valve replacement in patients with aortic valvular stenosis is an important factor to determine the appropriateness of the replaced prosthetic valvular size. Methods: To assess the regression of myocardial hypertrophy, a retrospective analysis of Doppler echocardiographic and electrocardiographic data was undertaken before, soon after(7.5$\pm$2.1 day), and late after(10.7$\pm$1.8 months) surgery in 36 patients(22 males, 14 female, mean age 54$\pm$12.1 years, mean BSA 1.61$\pm$0.15m2) with predominant aortic valvular stenosis. The patients underwent St. Jude Medical aortic valve replacement. By the size of the valves used, the patients were divided into three groups(19, 21 and 23+). Results: The mean body surface area(1.48$\pm$0.13) in the patients with the 19 mm valve was smaller than that in the other groups(1.63$\pm$0.12)(p<0.05). No significant changes of ejection fraction were detected in all groups over time. Left ventricular muscle mass index(gm/m2) was reduced significantly in the 21 and 23+ groups over time(p<0.05), but there were no significant changes in the 19 mm valve group. The electric voltage height on EKG at the period of late after surgery was reduced significantly in all groups(p<0.05). Conclusion: Despite clinical improvement, the LVH was not reduced significantly in 19 mm valve group. Thus we suggest that more attention and additional procedures such as annular enlargement should be taken in patients who will undergo the replacement of 19 mm prosthetic valve.

  • PDF

Thrombolytic Therapy for Repeated Prosthetic Valvular Thrombosis That's Associated with Pregnancy under Heparin Anticoagulation (임신과 연관된 헤파린 항응고요법 중 반복적으로 발생한 인공판막 혈전증의 혈전용해치료)

  • Choe, Ju-Won;Kim, Yong-In L.
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.484-488
    • /
    • 2008
  • During long-term anticoagulation treatment with using heparin in a pregnant patient with a mechanical mitral prosthesis, we observed several anticoagulation-related complications, including repeated prosthetic valve thrombosis. This was found to be caused by heparin resistance due to an anti-thrombin III deficiency. Thrombolytic therapy using urokinase or tissue plasminogen activator (tPA) was successful and safe for her as well as her baby.

Long-Term Results of the Leaflet Extension Technique for Rheumatic Aortic Regurgitation: A 20-Year Follow-up

  • Kwak, Yu-jin;Ahn, Hyuk;Choi, Jae Woong;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.52 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • Background: Although aortic valve repair can reduce prosthesis-related complications, rheumatic aortic regurgitation (AR) caused by leaflet restriction is a significant risk factor for recurrent AR. In this study, we evaluated the long-term results of the leaflet extension technique for rheumatic AR. Methods: Between 1995 and 2016, 33 patients underwent aortic valve repair using the leaflet extension technique with autologous pericardium for rheumatic pure AR. Twenty patients had severe AR and 9 had combined moderate or greater mitral regurgitation. Their mean age was $32.2{\pm}13.9$ years. The mean follow-up duration was $18.3{\pm}5.8$ years. Results: There were no cases of operative mortality, but postoperative complications occurred in 5 patients. Overall survival at 10 and 20 years was 93.5% and 87.1%, respectively. There were no thromboembolic cerebrovascular events, but 4 late deaths occurred, as well as a bleeding event in 1 patient who was taking warfarin. Twelve patients underwent aortic valve reoperation. The mean interval to reoperation was $13.1{\pm}6.1$ years. Freedom from reoperation at 10 and 20 years was 96.7% and 66.6%, respectively. Conclusion: The long-term results of the leaflet extension technique showed acceptable durability and a low incidence of thromboembolic events and bleeding. The leaflet extension technique may be a good option for young patients with rheumatic AR.