• Title/Summary/Keyword: Valve disease

Search Result 420, Processing Time 0.026 seconds

A study of postoperative pulmonary arterial pressure change in the acquired heart disease with pulmonary hypertension (폐동맥 고혈압을 동반한 후천성 심질환의 술후 폐동맥압의 변화에 대한 연구)

  • 류삼렬
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.245-252
    • /
    • 1990
  • To see the change of pulmonary arterial pressure after mitral valve replacement, postoperative cardiac catheterization and echocardiographies were performed in 12 patients of mitral valvular disease with pulmonary hypertension[systolic pulmonary arterial pressure>50 mm Hg]. The mean follow-up duration was 35.4[range: 15-47] months per patient. The following results were obtained. 1] Preoperative systolic pulmonary arterial pressure value of 66.17\ulcorner10.73mmHg decreased significantly to 29.17\ulcorner6.86mmHg postoperatively[p<0.01]. 2] Preoperative Pp/Ps value of 0.67\ulcorner0.13 decreased significantly to 0.28\ulcorner0.06 postoperatively[p<0.01]. 3] Preoperative PAWP value of 29.00\ulcorner4.02mmHg decreased significantly to 9.92\ulcorner4.27 mmHg postoperatively[p<0.01]. 4] Preoperative LAD value of 5.58\ulcorner1.20cm decreased significantly to 4.37\ulcorner0.67cm postoperatively [p<0.01]. In conclusion, pulmonary arterial hypertension secondary to mitral valvular disease could be reduced to normal range after successful mitral valve replacement.

  • PDF

Clinical analysis of 60 cases of open heart surgery (개심술 치험 60례 보)

  • Kim, Su-Seong;Kim, Yeong-Ho;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.389-397
    • /
    • 1984
  • Sixty cases of open heart surgery were performed in the Department of Thoracic and Cardiovascular Surgery of Chonbuk National University Hospital from July, 1983 to June, 1984. The patients were consisted of 40 [66%] congenital anomalies containing 26 [43%] patients of acyanotic group and 4 [23%] of cyanotic group, and 20 [34%] acquired heart diseases which involved one or more cardiac valves. The male patients were 42 and the female 18. In 20 valvular heart diseases, open mitral commissurotomy was done in 5 patients, mitral valvular replacement with tissue valve in 6, mitral valvular replacement with mechanical valve in 5, mitral valvular replacement with tricuspid annuloplasty in 2, mitral annuloplasty in 1, and mitral and aortic valvular replacements with mechanical valves in 1. The most frequency complication was low cardiac output syndrome occurred in 9, and the next was urethral stenosis, ARDS, and postoperative bleeding, etc. The perioperative mortality was 21% in congenital cyanotic heart disease, 12% in congenital acyanotic heart disease, and 5% in acquired heart disease.

  • PDF

Development and Animal Tests of Artificial Heart Valves (인공심장판막의 개발 및 동물실)

  • 이재영
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.458-472
    • /
    • 1987
  • A heart supplies bloods of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to this act of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of bloods. In an attempt to eliminate the affliction of heart valves, the operation method to repair with artificial heart valves has been developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. The artificial heart valve using pyrolytic carbon has been developed at KAIST, which was proved to be stable in the mechanical performance and durability. Therefore, the in viva performance of this valve was examined through animal tests. The artificial heart valves used in this study are tilting disc type valves, in which the disc were made of graphite coated with pyrolytic carbon and the cages were made of titanium. In viva testings of these valves were performed in 12 dogs, in which right ventriculo-pulmonary arterial [Croup I] or inter-aortic [Croup IV] valved conduit was implanted using polytetrafluoroethylene conduits containing KAIST valve and aortic valve [Group II] or pulmonary valve [Croup III] was replaced by a KAIST valve with a 21mm or 19mm tissue annulus diameter. In group I and II, pre-and post-operative transvalvular pressure gradient was measured and compared with other prosthetic valves. During post operative period laboratory examination was performed including hemoglobin, hematocrit, red cell count, white cell, lactic acid dehydrogenase and platelet. The eight surviving dogs were sacrificed and autopsy was performed at 2, 6, and 8 weeks. KAIST valve has low transvalvular gradient and relatively high orifice area. Average ventriculo-aortic peak systolic transvalvular gradient was 14 mmHg in 21 mm valve and 19 mmHg in 19 mm valve. The valve has slight intravascular hemolysis effect. Thrombogenic effect of low polishing quality and eddy currents around small orifice is high. The valve has vulnerability of disc movement. These animal tests suggest that the improvement of the heart valve design, surface polishing state and prescription methods.

  • PDF

One Hundred Cases of Open Heart Surgery in 1977 (1977년도 년간 개심술 100례 보고)

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.213-226
    • /
    • 1978
  • One hundred cases of open heart surgery were done at this Department in 1977. There were 65 congenital anomaly and 35 acquired diseases. Out of 65 cases of congenital malformation 35 acyanotic and 30 cyanotic cases were found. Fifteen cases of ventricular septal defect and 29 tetralogy of Fallot were noted eight patients expired out of 65 congenital anomaly [12.3%] , 4 out of 35 acyanotic [11. 4%] and 4 among 30 cyanotic anomaly[13.3%]. Among 35 cases of acquired heart disease 3 atrial myxoma [2 left and one right] and 32 valvular lesions were noted. In two cases open mitral commissurotomy, and in 30 valve replacement were done. Twenty-two single valve and 8 double valve replacement were done. Seven patients expired out of 30 patients [23.3%]. Among 22 single valve replacement cases 2 and among 8 double valve 5 died. ~ In eighteen mitral valve replacement cases 2 deaths occurred. One mitral insufficiency patient who expired suffered from severe pulmonary` hypertension [PA=120/67mmHg], tricuspid insufficiency and a large ventricular septal defect. The patient underwent mitral valve replacement, tricuspid annuloplasty and patch closure of ventricular septal defect. Over all mortality rate for 100 open heart surgery cases was 15%. Since 1977 open heart surgery cases were done routinely in this institution and cases are increasing rapidly. With present rapid improvement of economical status and introduction of medical insurance system, open heart surgery will be firmly established in Korea in the very near future.

  • PDF

Clinical Experience of Multiple Valve Replacement (다중판막 치환술의 임상 성적)

  • Choe, Sun-Ho;Lee, Sam-Yun;Kim, Hyeong-Gon
    • Journal of Chest Surgery
    • /
    • v.28 no.4
    • /
    • pp.346-354
    • /
    • 1995
  • Records of 71 consecutive patients who had received multiple valve replacement were reviewed[34male,37female,mean age 40.5$\pm$11.2 <14-63> . The early death rate was 2.8%[2/71 . A completed follow-up rate of 95.7% was accomplished in these 69 patients who left hospital[mean 42.5 $\pm$29.5 patients-years . Five of these patients died. The late death rate was 7.2%. Four patients experienced anticoagulant-related hemorrhage[all were minor . One patient had a thromboembolic episode[permanent ,and 2 had late prosthetic valve endocarditis. There was no clinical evidence of hemolysis and structural failure of valves used. Of those patients who survived,NYHA functional class improved significantly[from 87.2% class III & IV before to 95.8% class I & II after . Linearized rates for thromboembolism and anticoagulant-related hemorrhage,and for prosthetic valve endocarditis were 0.67%/100 patient-years,2.95%/100 patient-years,1.34%/100 patient-years, respectively. The actuarial estimates of incidence free of all complications and valve-related deaths were 92.2%/patient-years.Despites the advanced heart disease involving two or more native valves, the patients who had multiple valve replacement had very good results, over a 9-year period.

  • PDF

Right anterior mini-thoracotomy aortic valve replacement versus transcatheter aortic valve implantation in octogenarians: a single-center retrospective study

  • Ji Eun Im;Eun Yeung Jung;Seok Soo Lee;Ho-Ki Min
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.96-102
    • /
    • 2024
  • Background: The aim of this study was to compare the early outcomes of octogenarians undergoing minimally invasive right anterior mini-thoracotomy aortic valve replacement (RAT-AVR) with those undergoing transcatheter aortic valve implantation (TAVI) for aortic valve disease. Methods: In this single-center retrospective study, data were collected from octogenarians before and after RAT-AVR and TAVI between January 2021 and July 2022. Short-term outcomes, including the length of hospital stay, in-hospital mortality, all-cause mortality, and other major postoperative complications, were compared and analyzed. Results: There were no significant differences in in-hospital mortality, stroke, acute kidney dysfunction requiring renal replacement therapy, length of intensive care unit stay, or length of hospital stay. However, the TAVI group had a higher incidence of permanent pacemaker insertion (10% vs. 0%, p=0.54) and paravalvular leaks (75% vs. 0%, p<0.001). Conclusion: In the present study on octogenarians, both TAVI and RAT-AVR showed comparable short-term results. Although both procedures were considered safe and effective in the selected group, RAT-AVR had a lower incidence of complete atrioventricular block and paravalvular regurgitation.

Left Atrial Thrombi in Patients With Mitral Stenosis (Risk Factors Related to left Atrial Thrombosis) (승모판협착증 환자의 좌심방혈전)

  • Kim, Kwang-Ho;Hong, Sung-Nok
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.204-212
    • /
    • 1982
  • The presence of left atrial thrombus in mitral stenosis has been reported to be associated with several factors. These are age, sex, presence of atrial fibrillation, episodes of congestave heart failure, calcification of mitral valve, embolic episode, etc. Since none of these single factor has been always related to the presence of left atrial thrombus, related risk factors to left atrial thrombosis were studied in patients with mitral stenosis using chi square test. We had operated on 191 cases of mitral valvular heart disease from Jan. 1978 to June 1981 at Severance Hospital, Yunsei University College of Medicine. The left atrial thrombi were present in 41 cases among 191 cases of mitral valvular heart disease and it was present in 31 cases among 89 cases of pure mitral stenosis. Only 10 cases among 74 cases of mitral stenoregurgitation had left atrlal thrombi, whereas no left atrlal thrombus was found in patients with pure mitral regurgitation. Related risk factors studied herein were sex, episodes of congestive heart failure, atrial fibrillation, pulmonary capillary wedge pressure, mitral valve area calculated by Gorlin and Gorlin`s formula cardiac output and left atrial dimension by echocardiogram. In this study presence of atrial fibrillation was deemed to be one of the most potential risk factors and other factors of age, duration of symptoms, episode of embolization, calclfication of mitral valve, associated aortic and tricuspid valve disease, ejection fraction of left ventricle by cineangiocardiogram and echocardiogram were not significantly related to the presence of left atrlal thrombi in a statistical viewpoint.

  • PDF

Clinical Evaulation of Reoperation for Mitral Vavular Disease (승모판막질환의 재수술에 대한 임상적 고찰)

  • Kim, Myung-In;Kim, Eung-Joong;Lee, Young
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.49-56
    • /
    • 1992
  • Total 20 cases of reoperation for mitral vavular disease, which had been performed during the period from May 1983 till October 1991, were reviewed. This study contained 1 case of previous balloon valvuloplasty and 1 case of death with bleeding from right ventricle during sternal reenrty. The average time intervals between reoperation and previous operation was 19 years in closed mitral commissurotomy[n=4], 7 years and 2 months in mitral valve replacement[n=10], 1 year and 8 months in mitral valvuloplasty[n=4], 3 years and 10 months in open mitral commissurotomy [n=2]. The cause of reoperation in closed mitral commissurotomy was progression of the disease, and residual stenosis with progression was the cause in open mitral commissurotomy cases. Technical failure might be the cause in the cases of valvuloplasty. In prosthetic valve replacement group the causes of reoperation were primary failure. Also two cases of suggested valve thrombosis and one case of failure of tricuspid annuloplasty was noted in prosthetic valve replacement group. The used valves for reoperation were Ionescue-Shiley in 3 cases, Bjork-Shiley in 6 cases, St. Jude Medical in 2 cases and CarboMedics in 8 cases. The mortality rate was 20%[n=4] and the causes of death were low output syndrome in 1 case, multiple organ failure in 2 cases and bleeding in 1 case during sternal reentry. During follow up 1 case of sudden death was observed.

  • PDF

Changes of Microembolic Signals after Heart Valve Surgery (심장 판막 수술 후 미세색전의 변화)

  • 조수진;이은일;백만종;오삼세;나찬영
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.316-320
    • /
    • 2003
  • Background: The detection of circulating microemboli by transcranial Doppler ultrasonography (TCD) has the potential to select the patients with high risk for future symptomatic brain embolism. We prospectively evaluated the positive rate and the frequency of microembolic signals (MES) before and after the heart valve surgery (HVS). Material and Method: Fifty in-patients with heart valve disease were enrolled in this study. Patients with history of previous stroke or heart valve surgery were excluded. Two unilateral TCD monitoring sessions were peformed from middle cerebral artery for 1-hour, before and after HVS. Result: Mechanical Heart valves were implanted in 28 patients, tissue valves were implanted in 10 patients, and remaining 12 patients received mitral valve repair. Positive rate of MES was significantly increased after HVS (50%), compared to that of before HVS (8%, p=0.00). There was no relation between MES after HVS and intensity of anticoagulation, cardiac rhythm, patients' age, and history of hypertension. The positive rate of MES after implantation of mechanical heart valve (71.4%) was significantly higher than those after implantation of tissue valve or mitral valve plasty (p=0.002). Conclusion: Positive rate of MES was increased significantly after the implantation of HVS. The changes of MES in those with mechanical prosthesis may be related to the increased risk or embolism after Hvs.

Diagnostic Performance of Cardiac CT and Transthoracic Echocardiography for Detection of Surgically Confirmed Bicuspid Aortic Valve: Effect of Calcium Extent and Valve Subtypes (외과적으로 확진된 이첨 대동맥 판막의 진단을 위한 심장 CT 및 경흉부 심초음파의 진단적 성능: 판막 아형 및 칼슘의 양이 미치는 효과)

  • Jeongju Kim;Sung Mok Kim;Joonghyun Ahn;Jihoon Kim;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1324-1336
    • /
    • 2023
  • Purpose This study aimed to compare the diagnostic performance of cardiac CT and transthoracic echocardiogram (TTE) depending on the degree of valvular calcification and bicuspid aortic valve (BAV) subtype. Materials and Methods This retrospective study included 266 consecutive patients (106 with BAV and 160 with tricuspid aortic valve) who underwent cardiac CT and TTE before aortic valve replacement. Cardiac CT was used to evaluate the morphology of the aortic valve, and a calcium scoring scan was used to quantify valve calcium. The aortic valves were classified into fused and two-sinus types. The diagnostic accuracy of cardiac CT and TTE was calculated using a reference standard for intraoperative inspection. Results CT demonstrated significantly higher sensitivity, negative predictive value, and accuracy than TTE in detecting BAV (p < 0.001, p < 0.001, and p = 0.003, respectively). The TTE sensitivity tended to decrease as valvular calcification increased. The error rate of TTE for CT was 10.9% for the twosinus type of BAV and 28.3% for the fused type (p = 0.044). Conclusion Cardiac CT had a higher diagnostic performance in detecting BAV than TTE and may help diagnose BAV, particularly in patients with severe valvular calcification.