• 제목/요약/키워드: Valve System

검색결과 2,201건 처리시간 0.034초

HLA를 장착한 직접 구동형 OHC 밸브 트레인 시스템의 마찰 특성 해석 (Analysis of Frictional Characteristics of Direct-Acting OHC Valve Train System Equipped with HLA)

  • 지유철;조명래;한동철;최재권
    • 한국자동차공학회논문집
    • /
    • 제6권3호
    • /
    • pp.78-87
    • /
    • 1998
  • A dynamic model of direct-acting OHC valve train system has been used to determine the load conditions in the system. The modified equations for calculating the friction forces between cam and HLA, and at a camshaft bearing have been defined considering the lubrication conditions. Then, to understand the frictional characteristics in the system, a parameter study has been performed. As the results of the analysis, valve spring stiffness and preload have great effects on the friction in the system, but the effects of other parameters are negligible. So, how to design the valve train system with respect to the reduction of friction is to minimize the valve spring stiffness and preload in the limit of satisfying the dynamic constraints.

  • PDF

전기.유압 서보밸브를 이용한 압축가스 방출시스템의 동특성 해석 및 제어 (The Analysis of Dynamic Characteristics and the Control of Compressed Gas Expulsion System Using Electro-Hydraulic Servo Valve)

  • 김용만;김정관;한명철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.710-714
    • /
    • 2005
  • A dynamical analysis and PID control of a compressed gas expulsion system is performed. The purpose of this study is to develop a compressed gas discharging system and to verify the validity of the system. The electro-hydraulic servo valve is modeled as a 3th order transfer function to calculate flow force affecting expulsion valve is significantly considered. The friction force in the expulsion valve is considered as a nonliner model of stribeck effect. The dynamic characteristics of this system is examined by the computer simulation. The position control of the expulsion valve is performed by PID controller.

  • PDF

Modelling of Optimum Design of High Vacuum System for Plasma Process

  • Kim, Hyung-Taek
    • International journal of advanced smart convergence
    • /
    • 제10권1호
    • /
    • pp.159-165
    • /
    • 2021
  • Electronic devices used in the mobile environments fabricated under the plasma conditions in high vacuum system. Especially for the development of advanced electronic devices, high quality plasma as the process conditions are required. For this purpose, the variable conductance throttle valves for controllable plasma employed to the high vacuum system. In this study, we analyzed the effects of throttle valve applications on vacuum characteristics simulated to obtain the optimum design modelling for plasma conditions of high vacuum system. We used commercial simulator of vacuum system, VacSim(multi) on this study. Reliability of simulator verified by simulation of the commercially available models of high vacuum system. Simulated vacuum characteristics of the proposed modelling agreed with the observed experimental behaviour of real systems. Pressure limit valve and normally on-off control valve schematized as the modelling of throttle valve for the constant process-pressure of below 10-3 torr. Simulation results plotted as pump down curve of chamber, variable valve conductance and conductance logic of throttle valve. Simulated behaviors showed the applications of throttle valve sustained the process-pressure constantly, stably, and reliably in plasma process.

Simulations of Effects of Variable Conductance Throttle Valve on the Characteristics of High Vacuum System

  • Kim, Hyung-Taek;Cho, Han-Ho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.28-35
    • /
    • 2015
  • Thin film electronic devices which brought the current mobile environment could be fabricated only under the high quality vacuum conditions provided by high vacuum systems. Especially for the development of advanced thin film devices, constant high quality vacuum as the deposition pressure is definitely needed. For this purpose, the variable conductance throttle valves were employed to the high vacuum system. In this study, the effects of throttle valve applications on vacuum characteristics were simulated to obtain the optimum design modelling of variable conductance of high vacuum system. Commercial simulator of vacuum system, $VacSim^{(multi)}$, was used on this investigation. Reliability of employed simulator was verified by the simulation of the commercially available models of high vacuum system. Simulated vacuum characteristics of the proposed modelling were agreed with the observed experimental behaviour of real systems. Pressure limit valve and normally on-off control valve were schematized as the modelling of throttle valve for the constant process-pressure of below $10^{-3}torr$. Simulation results were plotted as pump down curve of chamber, variable valve conductance and conductance logic of throttle valve. Simulated behaviors showed the applications of throttle valve sustained the process-pressure constantly, stably, and reliably.

ER-Valve 작동기를 이용한 Two link Robot의 위치제어 (Two Linked-Robot Actuated by ER-Valve Systems)

  • 이호근;김휘동
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.165-170
    • /
    • 2001
  • This paper presents performance analysis of two-linked robot system using ER (electro rheological) valve actuators. An ER fluid consisting of soluble chemical starches (particles) and silicone oil is made and its field-dependent yield stress is experimentally distilled using electro-viscometer. From this result, the design parameters of ER valve are determined. Based on parameter study, an ER valve system is designed and manufactured. Furthermore, the measured pressure drop is compared with predicted one obtained from the Bingham model. Following the evaluation of field-dependent pressure drop of ER valve, a two-linked robot system with two ER valve actuators is then constructed and its governing equation of motion is derived. From this equation, PID controller is established. Consequently, control performances of the proposed two-linked robot system featuring ER valve are evaluated.

  • PDF

발전용 증기밸브 누설량 평가에 관한 연구 (Study on Evaluation of the Leak Rate for Steam Valve in Power Plant)

  • 이상국;박종혁;유근배
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.45-50
    • /
    • 2007
  • Acoustic emission technology is applied to diagnosis the internal leak and operating conditions of the major valves at nuclear power plants. The purpose of this study is to verify availability of the acoustic emission as in-situ diagnosis method. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve(main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

스풀형 압력제어밸브의 동특성 해석 (An Analysis of the Dynamic Characteristics of a Spool Type Pressure Control Valve)

  • 문강현;허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.61-66
    • /
    • 2018
  • Almost every hydraulic system is equipped with a pressure relief valve, to maintain working pressure of the system at a pre-determined level. Thus, dynamic characteristics of such a relief valve, in conjunction with other hydraulic components, are important in designing the hydraulic control system. The single stage pressure relief valve is dynamically undesirable, due to relatively low viscous damping, that causes high frequency oscillations. This problem is overcome by introducing orifices in the inner pilot line, and drain line. In this study, for the single stage spool type pressure relief valve, the system equations were derived through an adequate linearisation and several simplifications were made, to use the transfer function formulation technique. All coefficients were evaluated and used, to make some results by using Matlab software. Results of analysis are compared with experimental results. In this study, parameters affecting stability of valve design are determined and suggested relative to the design.

밸브 거동 특성 파악을 위한 hole 센서의 적용에 관한 실험적 연구 (The Experimental Study on Characteristics of Valve System using Hole Type Valve Lift Sensor)

  • 문건필;이용규;이승진;최교남;정동수;박성영
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.80-86
    • /
    • 2008
  • Recently, controlled auto ignition(CAI) in gasoline engines are drawing more attentions due to its extremely low level of NOx emissions and potentials in lowering the fuel consumption rate. The one of the key techniques for realizing CAI combustion in engines is the control of valve system. Since the valve linkage system with higher complexity, or even earn-less valve systems, such as electro-hydraulic and electro-magnetic system, are adopted in CAI engines, it is not easy to estimate the valve lift profile from earn profiles. Therefore new measurement techniques for valve lift in CAI engines have been tried and tested. In this paper, hole type valve lift sensor was developed and tested to check the applicability in CAI engines. The valve lifts could be obtained from the sensor signal, which depends on the distance from the sensor to magnet attached to valve. Various engine speeds, ranging from 2,000 to 6,000 rpm, and valve lifts, maximum up to 9.7 mm, were tested. It was found that the sensor output for valve lift had accuracy of 98% in comparison with the basic specifications of valve lift through improvements of sensor driving circuit.

IV-TAP : 밸브트레인 통합 해석 프로그램 (IV-TAP : Integrated Valve Train system Analysis Program)

  • 김지영;조명래;신흥주;한동철
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.258-262
    • /
    • 2000
  • This paper reports on the development of the analysis program of the valve train system, IV-TAP. It is essential to verify the stability of the design and to improve the performance of the system. In order to do that effi챠ently, it is required that integrated and interactive simulation analysis program. IV-TAP is developed in the base of the object-oriented, capsulation, modulization, OLE(objected linking and embedding) and variational design theory. So it contain the expandability and flexibility of the structure. In additon to that, it is programed to make the convenient user interface by using the visualization programming. It can support the modification of the valve element as well as the development of the valve system in the beginning. It is expected to reduce the money and effort for design the valve train system.

  • PDF

Responsibility of Control System of Engine Intake Valve with Linear Electromagnetic Actuator

  • Nakpipat, Tawatchai;Kusaka, Akihiko;Ennoji, Hisayuki;Iijima, Toshio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.291-295
    • /
    • 2004
  • New valve driving system to control for the best volumetric efficiency at each load of an internal combustion engine within one engine cycle has been developed. The system needs to reduce pumping loss that cause by throttle valve during the intake valve is opened. In this system the intake valve is driven by a linear DC electromagnetic actuator which is controlled by personal computer. The result is compared both installed and uninstalled actuator into the cylinder head. By both of experimental and numerical calculation, the responsibility of the valve driving system to the engine speed was examined

  • PDF