• Title/Summary/Keyword: Valve System

Search Result 2,204, Processing Time 0.028 seconds

Experimental Study of Adoption of Alternative Refrigerant for Avionic Equipment Cooling System (항공전자기기용 냉각시스템의 대체냉매 적용에 관한 실험적 연구)

  • Kang, Hoon;Jung, Jongho;Jung, Minwoo;Chi, Yongnam;Yoo, Yongseon;Choi, Heeju;Byeon, Youngman;Kim, Youngjin;Oh, Kwangyoon;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.431-439
    • /
    • 2013
  • A cooling system is adopted to control the thermal load from the avionic equipments in an aircraft for stable operation. In this study, an avionic cooling system was designed and manufactured by adopting a vapor compression cycle with a closed-loop air-circulation system to investigate the operating characteristics of an alternative refrigerant. The performance characteristics of a cooling system adopting R236fa as an alternative refrigerant were experimentally determined by varying the refrigerant charging amount, expansion valve opening, and compressor rotation speed. The experimental results were analyzed and compared with those of a cooling system adopting R124 as a refrigerant. The possibility of the adoption of R236fa as an alternative refrigerant was verified, and design solutions were suggested to improve the system efficiency.

Evaluation of Damage Range Variation Based on Operation System of Chlorine Facility in Water Purification Plant using KORA (KORA를 활용한 정수장 염소 취급시설의 운영조건에 따른 피해범위 변화 평가)

  • Kwak, Sollim;Lim, Hyeongjun;Ryu, Taekwon;Choi, Woosoo;Jung, Jinhee;Lee, Jieun;Kim, Jungkon;Lee, Yeonhee;Ryu, Jisung;Yoon, Junheon;Yoon, Yi;Lee, Jinseon
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.84-90
    • /
    • 2018
  • We researched the way to minimize the damage when the chlorine-leak accident take place in a purification plant. Since the level of risk based on the Off-site Risk Assessment(ORA) is a combination of proportional to the number of residents in the damaged area and frequency of accidents, we suggested the adequate conditions to reduce the number of residents in the damaged area by means of the operating temperature of a handling facility, installation of a emergency shut-off valve, and the analysis of the variation of the damaging range in accordance with the type of enclosure. The coverage of damage was calculated by the 'KORA(Korea Off-site Risk Assessment Supporting Tool) program. The research shows that the lower operating temperature gets, the more emergency shut-off valve being installed and the higher enclosure level of facility becomes, the extent of damage gets decreased. The decreasing rate of worst case was 17.6%, 71%, 34.5% respectively, the decreasing rate of alternative case was 31.6%, 69.0%, 34.8% respectively.

Hydrogen Compressor Cycle Analysis for the Operating Pressure of 50 MPa and High Charging Capacity (50 MPa급 대용량 수소압축기 사이클 해석)

  • Song, Byung-Hee;Myoung, No-Seuk;Jang, Seon-Jun;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.66-73
    • /
    • 2020
  • In the hydrogen compression cycle, which is currently being developed, hydrogen is compressed to a very high pressure using a compressor, and then stored and used in a high-pressure vessel. This shows that an increase in the temperature of hydrogen in the vessel due to a pressure rise during the filling process and the pressure fatigue due to the repeated cycle may cause problems in the reliability of the vessel. In this paper, for the entire processes in a 50 MPa hydrogen compression system, theoretical and numerical methods were conducted to analyze the following: the temperature increase of hydrogen in the vessel and the time required to reach thermal equilibrium with the surroundings, the change in temperature of hydrogen passing through the pressure reducing valve, and the required capacity of the heat exchanger for cooling the vessel. The results will be useful for the design and construction of hydrogen compression systems, such as hydrogen charging stations.

A Study on the Air Vent Valve of the Hydraulic Servo Actuator for Steam Control of Power Plants (발전소의 스팀제어용 유압서보 액추에이터의 공기배출 밸브에 관한 연구)

  • Lee, Yong Bum;Lee, Jong Jik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.397-402
    • /
    • 2016
  • To produce adequate electricity in nuclear and thermal power plants, an optimal amount of steam should be supplied to a generator connected to high- and low-pressure steam turbines. A turbine output control device, which is a special steam valve employed to supply or interrupt the steam to the turbine, is operated using a hydraulic servo actuator. In power plants, the performance of servo actuators is degraded by the air generated from the hydraulic system, or causes frequent failures owing to an increase in the wear of the seal. This is due to the seal being burnt as generated heat using the produced compressed air. Some power plants have exhausted air using a fixed orifice, and thus they encounter power loss due to mass flow exhaust. Failures are generated in hydraulic pumps, electric motors, and valves, which are frequently operated. In this study, we perform modeling and analysis of the load-sensing air-exhaust valves, which can be passed through very fine flow under normal use conditions, and exhaust mass flow air at the beginning stage as with existing fixed orifices. Then, we propose a method to prevent failures due to the compressed air, and to ensure the control accuracy of hydraulic servo actuators.

Study on the Safety Analysis on the Cooling Performance of Hybrid SIT under the Station Blackout Accident (발전소 정전사고 시 Hybrid SIT의 냉각성능 평가를 위한 안전해석에 관한 연구)

  • Ryu, Sung Uk;Kim, Jae Min;Kim, Myoung Joon;Jeon, Woo Jin;Park, Hyun-Sik;Yi, Sung-Jae
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.64-70
    • /
    • 2017
  • The concept of Hybrid Safety Injection Tank (Hybrid SIT) proposed by the Korea Atomic Energy Research Institute (KAERI) has been introduced for the purpose of application to the Advanced Power Reactor Plus (APR+). In this study, the SBO situation of the APR+ was analyzed by using the MARS-KS code in order to evaluate whether the operation of the Hybrid SIT has an effect on the cooling performance of the Reactor Coolant System (RCS). According to the analysis, when the actuation valve on the pressure balancing line (PBL) is opened, the Hybrid SIT's pressure rises rapidly, forming equilibrium with the RCS pressure; subsequently, a flow is injected from the Hybrid SIT into the reactor vessel through the direct vessel injection (DVI) line. The analysis showed that it is possible to keep the core temperature below melting temperature during the operation of a Hybrid SIT.

The Magnetoresistance Properties of Spin Valves with CoFe/Ru/CoFe/FeMn Synthetic Antiferromagnet (Synthetic antiferromagnet CoFe/Ru/CoFe/FeMn을 이용한 스핀 밸브 구조의 자기저항 특성)

  • Jang, S.H.;Kang, T.;Kim, M.J.;Kim, H.J.;Kim, K.Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.5
    • /
    • pp.196-202
    • /
    • 2000
  • Top synthetic spin valves with structure Ta/NiFe/CoFe/Cu/CoFe(P1)/Ru/CoFe(P2)/FeMn/Ta on Si(100) substrate with natural oxide were prepared by dc magnetron sputtering system, and investigated on the magnetoresistance properties and effective exchange bias field. As the thickness of FeMn increased above 150 $\AA$, MR ratio was decreased due to the current shunting effect. As the thickness of free layer decreased below 40$\AA$, MR ratio was reduced rapidly. In case of 40 $\AA$ thick of free layer, spin valve film with a structure Si(100)/Ta(50 $\AA$)/NiFe(27 $\AA$)/CoFe(13 $\AA$)/Cu(26 $\AA$)/CoFe(30 $\AA$)/Ru(7 $\AA$)/CoFe(15 $\AA$)/FeMn(100 $\AA$)/Ta(50 $\AA$) exhibited maximum MR ratio of 7.5 % and an effective exchange bias field of 600 Oe, respectively. Thickness difference dependence in this synthetic spin valve structure on effective exchange field was investigated and interpreted by the analytical method. It should be noted that thickness increase of CoFe(P 1) and decrease of CoFe(P2) in synthetic antiferromagnet leaded to the decrease in effective exchange bias field by experimentally and analytically.

  • PDF

Interlayer Coupling Field in Spin Valves with CoEe/Ru/CoFe/FeMn Synthetic Antiferromagnet (Synthetic antiferromagnet CoFe/Ru/CoFe/FeMn을 이용한 스핀 밸브 구조의 interlayer coupling field)

  • Kim, K.Y.;Shin, K.H.;Kim, H.J.;Jang, S.H.;Kang, T.
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.5
    • /
    • pp.203-209
    • /
    • 2000
  • Top synthetic spin valves with structure Ta/NiFe/CoFe/Cu/CoFe(P 1)/Ru/CoFe(P2)/FeMn/Ta on Si (100) substrate with natural oxide were prepared by dc magnetron sputtering system. We have changed only the thickness in free layers and the thickness difference (Pl-P2) in two ferromagnetic layers separated by Ru, and investigated the effect of magnetic film thickness on interlayer coupling field in spin valve with synthetic antiferromagnet. According to the decrease of free layer thickness, interlayer coupling field was increased due to the magnetostatic coupling(orange peel coupling). In case of t$\_$P1/>t$\^$P2/, interlayer coupling field agreed well with the modified Neel model suggested in conventional spin valve structures by Kools et al. However, in case of t$\_$P1/>t$\^$P2/, it was found that the interlayer coupling field was not explained by the Modified Neel Model and was confirmed the necessity of further remodeling. The dependence of Cu thickness on the interlayer coupling field was investigated and 10 Oe of interlayer coupling field was obtained when the Cu thickness is 32 $\AA$.

  • PDF

Magnetoresistive Properties of Array IrMn Spin Valves Devices (어레이 IrMn 스핀밸브 소자의 자기저항특성 연구)

  • Ahn, M.C.;Choi, S.D.;Joo, H.W.;Kim, G.W.;Hwang, D.G.;Rhee, J.R.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.156-161
    • /
    • 2007
  • To develop array magnetic sensors, specular-type giant magnetoresistive- spin valve (GMR-SV) film of Glass/Ta(5)MiFe(7)/IrMn(10)NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) was deposited by using a high-vacuum sputtering system. One of 15 way sensors in the area of $8{\times}8mm^2$ was Patterned a size of $20{\times}80{\mu}m^2$ in multilayer sample by Photo-lithography. All of 15 sensors with Cu electrodes were measured a uniform magnetic properties by 2-probe method. The highest magnetic sensitivity of MR and output voltage measured nearby an external magnetic field of 5 Oe were MS = 0.5%/Oe and ${\triangle}$V= 3.0 mV, respectively. An easy-axis of top-free layers of $CoFe/O_2/NiFe$ with shape anisotropy was perpendicular to one of bottom-pinned layers $IrMn/NiFe/O_2/CoFe$. When the sensing current increased from 1 mA to 10 mA, the output working voltage uniformly increased and the magnetic sensitivity was almost stable to use the nano-magnetic devices with good sensitive properties.

Slit Ventricle Syndrome in Children : Clinical Presentation and Treatment (소아에서 틈새뇌실 증후군 : 임상 양상 및 치료)

  • Shin, Beom-Sik;Yang, Kook-Hee;Kim, Dong-Seok;Choi, Joong-Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.309-315
    • /
    • 2001
  • The term slit ventricle syndrome(SVS) refers to an episodic occurrence of headache, vomiting, and possibly some degree of impaired consciousness in shunted hydrocephalic children in whom slit-like ventricles are seen on CT scan or MRI. Authors present 6 cases with SVS who were treated at our institute for last 10 years. From 1986 to 1996, 821 patients underwent shunt surgery for hydrocephalus. The etiology of hydrocephalus included brain tumor(140 patients), post-hemorrhagic(62 patients), idiopathic normotensive hydrocephalus(64 patients), post-meningitic( 58 patients), post-traumatic(54 patients), congenital(48 patients), neurocysticercosis(31 patients), and unknown etiology(364 patients). During the mean follow-up duration of 68 months, 232 shunt revisions were performed by a revision rate of 1.28 per patient. The incidence of SVS was 0.7%(6 patients). Most of them have been operated on in infancy. Time interval from the first operation to the development of slit-ventricle syndrome ranged from 4 to 8 years, the mean was 6 years. Shuntogram showed patent shunt in all patients. Two patients with less severe clinical symptoms improved with conservative treatment. These patients were not measured ICP because of good hospital course. One patient showed high ICP and needed only revision with same pressure valve as previous shunt. Low ICP was noted in 3 patients. Pressure augmentation using an anti-siphon device(ASD) or upgrading valve system were necessary in these patients. The authors stress that determining type of SVS is the first step in treatment planning and that the best treatment is a strategy aimed at resolving the specific type of SVS responsible for the symptoms.

  • PDF

Tuberous Sclerosis Complex with Crohn's Disease (크론병과 병발한 결절성경화증 1예)

  • Kim, Min Hee;Lee, Yoon Jin;Kim, Jae Young;Yi, Yoon Young;Kang, Joon Won
    • Journal of the Korean Child Neurology Society
    • /
    • v.26 no.4
    • /
    • pp.284-287
    • /
    • 2018
  • Tuberous sclerosis complex (TSC) is an autosomal dominant disorder caused by mutation of one of two genes, TSC1 (encoding hamartin, 9q34) and TSC2 (encoding tuberin, 16p13). It invades the central nervous system and various parts of the body, causing various symptoms. Crohn's disease (CD) is a chronic immune-mediated disease that has not been clearly elucidated. It is thought to be caused by an excessive immune response of the body to bacteria that normally exist in the digestive tract with genetic factors. No cases have been reported in which both of the above-mentioned diseases occurred simultaneously. We report a case of CD in a patient with TSC. A 12-year-old boy was brought to our hospital because of abdominal pain. Skin lesions were observed in the TSC. Fundus examination revealed a hamartoma in the right retina. Brain magnetic resonance imaging revealed a subendothelial giant cell astrocytoma (SEGA). On the basis of these findings, he was diagnosed as having TSC. Blood test results showed increased levels of inflammatory markers. On abdominal ultrasonography, his colon walls were observed to be thickened with increased vascularity of the proximal ascending colon, ileocecal valve, and terminal ileum. Colonoscopy revealed discontinuous ulcerations and inflammations of the ileum, IC valve, and cecum, similar to those found in CD. Everolimus was administered orally for the SEGA but was discontinued frequently owing to the exacerbation of CD. The possibility of CD should be kept in mind in patients with TSC considering to undergo treatment for SEGA.