• 제목/요약/키워드: Valve Materials

Search Result 347, Processing Time 0.025 seconds

COMBUSTION CHARACTERISTICS OF HOMOGENEOUS CHARGED METHANE-AIR MIXTURE IN A CONSTANT VOLUME COMBUSTION CHAMBER

  • CHOI S. H.;CHO S. W.;JEONG D. S.;JEON C. H.;CHANG Y. J.
    • International Journal of Automotive Technology
    • /
    • v.6 no.4
    • /
    • pp.323-332
    • /
    • 2005
  • A cylindrical constant volume combustion chamber was used to investigate the flow characteristics at the spark electrode gap and the combustion characteristics of a homogeneous charged methane-air mixture under various overall charge pressures, excess air ratios and ignition times. The flow characteristics, including the mean velocity and turbulence intensity, were analyzed with a hot wire anemometer. Combustion pressure development measured by piezoelectric pressure transducer, a flame propagation image acquired by ICCD camera and exhaust emissions measured by 2-valve gas chromatography were used to investigate effects of initial pressures, excess air ratios and ignition times on the combustion characteristics. It was found that the mean velocity and turbulence intensity had the maximum value around 200-300 ms and then decreased gradually to a near-zero value after 3000 ms and that the combustion duration was shorten and the flame speed and laminar burning velocity had the highest value under the condition of an excess air ratio of 1.1, an overall charge pressure of 0.15 MPa and an ignition time of 300 ms in the present study. The $CO_2$ concentration was proportional to the ignition time and overall charge pressure, the $CO_2$ concentration was proportional to the excess air ratio, and the UHC concentration was inversely proportional to the ignition time and overall charge pressure.

Recycling of Safety Check Valves Contaminated with Radioactivity by Chemical Decontamination (化學除染에 의한 逆止밸브의 再使用)

  • 정종헌;최왕규;원휘준;심준보;오원진
    • Resources Recycling
    • /
    • v.10 no.1
    • /
    • pp.56-65
    • /
    • 2001
  • Chemical decontamination techniques have been employed to reuse the high cost check valves contaminated with radioactivity and to reduce the radiation exposure during the inspection and maintenance work of safety injection system containing check valves. After chemical decontamination, an ultrasonic treatment was conducted to remove the fine solid particles retained in the crevices of check valves. The decontamination process conditions and the amount of chemical reagents were determined from the results of a pre-test, using the (list arm holder. The decontamination factors (DF), estimated from the activity in the solution, ranged from 14.5 to 18.5 corresponding to the activity removal of 93-95ft. The corrosion test data indicated that the general corrosion rate during a chemical decontamination-ultrasonic treatment process are low for type 304 S tainless steel, Inconel -600 and Stellite-6 materials $ (2.1\times10^{-2}$ $6.0\times10^{-2}$ and$ 1.7\times10^{-2}$ mil, respectively).

  • PDF

Predictive Factors of Sustained Sinus Rhythm and Recurrent Atrial Fibrillation after the Maze Procedure

  • Choi, Jong Bum;Park, Hyun Kyu;Kim, Kyung Hwa;Kim, Min Ho;Kuh, Ja Hong;Lee, Mi-Kyung;Lee, Sam Youn
    • Journal of Chest Surgery
    • /
    • v.46 no.2
    • /
    • pp.117-123
    • /
    • 2013
  • Background: We examined perioperative predictors of sustained sinus rhythm (SR) in patients undergoing the Cox maze operation and concomitant cardiac surgery for structural heart disease. Materials and Methods: From October 1999 to December 2008, 90 patients with atrial fibrillation (AF) underwent the Cox maze operation and other concomitant cardiac surgery. Eighty-nine patients, all except for one postoperative death, were followed-up with serial electrocardiographic studies, 24-hour Holter monitoring tests, and regular echocardiographic studies. Results: Eighty-nine patients undergoing the maze operation were divided into two groups according to the presence of SR. At the time of last follow-up (mean follow-up period, $51.0{\pm}30.8$ months), 79 patients (88.8%) showed SR (SR group) and 10 patients (11.2%) had recurrent AF (AF group). Factors predictive of sustained SR were the immediate postoperative conversion to SR (odds ratio, 97.2; p=0.001) and the presence of SR at the 6th month postoperatively (odds ratio, 155.7; p=0.002). Duration of AF, mitral valve surgery, number of valves undergoing surgery, left atrial dimension, and perioperative left ventricular dimensions and ejection fractions were not predictors of postoperative maintenance of SR. Conclusion: Immediate postoperative SR conversion and the presence of SR at the 6th postoperative month were independent predictors of sustained SR after the maze operation.

Clinical Outcomes of Thromboendarterectomy for Chronic Thromboembolic Pulmonary Hypertension: 12-Year Experience

  • Oh, Se Jin;Bok, Jin San;Hwang, Ho Young;Kim, Kyung-Hwan;Kim, Ki Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.41-48
    • /
    • 2013
  • Background: We present our 12-year experience of pulmonary thromboendarterectomy in patients with chronic thromboembolic pulmonary hypertension. Materials and Methods: Between January 1999 and March 2011, 16 patients underwent pulmonary thromboendarterectomy. Eleven patients (69%) were classified as functional class III or IV based on the New York Heart Association (NYHA) classification. Seven patients had a history of inferior vena cava filter insertion, and 5 patients showed coagulation disorders. Pulmonary thromboendarterectomy was performed during total circulatory arrest with deep hypothermia in 14 patients. Results: In-hospital mortality and late death occurred in 2 patients (12.5%) and 1 patient (6.3%), respectively. Extracorporeal membrane oxygenation support was required in 4 patients who developed severe hypoxemia after surgery. Thirteen of the 14 survivors have been followed up for 54 months (range, 2 to 141 months). The pulmonary arterial systolic pressure and cardiothoracic ratio on chest radiography was significantly decreased after surgery ($76{\pm}26$ mmHg vs. $41{\pm}17$ mmHg, p=0.001; $55%{\pm}8%$ vs. $48%{\pm}3%$, p=0.003). Tricuspid regurgitation was reduced from $2.1{\pm}1.1$ to $0.7{\pm}0.6$ (p=0.007), and the NYHA functional class was also improved to I or II in 13 patients (81%). These symptomatic and hemodynamic improvements maintained during the late follow-up period. Conclusion: Pulmonary thromboendarterectomy for chronic thromboembolic pulmonary hypertension shows good clinical outcomes with acceptable early and long term mortality.

Wear Property of SACM645 Material with DLC Coating (DLC 코팅된 SACM645 소재의 마모 특성)

  • Kim, Nam-Soek;Nam, Ki-Woo;Park, Jong-Nam;Ahn, Seok-Hwan;Kim, Hyun-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.76-80
    • /
    • 2010
  • Oil hydraulic piston pumps are being extensively used around the world, because of their simple design, light weight, effective cost, etc. An oil hydraulic pump is likely to have the serious problems of high leakage, friction, and low energy efficiency after a long period of use. In an oil hydraulic piston pump, the clearance between the valve block and piston plays an important role for volumetric and overall efficiency. In this study, the wear property of the SACM645 material with DLC coating used for a hydraulic piston pump was determined by experimentation with variable heat treatment. To investigate the effect according to the piston surface condition, five different types of specimens were prepared. The maximum tensile strengths of the QT and QT Nitration specimens had similar values of about 800 MPa, but the strains indicated a big difference. In a wear test, the wear characteristic of the DLC coating specimen was shown to be excellent. The QT, QT + IH, QT + Nitration, and matirx specimen showed similar wear characteristics. In the case of a dry condition without oil, the DLC coating specimen had good wear resistance, with no wear shown.

Study on Fatigue Property of Material for Oil Hydraulic Piston Pump (유압 피스톤 펌프 소재의 피로특성 연구)

  • Kim, Nam-Seok;Nam, Ki-Woo;Kim, Hyun-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.555-559
    • /
    • 2011
  • Oil hydraulic piston pumps are extensively used worldwide because of their simple design, light weight, and cost effectiveness. However, an oil hydraulic pump is likely to have high leakage, friction, and low energy efficiency after long-term use. In oil hydraulic piston pumps the clearance between the valve block and the piston plays an important role in the volumetric and overall efficiency. We studied the wear property of the SACM645 material used in hydraulic piston pumps via experiments with different heat treatments. We prepared three different specimens. The maximum tensile strengths of the QT and QT-nitration specimens are similar (about 820 MPa), but the strains are significantly different. However, the fatigue characteristic depended on the heat treatment.

Short-term Outcomes of Aortic Wrapping for Mild to Moderate Ascending Aorta Dilatation in Patients Undergoing Cardiac Surgery

  • Park, Ji-Young;Shin, Je-Kyoun;Chung, Jin-Woo;Kim, Jun-Seok;Chee, Hyun-Keun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.45 no.3
    • /
    • pp.148-154
    • /
    • 2012
  • Background: The adequate management of mild to moderate dilatation of the ascending aorta during cardiac operations remains controversial. In this study, we present the short-term outcomes of 90 patients undergoing ascending aortic wrapping with a Dacron graft during other cardiac operations. Materials and Methods: From March 2008 to January 2011, 90 consecutive patients underwent treatment for ascending aortic aneurysm using the external wrapping technique during the concomitant procedure. The study group consisted of 49 male and 41 female patients with a mean age of $58.7{\pm}13$years. The primary cardiac surgical procedures were coronary artery bypass grafting (CABG) in 3, aortic valve replacement in 2, and aortic valvuloplasty in 85 patients (isolated in 62 and combined with CABG or mitral valvuloplasty in 23). The ascending aorta diameter was measured using a computed tomography scan within 4 weeks after surgery, and was compared with the preoperative value. Results: The diameters of the ascending aorta wrapped with the Dacron graft were significantly reduced within a month after surgery from $46.4{\pm}4.3$ mm to $33.0{\pm}3.5$ mm (p<0.05). There was no early mortality or major surgical complication. During the mean follow-up period of $15.4{\pm}5.2$ months, there was only one late death caused by septic multiorgan failure. Conclusion: Dacron wrapping of the ascending aorta offers excellent results with very low mortality and morbidity, and it can be regarded as a safe and effective method for the treatment of moderately dilated ascending aorta in selected patients.

Chemisorption of CO on ultrathin epitaxial Ni films n Cu(001) surface

  • E.K. Hwang;J.J. Oh;Lee, J.S.;Kim, S.K.;Kim, J.S.;Kim, J.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.182-182
    • /
    • 1999
  • The chemisorption effect of CO on the Ni/Cu(001) surface was investigated using LEED(Low Energy Electron Diffraction) and EELS(Electron Energy Loss Spectrscopy0 under the UHV conditions. after mounting the Cu(001) single crystal in the UHV chamber (base pressure 1$\times$10-10Torr), a clean surface was obtained after a few cycles of repeated Ar+ ion sputtering and annealing at about 40$0^{\circ}C$. The epitaxial thin Ni films were formed on the Cu(001) by evaporation from 99.999% Ni block. The pseudomorphic growth and the orderness of the thin Ni films were monitored by c(2$^{\circ}C$2) LEED pattern. CO adlayers on Ni epitaxial thin films were prepared by dosing pure CO has through a leak valve. After CO adsorpton at room temperature, two pairs of peaks were observed by EELS, whose relative intensities are changed as the film thickness is varied and time is elapsed. These two pair of peaks are likely related to different bonding sites (-top and bridge sites) of C-Ni as well as C-O vibration. Experimental results and qualitative interpretation of the spectra wille be discussed. The possibility of using EELS in combination with probe species (CO) to investigate the nature of thin film growth is mentioned. We will report the experimental result of O2 dosage on Ni film and interaction of CO and O2.

  • PDF

Long Term Results of Right Ventricular Outflow Tract Reconstruction with Homografts

  • Kim, Hye-Won;Seo, Dong-Man;Shin, Hong-Ju;Park, Jeong-Jun;Yoon, Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.108-114
    • /
    • 2011
  • Background: Homograft cardiac valves and valved-conduits have been available in our institute since 1992. We sought to determine the long-term outcome after right ventricular outflow tract (RVOT) reconstruction using homografts, and risk factors for reoperation were analyzed. Materials and Methods: We retrospectively reviewed 112 patients who had undergone repair using 116 homografts between 1992 and 2008. Median age and body weight at operation were 31.2 months and 12.2 kg, respectively. The diagnoses were pulmonary atresia or stenosis with ventricular septal defect (n=93), congenital aortic valve diseases (n=15), and truncus arteriosus (N=8). Mean follow-up duration was $79.2{\pm}14.8$ months. Results: There were 10 early and 4 late deaths. Overall survival rate was 89.6%, 88.7%, 86.1% at postoperative 1 year, 5 years and 10 years, respectively. Body weight at operation, cardiopulmonary bypass (CPB) time and aortic cross-clamping (ACC) time were identified as risk factors for death. Forty-three reoperations were performed in thirty-nine patients. Freedom from reoperation was 97.0%, 77.8%, 35.0% at postoperative 1 year, 5 years and 10 years respectively. Small-sized graft was identified as a risk factor for reoperation. Conclusion: Although long-term survival after RVOT reconstruction with homografts was excellent, freedom from reoperation was unsatisfactory, especially in patients who had small grafts upon initial repair. Thus, alternative surgical strategies not using small grafts may need to be considered in this subset.

The Fabrication and Magnetoresistance of Nanometer-sized Spin Device Driven by Current Perpendicular to the Plane (수직전류 인가형 나노 스핀소자의 제조 및 자기저항 특성)

  • Chun, M.G.;Lee, H.J.;Jeung, W.Y.;Kim, K.Y.;Kim, C.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.61-66
    • /
    • 2005
  • In order to make submicron cell for spin-injection device, lift-off method using Pt stencil and wet etching was chosen. This approach allows batch fabrication of stencil substrate with electron-beam lithography. It simplifies the process between magnetic film stack deposition and final device testing, thus enabling rapid turnaround in sample fabrication. Submicron junctions with size of $200nm{\times}300nm$ and $500nm{\times}500nm$ 500 nm and pseudo spin valve structure of $CoFe(30{\AA})/Cu(100{\AA})/CoFe(120{\AA}$) was deposited into the nanojunctions. MR ratio was 0.8 and $1.1{\%}$, respectively and spin transfer effect was confirmed with critical current of $7.65{\times}10^7A/cm^2$.