• 제목/요약/키워드: Valve Factor

검색결과 230건 처리시간 0.03초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

유압 브레이커의 충격량 예측을 위한 모델링과 해석 (Modeling and Simulation for Predicting the Impact of Hydraulic Breaker)

  • 김성현;정재호;백동천;박종원
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.741-749
    • /
    • 2019
  • 굴삭기에 부착되는 유압 브레이커는 건물의 파괴 및 분해, 도로 포장재의 파손, 채석장에서의 암석 파단 등에 사용되고 있는 부착작업기의 일종의 건설 장비이다. 따라서 유압브레이커의 성능은 주로 충격량 및 충격 효율에 의해 평가되며, 이는 제조사 및 사용자 모두에게 중요한 요소이다. 본 논문에서는 건설 현장에서 주로 사용되는 20톤급 유압브레이커를 대상으로 상용 프로그램인 SimulationX를 사용하여 유압밸브 및 피스톤의 수압 면적 또는 작동 조건에 따라 유압 브레이커의 충격량 예측을 위한 모델링 및 해석을 진행하였다. 또한, 모델링 및 해석의 신뢰성을 확인하기 위하여 기존 실험 연구의 결과를 통하여 비교 및 검증하였다. 본 연구 결과는 제작 이전의 설계 단계에서 유압 브레이커의 충격량을 예측하고 충격량 향상을 위한 파라미터 연구에 도움이 될 것으로 본다. 또한 제조사 측에서는 본 논문의 결과를 통하여 유압 브레이커의 충격량을 미리 예측함으로서, 시행 착오 방지를 통하여 개발 시간 및 비용을 절감할 수 있을 것으로 예측한다.

$CO_2$ 흡수용 $100Nm^3$/hr급 Vortex Tube의 에너지분리 특성에 관한 실험적 연구 (An Experimental Study on the Energy Separation of the $100Nm^3$/hr Vortex Tube for $CO_2$ Absorption)

  • 김창수;한근희;박성영
    • 청정기술
    • /
    • 제16권3호
    • /
    • pp.213-219
    • /
    • 2010
  • 볼텍스튜브는 고압의 가스를 이용하여 고온 가스와 저온 가스를 분리하거나 입자상 물질의 분리에 사용할 수 있는 장치이다. 이러한 볼텍스튜브의 에너지분리 특성과 물질분리 특성을 활용하여, 연소가스로부터 $CO_2$를 흡수하는 장치의 핵심부품으로 적용할 수 있다. 본 연구에서는 $CO_2$ 흡수용 볼텍스튜브의 기본설계 자료를 구축하기 위하여 에너지분리 성능실험을 수행하였다. 설계를 위한 기초 자료를 확보하기 위하여, 볼텍스 발생기의 오리피스 직경, 노즐면적비 및 튜브의 길이가 에너지분리 특성에 미치는 영향력을 실험을 통하여 분석하였다. 결과적으로 오리피스 직경이 볼텍스튜브의 성능에 지배적인 설계인자임을 확인하였으며, 노즐면적비와 튜브길이의 영향력은 미미하였다. 오리피스 직경이 작고(Dc=0.6D), 노즐면적비가 중간 이상(AR=0.14~0.16)이며, 튜브 길이가 긴 모델(L=16D)이 저온 출구 측과 고온 출구 측의 열전달에서 가장 우수한 성능을 나타내었다. 본 연구의 결과는 $CO_2$흡수용 $100Nm^3$/hr급 볼텍스튜브의 기본설계 자료로 활용될 예정이다. 볼텍스튜브를 적용한 $CO_2$흡수 공정을 적용하면 기존의 대형 흡수탑 대비 상당한 공간과 에너지의 절감 효과가 기대된다.

돼지-염소 모델에서 신선 동결된 이종 경동맥 이식편의 시간 경과에 따른 조직병리학적 변화 (Time-related Histopathologic Changes of Fresh Frozen Vascular Xenograft in Pig-to-goat Model)

  • 장지민;김원곤
    • Journal of Chest Surgery
    • /
    • 제40권3호
    • /
    • pp.180-192
    • /
    • 2007
  • 배경: 최근 이종 심장 이식에서 이종항원 및 항체로 인한 초급성 또는 급성 거부반응이 중 또는 대구경의 혈관이나 판막에서는 일어나지 않는다는 보고들이 있다. 이는 이런 부위에서 이종 항원의 발현이 다른 부위보다 낮고 내피세포에 미치는 전단력이 크기 때문인 것으로 알려져 있다. 본 연구에서는 이들 보고를 바탕으로 돼지-염소 모델에서 중 또는 대구경의 혈관에 해당하는 경동맥을 이용한 이종 동맥 이식을 시행하고 정해진 기간 경과 후 이식편을 적출하여 이종 이식 혈관의 생체 내 중, 장기 개통성 및 조직병리학적 변화 양상을 관찰하여 이종 혈관 이식의 생체 내 장기 적합성을 알아보고자 하였다. 대상 및 방법: 10쌍의 돼지-염소 조합을 실험군으로 하여 1주, 1개월, 3개월, 6개월 및 12개월의 정해진 기간으로 나누어 각 기간마다 2마리의 돼지에서 양측 경동맥을 채취하여 얻은 4개의 경동맥편을 다른 처리를 하지 않고 $-70^{\circ}C$에서 보존한 후 2마리의 염소의 양측 경동맥에 각각 이식하였다. 보존 기간은 2일에서 7일로 대부분 7일 이내에 동물 실험을 시행하였다. 이식 후 주기적인 도플러 초음파 검사로 개통성을 평가하였고, 정해진 기간이 경과한 후에 염소에서 이식된 혈관 도관을 적출하여 관찰한 후 hematoxylin-eosin과 Masson's trichrome 염색을 시행하였다. 또한 T 임파구 표식자와 von Willebrand factor에 대한 면역화학염색을 시행하였다. 결과: 실험군 중 1주와 1년으로 정해진 2마리의 염소가 실험 과정과는 무관한 이유로 사망하였고, 나머지 8마리가 실험 종료시점까지 생존하였다. 생존한 8마리의 염소 가운데 3개월로 지정된 염소에서 일측 경동맥의 폐색이 발견되었으나 나머지 염소에서는 혈관의 개통성이 잘 유지되었으며, 동맥류를 형성한 이식편은 없었다. 정해진 기간 별로 적출하여 관찰하였을 때 혈관 문합부위는 잘 보존되어 있었고, 석회화는 관찰되지 않았다. 조직학적 검사에서 이식편의 혈관 내피세포는 이식 1주 후에는 소실되어 있었고, 1개월째에는 수용체인 염소의 내피세포로 재세포화 되는 양상을 보였다. 중막 및 외막에도 염증반응과 함께 수여자의 섬유아세포 및 근섬유아세포가 침윤되는 양상을 보였다. 재내피세포화 과정은 양측 문합 부위에서 시작하여 이식된 혈관의 중간 부위로 진행되는 양상이었으며, vWF에 대한 면역조직화학 염색을 통해 이식 후 1개월에 이식편의 전체에 걸쳐 재내피세포화가 이루어졌음을 관찰할 수 있었다. 신생 내막의 비후와 외막의 염증반응이 이식 후 3개월까지 심하였으나 그 이후에는 감소된 양상을 보였다. 이식 편에서 T 임파구 표식자인 CD3 양성인 세포들의 비율은 매우 낮았다. 결론: 신선 동결된 이종 동맥은 조직학적으로 이종 면역 반응에 큰 영향을 받지 않고 생체 내에서 장기 개통성을 유지하였다.

이차성 자연기흉 환자의 재발양상에 관한 분석 (Clinical Analysis of Disease Recurrence for the Patients with Secondary Spontaneous Pneumothorax)

  • 류경민;김삼현;서필원;박성식;류재욱;김현정
    • Journal of Chest Surgery
    • /
    • 제41권5호
    • /
    • pp.619-624
    • /
    • 2008
  • 배경: 기저폐질환이 없이 늑막하 폐기포의 파열에 의해 발생되는 원발성 자연 기흉 환자들과는 달리, 이차성 자연 기흉 환자들은 다양한 기저폐질환을 가지고 있으며, 재발의 빈도나 그에 따른 치료방침이 다르다. 본 연구는 이차성 자연기흉으로 입원치료를 시행한 환자들에 대하여 재발의 빈도 및 양상, 그리고 치료방법에 대한 결과에 대하여 알아보고자 하였다. 대상 및 방법: 2005년 3월부터 2007년 3월까지 초발한 이차성 자연기흉 환자 85명을 대상으로 치료방법, 재발양상, 재발에 영향을 미치는 인자들에 대하여 후향적으로 의무기록을 분석하였다. 결과: 이차성 자연기흉의 기저질환으로는 폐결핵이 49.4%로 가장 많았으며, 만성폐쇄성 폐질환이 27.6%였다. 평균 $21.1{\pm}6.7$개월($0{\sim}36$개월)의 추적기간 동안 40명의 환자가 재발하여 재발율은 47.1%였으며, 3회 재발율은 10.9%, 4회 재발율은 3.5%였다. 재발기간은 1년이내 재발한 경우가 70.5%였다 치료 성공율은 흥강삽관술만으로 47.6%, 흉관을 통한 흉막유착술 74.4%, 기낭절제수술 71%, Heimlich도관거치 50%로 흉막유착술의 성공율이 가장 높았다. 재발에 영향을 미치는 인자는 7일 이상의 공기누출이었다(p=0.002). 결론: 초발한 이차성 자연기흉 환자에서 7일 이상 공기뉴출이 되는 경우는 재발의 위험성이 높았다. 흉막유착술은 이차성 기흉환자의 재발방지에 유용한 치료방법이나, 앞으로 보다 많은 환자들을 대상으로 표준화된 치료지침의 개발이 필요하겠다.

무심폐기하 관상동맥우회술에서의 중등도의 허혈성 승모판막부전증의 중요성 (Long-term Influence of Mild to Moderate Ischemic Mitral Regurgitation after Off-pump Coronary Artery Bypass Surgery)

  • 홍종면
    • Journal of Chest Surgery
    • /
    • 제43권3호
    • /
    • pp.246-253
    • /
    • 2010
  • 배경: 술전 경도 및 중등도의 허혈성 승모판막 폐쇄부전증이 동반된 환자들의 무심폐순환 관상동맥 우회로 조성술을 시행한 후의 장기 예후를 추적 조사하였다. 대상 및 방법: 1996년 9월부터 2004년 3월까지 1,000명의 연속된 무심폐순환 관상동맥 우회로 조성술을 시행 받은 환자들의 데이터를 전향적으로 조사하였으며, 97%의 환자에서 추적 조사가 가능하였다. 육십칠명(6.7%)의 환자들이 수술 당시 경도 및 중등도의 허혈성 승모판막 폐쇄부전증이 동반되었다. 허혈성 승모판막 폐쇄부전증이 끼치는 영향에 대하여 수술사망율, 실제생존율 및 주요 심장 부작용이 없는 생존율 등을 비교하였다. 결과: 평균 추적 조사 기간은 $66{\pm}22$개월이었다. 허혈성 승모판막 폐쇄부전증이 동반된 환자들의 연령이 더 높았으며(p<0.001), 더 낮은 심박출량을 보였고(p<0.001) 더 많은 위험 인자들을 갖고 있었다. 여성에게 의미있게 더 많았으며(p=0.002), 수술사망율이나 술전후 심근 경색의 빈도에는 의미있는 차이는 없었다(p=0.25). 팔 년 생존율은 허혈성 승모판막 폐쇄부전증이 동반된 환자들이 더 낮았다($39.6{\pm}11.8%$ vs $76.7{\pm}2.2$, p<0.001). 하지만 동반된 위험 인자들을 교정했을 때 술전 경도 및 중등도의 허혈성 승모판막 폐쇄부전증 자체가 장기 사망률의 의미있는 위험 인자는 아니었다(p=0.42). 8년 간의 주요 심장 부작용이 없는 생존율은 허혈성 승모판막 폐쇄부전증이 동반된 환자들에서 의미있게 낮았다($53.12{\pm}12%$ vs $77{\pm}2%$, p<0.001). 위험 인자들을 교정했을 때 허혈성 승모판막 폐쇄부전증은 주요 심장 부작용이 없는 생존율(HR: 2.31), 울혈성 심기능 저하와 재발성 심근 경색에 의미있는 위험 요소이었다. 결론: 무심폐순환 관상동맥 우회로 조성술을 시행 받은 환자들 중 술전 경도 및 중등도의 허혈성 승모판막 폐쇄부전증이 동반된 경우 더 많은 술전 위험요소들을 갖고 있었다. 술전후의 사망률이나 유병율은 비슷하였으나, 장기적으로 심장 합병증의 유발율은 더 높았다

대동맥궁 단절증 수술 사망 원인과 위험인자 분석 (Analysis of the Causes of and Risk Factors for Mortality in the Surgical Repair of Interrupted Aortic Arch)

  • 곽재건;반지은;김웅한;진성훈;김용진;노준량;배은정;노정일;윤용수;이정렬
    • Journal of Chest Surgery
    • /
    • 제39권2호
    • /
    • pp.99-105
    • /
    • 2006
  • 배경: 대동맥 단절증은 드문 선천성 심기형으로 여전히 높은 수술 사망률을 보이고 있다. 이 연구에서는 사망의 원인과 위험인자를 분석하여 사망률이 높은 이 질환의 수술 결과를 향상시키기 위한 전략을 발견하고자 하였다. 대상 및 방법: 1984년부터 2004년까지 대동맥궁 단절증으로 진단 받은 42명의 환자를 대상으로 하였다. 환자의 나이, 수슬 당시의 체중, 수술 전 진단, 수술 전 PGE1의 사용여부, 대동맥궁 단절증의 형태, 수술 전 좌심실 유출로 협착의 정도, 인공심폐기 가동시간, 대동맥 겸자 시간 등을 사망 위험인자가 될 수 있는 후보 요소들로 가정하고 이에 대한 분석을 시행하였다. 결과: 14명의 수술 사망이 있었다. 사망원인은 페동맥 밴딩으로 인한 저산소증 및 이로 인하여 초래된 양심실 유출로의 협착, 감염, 승모판 역류, 장시간의 체외순환으로 인한 심근 손상, 대혈관 전위증 환자에서의 관상동맥 전위의 실패 등이었으며, 수슬 전 PGE1의 사용 여부, 인공심폐기의 보조 기간과 대동맥 결찰 시간 등이 사망과 관련된 위험인자로 분석되었다. 수술 전 좌심실 유출로의 협착 정도는 통계학적인 의미를 얻어내지는 못했지만, 협착 정도가 심할수록 사망률이 증가하는 경향을 보였다 (p-value=0.61). 결론: 이 연구에서 저자들은 수술 전 PGE1의 사용유무, 인공심폐기의 가동 시간과 대동맥 결찰 시간 등이 수술 사망을 높이는 인자임을 밝혔다. 작은 크기의 대동맥 하 좌심실 유출로는 수술 사망과 직접적인 관련은 없었지만, 수술 사망률의 증가에 따라 협착의 정도가 심해지는 소견은 보였다. 수술 전 환자 상태와 보다 짧은 수술 시간이 위험인자로 밝혀진 만큼, 수술 전 환자에 대한 적절한 처치와 정확한 수술적 전략을 통한 수술 시간 단축이 보다 나은 수술 성적을 위해서 꼭 필요하다.

좌주관상동맥 개구부 협착에서의 혈관성형술의 결과 (Outcome of Patch Angioplasty for Left Main Coronary Ostial Stenosis)

  • 강창현;나찬영;서홍주;김재현;이철;장윤희;황성욱;백만종;오삼세;김웅한;이영탁;김종환
    • Journal of Chest Surgery
    • /
    • 제37권1호
    • /
    • pp.56-63
    • /
    • 2004
  • 배경: 좌주관상동맥 개구부 협착에서의 혈관성형술은 기존의 관상동맥우회술 시행 시에 발생할 수 있는 혈류 경합과 역행성 혈류의 문제를 해결할 수 있는 방법으로 여겨지고 있다. 본 연구에서는 좌주관상동맥 혈관성형술의 수술 성적과 예후에 대한 분석을 시행하여 좌주관상동맥 혈관성형술의 수술적 효용성을 확인하고자 하였다. 대상 및 방법: 1991년 7월부터 2003년 5월까지 부천세종병원에서 좌관상동맥 개구부 협착으로 혈관성형술을 시행 받은 29명의 환자들을 대상으로 환자들의 수술 전 임상양상, 수술결과, 수술 후 관상동맥조영술과 심초음파 검사 등을 후향적으로 분석하였다. 대상 환자들의 평균나이는 53.1$\pm$12.5세였으며 남녀비는 8 : 21이었다. 여성 환자 중 12예에서는 뚜렷한 죽상 경화증의 위험인자를 확인할 수 없었다. 26예(89.7%)의 환자는 다른 원위부 관상동맥에 병변이 없는 단독 좌주관상동맥 개구부 협착 소견을 보였다. 결과: 28예의 환자에서 전방접근법을 사용하였고, 1예의 환자에서 상방접근법을 사용하였으며, 주폐동맥의 절단을 1예에서 시행하였다. 4예의 환자에서 관상동맥우회술을 동시에 시행하였다 수술 사망은 1예(3.4%)에서 발생하였으며 장기 추적관찰 결과 1예에서 외상으로 인한 만기 사망이 발생하여 5년 생존율은 91.2$\pm$6.1%였다. 수술 후 13예(44.8%)의 환자에서 17차례의 관상동맥조영술이 시행되었으며, 이 중 2예에서 첩포 원위부 협착이 발생하였고 1예에서 우관상동맥 개구부의 새로운 협착이 발생하여 3예의 경피적 중재술이 시행되었다. 1예의 환자에서 첩포 근위부 협착이 발생하여 관상동맥우회술을 시행하였다. 대상 환자들의 5년 재시술 회피율은 82.4$\pm$8.5%였다. 수술 후 1도 이하의 새로운 대동맥 폐쇄부전이 4예에서 그리고 수술 전 동반되었던 대동맥 폐쇄부전의 심화가 1예에서 관찰되었다. 결론: 본 연구에서 좌주관상동맥 혈관성형술은 좌주관상동맥 개구부의 협착에 사용될 수 있는 효과적인 수술방법임을 확인할 수 있었다. 그러나 수술 후 발생할 수 있는 혈관성형술 부위의 협착과 대동맥 폐쇄부전에 대한 면밀한 추적 관찰이 필요할 것으로 생각된다.

중등도 이상의 좌심실 기능 부전 환자에서의 관상동 우회술의 임상 분석 (Coronary Artery Bypass Graft in Patient with Advanced Left Ventricular Dysfunction)

  • 정종필;김승우;신제균
    • Journal of Chest Surgery
    • /
    • 제34권12호
    • /
    • pp.901-908
    • /
    • 2001
  • 배경 : 관상동맥 질환 환자에게 시행되는 관상동맥 우회술의 수술 성적이 많이 향상되었으나, 아직도 좌심실기능부전이 중등도 이상으로 심한 환자에서의 관상동맥 우회술은 합병증과 사망률이 비교적 높다. 최근 수술기법 및 심근보호법의 발달로 이러한 고위험군의 환자에게 내과적 보존 치료보다는 외과적 재혈관화가 환자의 증상 개선과 장기 생존율을 향상시킨다고 한다. 대상 및 방법 : 이에 저자는 1995년 1월부터 1999년 3월까지 시행한 관상동맥 우회술 843예 가운데 수술 전 좌심실 박출계수가 30% 이하인 환자 31예(4.1%)의 임상자료를 후향적으로 조사하고 수술 전후 측정한 심장 초음파상의 심박출 계수의 변화를 비교 분석하였다. 환자의 연령은 41세에서 72세 사이로 평균 60.7$\pm$2.2세였고, 남자 26예, 여자 5예였다. 수술전 위험인자로 심근경색의 과거력이 있었던 경우가 30예로 대부분이었으며, Thallium heart scan 검사에서 불가역인 심근 손상이 7예였다. 관상동맥 조영술에서 3개 혈관 병변이 26, Rentrop 분류 1도가 16례로 가장 많았다. 관상동맥 우회술 동안에 이식된 혈관의 수는 평균 4.88$\pm$0.8 개/명이었고, 전 예에서 복재정맥을 사용하였으며 내흉동맥을 동시에 사용한 경우는 20예였다 대동맥 차단 및 심실세동 시간은 평균 77.9$\pm$1.6분 이었고 인공 심폐기 가동시간은 평균 244.7$\pm$3.7분 이였으며, 관상동맥 우회술과 동시에 시행된 술식으로는 좌심실류 제거술 2예, 승모판막 성형술 2예, 대동맥 판막 치환술 1예였다. 술후 합병증은 부정맥 3예, 출혈 2예, 흉골 지연 봉합 1예였고 수술 전후의 대동맥내 풍선펌프의 사용이 11예였으며, 2예에서 사망하여 수술 사망률은 6.5%이었다. 수술 후 흉통 및 증상의 개선을 보인 경우는 29예였고 수술 후 시행한 심초음파 검사상 좌심실 박출 계수는 평균 38.5$\pm$11.6%로 술전 평균 측정치 25.3$\pm$2.3%에 비해 유의하게 증가되었다(p 0.001). 환자들의 평균 추적기간은 25.3$\pm$5.6개월이었다. 결론 : 좌심실 기능이 저하된 관상동맥 질환 환자에서 관상동맥 우회술을 시행하여 비교적 만족할 만한 결과를 얻을 수 있었으며, 추후 장기 추적 조사가 필요할 것으로 생각된다.

  • PDF

심장 수술 후 심방세동 발생의 예측 인자로서 혈중 BNP 농도 (Plasma Levels of Brain Natriuretic Peptide Predict Postoperative Atrial Fibrillation in Patients Undergoing Heart Surgery)

  • 권진태;정태은;이장훈;이동협
    • Journal of Chest Surgery
    • /
    • 제40권6호
    • /
    • pp.407-413
    • /
    • 2007
  • 배경: 혈중 BNP 농도가 심방세동 발생과 관련 있다는 여러 보고가 있다. 본 연구의 목적은 혈중 BNP 농도가 술 후 심방세동의 발생에 유용한 예견인자인지 알아보고 술 후 BNP 수치의 변화와 심방세동 발생시기 및 심방세동이 정상 동율동으로 돌아오는 시기를 알아보고자 하였다. 대상 및 방법: 2005년 1월 1일부터 2006년 2월 28일까지 개심술을 받은 환자 중 심방부정맥의 병력이 없는 82명의 환자를 대상으로 하였다. 혈중 BNP 농도 측정을 위한 혈액 채취는 술 전부터 술 후 7일째까지 매일 하였다. 술 후 심전도 검사는 퇴원 전까지 매일 시행하였다. 결과: 환자는 술 후 심방세동 발생 유무에 따라 두 군으로 나누었다. 술 후 심방세동은 26명(31.7%)에서 발생하였다. 심방세동 없는 군과 발생군 사이에 나이, 성별, 술 전 좌심실 구혈률, 고혈압, 좌심실 비대, 베타 차단제 복용 유무에 대해 통계학적인 의미 있는 차이는 없었다. 판막 수술을 받은 환자에서 술 후 심방세동의 발생이 많았다(39.3% vs 76.9%, p=0.002). 술 전 좌심방 크기는 심방세동 발생군에서 의미 있게 컸다($43.8{\pm}10.3 m$ vs $49.8{\pm}11.5 mm$, p=0.029). 술 전 혈중 BNP 농도는 심방세동 발생군에서 의미 있게 높았다($144.1{\pm}20.8 pg/mL$ vs $267.5{\pm}68 pg/mL$, p=0.034). 심방세동군에서 술 후 BNP 수치는 술 후 3일째 가장 높았고 심방세동 발생은 술 후 3일 이내가 가장 많이 발생하였고 술 후 일주일 이내 대부분 정상 동율동으로 돌아왔다. 결론: 혈중 BNP 농도의 증가는 심장 수술 후 심방세동 발생을 예측하는 데 유용한 인자이다. 심방세동 발생의 위험인자가 있는 경우 술 후 적극적으로 예방적 항부정맥제 사용을 고려해야 한다.