• 제목/요약/키워드: Valve Factor

검색결과 230건 처리시간 0.025초

모터구동 Flexible Wedge형 게이트밸브의 밸브 성능인자 Bounding Value에 대한 연구 (A Study on the Bounding Value of Valve Performance Parameters for Motor Operated Flexible Wedge Gate Valve)

  • 김대웅;유성연;박성근;이도환
    • 한국유체기계학회 논문집
    • /
    • 제10권5호
    • /
    • pp.46-53
    • /
    • 2007
  • Stem friction coefficient and valve factor are very important parameters for the evaluation of valve performance. In this study, the characteristics of stem friction coefficient and valve factor are analyzed, and thor bounding value is determined. The hydraulic testing is performed for many flexible wedge gate valves in the plant and statistical method is applied to the determination of bounding value. According to the results of this study, stem friction coefficient does not change much with differential pressure, and the bounding value of closing stroke is higher than that of opening stroke. The valve factor of valves with high differential pressure is higher than that of valves with medium differential pressure. It means valve factor is more sensitive to the differential pressure than the stem friction coefficient. Valve factor of the closing stroke is higher than that of opening stroke due to piston effect.

차압이 모터구동 Flexible Wedge형 게이트밸브의 성능에 미치는 영향 (Effect of Differential Pressure on the Performance of Motor Operated Flexible Wedge Gate Valve)

  • 김대웅;유성연
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.151-158
    • /
    • 2007
  • The mechanism of power transmission from motor torque to stem thrust and the operation characteristic of each stroke position are analyzed using the diagnostic signal, and effects of differential pressure on the performance of motor operated flexible wedge gate valve are investigated. Test facility consists of 76 mm motor operated valve(flexible wedge type), pump and pipe system. Static and dynamic test are performed separately, and two differential pressure conditions are applied in the dynamic test. To evaluate the performance of valve, test signals for the torque, thrust, current, voltage and stroke length are acquired by using UDS which is diagnosis device for motor operated valve, and each diagnostic signal is analyzed and compared. The characteristic of valve performance factors such as stem factor, rate of loading, valve factor, are evaluated, and these factors are found to be severely influenced by the fluid differential pressure.

1인치 볼 밸브 및 글로브 밸브에 대한 개도율에 따른 손실계수(k) 비교에 관한 연구 (Comparison of Loss Coefficient using 1-inch Ball and Glove Valve Opening Ratio)

  • 강창원;이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제20권9호
    • /
    • pp.63-69
    • /
    • 2021
  • This study aims to determine the flow characteristics of a one-inch small ball valve and glove valve used in industrial plants. The flow was changed through an experimental equipment, and the internal flow characteristics of the valves were compared. Considering the pressure drop, the decrease in the slope of the ball valve based on the degree of the valve opening was relatively greater than that of the glove valve; further, the slope of the glove valve was gentle while the pressure drop was high. The flow velocity of the ball valve remains consistent after the valve was opened by 70%, whereas the flow velocity of the glove valve constantly increased. The valve loss factor of the ball valve was relatively low compared with that of the glove valve. When the valve was opened by 20%, which is the beginning stage of the valve opening, the valve loss factor of the ball valve was high and gradually became low. This is a structural problem of the ball valve, and the loss factor is significant because the flow path installed at the ball valve has a considerably small area. However, the overall loss factor of glove valve is high because it has a complicated structure of flow path.

플랜트 및 선박의 액체용 우량제어밸브 설계에 관한 연구(II) (A Study on the Design of Liquid Flow Control Valves for the Pants and Ships(II))

  • 최순호;배윤영;김태한;한기남;주경인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권2호
    • /
    • pp.1-9
    • /
    • 1995
  • The processing paper has devoted to the theory of the flow equations, the basic derivative procedure, the meaning of a valve flow coefficient $C_v$, the valve Reynolds R$R_{ev}$ and its application for liquid control valves, which applicable under the condition of a non-critical flow and the case of piping geometry factor $F_p$=1.0. However there is no information on the effects of fittings, a critical flow and the flow resistance coefficient of a valve equivalent to that of pipe which is conveniently used in the piping design. Since the piping systems of plants or ships generally contain various fittings such as expanders and reducers due to different size between pipes and valves and there may occur a critical flow, that a mass flowrate is maintained to be constant, due to the pressure drop in a piping when a liquid is initially maintainder ar a saturated temperature or at nearby corresponding to upstream pressure, system designer should have a knowledge of the effect to flow due to fittings and the critical flow phenomenon of a liquid. This study is performed to inform system designers with the critical flow phenomenon of a liquid, a valve resistance coefficient, a valve geometry factor and their applications.

  • PDF

반능동형 머플러의 배기가변밸브 스프링 적정상수에 관한 연구 (A Study on the Suitable Number of the Exhaust Variable Valve Spring for Semi-active Muffler)

  • 박세종;서호철;손성만;박경석
    • 한국정밀공학회지
    • /
    • 제23권5호
    • /
    • pp.137-142
    • /
    • 2006
  • The muffler which reduce the exhaust noise and vibration from engine influence on the engine performance. Recently, exhaust variable valve has set up in the muffler controls the backpressure in the exhaust system. And the backpressure variation according to the exhaust variable valve opening has developed the engine performance. First, the preceding of structural analysis is needed and simulation experiment is requested for the study on the design factor to influence on the operation of the exhaust variable valve. In this study, setting up the various variables according to each composition element needed for the structural analysis of the exhaust variable valve, it is experimented the analysis on the influence of each design factor with the calculation of stress distribution and the displacement to cause about the backpressure for the valve through parameter study.

고차압에서 운전되는 모터구동 게이트밸브의 부하율 향상 방안 (A Method of ROL Improvement for the Motor Operated Gate Valve Operated in the High Differential Pressure Condition)

  • 김대웅;유성연
    • 한국유체기계학회 논문집
    • /
    • 제8권1호
    • /
    • pp.16-22
    • /
    • 2005
  • This paper presents the method of ROL(Rate Of Loading) improvement for the Motor Operated Gate Valve operated in high differential pressure condition. ROL is one of the most important evaluation parameters for the valve ability. It is close to correlation in stem factor (SF) and appears different value by the differential pressure of fluid. ROL and SF are analyzed by the static test and dynamic test. The obtained result show that the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of SF between static and dynamic test, stem and stem nut should be combined appropriately by the repetition test.

고차압에서 운전되는 모터구동게이트밸브의 부하율 향상 방안 (A Method of ROL Improvement for the Motor Operated Gate Valve Operating in the High Differential Pressure Condition)

  • 김대웅;박성근;홍승열;유성연
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.562-567
    • /
    • 2003
  • This paper presents the method of Rate of Loading(ROL) improvement for the Motor Operated Gate Valve operating in high differential pressure condition. The character of ROL and Stem Factor is analyzed. Static test and dynamic test were performed and acquired the diagnosis signal for the valve closing stroke. The result of this study is the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of dynamic test thread friction coefficient stem and stem nut should be combined appropriately.

  • PDF

엔진내구시험을 통한 Valve Train 수명예측에 관한 연구 (2) (A Study of Valve-train Life Time Estimate in Engine Durability Test (2))

  • 김재진;이환희;명광희;민병두
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.75-80
    • /
    • 2014
  • In previous study, make an attempt to estimate exhaust valve seat and seat-ring wear acceleration factor for engine durability test with measuring and consideration of wear mechanism. But found abnormal initial wear rate in exhaust valve seat-ring. And have to improve exhaust valve seat-ring wear rate for reliability reason, because next GDI/Turbo engine is based on this engine and GDI/Turbo engine have higher combustion pressure and higher thermal load. In this study, Trying to find the cause of abnormal wear factor, improve valve-train durability by change specification & design of parts and verify variant parts for improving durability of valve-train. And then I would like to propose a design guide line of valve-train system in a reliability point of view, besides make a complement of previous study.

원자력 발전소 모터구동밸브의 쓰러스트/토크 신호 분석 (Analysis of Thrust/Torque Signature of MOV)

  • 류호근;박성근;김대웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.613-618
    • /
    • 2001
  • For the evaluation of operability of MOV(Motor Operated Valve), the precision prediction of thrust/torque acting on the valve is important. In this paper, the analytical prediction method of thrust/torque was proposed. The design basis stem thrust calculation typically considers the followings: Packing thrust, Stem rejection load, design basis differential pressure load. In general, test results show that temperature, pressure, fluid type, and differential pressure, independently and combination, all have an effect on the friction factor. The prediction results of thrust/torque are well agrement with dynamic test results.

  • PDF

기계판막치환후의 판막음에 대한 연구 (Physical Analysis of the Prosthetic Valve Sound)

  • 조범구
    • Journal of Chest Surgery
    • /
    • 제22권4호
    • /
    • pp.589-593
    • /
    • 1989
  • The frequency spectrum of the metallic closing sound and its loudness were measured by non invasive techniques in 66 patients. They had examined a total of 7 Carbomedics valve, 10 Duromedics valve, 11 St. Jude heart valve in mitral position and 8 Carbomedics, 10 Duromedics, 20 St. Jude heart valve prostheses functioning normally in aortic position. Statistical comparison of the loudness from sound produced by the three valves in each position, the following; The Carbomedics valve has the lowest average loudness, followed by the St. Jude medical valve, and finally the Edward Duromedics valve. And we analysis the changing factor of the loudness of valve sound, only the velocity of the flow through the valve influenced to the valve sound.

  • PDF