• Title/Summary/Keyword: Value evaluation

Search Result 8,555, Processing Time 0.051 seconds

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF

The Clinical Utility of Rectal Gas Distension F-18 FDG PET/CT (공기주입 직장 확장 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.565-571
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the clinical value of rectal gas distension F-18 FDG PET/CT imaging for the differentiation of the rectal focal uptake lesions. Materials and Methods: Twenty four patients (M:F=11:13, Age $62.8{\pm}12.4$ years) underwent rectal gas distension F-18 FDG PET/CT, prospectively: initial image at 50-60 min after the intravenous injection of F-18 FDG and rectal distension image after the infusion of air through the anus. Focally increased uptake lesions on initial images but disappeared on rectal distension images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on rectal distension images, colonoscopy and histopathologic examination were performed. Results: Among the 24 patients, 27 lesions of focal rectal uptake were detected on initial images of F-18 FDG PET/CT. Of these, 7 lesions were able to judge with physiological uptake because the focal increased uptake disappeared from rectal distension image. Remaining 3 lesions were non-rectal lesions (2 lesions: rectovesical space, 1 lesion: uterine myoma). Among 17 lesions which was showed persistent increased uptake in rectal distension image, 15 lesions were confirmed as the malignant tumor (SUVmax=$15.9{\pm}6.8$) and 2 lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Conclusion: The rectal distension F-18 FDG PET/CT imaging could be an important noninvasive method for the differentiation of malignant and benign focal rectal uptake lesions including physiologic uptake.

Incidental Benign Parotid Lesions on FDG-PET: Prevalence and Clinico-pathologic Findings (FDG-PET 검사시 우연히 발견한 양성 이하선 병변: 유병율과 임상 및 병리 소견)

  • Lim, Il-Han;Lee, Won-Woo;Chung, Jin-Haeng;Park, So-Yeon;Kim, Sang-Hee;Kim, Yu-Kyeong;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.5
    • /
    • pp.359-363
    • /
    • 2007
  • Purpose: Incidental parotid lesions on F-18 FDG-PET can mimic distant metastasis of underlying malignancy. The prevalence and the clinico-pathologic findings of PET positive parotid lesions have not been known. We investigated how often incidental parotid lesions are found on clinical FDG-PET studies and what the clinico-pathologic characteristics of those parotid lesions are in the present study. Materials and Methods: We retrospectively reviewed 3,344 cases of FDG-PET which had been obtained in our hospital from May 2003 to Dec 2006. The indications of FDG-PET were: evaluation of known/suspected cancer (n= 3,212) or screening of cancer in healthy subjects (n=132). Incidental parotid lesion on FDG-PET was defined as an un-expected FDG uptake in one of parotid glands which was not primary target lesion of current FDG-PET. FDG uptake was represented by maximum standardized uptake value (maxSUV). Final diagnosis was made by pathologic analysis or clinical follow-up assessment. Results: Fifteen (0.45% = 15/3,344) incidental parotid lesions were found and they were all benign lesions. The maxSUV ranged from 1.7 to 8.6 (mean${\pm}$s.d. = $3.7{\pm}1.9$). Final diagnoses of the incidental parotid lesions were; Warthin's tumor (n=2), pleomorphic adenoma (n=1), other un-specified benign lesion (n=1), and benign lesions under bases of imaging studies (n=3) and of clinical follow-up (n=8). Conclusion: All of incidentally found parotid lesions in clinical FDG-PET studies were confirmed as benign lesions with prevalence of 0.45%. Close follow up using PET or CT might be a reasonable approach for determining the nature of incidentally found parotid lesions.

The Evaluation of Usefulness of Wide Beam Reconstruction Method on Segmental Perfusion and Regional Wall Motion in Myocardial Perfusion SPECT (심근관류 SPECT의 분절별 관류 및 국소벽 운동에서 Wide Beam Reconstruction기법의 유용성 평가)

  • Seong, Yong-Joon;Kim, Tae-Yeob;Moon, Il-Sang;Cho, Seong-Wook;Woo, Jae-Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • Purpose: The aim of this study is to identify clinical usefulness of Wide Beam Reconstruction (WBR) which is called Xpress.cardiac$^{TM}$ to confirm the agreement between segmental perfusion and regional wall motion in myocardium compared to conventional OSEM method. Materials and Methods: Subjects were separated two groups. First group was composed of 20 normal control group. Second group was composed of 10 patients (abnormal group) who had coronary artery disease. Subjects underwent myocardial perfusion SPECT ($^{201}Tl$ rest and $^{99m}Tc$-MIBI stress). Image acquisition and reconstruction were that rest stage was each step per 30, 15 seconds and stress stage was each step per 25, 13 seconds, OSEM and WBR methods were applied. Segmental perfusion and regional wall motion were applied 20-segment model of QPS, QGS algorithm in AutoQuant. Status of perfusion was composed of 5 point scoring system (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). Status of regional wall motion was also composed of 5 point scoring (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). We evaluated the agreement between conventional OSEM and WBR through automatic quantification value. Results: The agreement of rest segmental perfusion between conventional OSEM and WBR in normal patients was 99% (396/400, k=0.662, p<0.0001) and one of rest regional wall motion was 83.8% (335/400, k=0.283), the agreement of stress segmental perfusion was 95.8%(383/400, k=0.656), one of stress regional wall motion was 87.3% (349/400, k=0.390). The match rate of rest segmental perfusion in abnormal patients was 83% (166/200, k=0.605, p<0.0001) and one of rest regional wall motion was 55.5% (111/200, k=0.385), the agreement of stress segmental perfusion was 79.5% (159/200, k=0.682), one of stress regional wall motion was 63.5% (127/200, k=0.486). Conclusion: Compared to conventional OSEM, WBR method had a good agreement of segmental perfusion in myocardium in normal and abnormal groups. However regional wall motion showed meaningful low agreement. Although WBR offers high resolution and contrast ratio, it is not useful method for gated myocardial perfusion SPECT.

  • PDF

Evaluation of Carrying Capacity for Hanwoo Heifers When Fed Whole Crop Barley and Rye as Influenced by Organic Fertilizer Application and Mixed Sowing with Legumes (유기질비료 시용과 두과 사료작물의 혼파에 따른 청보리와 호밀의 생산성과 단위면적당 한우 사육능력 추정)

  • Jo, Ik-Hwan
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.32 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • This study was conducted to estimate Hanwoo carrying capacity when whole crop barley or rye as winter forage crops was grown on different applying sources (chemical fertilizer, cattle or organic fertilizer) and mixed sowing combination with hairy vetch or forage pea during the period of 2008~2010. The experimental plots within whole crop barley or rye were consisted of 7 treatments, which were non-fertilizer, chemical fertilizer (P+K), chemical fertilizer (N+P+K), organic fertilizer, cattle slurry, cattle slurry with hairy vetch, and cattle slurry with forage pea. Each plot was triplicates and experimental treatments were allocated in the randomized complete block design. For whole crop barley, annual mean dry matter (DM) and total digestible nutrients (TDN) yields were the highest in N+P+K plots, but there were no significant differences among organic fertilizer, cattle slurry and mixed sowing with legumes. The TDN and RFV were the highest in mixed sowing plots of forage pea plus cattle slurry application. As 450 kg Hanwoo heifers were fed diets included 70% whole crop barley, organic fertilizer, cattle slurry application and mixed sowing with legumes plots is capable of raising average 2.5 to 2.9 heads/ha a year. For whole crop rye, annual DM, crude protein, and TDN yields of application groups and mixed sowing treatment with legumes showed 6.69~7.13, 0.46~0.51 and 3.95~4.18 ton/ha, respectively. In case of 450 kg Hanwoo heifers fed diets included 70% forage rye, it is estimated that cattle slurry application (mixed sowing with legumes) plots can rear average 3.1~3.3 heads/ha a year. It can be concluded that, on the basis of DM yield, not only mixed sowing with legumes by applying cattle slurry rather than single sowing of whole crop barley or whole crop rye enhanced production yield and feed values, but also it could be a substitute for imported grains as dietary protein sources in the case of feeding Hanwoo.

A Study on the Applicability of Chinese Steamed Dumpling with Korean Food Stuffing - Focusing on Jiangsu Residents - (중국 만두소의 한국음식 적용가능성 연구 - 중국 강소성 지역 주민을 대상으로 -)

  • Wu, Di;Joo, Nami
    • Korean journal of food and cookery science
    • /
    • v.31 no.3
    • /
    • pp.344-351
    • /
    • 2015
  • The purpose of this study is to improve Korean food market competitiveness in China, and to develop product diversity. Therefore, the paper will discuss and analyze the feasibility of combining Korean and Chinese cuisines. The paper is based on a SPSS-analyzed survey of 255 Jiangsu residents focusing on the concept of breakfast, and the recognition of and preference for Korean food. The result showed a high level of eating out for breakfast in Jiangsu province and the expectation of many options. The respondents generally preferred porridge, steamed stuffed dumplings, noodles and other options that are relatively convenient. Korean foods such as bulgogi, samgyeopsal, tteokbokki and bibimbap generally enjoyed a high degree of recognition and preference. This study selected bulgogi, jeyukbokkeum, dakgalbi and japchae as the stuffings for steamed dumplings and an evaluation of sensory attributes including saltiness, sweetness, spiciness, and gravy was conducted using 30 professionals. Relatively high scores were recorded in all aspects. Compared with the reference product, the dumplings with Korean food stuffing achieved higher scores. As a new development and attempt, the steamed dumplings with Korean food filling evaluated during this test demonstrated feasibility and enormous market potential. The study provides a new direction and reference value for the Chinese breakfast market and for the penetration of Korean food into the Chinese market.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

A Study on the Calculation of Evapotranspiration Crop Coefficient in the Cheongmi-cheon Paddy Field (청미천 논지에서의 증발산량 작물계수 산정에 관한 연구)

  • Kim, Kiyoung;Lee, Yongjun;Jung, Sungwon;Lee, Yeongil
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_1
    • /
    • pp.883-893
    • /
    • 2019
  • In this study, crop coefficients were calculated in two different methods and the results were evaluated. In the first method, appropriateness of GLDAS-based evapotranspiration was evaluated by comparing it with observed data of Cheongmi-cheon (CMC) Flux tower. Then, crop coefficient was calculated by dividing actual evapotranspiration with potential evapotranspiration that derived from GLDAS. In the second method, crop coefficient was determined by using MLR (Multiple Linear Regression) analysis with vegetation index (NDVI, EVI, LAI and SAVI) derived from MODIS and in-situ soil moisture data observed in CMC, In comparison of two crop coefficients over the entire period, for each crop coefficient GLDAS Kc and SM&VI Kc, shows the mean value of 0.412 and 0.378, the bias of 0.031 and -0.004, the RMSE of 0.092 and 0.069, and the Index of Agree (IOA) of 0.944 and 0.958. Overall, both methods showed similar patterns with observed evapotranspiration, but the SM&VI-based method showed better results. One step further, the statistical evaluation of GLDAS Kc and SM&VI Kc in specific period was performed according to the growth phase of the crop. The result shows that GLDAS Kc was better in the early and mid-phase of the crop growth, and SM&VI Kc was better in the latter phase. This result seems to be because of reduced accuracy of MODIS sensors due to yellow dust in spring and rain clouds in summer. If the observational accuracy of the MODIS sensor is improved in subsequent study, the accuracy of the SM&VI-based method will also be improved and this method will be applicable in determining the crop coefficient of unmeasured basin or predicting the crop coefficient of a certain area.

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.

Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT (13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate changes of quantitative and semi-quantitative myocardial perfusion indices and image quality by image reconstruction methods in $^{13}N$-ammonia ($^{13}N-NH_3$) myocardial perfusion PET/CT. Materials and Methods: Data of 14 (8 men, 6 women) patients underwent rest and adenosine stress $^{13}N-NH_3$ PET/CT (Biograph TruePoint 40 with TrueV, Siemens) were collected. Listmode scans were acquired for 10 minutes by injecting 370MBq of $^{13}N-NH_3$. Dynamic and static reconstruction was performed by use of FBP, iterative2D (2D), iterative3D (3D) and iterative TrueX (TrueX) algorithm. Coronary flow reserve (CFR) of dynamic reconstruction data, extent(%) and total perfusion deficit (TPD) (%) measured in sum of 4-10 minutes scan were evaluated by comparing with 2D method which was recommended by vendor. The image quality of each reconstructed data was compared and evaluated by five nuclear medicine physicians through a blind test. Results: CFR were lower in TrueX 18.68% (P=0.0002), FBP 4.35% (P=0.1243) and higher in 3D 7.91% (P<0.0001). As semi-quantitative values, extent and TPD of stress were higher in 3D 3.07%p (P=0.001), 2.36%p (P=0.0002), FBP 1.93%p (P=0.4275), 1.57%p (P=0.4595), TrueX 5.43%p (P=0.0003), 3.93%p (P<0.0001). Extent and TPD of rest were lower in FBP 0.86%p (P=0.1953), 0.57%p (P=0.2053) and higher in 3D 3.21%p (P=0.0006), 2.57%p (P=0.0001) and TrueX 5.36%p (P<0.0001), 4.36%p (P<0.0001). Based on the results of the blind test for image resolution and noise from the snapshot, 3D obtained the highest score, followed by 2D, TrueX and FBP. Conclusion: We found that quantitative and semi-quantitative myocardial perfusion values could be under- or over-estimated according to the reconstruction algorithm in $^{13}N-NH_3$ PET/CT. Therefore, proper dynamic and static reconstruction method should be established to provide accurate myocardial perfusion value.

  • PDF