• Title/Summary/Keyword: Value discrepancy

Search Result 209, Processing Time 0.023 seconds

Analytic responses of slender beams supported by rotationally restrained hinges during support motions

  • Ryu, Jeong Yeon;Kim, Yong-Woo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2939-2948
    • /
    • 2020
  • This paper presents an analytic solution procedure of the rotationally restrained hinged-hinged beam subjected to transverse motions at supports based on EBT (Euler-Bernoulli beam theory). The EBT solutions are compared with the solutions based on TBT (Timoshenko beam theory) for a wide range of the rotational restraint parameter (kL/EI) of slender beams whose slenderness ratio is greater than 100. The comparison shows the followings. The internal loads such as bending moment and shearing force of an extremely thin beam obtained by EBT show a good agreement with those obtained by TBT. But the discrepancy between two solutions of internal loads tends to increase as the slenderness ratio decreases. A careful examination shows that the discrepancy of the internal loads originates from their dynamic components whereas their static components show a little difference between EBT and TBT. This result suggests that TBT should be employed even for slender beams to consider the rotational effect and the shear deformation effect on dynamic components of the internal loads. The influence of the parameter on boundary conditions is examined by manipulating the spring stiffness from zero to a sufficiently large value.

Evaluation of neutron attenuation properties using helium-4 scintillation detector for dry cask inspection

  • Jihun Moon;Jisu Kim;Heejun Chung;Sung-Woo Kwak;Kyung Taek Lim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3506-3513
    • /
    • 2023
  • In this paper, we demonstrate the neutron attenuation of dry cask shielding materials using the S670e helium-4 detector manufactured by Arktis Radiation Ltd. In particular, two materials expected to be applied to the TN-32 dry cask manufactured by ORANO Korea and KORAD-21 by the Korea Radioactive Waste Agency (KORAD) were utilized. The measured neutron attenuation was compared with our Monte Carlo N-Particle Transport simulation results, and the difference is given as the root mean square (RMS). For the fast neutron case, a rapid decline in neutron counts was observed as a function of increasing material thickness, exhibiting an exponential relationship. The discrepancy between the experimentally acquired data and simulation results for the fast neutron was maintained within a 2.3% RMS. In contrast, the observed thermal neutron count demonstrated an initial rise, attained a maximum value, and exhibited an exponential decline as a function of increasing thickness. In particular, the discrepancy between the measured and simulated peak locations for thermal neutrons displayed an RMS deviation of approximately 17.3-22.4%. Finally, the results suggest that a minimum thickness of 5 cm for Li-6 is necessary to achieve a sufficiently significant cross-section, effectively capturing incoming thermal neutrons within the dry cask.

Comparison of Fine Needle Aspiration Cytologic Diagnoses and Histologic Diagnoses in 256 Breast Lesions (유방 병변 256례의 세침흡인 세포학적 진단 및 조직학적 진단과의 비교연구)

  • Kang, Mi-Seon;Jung, Soo-Jin;Yoon, Hye-Kyoung
    • The Korean Journal of Cytopathology
    • /
    • v.8 no.2
    • /
    • pp.120-128
    • /
    • 1997
  • Fine needle aspiration cytology of breast lesion is well known as a simple, economic and effective diagnostic modality. For the evaluation of cytohistologic correlation, 256 cases of cytologic smears and subsequent histologic sections during 2-year period from Jan. 1995 to Dec. 1996 were reviewed. 1. Fifteen cases(5.9%) were proven as insufficient for evaluation, and 13 of them were fibrocystic change histologically. One case of carcinoma exhibiting sufficient amount of aspirates with no malignant cells on smear was regarded as inadequate. 2. Cytohistologic correlation of 240 cases revealed sensitivity 87.0%, specificity 100.0%, positive predictive value 100.0%, negative predictive value 97.0%, false positive rate 0.0% and false negative rate 13.0%. Total diagnostic accuracy is 95.7%. 3. Total 6 cases of negative were due to small amount of aspirates containing scantiness of malignant cells in two and underestimation in four. 4. Diagnostic concordance rates of fibrocystic change and fibroadenoma were 95.5% and 80.0%, respectively. Diagnostic discrepancies were noted in 7 cases of fibrocystic change and 6 cases of fibroadenoma, however, cytologic discrimination of two entities was not easy in seven of them. 5. In a case of phyllodes tumor and a case of duct ectasia, the discrepancy was due to targeting error. Other three cases(lymphoma, adenomyoepithelioma and granulomatous mastitis) were misinterpreted because of poor acquaintance with those entities. Diagnostic accuracy of fine needle aspiration cytology of breast lesions are relatively high. However, good technique on aspiration and adequate interpretation are necessary to reduce the false negative rate and the discrepancy between cytologic and histologic diagnoses.

  • PDF

A STUDY ON THE PHYSICAL CHARACTERISTICS OF THE THREE COMMONLY USED DIE SPACING MATERIALS (여러 가지 Die spacing material의 물리적 성질에 대한 연구)

  • Moon, Hong-Seok;Kim, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.640-650
    • /
    • 1999
  • As an optimal quality of the restorations, there should be a least amount of seating discrepancy between the casting and abutment teeth. However, high viscosity of the cementing medium and its resulting thickness may prevent complete seating of the restoration. The use of die spacing material provides adequate internal relief for the cementing medium. The purpose of this study is to compare the thickness of three commonly used die spacing materials. Materials and Methods: Stone plates were fabricated and divided into 12 sections to be painted with die spacers. Tru-Fit, Whip-Mix and Belle do St. Claire die spacer which are commonly used in dental practice were tested in this study. Each die spacers were painted layer by layer according to the manufacturer's recommendation. The average thickness of each die spacers were measured with light microscope(${\times}100$) and compared between them. Results and Conclusions. A silver-colored Tru-Fit die spacer has the lowest value of thickness without statistical significance comparing with a gold-colored Tru-Fit die spacer and a gray layer of Whip-Mix die spacer has the highest value of thickness without any statistical significance comparing with Belle de St. Claire die spacer. Three and four layers of Tru-Fit die spacer and two layers of Whip-Mix and Belle de St. Claire die spacers seem to be in the acceptable range of thickness of 25 to $45{\mu}m$ for optimal seating of the restorations. The standard experimental design and method should be fur thor evaluated for more consistent and objective results.

  • PDF

Real Interest, Real Estate Prices and Monetary Policy (실질금리, 부동산가격과 통화정책)

  • Cho, Dongchul;Sung, Myung-Kee
    • KDI Journal of Economic Policy
    • /
    • v.26 no.1
    • /
    • pp.3-33
    • /
    • 2004
  • This paper investigates the effects of inflation on real estate prices, particularly the discrepancy between the sales and chonsei prices of housing, in an economy in which real interest rates are secularly declining due to the fall in capital productivity. When real interest rates fall, real estate prices rise relative to chonsei prices, and thus the well-known adverse effect of inflation, or the discrepancy between the value of financial assets (or chonsei principal) and the value of real assets (or real estate), is aggravated although the monetary authority maintains the same rate of inflation. This theoretical prediction can help explain the trend of the ratio of apartment sales prices to chonsei prices. That is, the stabilization of inflation relative to real interest rates appears to have contributed to the secular stabilization of this ratio in the 1990s, while the fall in real interest rates appears to have led to the rise of this ratio since 2001.

  • PDF

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

The Comparison of the Unconditional and Conditional Exact Power of Fisher's Exact Tes

  • Kang, Seung-Ho;Park, Yoon-Soo
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.5
    • /
    • pp.883-890
    • /
    • 2010
  • Since Fisher's exact test is conducted conditional on the observed value of the margin, there are two kinds of the exact power, the conditional and the unconditional exact power. The conditional exact power is computed at a given value of the margin whereas the unconditional exact power is calculated by incorporating the uncertainty of the margin. Although the sample size is determined based on the unconditional exact power, the actual power which Fisher's exact test has is the conditional power after the experiment is finished. This paper investigates differences between the conditional and unconditional exact power Fisher's exact test. We conclude that such discrepancy is a disadvantage of Fisher's exact test.

Visibility of Transportation in Global Logistics Environment (Global Logistics환경에서의 Visibility 확보방안)

  • Lee, Sang-Min;Jeong, Jae-Hun;Hwang, Jong-Ha
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.222-229
    • /
    • 2003
  • In the process of global transportation, many value chains which have different business process, system and technology level respectively are connected to each other. To obtain end-to-end visibility of transportation, these kind of discrepancy has to be solved appropriately. In this paper, the realization of global visibility is discussed in three point of view such as 'Data Sourcing', 'System integration' and 'System Operation'. First, the data sources of global visibility are described especially from the point of enterprise applications view, and then system integration is presented using various current e-commerce technologies for example XML, EDI and so on. Finally, flexible operation of visibility function is suggested which satisfies different goals of each value chain.

  • PDF

In-situ Structure Modification of W powder Skeleton and related Cu Infiltration Kinetics in W-Cu (W-Cu 계에서 W 분말골격의 in-situ 구조 변화와 Cu의 용침 kinetics)

  • 이재성
    • Journal of Powder Materials
    • /
    • v.6 no.1
    • /
    • pp.36-41
    • /
    • 1999
  • The present work has attempted to investigate the dependence of Cu infiltration kinetics on in-situ structure modification of W powder skeleton in W-Cu system. In-situ structure modification of W skeleton by addition of 0.3wt%Ni-P eutectic alloy was designed to proceed during heat-up of the W compact for Cu infiltration process. It was found that the Ni-P added W skeleton underwent remarkable stucture change only during heating-up. its structure was composed of large necks of W particles above 0.5 in the ratio of neck to particle size and smooth pore channels. The infiltration experiment showed that the infiltration kinetics for the W-Ni-P followed well the linear relationship of h vs. $t^{1/2}$ the rate constant K of which was in good agreement with the theoretical value. On the other hand, in case of the pure W skeleton a lower K value by 20% than the theoretical one was obatined. Such discrepancy is discussed in terms of skeleton structure induced infiltration mechanics.

  • PDF

The Study on Marginal discrepancy of Manufactured Coping Crown according to Production method and materials by using CAD/CAM System (CAD/CAM System을 활용하여 제작된 Coping Crown의 제작방식 및 재료에 따른 변연 적합도에 관한 연구)

  • Lee, Hee-Sung;Shin, Seong-Hun;Song, Joon-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.448-453
    • /
    • 2017
  • The purpose of this study was to compare the marginal discrepancy of coping crowns according to manufacturing method and materials by using the CAD/CAM system to compare the optimum manufacturing method and materials. The coping crowns were fabricated by using manufacturing methods and materials, and marginal fit was measured using the replica technique. For comparative analysis of manufacturing methods and materials, analysis of variance was performed. One-way ANOVA was performed to compare and analyze different mean values. For the milling method of the alloy, 114.6 was obtained for the MM group, 111.4 for the MS group, 67.2 for the MSC group, and 50.9 for the MSS group, respectively, using the milling/sintering method. In the milling/sintering method of ceramic, 35.6 and 36.3, respectively, were obtained for the SLME group and SLMR group, respectively. However,there was a significant difference according to the material. The milling/sintering method of the ceramic material gave the lowest value, and it was verified by the optimal method. However, marginal discrepancy of coping crowns fabricated using the CAD/CAM system is applicable to the clinic since it corresponds to acceptable numerical values in clinical practice.