• 제목/요약/키워드: Vacuum test

검색결과 1,001건 처리시간 0.044초

Vacuum Test of Cavity with Liquid Nitrogen

  • Choi, Suk;Park, Gunn-Tae;Kim, Heetae
    • Applied Science and Convergence Technology
    • /
    • 제24권5호
    • /
    • pp.132-135
    • /
    • 2015
  • Schematic of RAON vacuum system is introduced. Vacuum test for superconducting cavity with liquid nitrogen is performed. Schematic plan for RAON vacuum system is introduced and vacuum control system for superconducting cavity test is constructed. Vacuum pressure of cavity is shown as a function of pumping time. The temperature of cavity is shown as a function of cooling time. Outgassing species from cavity is also detected. Detailed experimental procedure is presented to test the cavity vacuum with liquid nitrogen.

고고도 우주환경모사용 터보분자펌프 진공설비 구축 (Development of Turbo Molecular Pump Vacuum Facility for High Altitude Space Environment Test)

  • 허환일;김민재;김성수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.827-829
    • /
    • 2011
  • 인공위성이나 우주발사체를 개발하기 위해서는 지상에서 우주환경 성능 시험이 필요하며 이를 위해서 고고도 환경을 모사할 수 있는 진공설비가 요구된다. 본 연구에서는 터보 분자 펌프를 이용하여 목표 진공도 $1.0{\times}10-6$ torr를 유지함으로써 200 km의 고도를 모사하기 위한 진공설비를 구축하고 터보 분자 펌프 장치를 구축하여 예비 진공도 성능 실험을 수행하고 보고하였다.

  • PDF

전자빔 가공기의 진공제어 밸브설계 및 특성평가 (Design and Performance Test of Vacuum Control Valve for Electron Beam Lithography)

  • 이찬홍;이후상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.777-780
    • /
    • 2005
  • The high vacuum in a electron beam lithography is basic condition, because electron beam vanish by collision with air molecules in generally atmosphere. To make high vacuum state, the vacuum control valve is essential. Most vacuum control valve are manual units. So, user of manual vacuum valve must have understanding vacuum process to change from low vacuum to high vacuum state. The user of electron beam lithography are troubled with operation of manual vacuum valve, in case the vacuum chamber is frequently open. In this paper, the design and performance test of auto vacuum control valve for electron beam lithography are described. With the auto vacuum control valve, the high vacuum level can reach 2.8E-5 Torr.

  • PDF

인공위성 탑재품 수준 열진공 시험에 대한 열해석 모델의 개발과 환경시험 결과를 이용한 검증 (Development and Verification of Thermal Analysis Model for Thermal Vacuum Test of Satellite Components)

  • 김상호;서현석;유재호;한은수;김태경;김형동;허환일
    • 한국항공우주학회지
    • /
    • 제38권8호
    • /
    • pp.842-847
    • /
    • 2010
  • 본 연구는 인공위성 탑재품 열진공 시험시 적용된 열환경 조건, 탑재품 시험용 열진공 챔버의 형상, 위성체 내부의 열환경들을 고려하여 열진공 시험 과정을 모사하는 수치해석모델을 설계하여 열해석을 수행하였다. 피시험체인 탑재품과 열진공 챔버 구성요소의 시간에 따른 온도 변화를 보여주는 과도적(Transient) 해석 결과를 구할 수 있다. 열해석에 의한 성능향상 설계를 반영하여 업그레이드한 열진공 챔버를 이용한 탑재품 환경시험을 수행하였으며, 시험 결과와 열해석 결과에 대한 비교/검증을 수행하였다.

배전급 옥내용 진공차단기의 신뢰성평가 (Reliability Assessment on the Indoor Vacuum Circuit Breaker Used in Distribution System)

  • 김민규;김맹현;신영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.160-163
    • /
    • 2003
  • This paper represent a test method for the reliability assessment on the indoor vacuum circuit breakers used in the distribution system by an accelerated life test. In order to guarantee the lifetime in service of the vacuum circuit breaker, additional test methods are suggested. Multiple closing-opening operation test under no load condition as a mechanical endurance test and a check of the quality in the vacuum interrupter are adopted to assure the long-term reliability of the vacuum circuit breaker.

  • PDF

아크쉴드가 없는 진공인터럽터의 유한요소해석 및 뇌임펄스 성능 (Simulation and Light Impulse Test Results of Shieldless Vacuum Interrupter)

  • 윤재훈;김성일;김병욱;문기림;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.45-45
    • /
    • 2010
  • This paper discusses the simulation and LI(light impulse) test of the shieldless vacuum interrupter concept. The shields of vacuum interrupter play an important role in absorbing the metal vapor. But shield distort the electric field distribution of inner vacuum interrupter. Therefore, the insulation efficiency will improve. if shield of vacuum interrupter inside does not exist. As a result, FEM simulation show that improve distribution of electrical field and equi-potential line. But LI test result dissimilar to FEM simulation result. Shieldless vacuum interrupter model lower BIL(breakdown impulse light) than vacuum interrupter have installed shield. Because conditioning process occurred metal vapor. This paper compared that FEM analysis and LI test of installed shield model and shieldless model.

  • PDF

청소기모터의 가속수명시험설계 (Accelerated Life Test Design for Vacuum Cleaner Motors)

  • 이기화;윤원영
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권1호
    • /
    • pp.47-58
    • /
    • 2009
  • In this paper, an accelerated life test procedure for a vacuum cleaner motor is proposed. We investigate the failure mechanism of the motor and select some accelerating factors and determine the orifice size as a key accelerating factor. Three stress levels of orifice size are tested and the failure data with censored data are analyzed. The modified accelerating test will reduce the test time in design phase by using the accelerating factor.

  • PDF

충남대학교 고고도 우주환경모사 진공실험 장치 (Vacuum Facility at the CNU for High Altitude Space Environment Test)

  • 신강창;이민재;정성철;김연호;김혜환;허환일
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.49-52
    • /
    • 2007
  • 마이크로 인공위성에 적용 가능한 마이크로 추력기를 개발하기 위해서는 우주환경을 모사할 수 있는 진공설비가 요구된다. 본 논문에서는 $10^{-5}$ torr의 진공도를 유지할 수 있는 진공설비를 구축하였고, 이 장비는 $100{\sim}120km$의 고도를 모사할 것으로 기대된다. 실제 장비운용에 앞서 사용할 펌프의 성능을 예측하고 저진공 펌프를 작동시켜 이론에 의한 예상 진공도와 실험을 통한 진공도를 비교 분석하였다.

  • PDF

가속열화시험을 적용한 MEMS 진공패키지의 신뢰성 분석 및 개선 (Reliability Assessment and Improvement of MEMS Vacuum Package with Accelerated Degradation Test (ADT))

  • 최민석;김운배;정병길;좌성훈;송기무
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제3권2호
    • /
    • pp.103-116
    • /
    • 2003
  • We carry out reliability tests and investigate the failure mechanisms. of the wafer level vacuum packaged MEMS gyroscope sensor using an accelerated degradation test. The accelerated degradation test (ADT) is used to evaluate reliability (and/or life) of the MEMS vacuum package and to select the accelerated test conditions, which reduce the reliability testing time. Using the failure distribution model and stress-life model, we are able to estimate the average life time of the vacuum package, which is well agreed with the measured data. After improving several package reliability issues such as prevention of gas diffusion through package, we carry out another set of accelerated tests at the chosen acceleration level. The results show that reliability of the vacuum packaged gyroscope has been greatly improved and can survive without degradation of performance, which is the Q-factor in gyroscope sensor, during environmental stress reliability tests.

  • PDF

시험 데이터 기반 소형 열진공챔버 시스템 식별에 관한 연구 (A Study on System Identification of Small Thermal Vacuum Chamber Based on Test Data)

  • 박성욱;김승균
    • 한국항공우주학회지
    • /
    • 제49권5호
    • /
    • pp.407-415
    • /
    • 2021
  • 인공위성의 부품은 발사 전 지상에서의 우주 궤도환경 하에서의 성능검증이 필수적이다. 본 논문은 열진공시험을 위한 위성 부품 및 소형 열진공챔버 간의 전도, 복사, 열손실 및 내부 발열의 열환경을 고려한 모델식을 설계하였다. 최근 한국항공우주연구원에서 수행된 열진공시험 20건의 시험데이터를 이용한 시스템 식별을 수행하였다. 시험품 기능시험의 발열이 일정하지 않는 경우를 제외하고 시스템 식별의 정확성을 확인함으로써 개발된 모델식이 유효함을 검증하였다.