• Title/Summary/Keyword: Vacuum Tank

Search Result 69, Processing Time 0.02 seconds

Thermal analysis of a LH2 storage for vehicles (자동차용 액체수소 저장 용기의 열해석)

  • Oh, Byeong Soo;Jung, Jin Sam
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.10 no.3
    • /
    • pp.151-157
    • /
    • 1999
  • The development of hydrogen vehicles has been actively progressed in the developed countries such as U. S., Japan and Germany. The most important technology of using hydrogen fuel is to develope a compatible storage tank with respect to the fossil fuel tank. Among many storage methods, the liquid hydrogen is the most desirable state because of the lowest volume and weight. The metal hydride tank is too heavy and the compressed hydrogen tank is too bulky. Because of these reasons, it is the principal purpose to analyze the theoretical heat transfer for designing and manufacturing an actual $LH_2$ tank. The insulation methods of the room between inner and outer vessel are non-vacuum, vacuum, vacuum with MLI(Multi-Layer Insulation). According to the results of the numerically calculated heat leak through the walls of the $LH_2$ tank, the vacuum insulated tank has 20 times and the MLI tank has 5616 times less heat leak than the non-vacuum tank.

  • PDF

Development of Vacuum Refueling Process for Fuel Tank (연료탱크 진공주유절차 개발)

  • Park, Jeong-Bae;Min, Seong-Ki;Lee, Se-Young;Kim, Young-Sin;Lee, Jong-Chul;Jang, Ki-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.385-390
    • /
    • 2011
  • The air remained in the fuel tank could cause oxidation of fuel during storage, and it also reduce the fuel transfer performance. To find better procedure for refueling of aircraft fuel tank, the vacuum refueling process was proposed to reduce air in the fuel tank. In this study, the vacuum refueling process established and tested, it could be helpful to find out what happened during vacuum refueling. Also the revised vacuum refueling processes were proposed to reduce the remained air and refueling time for aircraft fuel tank.

  • PDF

Development of Vacuum Refueling Process for Fuel Tank (연료탱크 진공주유절차 개발)

  • Park, Jeong-Bae;Min, Seong-Ki;Lee, Se-Young;Kim, Young-Shin;Lee, Jong-Chul;Jang, Ki-Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.3
    • /
    • pp.80-85
    • /
    • 2011
  • The air in the fuel tank could cause oxidation of fuel during storage, and it also reduced the fuel transfer performance. To find better procedure for refueling of aircraft fuel tank, the vacuum refueling process was proposed to reduce the air in the fuel tank. In this study, the vacuum refueling process was established and tested, it could be helpful to find out what happened during vacuum refueling. Also the revised vacuum refueling process was proposed to reduce the air and refueling time.

Characteristics of Cooling Down in the Enclosed Vacuum Tank by Water Driving Ejector (수 이젝터를 이용한 밀폐형 진공탱크내의 온도저감 특성)

  • Kim, Se-Hyun;Shin, You-Sik;Bae, Kang-Youl;Lee, Youn-Whan;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.700-705
    • /
    • 2003
  • The general cooling tower is a device for making a cooling water in refrigerant condensers or industrial process heat exchangers. The present cooling tower have defects with noises, complicated structure and environmental problems. In this paper, we constituted a new water cooling system by using a evaporating latent heat in an enclosed tank, and this system is consisted of an enclosed vacuum tank and water driving ejector system. Several experimental cases were carried out for improvement methods of high vacuum pressure and water cooling characteristics. The ejector performance was tested in case of water temperature variations that flows in the ejector. Based on the vacuum pressure by water driving ejector, the water cooling characteristics were investigated for the vaporized air condensing effects.

  • PDF

Weldment Design of Supports for Cryogenic Storage Tank considering Insulation (단열을 고려한 초저온 액체질소 저장 탱크의 지지대 용접부 설계)

  • Choi, Dong-Jun;Oh, Jung-Taek;Jung, Jae-Hyun;Cho, Jong-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.131-136
    • /
    • 2008
  • The double-walled steel vessel with powder insulation in the space between the walls is used to minimize heat transfer by radiation and conduction in cryogenic storage tank. The vacuum required the insulation is much less extreme than with high-vacuum or multilayer insulations. The solid supports are used to bear the weight of the inner container. Thermal and structural analysis of the tank have been carried out to study the effect of vacuum and weldment geometry of the internal supports. Heat flux in wall is increased with increasing of thermal conductivity of perlite. Heat flux and stress of support is not affected by weldment geometry.

Thermal analysis of LNG storage tank for LNG bunkering system (LNG 벙커링용 고효율 LNG 저장탱크 열해석)

  • Yun, Sang-kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.876-880
    • /
    • 2015
  • In 2016, the IMO's new rules for an 80% reduction in NOx emissions in newly built ships will necessitate the use of LNG as a clean fuel. So far, the developed European countries have led the development of LNG bunkering ships and related facilities. An LNG bunkering system stores LNG in a horizontal or vertical IMO "C"-Type tank insulated with perlite powder, and a vacuum in the annular space between the double walls, like the cryogenic liquid nitrogen tank. Current storage tanks have high heat leakage, evaporating over 2.0% daily, and are difficult to build with the required vacuum. A more efficiently insulated storage tank could reduce the evaporation rate. This research carried out thermal analysis on a new effective insulation method that separates high vacuum in the annular space between two tanks with a solid insulation material, such as urethane foam, lining the outer vessel. This highly efficient insulation system obtained an evaporation rate of 0.03% per day under a $10^{-3}torr$ vacuum, and an evaporation rate of 0.11% at $10^{-45}torr$. Even if the space loses its vacuum, the new insulation system showed a lower evaporation rate of 4.12% than the present perlite system of 4.9%. This newly developed tank can increase the efficiency of LNG storage tank and may help keep LNG bunkering systems safe.

Thermal Analysis on the LNG Storage Tank of LNG Bunkering System Applied with Double Shield Insulation Method (LNG 벙커링용 이중 단열적용 LNG 저장탱크 열해석)

  • Jung, Il-Young;Kim, Nam-Guk;Yun, Sang-Kook
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.1-6
    • /
    • 2018
  • An LNG bunkering system stores LNG in a horizontal IMO's C-Type tank insulated with perlite powder, and $10^{-2}$ Torr vacuum in the annular space between the double walls. Current storage tanks have high heat leakage, evaporating over 2.0% daily. A more efficiently insulated storage tank reducing the evaporation rate is required to develope. This research carried out thermal analysis on a new effective insulation method, i.e. double shield insulation system, that separates high super vacuum in the annular space between two tanks with a perlite vacuum in the back side of outer tank. This highly efficient insulation system obtained an evaporation rate of 0.16% per day under a $10^{-4}$ Torr vacuum. Even if the space loses its vacuum, the new insulation system showed a lower evaporation rate of 5.23% than the present perlite system of 4.9%.

Insulation Performance and BOR of Pressurized Large-capacity Liquid Hydrogen Storage Tank (가압식 대용량 액체수소 저장탱크의 단열 성능과 BOR)

  • HEUNG SEOK SEO;YEONGBUM LEE;DONGHYUK KIM;CHANGWON PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.6
    • /
    • pp.650-656
    • /
    • 2023
  • In order to efficiently control boil-off rate of a liquefied hydrogen tank, the important thing is to maintain an appropriate vacuum level. however, compared to small and medium-sized storage tank, it is very difficult to create and maintain vacuum in large-capacity storage tanks. In this study, we aim to determine the target level of future large-capacity storage tank technology development and secure basic data on performance test methods by analyzing the corelation between evaporation gas and thermal conductivity of liquefied hydrogen storage tanks.

A Study on Design of Vacuum Silo for Batch Treatment System for Dredged Soil (준설토 일괄처리시스템을 위한 진공사이로 설계에 관한 연구)

  • Kim, Yong-Seok;Yang, Hae-Rim;Kim, Hac-Sun;Jeoung, Chan-Se;Yang, Soon-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.571-577
    • /
    • 2012
  • In this study, a small movable batch treatment system for dredging soil deposited in a rain water tube is proposed; further, a vacuum silo sorting separation device with a vacuum silo, first-stage sorting separator, and conveyor is designed. The vacuum silo sorting separation device also consists of a storage tank, transferring screw, vacuum gate, screen bar, screen bar cleaner, and vacuum discharging device. In view of the fact that the flow of drawn air in the storage tank is a major factor influencing the sorting separation performance, the optimum shape of the tank is determined by CFD flow analysis. In addition, by using CAE structure analysis, the safety of a storage tank made of boards is examined. The specifications of the vacuum silo sorting separation device are determined by conducting mechanical and dynamic simulations of the driving mechanism of the vacuum silo sorting separation device through 3D-CAD modeling. Following this study, we will design a drum-screen-type second sorter, a decanter-type dehydration device, and waste water tank and pump as a secondary device. Further, on the basis of this design, we will construct a prototype model and carry out a field test.

Dynamic Response of the System for Vacuum Pump Performance Evaluation (진공 펌프 성능 평가 계통의 동적 응답)

  • Sim, Woo-Gun;Lim, Jong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1359-1367
    • /
    • 2004
  • The demand of vacuum pump has been increased in the process of semi-conduct manufacturing, as a core component. The response of the system for vacuum pump performance test can be utilized to assess the system and to obtain the reliability of the apparatus for the test. The system consists of gas supply tank, pressure chamber, measurement chamber and transmission line. Transient analysis for compressible fluid has been conducted to evaluate the dynamic characteristic of the volume terminated transmission line. Numerical approach based on the method of characteristics is used for the analysis. The response is evaluated with the important parameters for the system: i.e., length and diameter of the line, volume of the terminal tank. Using the numerical results, pumping speeds are calculated and then compared to the experimental results.