• Title/Summary/Keyword: VXI

Search Result 13, Processing Time 0.02 seconds

The Design of Multiplexing Data Acquisition System for Multi Channel Bio-magnetic Signal (다채널 생채 자기 신호의 다중 데이터 획득 시스템 설계)

  • Chang, Won-Suk;Jeon, Chang-Ik;Huh, Young;Jin, Seung-Oh;Kim, Ki-Uk;Lee, Hyun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.515-518
    • /
    • 2003
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. In this paper, we have designed the multiplexing data acquisition system for multichannel bio-magnetic signal measurement. The system consists of VXI rack which is organized MUX and AD board, Industrial rack which is mounted single board computer and DSP board. This system enable to realtime monitoring of multichannel data simultaneously. The number of channel could be increased simply added each module and firmware could be upgraded easily using host port interface of DSP.

  • PDF

Vibration Characteristic of a Cylindrical Rod according to the Mounting Locations on the Grid Support Structure (격자 지지구조체에 묶여있는 실린더 형 봉의 삽입위치에 따른 진동특성)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam;Kim, Jae-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.515-518
    • /
    • 2006
  • A vibration test for a cylindrical rod inserted on the grid support structure was tested using the sine sweep excitation method with closed loop force control. The effect of the mounting location of a test rod on the vibration characteristics of a rod continuously supported by the full size($16{\times}16$) grid support was identified. An electromagnetic vibration shaker, non-contact displacement sensor and HP/VXI data acquisition device were used and TDAS software was also used as a data sampling and processing tools. The natural frequencies and mode shape of the test rod were consistent with the previous works of a rod vibration test with partial grids($3{\times}3,\;5{\times}5\;and\;7{\times}7$). The frequency characteristics of the rod according to the mounting location were shown clear discrepancies, but mode shapes were nearly same. As the test rod closes to the bottom clamping region of the spacer grid, peak vibration amplitudes of the rod become smaller.

  • PDF

A Study on the Partial Discharge Phase Properties with Branch Type Eleotrical Tree Growth in XLPE Cable Insulation (XLPE 케이블 절연체에서의 가지형 전기트리 성장에 따른 부분방전 위상 특성 연구)

  • Gang, Dong-Sik;Seon, Jong-Ho;Kim, Wi-Yeong;Lee, Hong-Sik;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.213-221
    • /
    • 2002
  • In order to improve the reliability of XLPE cables, it is necessary to find the useful diagnostic parameter according to long term aging. This paper described the change of partial discharge(PD) phase Properties of XLPE cable insulation with branch type electrical tree degradation. for long term aging. To understand the PD Properties with $\phi$ -q-n distributed shape of XLPE insulation, specimens were prepared by 22.9㎸ distribution cable and made in a type of block(16${\times}$16${\times}$3[mm]). Ogura needles having tip radius of l0${\mu}{\textrm}{m}$ were inserted into each block pieces. The measuring system was consisted of PD detector, digitizer for digital conversion, VXI system for signal processing. The PD properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed. We analyzed the relationship between electrical properties(PD Quantity, PD initiation angle, PD extinction angle, PD occurrence angle : (PD extinction angle - PD initiation angle)) and the normalized aging rate. We found PD parameter, PD initiation angle and occurrence angle, which are a useful diagnostic parameter in estimating the branch type electrical tree for XLPE insulation condition.