• Title/Summary/Keyword: VS reduction

Search Result 491, Processing Time 0.026 seconds

Vibration Characterization of Cross-ply Laminates Beam with Fatigue Damage (피로 손상을 입은 직교 복합재료 적층보의 진동 특성)

  • 문태철;김형윤;황운봉;전시문;김동원;김현진
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.1-4
    • /
    • 2001
  • A new non-destructive fatigue prediction model of the composite laminates is developed. The natural frequencies of fatigue-damaged laminates under extensional loading are related to the fatigue lift of the laminates by establishing the equivalent flexural stiffness reduction as a function of the elastic properties of sublaminates. The flexural stiffness is derived by relating the $90^{\circ}$-ply elastic modulus reduction, and using the laminate plate theory to the degraded elastic modulus and the intact elastic modulus of other laminate. The natural frequency reduction model, in which the dominant fatigue mode can be identified from the sensitivity scale factors of sublaminate elastic properties, provides natural frequency vs. fatigue cycle curves for the composite laminates. Vibration tests were also conducted on $[\textrm{90}_{2}\textrm{0}_{2}]_s$ carbon/epoxy laminates to verify the natural frequency reduction model. Correlations between the predictions of the model and experimental results are good.

  • PDF

Electrocatalytic Reduction of Carbon Dioxide on Sn-Pb Alloy Electrodes

  • Choi, Song Yi;Jeong, Soon Kwan;Park, Ki Tae
    • Journal of Climate Change Research
    • /
    • v.7 no.3
    • /
    • pp.231-236
    • /
    • 2016
  • Electrocatalytic reduction can produce useful chemicals and fuels such as carbon monoxide, methane, formate, aldehydes, and alcohols using carbon dioxide, the green house gas, as a reactant through the supply of electrical energy. In this study, tin-lead (Sn-Pb) alloy electrodes are fabricated by electrodeposition on a carbon paper with different alloy composition and used as cathode for electrocatalytic reduction of carbon dioxide into formate in an aqueous system. The prepared electrodes are measured by Faradaic efficiency and partial current density for formate production. Electrocatalytic reduction experiments are carried out at -1.8 V (vs. Ag/AgCl) using H-type cell under ambient temperature and pressure and the gas and liquid products are analyzed by gas chromatograph and liquid chromatograph, respectively. As results, the Sn-Pb electrodes show higher Faradaic efficiency and partial current density than the single metal electrode. The Sn-Pb alloy electrode which have Sn:Pb molar ratio=2:1, shows the highest Faradaic efficiency of 88.7%.

Diagnostic Performance of 2018 KLCA-NCC Practice Guideline for Hepatocellular Carcinoma on Gadoxetic Acid-Enhanced MRI in Patients with Chronic Hepatitis B or Cirrhosis: Comparison with LI-RADS Version 2018

  • Sang Min Lee;Jeong Min Lee;Su Joa Ahn;Hyo-Jin Kang;Hyun Kyung Yang;Jeong Hee Yoon
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1066-1076
    • /
    • 2021
  • Objective: To evaluate the performance of the 2018 Korean Liver Cancer Association-National Cancer Center (KLCA-NCC) Practice Guidelines (hereafter, PG) for the diagnosis of hepatocellular carcinoma (HCC) using gadoxetic acid-enhanced MRI, compared to the Liver Imaging-Reporting and Data System (LI-RADS) version 2018 (hereafter, v2018). Materials and Methods: From January 2013 to October 2015, treatment-naïve hepatic lesions (≥ 1 cm) on gadoxetic acid-enhanced MRI in consecutive patients with chronic hepatitis B or cirrhosis were retrospectively evaluated. For each lesion, three radiologists independently analyzed the imaging features and classified the lesions into categories according to the 2018 KLCA-NCC PG and LI-RADS v2018. The imaging features and categories were determined by consensus. Generalized estimating equation (GEE) models were used to compare the per-lesion diagnostic performance of the 2018 KLCA-NCC PG and LI-RADS v2018 using the consensus data. Results: In total, 422 lesions (234 HCCs, 45 non-HCC malignancies, and 143 benign lesions) from 387 patients (79% male; mean age, 59 years) were included. In all lesions, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity and lower specificity than LR-5 (LI-RADS v2018) (87.2% [204/234] vs. 80.8% [189/234], p < 0.001; 86.2% [162/188] vs. 91.0% [171/188], p = 0.002). However, in lesions of size ≥ 2 cm, the definite HCC had a higher sensitivity than the LR-5 (86.8% [164/189] vs. 82.0 (155/189), p = 0.002) without a reduction in the specificity (80.0% [48/60] vs. 83.3% [50/60], p = 0.15). In all lesions, the sensitivity and specificity of the definite/probable HCC (2018 KLCA-NCC PG) and LR-5/4 did not differ significantly (89.7% [210/234] vs. 91.5% [214/234], p = 0.204; 83.5% [157/188] vs. 79.3% [149/188], p = 0.071). Conclusion: For the diagnosis of HCC of size ≥ 2 cm, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity than LR-5, without a reduction in specificity. The definite/probable HCC (2018 KLCA-NCC PG) had a similar sensitivity and specificity to that those of the LR-5/4.

Three Treatment Methods via the Hepatic Artery for Hepatocellular Carcinoma - A Retrospective Study

  • Ma, Teng-Chuang;Shao, Hai-Bo;Xu, Yang;Xu, Ke
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2491-2494
    • /
    • 2013
  • Background: To evaluate the relative effectiveness of different treatments of hepatocellular carcinoma (HCC) via the hepatic artery. Materials and Methods: The study sample group consisted of 418 patients who were randomly selected from 2008 to 2012 with a first diagnosis of HCC and treated with transcatheter arterial chemoembolization (TACE) or without (TAE) chemotherapy or transcatheter arterial infusion (TAI). We collected data including tumor size preoperative and one month thereafter to compare change in areas across the three groups, along with various laboratory indexes for comparison. Results: The overall average change of areas was $240.8{\pm}72.1mm^2$. In the three groups it was $265.0{\pm}58.0mm^2$ vs. $250.5{\pm}51.9mm^2$ vs. $123.7{\pm}26.2mm^2$. In groups TACE and TAE values were larger than in group TAI (p<0.01), but the difference between the two was not statistically significant (p= 0.191). Additionally, U/L change of aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in groups TACE and TAE was greater than in the TAI cases ($24.0{\pm}13.5$ vs. $20.9{\pm}12.1$ vs. $5.47{\pm}8.20$ and $25.6{\pm}13.5$ vs.$23.2{\pm}12.28$ vs.$5.48{\pm}14.3$) on the preoperative day and two days thereafter (p<0.01). Between the two groups there was no significant cariation (p= 0.320 and p= 0.609). However, the AST and ALT recovered to normal levels one month later on therapy with liver protecting drugs. Conclusion: The groups TACE and TAE demonstrated more effective reduction of tumor size than group TAI. While lipiodol caused acute liver function damage, this proved reversible.

Treatment Outcomes of Mandibular Advancement Devices in Obstructive Sleep Apnea Patients

  • Kim, Cheon-Sik;Lee, Yong-Seok;Cho, Cheon-Ung;Kim, Dae-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.43 no.2
    • /
    • pp.82-88
    • /
    • 2011
  • Mandibular advancement devices (MAD) are therapeutic options for obstructive sleep apnea (OSA). The aim of study was to investigate treatment outcomes of before and after insertion of MAD in OSA patients. We retrospectively selected a total of 13 patients who were diagnosed with OSA syndrome. All sleep-related parameters including apnea-hypopnea index (AHI), oxygen desaturation index (ODI), wake after sleep onset (WASO), total arousal were measured by before and after MAD. The use of MAD proves to be efficient in reducing snoring, apnea-hypopne index ($17.2{\pm}14.6$ vs $20.9{\pm}14.6$), WASO ($27.4{\pm}28.8$ vs $47.9{\pm}43.6$), oxygen desaturation index ($9.0{\pm}11.6$ vs $16.4{\pm}11.7$), stage N3 ($54.8{\pm}45.2$ vs $36.6{\pm}22.0$), REM sleep times ($73.3{\pm}19.4$ vs $66.0{\pm}31.0$) and increases sleep efficiency ($92.6{\pm}6.6$ vs $87.2{\pm}11.2$). The decreases in apnea index based on a reduction in the overall and supine AHI values after MAD therapy were significantly greater for the positional OSA than nonpositional OSA patients. The use of MAD proves to be efficient in snoring, WASO, sleep efficiency, reduced AHI and associated with good compliance of patients.

  • PDF

Clinical Features and Factors Affecting Success Rate of Air Reduction for Pediatric Intussusception (공기 정복술을 시행 받은 소아 장중첩증 환자들의 치료 결과 및 성공률에 영향을 미치는 요인)

  • Son, Il-Tae;Jung, Kyu-Whan;Park, Tae-Jin;Kim, Hyun-Young;Park, Kwi-Won;Jung, Sung-Eun
    • Advances in pediatric surgery
    • /
    • v.16 no.2
    • /
    • pp.108-116
    • /
    • 2010
  • Air reduction is a safe, effective, and fast initial treatment for pediatric intussusception. There is low dose radiation exposure. Factors affecting outcomes of air reduction were analyzed by reviewing the clinical features and results of treatment. A total of 399 out of 485 patients with pediatric intussusceptions were treated at the Seoul National University Children's Hospital from 1996 to 2009. All of the patients received air reduction as the first line of treatment. Clinical features such as gender, age, seasonal variation, symptoms, signs, types, pathologic leading point, and treatment results including success rate, complication, recurrence, NPO time, and duration of hospitalization were reviewed. The Pearson chi-square, student T-, and logistic regression tests were used for statistical analysis. P-value less than 0.05 was considered to be statistically significant. The prevalent clinical features were: male (65.4 %), under one-year of age (40.3 %), ileocolic type (71.9 %), abdominal pain (85.4 %), and accompanying mesentery lymph node enlargement (2.2 %). The overall success rate for air reduction was 78.4 % (313 of 399 patients), and the perforation rate during reduction was 1.5 %. There were 23 recurrent cases over 21.6 months. All were successfully treated with re-do air reduction. Reduction failures had longer overall NPO times (27.067hrs vs. 43.0588hrs; p=0.000) and hospitalization durations (1.738d vs. 6.975d; p=0.000) compared to the successful cases. The factors affecting success rates were fever (p=0.002), abdominal distension (p=0.000), lethargy (p=0.000) and symptom duration (p=0.000) on univariate analysis. Failure rates were higher in patients with symptom durations greater than 24 hours (p=0.023), and lethargy (p=0.003) on multivariate analysis. Air reduction showed high success rates and excellent treatment outcomes as the initial treatment for pediatric intussusception in this study. Symptom duration and lethargy were significantly associated with reduced success rates.

  • PDF

Management of Pediatric Small Bowel Intussusception: Spontaneous Reduction vs Operation (소아의 소장 중첩증의 치료 : 자연 정복 vs 수술적 치료)

  • Kim, Eun-Young;Jung, Kyu-Whan;Park, Tae-Jin;Park, Kwi-Won;Jung, Sung-Eun;Kim, Hyun-Young
    • Advances in pediatric surgery
    • /
    • v.16 no.2
    • /
    • pp.117-125
    • /
    • 2010
  • Unreduced small bowel intussusception requires operative treatment although the rate of spontaneous reduction is 60 to 70 %. The aim of this study is to compare clinical characteristics and outcome between spontaneous reduction and operation group and to analyze factors related to decisions to treat small bowel intussusceptions. The records of 25 patients with small bowel intussusceptions treated in Seoul National University Children's Hospital from January 1999 to August 2009 were reviewed respectively. Spontaneous reduction group (n=12, 48 %) had signs and symptoms of vomiting, abdominal pain, currant jelly stool, abdominal distension, fever, increased CRP but no rebound tenderness. One of them had been diagnosed with Henoch-Schonlein purpura and no one displayed pathologic leading point by image study. Operation group (n=13, 52 %) consisted of patients who had primary surgery. Their signs and symptoms were similar to spontaneous reduction group. Seven of them had underlying diseases such as Crohn' disease, ALL, Lymphoma, Peutz-Jeghers syndrome (n=3), post-transplanted state of liver and 2 of them displayed Peutz-Jeghers polyp and Meckel's diverticulum as pathologic leading point by preoperative ultrasonography. Mean relieve interval (interval between onset of symptoms and reduction/operation) was 1.78 days in spontaneous reduction group and 2.25 days in operation group (p=0.341). Seven of operation group had manual reduction and 6 out of 7 received segmental resection of the small bowel. No one of them underwent manual reduction and all of them underwent segmental resection were found to have pathologic leading points [Peutz-Jeghers polyp (n=3), Meckel's diverticulum (n=2), lymphoma (n=1)] during operation. In conclusion, 48% of small bowel intussusceptions resolved spontaneously. Patients' symptoms and relieve intervals were not related to the operative decisions. We therefore recommend significant factors for determining treatment plan such as change of clinical symptoms, underlying disease or pathologic leading point by imaging.

  • PDF

Selective Electrochemical Reduction on the Imino Group of ${\alpha},{\beta}$-Dibenzyl N-Benzylidene L-Aspartate (${\alpha},{\beta}$-Dibenzyl N-Benzylidene L-Aspartate 의 Imino 기에 대한 선택적 전해환원반응)

  • Kim, Il-Kwang;Kim, Youn-Geun;Lee, Young-Haeng;Chai, Kyu-Yun
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.614-622
    • /
    • 1989
  • The electrochemical reduction of ${\alpha},{\beta}$-dibenzyl N-benzylidene L-aspartate in 0.1M LiCl ethanol solution was investigated by direct current (DC), differential pulse (DP) polarography, cyclic voltammetry and controlled potential coulometry(CPC). The irreversible reductive amination of imino group proceeded to form ${\alpha},{\beta}$-dibenyl N-benzyl L-aspartate by CEC or CE electrochemical reaction mechanism at the first reduction step (-0.92 volts vs. Ag-AgCl). The polarographic reduction wave was slightly suppressed due to inhibitory effect of micelle, while the irreversibility was increased according to the increase of Triton X-100 concentration. Upon the basis of product analysis and polarogram interpretation with pH change, possible CE electrode reaction mechanism was suggested.

  • PDF

Biomimetic Copper Complex Containing Polymer Modified Electrode for Electrocatalytic Reduction of Oxygen

  • Saravanakumar, D.;Nagarale, Rajaram Krishna;Jirimali, Harish Chandra;Lee, Jong Myung;Song, Jieun;Lee, Junghyun;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.298-305
    • /
    • 2016
  • The development of non-precious metal based electrocatalysts is highly desired for the oxygen reduction reaction (ORR) as alternates to noble metal based ORR electrocatalysts. Herein, we report mononulcear copper(II) complex $[CuLbpy]ClO_4$ (L=4-[(2-hydroxyphenylimino)methyl]benzoic acid) containing poly(allylamine.HCl) polymer (PAlACuLbpy) as an electrocatalyst for oxygen reduction reaction (ORR). PAlACuLbpy was mixed with poly(acrylic acid) and tetraethylortho silicate to prepare a composite and then deposited on the screen printed electrode surface. The modified electrode (PAlACuLbpy/PCE) is highly stable and showed a quasi-reversible redox behavior with $E_{1/2}=-0.2V$ vs. Ag/AgCl(3 M KCl) in 0.1 M phosphate buffer at pH 7 under argon atmosphere. PAlACuLbpy/PCE exhibited a remarkable ORR activity with an onset potential of -0.1 V vs Ag/AgCl in 0.1 M PB (pH 7) in the presence of oxygen. The kinetics for ORR was studied by rotating disk voltammetry in neutral aqueous medium and the results indicated that the number of electrons involving in the ORR is four and the conversion products are water and hydrogen peroxide.

Quantity vs. Quality in the Model Order Reduction (MOR) of a Linear System

  • Casciati, Sara;Faravelli, Lucia
    • Smart Structures and Systems
    • /
    • v.13 no.1
    • /
    • pp.99-109
    • /
    • 2014
  • The goal of any Model Order Reduction (MOR) technique is to build a model of order lower than the one of the real model, so that the computational effort is reduced, and the ability to estimate the input-output mapping of the original system is preserved in an important region of the input space. Actually, since only a subset of the input space is of interest, the matching is required only in this subset of the input space. In this contribution, the consequences on the achieved accuracy of adopting different reduction technique patterns is discussed mainly with reference to a linear case study.