• 제목/요약/키워드: VP8

검색결과 275건 처리시간 0.025초

A 18-Mbp/s, 8-State, High-Speed Turbo Decoder

  • Jung Ji-Won;Kim Min-Hyuk;Jeong Jin-Hee
    • Journal of electromagnetic engineering and science
    • /
    • 제6권3호
    • /
    • pp.147-154
    • /
    • 2006
  • In this paper, we propose and present implementation results of a high-speed turbo decoding algorithm. The latency caused by (de) interleaving and iterative decoding in a conventional maximum a posteriori(MAP) turbo decoder can be dramatically reduced with the proposed design. The source of the latency reduction is come from the combination of the radix-4, dual-path processing, parallel decoding, and rearly-stop algorithms. This reduced latency enables the use of the turbo decoder as a forward error correction scheme in real-time wireless communication services. The proposed scheme results in a slight degradation in bit-error rate(BER) performance for large block sizes because the effective interleaver size in a radix-4 implementation is reduced to half, relative to the conventional method. Fixed on the parameters of N=212, iteration=3, 8-states, 3 iterations, and QPSK modulation scheme, we designed the adaptive high-speed turbo decoder using the Xilinx chip (VIRTEX2P (XC2VP30-5FG676)) with the speed of 17.78 Mb/s. From the results, we confirmed that the decoding speed of the proposed decoder is faster than conventional algorithms by 8 times.

X선 진단시 피폭선량을 반으로 줄이기 위한 Cu Filter의 두께 (The thickness of Cu Filter to reduce 1/2 of the patient dose)

  • 김정민;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권1호
    • /
    • pp.17-22
    • /
    • 2001
  • Medical X-ray examination are increased double for the last $6{\sim}8$ years. Therefore a patient exposure dose should be decrease half every 7 years. We made an experiment on copper filter thickness to decrease a patient exposure dose up to half and compared to the Image quality by MTF. The results as follow 1. A thin region like extremities needs a thicker Cu filter as compared a thick region. 2. 1/2 reduction filter must be thicker when kVp Increase. 3. Exposure factor should be increas when using 1/2 reduction filter ; extremity is 4.0 times, chest 2.9 times, skull 1.62 times, and abdomen 1.58 times 4. The MTF of using 1/2 reduction filter is lower than without filter. But no difference of visual image. 5. 1/2 reduction filter compared with double speed screen showed almost same image quality.

  • PDF

2차 멀티비트 Sigma-Delta 변조기 설계 및 제작 (Design and Fabrication of Second-Order Multibit Sigma-Delta Modulator)

  • 김선홍;최석우;조성익;김동용
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권9호
    • /
    • pp.650-656
    • /
    • 2004
  • This paper presents block and timing diagrams of the DWA(data weighted averaging) to optimize a feedback time delay of the sigma-delta modulator. Through the Matlab modeling, the optimized coefficients of the integrators are obtained to design the modulator. And then the fully differential SC integrators, feedback DAC, 9-level quantizer, and DWA are designed by considering the nonideal characteristics of the modulator. The designed second-order multibit modulator is fabricated in a 0.35$\mu\textrm{m}$ CMOS process. The designed modulator achieves 73dB signal-to-noise ratio and 72dB dynamic range at 1.2Vp-p 585kHz input singal and 52.8MHz sampling frequency.

A Method of Preparing Recombinant Fusion Antigen from Rotavirus and Norovirus

  • Oh, Ho-Kyung;Huh, Chul-Sung;Baek, Young-Jin;Yoo, Dong-Wan
    • 한국축산식품학회:학술대회논문집
    • /
    • 한국축산식품학회 2004년도 정기총회 및 제33차 춘계 학술대회
    • /
    • pp.353-356
    • /
    • 2004
  • Rotavirus and Norovirus are major causative agents of acute diarrhea and gastroenteritis. In our study, Each viral RNA was isolated from the feces of patients for viral diarrhea in Korea, respectively. And cDNA library were constructed using RT-PCR. Also, cDNAs encoding VP8 derived from Rotavirus and Capsid protein derived from norovirus were subesequently cloned and expressed in Echerichia coli as a fusion antigen. Molecular weight of fusion antigen was approximately 60kDa. Also, substantial overexpression was accomplished. We yielded egg yolk lgY which is potentially useful in controlling of Rotavirus and Norovirus which are one of the most prevalent pathogenic viruses.

  • PDF

흉부(胸部) X선검사시(線檢査時) 환자(患者)의 피폭선양(被曝線量)에 대(對)한 연구(硏究) (A Study of the Patient Dose in Chest Radiography)

  • 김창균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제13권1호
    • /
    • pp.3-9
    • /
    • 1990
  • A study was carried out to investigate the technical factors and the patient dose (entrance and absorbed dose) in chest P-A radiography based on the 86 hospitals in Seoul from July 1 to July 30, 1989. As a result of this study, main finding were as follow : 1. 51.2% of the surveyed hospitals made use of $60{\sim}69\;kVp$ as tube voltage in chest radiography 2. The majority of the surveyed(88.3%) have the use of $6{\sim}20\;mAs$ as tube current-time. 3. Percentage absorbed doses in patient were showed more than 90 percent in every tube voltage. 4. Object densities were all much the same in all tube voltages. 5. 48.8% of surveyed entrance doses ranged from $100\;{\mu}Sv$ to $190\;{mu}Sv$, and the mean dose was $158\;{\mu}Sv$.

  • PDF

손 방사선검사에서 조사야 크기와 보조관심영역 변화가 노출지수 값에 미치는 영향 (Effects of Changes in Collimation Size and the sub ROI on Exposure Index of Hand Radiography)

  • 주영철;홍동희
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.851-857
    • /
    • 2023
  • 본 연구는 손 방사선검사에서 조사야 크기와 sub ROI의 변화가 EI값에 미치는 영향을 알아보고, 한국인의 평균 손 크기에 적합한 조사야 크기 및 EI값 제시하고, sub ROI 변화가 EI 값에 미치는 영향을 제시하는데 목적이 있다. hand wrist phantom을 대상으로 했으며, 조사조건은 55 kVp, 125 mA, 6.25 mAs로 설정하였고, 초점-영상수용체 간 거리는 110 cm로 적용하였다. 제조사에서 권고하는 sub ROI('ss' 타입)을 기준으로 조사야 크기 4종류(18.7"×18.7", 8"×10", 8"×7.4", 6"×7.4")와 교과서에서 권고하는 조사야 크기 8"×10"에서 sub ROI 5가지를 변화 시키며, 각각 30개의 영상을 획득하였고, 이때 장비에서 나타나는 EI를 비교분석하였다. 조사야 크기 변화에 따른 EI값은 18.7"×18.7"의 경우 1663.7±4.52, 8"×10"은 1489.1±4.49, 8"×7.4"은 1716.9±3.00, 6"×7.4"은 1681.7±3.66로 나타났으며, 각 값의 평균값은 통계적으로 유의했다. sub ROI 변화에 따른 EI값의 평균은 SS의 경우 1489.1±4.49이었으며, LS는 1694.8±5.19, AEC는 2052.9±5.96, VR은 1548.3±3.20, HR은 1663.2±4.33로 나타났다. 한국인의 손 크기를 고려한 적절한 조사야 크기는 8"×7.4"로 나타났다. 또한 손 방사선검사 시 일반적으로 알려진 조사야 크기(8"×10")를 기준으로 조사야 크기가 증가하면 EI값은 최대 15%에서 최소 11%까지 변화되었으며, sub ROI 'SS'를 기준으로 sub ROI 형태 변화에 따른 EI값은 최대 37%에서 최소 3%까지 증가하였다.

소 로타바이러스(국내분리주)에 대한 단크론항체 생산 및 특성에 관한 연구 (Studies on the production and characterization of monoclonal antibodies against bovine rotaviruses isolated in Korea)

  • 안재문;조선희;강신영
    • 대한수의학회지
    • /
    • 제36권2호
    • /
    • pp.395-403
    • /
    • 1996
  • Monoclonal antibodies(MAbs) against field isolates of the bovine rotavirus A strain(G6), V strain(G10) and reference I-801 strain(G8) were produced and characterized. Six MAbs(4C2, 4D9, 5E1, 5E7, 5D5, 3E4) against A strain had neutralizing activity and reacted only with the G6 bovine rotaviruses determined by fluorescence focus neutralization (FFN) test. Otherwise, five neutralizing MAbs(1G2, 2G6, 5E2, 5E12, 5H7) against I-801 strain neutralized the G6 and G8 bovine rotaviruses. Five non-neutralizing MAbs(5F12, 7F12, 5E11, 2A11, 2B12) were VP6-specific and cross-reacted with all bovine and porcine rotaviruses examined by fluorescence antibody(FA) test. None of the MAbs reacted with bovie viral diarrhea virus(BVDV) and bovine coronavirus(BCV) determined by FA and FFN test.

  • PDF

MPN 및 H-NS 유전자를 표적으로 하는 PCR assay를 병용한 장염비브리오(Vibrio parahaemolyticus)의 정량 (Quantification of Vibrio parahaemolyticus Using a Most Probable Number-Polymerase Chain Reaction Assay Targeting the H-NS gene)

  • 김태옥;박권삼
    • 한국수산과학회지
    • /
    • 제47권5호
    • /
    • pp.556-561
    • /
    • 2014
  • We applied a combination of most probable number-polymerase chain reaction (MPN-PCR) methods using a PCR procedure targeting the H-NS (VP1133) gene to detect Vibrio parahaemolyticus presence and density in seawater as well as within short-necked clam Ruditapes philippinarum tissues collected from Gomso Bay, Korea. In 30 seawater samples, V. parahaemolyticus levels ranged from less than 1.8 to $1.1{\times}10^3MPN/100mL$, and samples from August showed higher than those from other months. Furthermore, the levels of V. parahaemolyticus in six short-necked clam samples ranged from $7.8{\times}10^2$ to $2.1{\times}10^3MPN/100g$, approximately 2.5 times higher than in seawater samples from the corresponding month. Our results provide data on V. parahaemolyticus contamination in seawater and short-necked clam tissues, and help to improve quantitative methods of assessing V. parahaemolytcius levels.

유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구 (A Study on Dose Reduction in Infant Skull Radiography)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.387-392
    • /
    • 2017
  • 영 유아는 사건, 사고 및 교통사고 또는 질병으로 인해 머리에 골절 및 혈관파열, 피부에 상처를 받아 병원에 내원하여 영상의학과에서 머리 검사인 전 후(Skull AP) 및 측면(Skull LAT) 촬영을 받게 된다. 머리검사에서 성인 머리(Skull) 촬영은 격자를 이용하여 촬영에 적용하면 방사선 2차선을 제거하여 영상의 대조도를 높인다. 그러나 방사선 노출조건 중 관전압을 8~10 kVp 높게 주어야 하며 환자피폭이 증가한다. 본 연구는 영 유아 머리촬영시 격자(grid)를 이용하지 않고 동등한 영상을 얻을 수 있다면 피폭선량 감소 및 Grid Cut off에 의한 아티팩트를 방지할 수 있어 연구해 보았다. 연구자는 방사선계측기 이용 방사선선량을 측정 하고 의료영상평가 방법 중에서 주관적 평가(ROC,receiver operationg characteristic)을 해 보았다. 결과에서 격자를 이용하지 않고 촬영하면 환자 피폭선량 감소와 영상 평가에서도 영 유아의 머리 촬영시 격자를 이용하지 않고 촬영을 하게 되면 머리 전 후촬영에서 0.019 mGy 와 측면촬영 0.02 mGy 피폭선량 감소가 있었고 영상평가에서도 4점을 높게 받았다. 결론으로 병원에 내원한 영 유아 머리촬영은 격자를 이용하지 않고 촬영하면 피폭 선량 감소 및 영상 아티팩트인 Grid Cut off을 방지 할 수 있고 엑스선관 수명이 연장되리라 사료된다.

The Patterns of Intraosseous Venography before Percutaneous Vertebroplasty for Osteoporotic Compression Fractures

  • Kim, Dong-Sung;Doh, Jae-Won;Lee, Kyeong-Seok;Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Seong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권6호
    • /
    • pp.288-293
    • /
    • 2008
  • Objective : Bone cement leakage is a well-known potential complication of percutaneous vertebroplasty (PVP) in patients with osteoporotic compression fracture. Even though there has been a controversy in the efficacy of antecedent venography to prevent this complication, many authors have performed intra osseous venography before bone cement injection. The goal of this study was to classify the venous drainage patterns of spine before PVP, and compare their patterns at different vertebral levels. Methods : The authors retrospectively reviewed 1,042 intraosseous venographic patterns in 321 patients with 574 osteoporotic compression fractures during six-year period in one institution. To classify venogram patterns, we selected simple lateral X-ray of spine taken immediately after injection of the contrast dye. We classified the venography patterns according to contrast leakage pattern and leakage direction as follows; trabecular (TR), trabecular anterior (TA), trabecular posterior (TP), trabecular anterior-posterior (TAP), trabecular lateral (TL), venous anterior(VA), venous posterior (VP), venous anterior-posterior (VAP), soft tissue (ST). Also, we compared venogram patterns according to different spinal levels. Results : In overall, the most common pattern was TP type accounting for 37.4% (390/1042) of all intraosseous venograms. This is followed by TAP in 21.5%, TR 17.4%, TA 116%, TL 5.8%, ST 4.1%, VA 1.2%, VP 0.6%, and VAP 0.4% in descending order of frequency. According to the spinal level, TR and TAP types were most common in thoracic spine (T6-T10), TP type was most common in thoraco-Iumbar spine (T11-L2), and TP and TAP types were most common in lumbo-sacral spine (L3-S1). Contrast dye leakage to soft tissue such as psoas muscle or disc were detected in 43 (4.1%) venograms. Direct venous drainage without staining of vertebral body was found in 23 (2.2%) venograms. The 8.3% of thoracic venogram showed direct venous drainage. Thoracic level showed a more tendency of direct venous drainage than other spine levels (p<001). Conclusion : The authors propose a new classification system of intra osseous venography during PVP. The trabecular-posterior (TP) type is most common through all spine, and venous-filling (V) type was most frequent in thoracic spine. Further study would be necessary to elucidate the efficacy of this classification system to prevent bone cement leakage during PVP.