• 제목/요약/키워드: VP7

검색결과 278건 처리시간 0.028초

Detection and molecular characteristics of bovine rotavirus A in dairy calves in China

  • Liu, Xiaoying;Yan, Nan;Yue, Hua;Wang, Yuanwei;Zhang, Bin;Tang, Cheng
    • Journal of Veterinary Science
    • /
    • 제22권5호
    • /
    • pp.69.1-69.12
    • /
    • 2021
  • Background: Bovine group A rotavirus (BoRVA) is a major cause of severe gastroenteritis in newborn dairy calves. Only one study has investigated the G and P genotypes among dairy calves in a few regions of China, which were G6 and P[5]. Therefore, data on the prevalence and molecular characteristics of BoRVA in dairy calves in China remains limited. Objectives: The purpose of this study was to investigate the prevalence and molecular characteristics of BoRVA in dairy calves in China. Methods: 269 dairy calves diarrheic samples from 23 farms in six provinces in China were collected to detect BoRVA using reverse transcription polymerase chain reaction. Results: 71% of samples were determined to be BoRVA-positive. Two G genotypes (G6, G10) and two P genotypes (P[1], P[5]) were identified, and G6P[1] BoRVA was the predominant strain. Moreover, the VP7 and VP4 gene sequences of these dairy calf BoRVA strains revealed abundant genetic diversity. Interestingly, eight out of 17 complete G6 VP7 sequences were clustered into G6 lineage VI and analysis showed the strains were closely related to Chinese yak BoRVA strains. Conclusions: The results of this study show that BoRVA circulates widely among dairy calves in China, and the dominant genotype in circulation is G6P[1], first report on molecular characteristics of complete P[5] VP4 genes in chinese dairy calves. These results will help us to further understand the prevalence and genetic evolution of BoRVA among dairy calves in China and, thus, prevent the disease more effectively.

An Emergence of Equine-Like G3P[8] Rotaviruses Associated with Acute Gastroenteritis in Hospitalized Children in Thailand, 2016-2018

  • Chaiyaem, Thanakorn;Chanta, Chulapong;Chan-it, Wisoot
    • 한국미생물·생명공학회지
    • /
    • 제49권1호
    • /
    • pp.120-129
    • /
    • 2021
  • Rotavirus A (RVA) is recognized as a major etiology responsible for the development of acute gastroenteritis in children worldwide. The purpose of the present study was to perform the molecular characterization of RVA. A total of 323 stool specimens collected from hospitalized children with acute gastroenteritis in Chiang Rai, Thailand, in 2016-2018 were identified for G- and P-genotypes through RT-PCR analysis. RVA was more prevalent in 2017-2018 (37.8%) than in 2016-2017 (23.2%). The seasonal peak of RVA occurred from March to April. G3P[8] was predominant in 2016-2017 (90.6%) and 2017-2018 (58.6%). Other genotypes including G1P[8], G8P[8], G9P[8], and mixed infections were also identified. G3P[8] strains clustered together in the same lineage with other novel human equine-like G3P[8] strains previously identified in multiple countries and presented a genotype 2 constellation (G3-P[8]-I2-R2-C2-M2-A2-N2-T2-E2-H2). Several amino acid differences were observed in the antigenic epitopes of the VP7 and VP8* capsid proteins of the equine-like G3P[8] compared with those of the RVA vaccine strains. The homology modeling of the VP7 and VP8* capsid proteins of the equine-like G3P[8] strains evidently exhibited that these residue differences were present on the surface-exposed area of the capsid structure. The emergence of the equine-like G3P[8] strains in Thailand indicates the rapid spread of strains with human and animal gene segments. Continuous surveillance for RVA is essential to monitor genotypes and genetic diversity, which will provide useful information for selecting rotavirus strains to develop a safe and effective RVA vaccine that is efficacious against multiple genotypes and variants.

ConeBeam CT로 임플란트 검사 시 MAR 기능 유무와 선량조건에 따른 정량적 및 정성적 평가 (Quantitative and Qualitative Evaluation according to Radiation Dose Conditions when using MAR function in Implant examination from Cone Beam CT)

  • 안현준;김상현
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.905-917
    • /
    • 2022
  • 본 연구는 각각의 방사선 선량 조건을 나눠 검사할 때 MAR 기능의 사용과 영상 품질을 평가하기 위해 수행되었다. 실험을 위해 임플란트가 박힌 간단한 Periapical Phantom을 만들었고, CBCT 장비를 이용하여 선량 조건별로 MAR 기능의 유무에 따라 영상을 획득하고 실험에 임하였다. 본 연구에서는 Image J 프로그램을 이용하여 MEAN, SNR, 그리고 CNR 값들을 획득하였고, 통계 분석을 통해 Abutment of Implant 부분은 100 kVp, 8 mA 조건일 때, Center of Implant와 Apex of Implant 부분에서는 100 kVp, 9 mA 조건일 때 영상이 가장 정량적이고 적합한 값이었다. 따라서 방사선량이 증가하면 영상의 Pixel value, SNR, CNR 값이 상승해 화질이 향상되고, MAR 기능을 사용하면 Artifact가 줄어드는 것을 확인할 수 있었다.

웨이블릿을 이용한 디지털유방영상의 노이즈 제거 (Denoising of Digital Mammography Images Using Wavelet Transform)

  • 최석윤;고성진;강세식
    • 한국방사선학회논문지
    • /
    • 제7권3호
    • /
    • pp.181-189
    • /
    • 2013
  • 디지털유방촬영기에서 자동모드를 설정해서 검사를 할 경우 환자가 받는 평균유선선량(average grandular dose)를 줄일 수 있는 방법을 제시하고자 최적의 노출 파라미터를 찾고 노이즈 감소 알고리즘을 적용하여 화질을 개선하고자 한다. 실험을 위하여 Nuclear Associates Model 18-222 의 팬텀을 사용 하였으며, 입사선량(enterance dose)과 평균 유선선량을 측정하였다. 다음 노이즈(noise) 제거 알고리즘을 적용하였고, 적용 전 후에 대해서 Signal, Noise, SNR, FOM을 측정하고 비교 평가 하였다. 실험결과 첫째, 노이즈 제거 전 Mo/Mo 23kvp에서 SNR이 가장 높았고, 평균유선 선량은 W/Rh 35kvp 에서 가장 낮았다. FOM 결과 W/Rh의 28kVp를 사용하는 것이 가장 좋은 것으로 나타났다. 노이즈 제거 알고리즘 적용 후 SNR은 Mo/Mo 23kvp에서 SNR 가장 높았고, FOM의 결과 W/Rh의 28kVp를 사용 하는것이 가장 좋은 것으로 나타났다. 이때 동일한 평균유선선량을 갖는 조건에서 노이즈 값은 4.36에서 1.74로 감소되었으며, SNR 값은 4.6에서 11.6으로 향상되었다. 제안하는 노이즈 제거 처리를 적용하면 영상에서 중요한 정보를 유지하면서 노이즈를 감소시킬 수 있고, 최적의 노이즈 처리와 최적의 검사조건을 선택함으로써 유방 검사 시 발생하는 방사선 피폭을 줄일 수 있을 것이다.

일반촬영 시 거리역자승법칙에 따른 산란선 감약에 관한 연구 (The Study About Attenuation of Scatter Ray According to Distance Inverse Square Law at General Projection)

  • 전민철;임현수;한만석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권3호
    • /
    • pp.183-188
    • /
    • 2011
  • 거리 역자승 법칙에 관한 엑스선 감약의 정도를 파악하고 이를 산란선 발생에서 적용하여 방사선사의 피폭을 저감할 수 있는 공간을 찾도록 알아보고자 하였다. 관전류량 10 mAs, 관전압 60 kVp, 70 kVp, 81 kVp, 90 kVp, 각각의 거리 60 cm, 120 cm, 180 cm에서 1차 선량을 측정하고, 산란선은 관전류량 20 mAs, 관전압 70 kVp, phantom의 중심부로부터 전면과 후면으로 42.5 cm, 52.5 cm, 62.5 cm 떨어진 곳에서 음 양극(좌우측)으로 각각 10 cm씩 60 cm까지 측정하였고, 거리역자승법칙과 비교하기 위해 전 후방 각각 42.5 cm, 85 cm, 127.5 cm에서 산란선을 측정하였다. 1차선은 거리가 2배에서는 20.52 mR(27.20%), 28.58 mR(25.20%), 38.82 mR(26.32%), 48.20 mR(26.27%)로 감약되고 거리가 3배에서는 7.06 mR(8.91%), 9.90 mR(8.73%), 13.64 mR(9.25%), 16.60 mR(9.05%)로 감약되는 것을 알 수 있었고, 산란선은 전 후방 각각 거리가 2배에서는 0.15 mR(23.09%), 0.15 mR(22.08%) 3배에서는 0.07 mR(10.43%), 0.06 mR(8.83%)로 감약되었다. 산란선의 발생량이 평균적으로 3사분면이 적게 발생하기에 환자를 붙잡고 촬영할 시에는 3사분면의 피사체에서 가능하면 거리를 두고 환자를 잡는 것이 피폭선량을 줄일 수 있다.

영상보간법을 이용한 디지털 치근단 방사선영상의 개선에 관한 연구 (A Study on the Improvement of Digital Periapical Images using Image Interpolation Methods)

  • 송남규;고광준
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.387-413
    • /
    • 1998
  • Image resampling is of particular interest in digital radiology. When resampling an image to a new set of coordinate, there appears blocking artifacts and image changes. To enhance image quality, interpolation algorithms have been used. Resampling is used to increase the number of points in an image to improve its appearance for display. The process of interpolation is fitting a continuous function to the discrete points in the digital image. The purpose of this study was to determine the effects of the seven interpolation functions when image resampling in digital periapical images. The images were obtained by Digora, CDR and scanning of Ektaspeed plus periapical radiograms on the dry skull and human subject. The subjects were exposed to intraoral X-ray machine at 60kVp and 70 kVp with exposure time varying between 0.01 and 0.50 second. To determine which interpolation method would provide the better image, seven functions were compared; (1) nearest neighbor (2) linear (3) non-linear (4) facet model (5) cubic convolution (6) cubic spline (7) gray segment expansion. And resampled images were compared in terms of SNR(Signal to Noise Ratio) and MTF(Modulation Transfer Function) coefficient value. The obtained results were as follows ; 1. The highest SNR value(75.96dB) was obtained with cubic convolution method and the lowest SNR value(72.44dB) was obtained with facet model method among seven interpolation methods. 2. There were significant differences of SNR values among CDR, Digora and film scan(P<0.05). 3. There were significant differences of SNR values between 60kVp and 70kVp in seven interpolation methods. There were significant differences of SNR values between facet model method and those of the other methods at 60kVp(P<0.05), but there were not significant differences of SNR values among seven interpolation methods at 70kVp(P>0.05). 4. There were significant differences of MTF coefficient values between linear interpolation method and the other six interpolation methods (P< 0.05). 5. The speed of computation time was the fastest with nearest -neighbor method and the slowest with non-linear method. 6. The better image was obtained with cubic convolution, cubic spline and gray segment method in ROC analysis. 7. The better sharpness of edge was obtained with gray segment expansion method among seven interpolation methods.

  • PDF

자연산 자주새우(Crangon affinis)에서 흰반점바이러스(WSSV)의 neutralization을 위한 인위감염(experimental infection) (Experimental Infection for the Neutralization of White Spot Syndrome Virus (WSSV) in Wild Captured Sand Shrimp, Crangon affinis)

  • 공수정;김영진;최미란;김성구
    • 생명과학회지
    • /
    • 제20권9호
    • /
    • pp.1294-1298
    • /
    • 2010
  • 흰반점바이러스(WSSV)는 새우양식산업에 막대한 경제적 손실을 일으키는 가장 치명적인 바이러스성 질병 원인체 중 하나이다. 본 연구는 인위적인 실험모델로서 WSSV에 대한 자주새우(Crangon affinis)의 감수성을 확인하고자 실험을 수행하였다. WSSV가 희석된 수조 내에서 침지법으로 감염된 새우는 감염 후 7일째에 100% 누적폐사율을 보여 자주새우가 WSSV에 대해 매우 높은 감수성을 갖고 있음을 확인하였다. 또한 재조합단백질인 rVP466에 대한 항혈청의 중화효과를 확인하기 위해 항혈청과 반응시킨 바이러스액($1{\times}10^4$ 배로 희석된 WSSV)을 이용하여 침지법으로 자주새우에 대해 공격실험(challenge test)을 수행하였다. 실험 결과, WSSV로 challenge한 감염대조구(positive control)의 새우들은 감염 후 5일째에 100% 폐사하였으며, WSSV와 rVP466 항혈청을 1:0.01, 1:0.1, 1:1로 혼합한 액으로 challenge한 새우들은 감염 후 14일째에 각각 100%, 68.8%, 68.8%의 누적폐사율을 보였다. 따라서 본 연구 결과는 연안서식종인 자주새우가 양식장으로부터 배출된 WSSV에 의해 자연상태에서 감염 될 수 있는 가능성과 함께 항혈청에 대한 중화효과를 나타냄으로써 겨울철 저수온기에 WSSV 감염을 위한 대체 실험생물로서의 유용성을 확인하였다.

흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구 (A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom)

  • 황혜성;김누리;정윤지;구은회;김기정
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

뇌실복강간 단락술(Ventriculoperitoneal Shunt)을 시행한 환자에서의 서혜부 탈장의 빈도와 특성 (Inguinal Hernia and Ventriculoperitoneal Shunt)

  • 이성철;이혁준;김기홍;정성은;박귀원;김우기
    • Advances in pediatric surgery
    • /
    • 제6권2호
    • /
    • pp.89-94
    • /
    • 2000
  • Ventriculoperitoneal shunt(VP shunt) for hydrocephalus is thought to inhibit the closure of processus vaginalis and promote inguinal hernia by increasing intraabdominal pressure. To estimate the patency rate of processus vaginalis and the incidence and characteristics of the inguinal hernia, 262 cases of VP shunt in early childhood between January 1980 and May 1998 at Seoul National University Children Hospital were reviewed retrospectively. Inguinal hernia developed in 28 cases(10.7 %), but six patients had an inguinal hernia before the VP shunt was placed. Patients who had a VP shunt before 6 months of age developed inguinal hernia in 16.2 %(12/74) of cases, patients shunted between 6 months and 2 years had an incidence of 12.4 %(11/89) and only 5.1 %(5/99) of patients operated upon after 2 years of age developed hernias. Twenty-two patients out of 256 cases (8.6 %) developed inguinal hernia after VP shunt, with male predominance(M : F=4.5:1). Eight patients developed inguinal hernia bilaterally(36.4 %). It is suggested that at least 14% of processus vaginalis is patent until 2 years old.

  • PDF

Assessment of the efficiency of a pre- versus post-acquisition metal artifact reduction algorithm in the presence of 3 different dental implant materials using multiple CBCT settings: An in vitro study

  • Shahmirzadi, Solaleh;Sharaf, Rana A.;Saadat, Sarang;Moore, William S.;Geha, Hassem;Tamimi, Dania;Kocasarac, Husniye Demirturk
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.1-7
    • /
    • 2021
  • Purpose: The aim of this study was to assess artifacts generated in cone-beam computed tomography (CBCT) of 3 types of dental implants using 3 metal artifact reduction (MAR) algorithm conditions (pre-acquisition MAR, post-acquisition MAR, and no MAR), and 2 peak kilovoltage (kVp) settings. Materials and Methods: Titanium-zirconium, titanium, and zirconium alloy implants were placed in a dry mandible. CBCT images were acquired using 84 and 90 kVp and at normal resolution for all 3 MAR conditions. The images were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD) to calculate the intensity of artifacts for each combination of material and settings. A 3-factor analysis of variance model with up to 3-way interactions was used to determine whether there was a statistically significant difference in the mean intensity of artifacts associated with each factor. Results: The analysis of all 3 MAR conditions showed that using no MAR resulted in substantially more severe artifacts than either of the 2 MAR algorithms for the 3 implant materials; however, there were no significant differences between pre- and post-acquisition MAR. The 90 kVp setting generated less intense artifacts on average than the 84 kVp setting. The titanium-zirconium alloy generated significantly less intense artifacts than zirconium. Titanium generated artifacts at an intermediate level relative to the other 2 implant materials, but was not statistically significantly different from either. Conclusion: This in vitro study suggests that artifacts can be minimized by using a titanium-zirconium alloy at the 90 kVp setting, with either MAR setting.