• Title/Summary/Keyword: VP1-2A

Search Result 428, Processing Time 0.026 seconds

Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change (Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구)

  • Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5~24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100kVp, apply SAFIRE strength 0~5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100kVp than 120kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality amount also is thought to be able to be reduced.

Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control (자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가)

  • Young-Cheol, Joo;Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.871-877
    • /
    • 2022
  • This study was conducted to improve the problems of exposure dose and image reading applied to patients due to the incorrect use of AEC during chest radiography. Images were acquired by dividing the case where AEC was used as the test condition and the case where AEC was not used. As a result of the study, the dose was reduced by 1.17% in 110 kVp without AEC than with AEC, 17.2% decrease at 100 kVp, 30.19% decrease at 90 kVp, and 46.45% decrease at 80 kVp. There was a significant difference in the statistical values according to the tube voltage change in the lung, trachea, and heart SNR average values with AEC and without AEC 110 kVp, but the difference in image quality was insignificant in actual images. When AEC was not applied at the same tube voltage, the dose could be reduced by 17.2% while maintaining the image quality similar to that of with AEC at 100 kVp without AEC. Therefore, rather than relying on AE conditions during chest radiographic examination, it is considered that the conditions should be considered for the examination while lowering the dose by selecting an appropriate tube voltage.

Analysis of antigenic sites on the VP4 of porcine rotavirus, Gottfried strain (돼지 로타바이러스(Gottfried 주)의 VP4 항원구조분석)

  • Song, Yun-kyung;Kim, Won-yong;Kang, Shien-young
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.343-350
    • /
    • 2001
  • The neutralization epitopes of the outer capsid protein VP4 of a porcine rotavirus, Gottfried strain, were studied using neutralizing monocolonal antibodies(N-MAbs). Eight N-MAbs which are specific for the VP4 of Gottfried strain were used for analyzing the antigenic sites of VP4. Three different approaches were used for this analysis; i)testing the serological reactivity of each N-MAb against different G and P types of human and animal rotavirusese ii) analyzing N-MAb-resistant viral escape mutants and iii) performing nucleotide sequence analysis of the VP4 gene of each N-MAb-resistant viral escape mutant. From experimental results, at least four antigenic sites(I, II, III, and IV) were identified. Antigenic site I recognized by N-MAbs 24B9, 23G10, and 26A2 was separated from antigenic site II recognized by N-MAbs 30H5, 32B3, and 29B3. However, these antigenic sites were overlapped with antigenic site III recognized by N-MAb 21A1. The other antigenic site IV recognized by N-MAb 16D2 was separated from antigenic sites I, II, and III.

  • PDF

Studies on the VP4 and VP7 Genes of Bovine Rotaviruses from Field Samples Using RT-PCR and RFLP Analysis (RT-PCR과 RFLP법을 이용한 국내 소 로타바이러스 VP4 및 VP7 유전자의 특성 규명)

  • Jeon, Seong-Jin;Chang, Chung-Ho;Chung, Chung-Won;Kim, Won-Yong;Kang, Shien-Young
    • The Journal of Korean Society of Virology
    • /
    • v.28 no.2
    • /
    • pp.165-174
    • /
    • 1998
  • Characterizations of the VP4 (P type) and VP7 (G type) genes of Korean isolates of bovine rotavirus were performed using RT-PCR/RFLP and nucleotide sequencing analysis. After RT-PCR amplification of partial length (1094bp) of the VP4 and full length (1062bp) of the VP7 genes, amplified PCR products were digested with restriction endonucleases and digestion patterns were compared with those of reference rotaviruses. With the VP4 genes, four RFLP (A-D) profiles were observed; three (A, Band C) were the same as those of bovine rotavirus NCDV (P[1]), IND (P[5]) and B223 (P[11]), respectively. Profile D was the same as that of porcine rotavirus OSU (P[7]). With the VP7 genes, five RFLP profiles (I-V) were observed; three of them (I, II and III) were the same as those of bovine rotavirus NCDV (G6), Cody 1-801 (G8), and B223 (G10), respectively. Profile IV and V were atypical to those of reference bovine rotaviruses used in this study. These two profiles were identified as G6 and G5, respectively, after analyzing and comparing the nucleotide sequences. The G typing analysis revealed that 61.9% (26/42) were G6, which included G6 subtype; 28.6% (12/42) were G5; 7.1% (3/42) were G10; 2.4% (1/42) were G8. The P typing analysis revealed that 54.8% (23/42) were P[5]; 28.6% (12/42) were P[7]; 11.8% (5/42) were [11]; 4.8% (2/42) were P[1]. Our results showed that G6/P[5] were the most prevalent rotaviruses in diarrheic calves in Korea. Also, this is the first report that G5/P[7] rotaviruses were identified from cattle with diarrhea.

  • PDF

Effects of Gas Composition in the Modified Atmosphere Packaging on the Shelf-life of Longissimus dorsi of Korean Native Black Pigs-Duroc Crossbred during Refrigerated Storage

  • Muhlisin, Muhlisin;Panjono, Panjono;Kim, Dong Soo;Song, Yeong Rae;Lee, Sung-Jin;Lee, Jeong Koo;Lee, Sung Ki
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.8
    • /
    • pp.1157-1163
    • /
    • 2014
  • This study was conducted to observe the effects of gas composition in modified atmosphere packaging (MAP) on the shelf-life of Longissimus dorsi of Korean Native Black Pigs-Duroc Crossbred ($KNP{\times}D$) during refrigerated storage. Muscle sample was obtained from the left side of carcass of seven months old of $KNP{\times}D$ barrow. The sample was sliced into 1 cm in thickness, placed on trays (two slices/tray) and filled with different gas composition, i.e. 0:20:80/$O_2:CO_2:N_2$ (MAP1), 30:20:50/$O_2:CO_2:N_2$ (MAP2) and 70:20:10/$O_2:CO_2:N_2$ (MAP3). Other slices of sample were vacuum packed (VP) as a control. All packs were stored at $5{\pm}1^{\circ}C$. At 12 d of storage, pH value of MAP2 and MAP3 were higher (p<0.05) than that of MAP1 and pH value of MAP1 was higher (p<0.05) than that of VP. At 6 d of storage, redness ($a^*$) value of MAP2 and MAP3 were higher (p<0.05) than that of VP and MAP1 and, at 9 and 12 d of storage, redness value of MAP3 was higher (p<0.05) than that of VP, MAP1, and MAP2. At 3, 6, 9, and 12 d of storage, the 2- thiobarbituric acid reactive substances (TBARS) value of MAP3 was higher than that of MAP2 and TBARS value of MAP2 was higher than that of VP and MAP1. At 3, 6, 9, and 12 d of storage, volatile basic nitrogen values of MAP2 and MAP3 were higher (p<0.05) than those of VP and MAP1. At 3 d of storage, total aerobic plate counts of MAP2 and MAP3 were higher (p<0.05) than those of VP and MAP1 and, at 6 d of storage, total aerobic plate counts of MAP3 was higher (p<0.05) than that of MAP1 and MAP2. However, there was no significant different total aerobic plate count among MAP1, MAP2, and MAP3 at 9 and 12 d of storage. There was no significant different total anaerobic plate count among MAP1, MAP2, and MAP3 during storage. It is concluded that the MAP containing 30:20:50/$O_2:CO_2:N_2$ gas composition (MAP2) might be ideal for better meat quality for $KNP{\times}D$ meat.

RADIOGRAPHIC INTERPRETATION OF EXPERIMENTALLY PRODUCED BONY DEFECT ACCORDING TO kVp (관전압 변화에 다른 실험적 골결손부의 방사선사진상의 판독)

  • Nam Hye Kyung;Choi Karp Shik;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.265-276
    • /
    • 1990
  • The purpose of this experiment was to evaluate radiographic interpretation, of various sized 60 periapical and 60 cancellous lesions in 10 mandibular sections of 5 dogs according to kVp (65, 70, 75, 80 and 85 kVp). The results were as follows; The change of kilovoltage within 65kVp-85kVp range did not have influence on the radiographic interpretation of the same-sized bony defects at the constant radiographic density (p> 0.05). When the bony defects were less than the size of No.2 round bur, radiographic interpretation of bony defects prepared with No.2 round bur was easier than those prepared with No. 1 round bur at 80-85kVp in periapical region (p<0.05). However, in cancellous bone, this radiographic interpretation was easier at 65-75kVp (p<0.05). There were significant differences in the radiographic interpretation between the defects confined only to the cancellous, bone and the defects involved in the compact bone (p<0.05). However there were no significant differences between the defects confined only to the cancellous bone and the defects involved in junctional area of cancellous and compact bone (p>0.05). From the results of densitometric analysis, there was a difference in densitometric measurements at the same radiographic interpretation scores, and aluminum equivalent differences of 0.15-1.66㎜ thickness were needed for radiographic interpretation.

  • PDF

Resistance against white spot syndrome virus (WSSV) infection in wild marine crab Gaetice depressus by injection of recombinant VP28 protein

  • Kim, Chun Soo;Choi, Seung Hyuk;Kim, Min Sun;Kim, Ki Hong
    • Journal of fish pathology
    • /
    • v.27 no.1
    • /
    • pp.11-16
    • /
    • 2014
  • The resistance against white spot syndrome virus (WSSV) infection in wild marine crab Gaetice depressus by the immunization of a recombinant glutathione-S-transferase (GST) fused VP28 protein (GST-VP28) was evaluated. The cumulative mortalities of GST-VP28 injected groups were lower than those of the control groups at 10 days of post-challenge, and the time to death of 50% crab ($TD_{50}$) was delayed by the immunization using GST-VP28. The group boosted with GST-VP28 after 2 weeks of primary immunization clearly showed longer $TD_{50}$ than non-boosted group against challenge with WSSV. This result suggests that boosting with the antigen protein elicit stronger immune responses similar to adaptive immune responses of vertebrates. However, the short $TD_{50}$ was observed in the group challenged at 3 weeks post boosting comparing to the group challenged at 1 week post boosting. This suggests that the protective strength of immunization decreased by the time.

Distribution of Disease Severity and Group A Rotavirus Genotypes (VP7 & VP4) in Children with Acute Rotavirus Gastroenteritis (급성 로타바이러스 장염 소아에서 질환의 중증도와 로타바이러스 VP7 & VP4 유전형의 분포에 대한 연구)

  • Oh, Hyun-Ju;Kang, Hyun-Sik;Kang, Ki-Soo;Kim, Youn-Woo;Hong, Jung-Yun;Shin, Kyung-Sue;Lee, Jin-Sook;Lee, Su-Hyun;Lee, Keun-Hwa;Cho, Moon-Je;Suh, Dong-In
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.14 no.2
    • /
    • pp.148-154
    • /
    • 2011
  • Purpose: We aimed to study the distribution of rotavirus genotypes (VP7 and VP4) and disease severity of rotavirus gastroenteritis prevalent in our community. Methods: Stool samples were collected from 156 children who were hospitalized with rotavirus gastroenteritis from December 2007 to June 2008. The disease severity of all patients was scored using the Vesikari scale. After extraction of ds-RNA of the rotavirus, cDNA synthesis using reverse transcription and polymerase chain reaction (RT-PCR) and multiplex PCR was performed. Following this, the final identification of genotypes was performed. Results: Of the 156 samples, VP7(G) and VP4(P) genotypes were identified in 147 (94.2%) and 140 (89.7%) samples, respectively. G1 (116 of 147 samples; 78.9%) and P[8] (137 of 140 samples; 97.9%) were the most prevalent, respectively. Of the 138 samples identified of combination types of VP7 and VP4, G1P[8] (111 samples; 80.4%) was the most prevalent. Other combination types varied with very low distribution rates. 9.4% of genotypes were not included in the new vaccines. The disease severity score was $11.8{\pm}3.3$ ($mean{\pm}2SD$). The distribution of disease severity was mild or moderate in 37.8% and severe in 62.2% of patients. Conclusion: The most prevalent genotype combination of rotavirus was G1P[8] and genotypes not included in the vaccines represented 9.4% in our community. Disease severity distribution of hospitalized children with rotavirus gastroenteritis was higher in the severe than in the mild and moderate categories.

A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography (복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구)

  • Kim, Jung-Min;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

Noise Reduction on Low Tube Voltage CT Images (저관전압 CT영상에서 발생되는 노이즈 제거)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • To reduce the exposure dose in head CT, the use of low tube voltage is required. However, increasing noise may cause errors in the second data processing. In this study, we proposed a method to reduce noise by using low tube voltage. Experimental results show that the noise level is high at 100kVp and lowest at 140 kVp. The dose was lower at 100 kVp and higher at 140 kVp. As a result of applying the wavelet according to the threshold value, the noise value in the wavelet Th30 decreased to 4.51. Using the parameter condition(100 kVp, rotation time 0.5 sec, dose: 40.64 mGy) and the wavelet Th 30, the dose reduction of 65.3% was possible. We believe that applying the proposed method to head CT images will help to patient safety and interpret accurate information.