• Title/Summary/Keyword: VOCs in air

Search Result 599, Processing Time 0.029 seconds

A Study on Indoor Air Quality in new Ship (새로 건조된 선박의 실내공기환경 조사 연구)

  • Doe, Geun-Young;Lee, Han-Seok;Lee, Yun-Gyu;Lee, Hyong-Ki
    • Journal of Navigation and Port Research
    • /
    • v.31 no.5 s.121
    • /
    • pp.427-434
    • /
    • 2007
  • Indoor air pollution has been a critical issue as a new environmental problem and a significant amount of research has been performed on the indoor air pollution in buildings as well us those in mean of transport such as automobiles, subways, and buses. The actual condition of indoor air pollution in ships, however, was not investigated. Because airtightness of a ship is very higher than a general building and the crew spend almost all the time in indoor space of the ship during underway, indoor air quality(IAQ) of the ship is very important for their comfortableness and health. In this paper, indoor air quality of a new ship is measured and analyzed for the improvement of IAQ in ships.

A Study on Estimation of Air Pollutants Emission from Wood Stove and Boiler, Wood-pellet Stove and Boiler (화목난로∙보일러와 펠릿난로∙보일러 사용에 의한 대기오염물질 배출량 산정에 관한 연구)

  • Kim, Dong-Young;Han, Yong-Hee;Choi, Min-Ae;Park, Sung-Kyu;Jang, Young-Kee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.251-260
    • /
    • 2014
  • Biomass burning is one of the significant emission source of PM and CO, but a few studies are reported in Korea. Air pollutants emission from biomass burning such as wood stove and boiler, and wood-pellet stove and boiler were estimated in this study. Activity levels related to biomass burning such as fuel types, amount of fuel loading, and location and temporal variation were investigated by field survey over Korea. Fuel loadings were 14.9 kg/day for wood stove, 31.3 kg/day for wood boiler, 12.8 kg/day for wood-pellet stove, 32.5 kg/day for wood-pellet boiler during the season of active use. These were mostly burned in winter season from october to april of next year. Estimated annual emissions from wood stove & boiler were CO 76,677, $NO_x$ 710, $SO_x$ 70, VOC 20,941, TSP 6,605, PM10 2,921, PM2.5 1,851, and NH3 7 ton/yr, respectively. Emissions from wood-pellet stove and boiler were CO 32,798, $NO_x$ 1,830, $SO_x$ 25, VOCs 5,673, TSP 629, PM10 457, PM2.5 344, and $NH_3$ 2 ton/yr, respectively. When the emission estimates are compared with total emissions of the national emission inventory (CAPSS: Clean Air Policy Support System), Those occupy 12.5%, 2.8% of total national emission for CO and PM10, respectively. These results show wood and wood-pellet burning appliances were one of the major source of air pollution in Korea. In future, these types of heaters need to be regulated to reduce air pollution, especially in suburb area.

Emissions of Air Pollutants and Greenhouse Gases from Aircraft Activities at the Small Scale Airports (국내 일반공항에서 항공기에 의한 대기오염물질과 온실가스의 배출량 산정 및 특성 분석)

  • Shon, Zang-Ho;Song, Sang-Keun;Yoon, Tae-Kyung;Lee, Gang-Choon
    • Journal of Environmental Science International
    • /
    • v.22 no.7
    • /
    • pp.823-836
    • /
    • 2013
  • Emissions of air pollutants and greenhouse gases (GHGs) from aircraft activities at 11 small-scale airports were investigated using the emissions and dispersion modeling system (EDMS) version 5.1.3 during the two year period of 2009~2010. The number of landing and take-off (LTO) at these airports was dominant for the aircraft type B737, accounting for more than 60% of the total LTOs. Out of the 11 small-scale airports, Gwangju (GJ, RKJJ) airport was the largest emitter of air pollutants and GHGs, whereas Yangyang (YY, RKNY) airport was the smallest emitter. The emissions of $NO_x$ and VOCs in 2010 at the 11 airports ranged from 1.9 to 83 ton/y and 0.1 to 17 ton/y, respectively. In 2010, the emissions of $CO_2$ ranged from 394 to 21,217 ton/y. The emissions of most air pollutants (except for $NO_x$ and $PM_{10}$) and GHGs were estimated to be the highest in taxi-out mode. The highest emissions of $NO_x$ and $PM_{10}$ were emitted from climb-out and approach modes, respectively. In addition, the total LTOs at the 11 small-scale airports accounted for the range of 9.3~9.9% of those at four major international airports in Korea. The total emissions of air pollutants and GHGs at the 11 airports ranged from 4.8 to 12% of those at the four major airports.

Evaluation of Indoor Air Quality in a Hospital Operating Room During Laparoscopic Surgery (병원 수술실에서의 복강경 수술 중 실내공기질 평가)

  • Choi, Dong Hee;Kang, Dong Hwa
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.3
    • /
    • pp.67-74
    • /
    • 2024
  • Purpose: The identification and quantification of indoor airborne contaminants, including bio-aerosols, particulates, and gaseous contaminants, are crucial for maintaining acceptable indoor air quality for hospital operating rooms (ORs). Laparoscopic surgery has become widely accepted for various surgical procedures due to its rapid recovery rate and the low risk associated with small incisions compared to conventional open surgery. The objective of this study is to investigate the indoor air quality in hospital ORs and to identify indoor airborne contaminants generated during laparoscopic surgery. Methods: Measurements of an indoor environment, including temperature, humidity and air quality, were performed in an OR before and during a laparoscopic surgery. Indoor airborne contaminants, including volatile organic compounds (VOCs), formaldehyde, carbon monoxide (CO), carbon dioxide (CO2), sulfur dioxide (SO2), nitrogen dioxide (NO2), suspended indoor particles, and airborne bacteria, were measured simultaneously. Results: The study determined that the concentrations of indoor air particles and airborne bacteria increased during the surgery but were within acceptable levels. However, the concentration of CO2, reached a high level of 1,791 ppm due to the CO2 gas required for maintaining the pneumoperitoneum during the surgery. Implications: The results emphasized the use of ventilation and filtration in a laparoscopic surgery room to lower the concentration of filterable and non-filterable contaminants.

Indoor Air Quality in Elementary School Children's Homes in Ulsan: Comparison between Groups with and without Allergic Rhinitis (울산지역 초등학생 가정의 실내공기질: 알레르기 비염 환아군과 대조군 비교)

  • Lee, Chi-Hyeon;Lee, Byeong-Kyu;Oh, In-Bo;Lee, Ji-Ho;Sim, Chang-Sun;Kim, Yang-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.365-373
    • /
    • 2012
  • This study compared indoor air quality of homes in which elementary school children with and without (case and control) allergic rhinitis live in the Ulsan metropolitan region (UMR). A total of 58 homes (case and control: 29, respectively; children aged 7 to 12 years) was selected for indoor air quality measurements. The concentrations of all general indoor air pollutants, except $PM_{2.5}$, in the case group were much higher than those in the control group. In particular, the average concentrations of $O_3$ and $NO_2$ in the case group were statistically significantly (p<0.05) higher than those in the control group. Average concentrations of $CO_2$ in the case and control groups and $NO_2$ in the case group exceeded the standard level. Some components of aldehydes and ketones and VOCs indicated large difference of average concentrations between two groups, but there were no statistically significant differences.

House-plant placement for indoor air purification and health benefits on asthmatics

  • Kim, Ho-Hyun;Yang, Ji-Yeon;Lee, Jae-Young;Park, Jung-Won;Kim, Kwang-Jin;Lim, Byung-Seo;Lee, Geon-Woo;Lee, Si-Eun;Shin, Dong-Chun;Lim, Young-Wook
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.14.1-14.8
    • /
    • 2014
  • Objectives Some plants were placed in indoor locations frequented by asthmatics in order to evaluate the quality of indoor air and examine the health benefits to asthmatics. Methods The present study classified the participants into two groups: households of continuation and households of withdrawal by a quasi-experimental design. The households of continuation spent the two observation terms with indoor plants, whereas the households of withdrawal passed the former observation terms with indoor plants and went through the latter observation term without any indoor plants. Results The household of continuation showed a continual decrease in the indoor concentrations of volatile organic compounds (VOCs) during the entire observation period, but the household of withdrawal performed an increase in the indoor concentrations of VOCs, except formaldehyde and toluene during the latter observation term after the decrease during the former observation term. Peak expiratory flow rate (PEFR) increased in the households of continuation with the value of 13.9 L/min in the morning and 20.6 L/min in the evening, but decreased in the households of withdrawal with the value of -24.7 L/min in the morning and -30.2 L/min in the evening in the first experimental season. All of the households exhibited a decrease in the value of PEFR in the second experimental season. Conclusions Limitations to the generalizability of findings regarding the presence of plants indoors can be seen as a more general expression of such a benefit of human-environment relations.

Characteristics of long-term behavior of VOC species in Korea - PAMS data analysis (우리나라 휘발성유기화합물 화학종의 장기 거동 특성 - 광화학오염물질 측정자료 분석)

  • Park, Ji Hoon;Kang, Soyoung;Song, In-Ho;Lee, Dong-Won;Cho, SeogYeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.56-75
    • /
    • 2018
  • Korean Photochemical Assessment Monitoring Stations (PAMS) have been established since the late 2001 to monitor ambient air concentrations of VOC species, which would enhance understanding photo-chemical formation of ozone and subsequently contribute to developing efficient ozone control strategies. The present study aims at identifying major VOC species and examining their trends by analyzing PAMS monitoring data collected from the year 2006 to 2016. All the 18 PAMS sites operated by the Ministry of Environment were included in the study. PAMS monitored the 56 target VOC species, which are classified into four groups, alkenes, lower alkanes ($C{\leq}3$), higher alkanes ($C{\geq}4$), aromatics. The higher alkanes and aromatics dominated over the lower alkanes and alkenes in the type 2 and 3 PAMS sites except Joongheung site. N-butane was a major alkane species, toluene was a major aromatic species and most of VOCs showed decreasing trends in these sites. On the other hand, only the alkenes showed decreasing trends at the Joongheung site in Yeosu. Major sources of abundant species such as ethane, propane, n-butane, toluene were estimated by analyzing seasonal variations, correlation with other VOC species, and emission profiles. A major source of n-butane was identified as LPG cars, while major sources of toluene varied considerably from one site to another. The lower alkanes were composed of ethane and propane, both of which showed a strong seasonal variation, low in the summer and high in the winter, indicating that a major source might be the heating by gaseous fuels. Ozone formation potentials of VOC species were evaluated by applying MIR and POCP to the measured VOC species concentrations. Toluene contributed the most to total ozone forming potentials followed by m,p-xylene for all the type 2 and 3 PAMS sites except for two sites in Yeosu-Gwangyang. Ethylene and propylene were the first and second contributors to total ozone forming potentials at Joongheung site in Yeosu.

Ecotoxicity Estimation of Hazardous Air Pollutants Emitted from Semiconductor Manufacturing Processes Utilizing QSAR

  • Park, Hyung-Geun;Yeo, Min-Kyeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3755-3761
    • /
    • 2013
  • This study aims to assess the ecological risk of the hazardous air pollutants (HAPs) emitted in the semiconductor manufacturing processes in Korea by using Quantitative Structure Activity Relationship (QSAR, EPA, US, EPI $Suite^{TM}$ 4.1). Owing to the absence of environmental standards of hazardous air pollutants in the semiconductor manufacturing processes in Korea, 18 HAPs in the semiconductor field included in both the US EPA NESHAPs and the hazardous air pollutant list of Ministry of Environment in Korea were selected. As a results 8 chemicals (44.4%) of the selected 18 HAPs were VOCs. Cyanides (cyanides) and ethylene oxides (epoxy resins), and tetrachloro-ethylene (aliphatic compounds, halides) showed long half-lives. Cyanide HAPs especially had the highest half-life with the estimated value of 356.533 days. Nickel compounds (heavy metal compounds) possessed the highest water solubility followed by acetaldehyde (aldehyde compounds), ethylene oxides, and 1,4-dioxanes. The halides, including tetrachloro-ethylenes, carbon tetra-chlorides, benzene (aromatic compounds), and lead (heavy metals), are estimated to take the longest time for biodegradation. Tetrachloroethylene, with the acute toxicity end point of 3.685-7.033 mg/L, was assessed to be the most highly toxic substance among the 18 HAPs. However, considering the absence of the HAPs in the common category of log $K_{ow}{\geq}4$and $BCF{\geq}500$, which indicates the standard of bioconcentration potentials, potentials of the bioconcentration are considered to be low.

Estimating Personal Exposures to Air Pollutants in University Students Using Exposure Scenario (노출 시나리오를 이용한 대학생들의 유해 공기오염물질 노출 추정)

  • Kim, Sun-Shin;Hong, Ga-Yeon;Kim, Dong-Keon;Kim, Sung-Sam;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.47-57
    • /
    • 2013
  • Studies evaluating the health effects of hazardous air pollutants assume that people's exposure to typical pollutant level is the same as specific regional pollutant level. However, depending on social and demographic factors, time-activity pattern of people can vary widely. Since most people live in indoor environments over 88% of the day, evaluating exposure to hazardous air pollutants is hard to characterize. Objective of this study was to estimate the exposure levels of university students of $NO_2$, VOCs(BTEX) and $PM_{10}$ using the scenarios with time-activity pattern and indoor concentrations. Using data from time-use survey of National Statistical Office in 2009, we investigated time-activity pattern of university students and hourly major action. A total of 1,057 university students on weekday and 640 on weekend spent their times at indoor house 13.04 hr(54.32%), other indoors 7.70 hr(32.06%), and transportation 2.36 hr(9.83%). Indoor environments in which university students spent their times were mainly house and school. Air pollutants concentrations of other indoor environments except house and school such as bar, internet cafe and billiard hall were higher than outdoors, indicating that indoor to outdoor ratios were above 1. According to three types of exposure scenarios, exposure to air pollutants could be reduced by going home after school.

The Effective Evaluation of Soil Remediation Technology by Gas Phase Concentration Trend (가스상 물질의 농도변화를 이용한 오염토양 복원의 타당성 평가)

  • Park, Duck-Shin;Jung, Woo-Sung;Kang, Sun-Ki;Kim, Moo-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1233-1241
    • /
    • 2000
  • The purpose of this study is to see the remediability and pilot system operating condition on diesel contaminated areas. Air permeability(k) and trend of gas phase ($O_2/CO_2/VOCs$) concentration to determine the remediation rate of the contaminated sites are very important. So we tested air permeability and trend of gas phase concentration. Throughout soil vapor extraction(SVE) and bioventing hybrid pilot test on different conditions, the range of air permeability(k) was 1985~1194 darcy. The tests result in soil vapor extraction and bioventing hybrid system was appropriate on this test sites, and the suitable injection air flow rate was $3.5m^3/hr$.

  • PDF