• Title/Summary/Keyword: VOCs in air

Search Result 599, Processing Time 0.027 seconds

Analysis of Indoor Air Pollutants from Elementary School Classrooms with Different Environment in Ulsan, Korea (울산광역시 초등학교 실내공기오염물질의 환경적 특성에 따른 농도 분석)

  • Lee, Chi-Hyeon;Lee, Byeong-Kyu;Kim, Yang-Ho;Lee, Ji-Ho;Oh, In-Bo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.97-116
    • /
    • 2011
  • This study analyzed indoor air pollutants from elementary school with different environment. Air sampling and measurement were carried out from classrooms and hallways from three target elementary schools in the fall and winter seasons. The winter average concentrations of $PM_{10}$, $CO_2$, CO, aldehydes and ketones, and benzene were higher than the fall ones. The fall average concentrations of $O_3$ and $NO_2$ were higher than the winter ones. The concentrations of $PM_{10}$ and $CO_2$ at the schools near the heavy traffic areas and having poor ventilation were higher than those from the other elementary school. The average concentration of CO at the school having heavy traffic volume was highest. The concentrations of $O_3$, $NO_2$, aldehydes and ketones, and VOCs at the school near the shipbuilding industries were highest among the three elementary schools.

Potential Exposure of Indoor Air Pollutants inside Vehicle for Professional Taxi Drivers (영업용 택시 운전자들의 공기오염물질 노출평가)

  • Yang Won-Ho;Kim Dae-Won;Kim Young-Hee;Kim Jong-Oh
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.4 s.58
    • /
    • pp.69-75
    • /
    • 2005
  • Professional taxi driver exposure to indoor air pollutants has been a subject of concern in recent years because of higher levels of air pollutants, comparing to the surrounding atmosphere. This study evaluated the potential exposure to respirable suspended particulate (RSP), nitrogen dioxide $(NO_2)$ and volatile organic compounds (VOCs; benzene and toluene) for professional taxi drivers inside each of 10 vehicles in Pusan, comparing weekday (Monday and Thursday) and weekend (Saturday). Indoor mean concentrations of RSP inside vehicle were $53.88\;ug/m^3\;and\;75.52\;ug/m^3$ on weekday and weekend, respectively. Measured indoor $NO_2$ concentrations were 28.32ppb and 40.69 ppb, respectively. Benzene and toluene mean concentrations inside vehicle were 5.41 ppb and 11.36 ppb, respectively. Considering no smoking of taxi drivers inside vehicle, closed window in winter, and increased usage of taxi on weekend, source of indoor air pollutants inside taxi might be mainly suggested from the number of passenger's carried, faulty exhaust systems, and engine and carburetor evaporative emissions.

A Study on the Washability and Washing Conditions of the Industrial Alkaline Laundry Detergent Suitable for Water Discharge Standards and Detergent Regulations (수질 배출기준 및 세제 안전기준에 적합한 산업용 알칼리 세탁세제의 세척성과 세탁조건 연구)

  • Song, Hyunjoo;Song, Sunhye
    • Textile Coloration and Finishing
    • /
    • v.33 no.4
    • /
    • pp.250-257
    • /
    • 2021
  • Laundry industry has traditionally been considered an industry that generates large amounts of wastewater and Volatile Organic Compounds(VOCs). This is still the case until now. Household laundry detergents are produced and distributed within the safety regulations on the amount of harmful substances detected. While industrial laundry detergents are often distributed without safety regulations, and even laundry workers manufacture and use them on their own. This contaminates water and air and also threatens the safety of workers. This study is a basic study for distributing eco-friendly detergents(EFD-A) developed through previous studies to the laundry industry. Safety, washability and wastewater quality of EFD-A are evaluated. Three existing commercial detergents(PD1, PD2, LD4) are also evaluated to compare with EFD-A. The safety of detergents is confirmed by the content of optical brightener, VOCs, and arsenic. Washability is evaluated by the difference in reflectance of washed and unwashed artificial soiled fabrics according to detergent concentration, washing temperature, and washing time. TOC is used as the index of assessing the wastewater quality. The results are as follows; EFD-A doesn't contain the optical brighteners, VOCs, and arsenic. The optimal washing conditions for EFD-A are 3 g/L concentration, 40 ℃ washing temperature, and 30 min washing time. The soil removal efficiency is about 71 %, which was similar to or somewhat superior to that of PD1, PD2, and LD4. TOC is 63.5 %, which is about 15 % lower than the discharge limit. Through this study, the developed detergent EFD-A can be used as a safe and eco-friendly detergent for the human body and the environment.

A Study on the Standards of Volatile Organic Compounds in Indoor Air of Office (사무실 실내공기중 휘발성유기화합물의 기준설정에 관한 연구)

  • Kim, Yoon-Shin;Lee, Cheol-Min;Roh, Young-Man;Lee, So-Dam;Sohn, Jong-Ryeul;Kim, Seok-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.413-427
    • /
    • 2006
  • It is necessary to study and develop guidelines for providing comfort and health indoor air quality for office workers since air-tight envelope system of current office building may cause poor indoor air quality. The purpose of this study is to propose guideline for volatile organic compounds in office base on the field study, human health risk assessment and cost-benefit analysis. The field study was conducted to survey the concentrations of volatile organic compounds in indoor air of 69 offices from June to September, 2005 in Seoul and Gyeonggi-do. The rate of excess to guideline of volatile organic compounds in indoor air of new apartment on the Ministry of Environment in Korea(MOE) was surveyed 37.6% for benzene, 6.8% for toluene, and 1.5% for ethylbenzene. As the result of human health risk assessment, mean cancer risk did not exceed 10-6 which is guideline of US.EPA. Also, total hazard index did not exceed 1 which is guideline of US.EPA. Through the cost-benefit analysis of angle on the social-economics to verify the necessary to establish the standards of volatile organic compounds for improvement and development of indoor air quality in office, the present value of benefit was higher than the present value of cost. With the above considerations in mind, it is suggested that the field study for indoor air quality in offices should be expanded and human health risk assessment and cost-benefit analysis be performed th offer scientific data for decision-making of policy for improvement and management of indoor air quality in office.

Emission Characteristics of Volatile Organic Compounds from Air Fresher using Small Emission Chamber (소형방출챔버를 이용한 방향제의 휘발성 유기화합물 방출특성에 관한 연구)

  • Jung, Young-Rim;Park, Hyun-Hee;Oh, Youn-Hee;Kim, Soon-Geun;Sohn, Jong-Ryeul;Kim, Sun-Hwa;Yu, Young-Jae;Bae, Gwi-Nam;Kim, Man-Goo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.183-190
    • /
    • 2011
  • This study investigated the emissions characteristics of air freshener using small emission chamber method. The emission of VOCs from air freshener were determined in the small chambers in the temperature (25, $30({\pm}1)^{\circ}C$), relative humidity ($50{\pm}5%$), ventilation rate (0.3, 0.5, ($0.8({\pm}0.005)/hr$), and sample loading factor ($1.4{\sim}551.0g/m^2$) in this study. The emission tests from air freshener for sample loading factor resulted in TVOC emission rates of $0.7{\sim}64.4mg/m^2{\cdot}h$ after 5 hours. For most target VOCs such as limonene, ${\alpha}$-pinene and linalool, higher temperature and ventilation rate levels exhibited increased emission rates.

Characteristics of Volatile Organic Compounds Emitted from Wood-based Panels (목질제품에서 방출되는 휘발성 유기화합물 특성 연구)

  • Park, Hyun-Ju;Son, Youn-Suk;Lim, Bo-A;Kim, Jo-Chun;Park, Sang-Bum
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.616-623
    • /
    • 2010
  • Recently, interests in indoor air quality (IAQ) have been increased; however, a number of researchers have mainly focused on anthropogenic volatile organic compounds (AVOC) emitted from building materials. Therefore, the properties of natural VOC (NVOC) and anthropogenic VOC (AVOC) emitted from wood-based panels was investigated in this work. VOCs emitted from these panels were sampled through Tenax TA/Cabotrap and analyzed by GC-MS and GC-FID. Comparisons were made concerning TVOC, NVOC, and composition ratios of NVOC. It was revealed that TVOC emission rates of midium density fiber (MDF) were the highest. Besides, it was found that emissions of NVOC from wood-based panels were much higher than those of anthropogenic AVOC except for plywood of Oceania timber. It was also observed that the composition ratio of NVOC emitted from plywood of Pinus radiata was the highest as 65% of TVOC. Major NVOC components were monoterpene compounds such as $\alpha$-pinene, $\beta$-pinene, d-limonene, camphene and $\alpha$-terpinene. It was concluded that the composition rates of VOCs emitted from building materials were clearly different according to the raw materials and manufacturing methods.

USN Environmental Gas Sensing System using Quad Rotor (초소형 비행체 Quad Rotor를 이용한 USN 환경 가스 센싱 시스템)

  • Lee, Byung-Seok;Lee, Joon-Hwa;Kim, Gyu-Sik;Kim, Jo-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.45-46
    • /
    • 2008
  • There are various polluting emissions related to the air quality such as $NO_x$, $CO_2$, CO, VOCs, $O_3$, $SO_2$, $CH_4$, $H_2S$, $NH_3$, etc. We need the system that reduces emission of these environment gases and detects risk factors in modern society. Therefore, if we use the USN(Ubiquitous Sensor Network) technology and a MAV(Micro Air Vehicle) Quad Rotor which can be hovering and moving free for setting up the environment gas sensing system, the realtime measurement on environment gases is facilitated and by extension, in application of traffic watchdog, forest fire surveillance and counter-terrorism efforts, we anticipate making better use of a Quad Rotor.

  • PDF

A Study on Environmental Improvement of Indoor Air Quality in University Dormitory (대학교 기숙사의 실내공기질 환경 개선에 관한 연구)

  • Kim, Ho-Jin;Yang, Jeong-Hoon;Seok, Ho-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1398-1405
    • /
    • 2008
  • As the structure, material and construction of building develop continuously, so the recent residential buildings are being large, high-rise and group. High-rise residential buildings consume a lot of energy on supplying cold and hot water. As well, high-rise residential buildings bring on discomfortable use and unexpected conditions on account of faucet outlet pressure rise and the difference of water supply pressure between top floor and bottom floor. Thus, the purpose of this study is to research on using conditions of cold and hot water supply system through survey and field measurement in high-rise residential buildings and to analyze problems.

  • PDF

A study on contaminant reduction performance of the adsorption protector for construction surface (흡착보양재의 오염물질방출 저감성능에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.714-719
    • /
    • 2008
  • In a domestic construction field, after floor is constructed, protector for construction surface is set up to prevent the surface of the floor being scratched and polluted. However, the problem is that contaminants discharged with the removal of the protector for construction surface exert a bad influence for the indoor air quality. In the research, it tested to the contaminant reduction performance of the adsorption protector for construction surface using powder of charcoal by the alternative proposal of such protectors for construction surface

  • PDF

Analyses of the current market trend and research status of indoor air quality control to develop an electrostatic force-based dust control technique (정전기적 힘을 이용한 실내공기 미세부유먼지 제거 요소기술의 개발을 위한 기술별 시장현황 및 연구 동향 분석)

  • Yoon, Young H.;Joo, Jin-Chul;Ahn, Ho-Sang;Nam, Sook-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6610-6617
    • /
    • 2013
  • This study examined the current and future Indoor Air Quality (IAQ) control device markets and analyzed the recent studies on indoor air pollutantr emoval to develop a new technology for fine dust control. Currently, the mechanical filter technique occupies the bulk of the IAQ control market but the electronic technique is emerging as an alternative to control fine dust efficiently. Among the gaseous VOCs and fine dust particles contaminating the indoor air quality, fine dust particles are more problematic because they threaten human health by penetrating deep into the body and producing secondary contaminants by chemical reaction with VOCs. The electronic IAQ control device using dielectrophoretic and electrostatic forces is a good option for public spaces where many people pass, and at the same time, it needs to consider temperature, humidity, and the particle properties of specific areas to highlight the control efficiency. Electronic-related technology is expected to be used widely in many public/private spaces wherever a dust-free environment is required.