• Title/Summary/Keyword: VOCs analysis

Search Result 328, Processing Time 0.028 seconds

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Characteristics of Atmospheric Concentrations of Volatile Organic Compounds and Aldehydes for Near a Shipyard (조선소 주변지역에서 휘발성유기화합물 및 알데히드류의 농도분포 특성)

  • Park, Jeong-Ho;Suh, Jeong-Min;Han, Seong-Jong
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.767-774
    • /
    • 2008
  • This study was carried out to evaluate the characteristics of atmospheric concentrations of volatile organic compounds(VOCs) and aldehydes for near a large shipyard. Most of the painting work in marine coating is performed indoor and outdoor. Most of the VOCs are emitted to the atmosphere as the paint is applied and cures. The massive scale of a ship makes it difficult to capture the emissions from outdoor painting. The VOCs are an important health and contributors to photochemical smog. The VOCs and aldehydes samples were collected using adsorbent tube and 2,4-DNPH cartridge, and were determined by an automatic thermal desorption coupled with GC/MS and HPLC-UV analysis, respectively. A total of 16 aromatic VOCs and 12 aldehydes of environmental concern were determined. At indoor coating facilities, the most abundant compound among 16 target VOCs appeared to be m,p-xylene, being followed by o-xylene. But most of the aldehydes were extremely lower concentrations. The atmospheric concentration of VOCs, m,p-xylene concentrations were the highest and the mean value were outdoor workshop 11.323 ppb, residental area 5.134 ppb, and green area 2.137 ppb, respectively. However, the most aldehydes were extremely lower concentrations such as formaldehyde, acetaldehyde and non-detection such as iso-valeraldehyde, n-valeraldehyde and o-tolualdehyde.

The Analysis on VOCs That Occurs in Leather Cultural Heritage with SPME (고체상미세추출법(SPME)을 이용한 피혁 재질로부터 발생된 휘발성 유기화합물 분석기술 연구)

  • Chung, Yong-Jae
    • Journal of Conservation Science
    • /
    • v.28 no.2
    • /
    • pp.113-118
    • /
    • 2012
  • Cultural heritages emit volatile organic compounds(VOCs) during degradation as chemical, biological factors. These VOCs in the atmosphere are degradation factors for another materials. But non-destructive organic analysis methods are uncommon, and have difficulties for field application. In this study, solid phase micro-extraction(SPME) and gas chromatography( GC) are carried out for analysis of VOCs which are emitted from leather, and prove SPME field holder's efficiency. I analize leather archival objects at The National Archives of Korea by cross-checking GC and SPME methods. It could be confirmed that the compounds are (E)-2-nonenal, butyl hydroxy toluene emitted itself from leather.

Exposure to PAHs and VOCs in Residents near the Shinpyeong·Jangrim Industrial Complex (신평·장림 산단 인근 주민의 PAHs 및 VOCs 노출)

  • Yoon, Mi-Ra;Jo, HyeJeong;Kim, GeunBae;Chang, JunYoung;Lee, Chul-Woo;Lee, Bo-Eun
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.2
    • /
    • pp.131-143
    • /
    • 2021
  • Objectives: This study aims to investigate the atmospheric concentration of polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) and the urinary concentration of biomarkers in residents near the Shinpyeong·Jangrim Industrial Complex to compare them with those of residents in a control area. Methods: Hazardous air pollutants (PAHs and VOCs) were measured in an exposure area (two sites) and a control area (one site). Urine samples were collected from residents near the industrial complex (184 persons) and residents in the control area (181 persons). Multiple linear regression analysis was used to identify which factors affected the concentration of PAHs and VOCs metabolites. Results: The average atmospheric concentration of PAHs in Shinpyeong-dong and Jangrim-dong was 0.45 and 0.59 ppb for pyrene, 0.15 and 0.16 ppb for benzo[a]pyrene, and 0.29 and 0.35 ppb for dibenz[a,h]anthracene. The average atmospheric concentration of VOCs was 1.10 and 0.99 ppb for benzene, 8.22 and 11.30 ppb for toluene, and 1.91 and 3.05 ppb for ethylbenzene, respectively. The concentrations of PAHs and VOCs in residents near the Shinpyeong·Jangrim Industrial Complex were higher than those of residents in the control area. Geometric means of urinary 2-hydroxyfluorene, 1-hydroxypyrene, methylhippuric acid, and mandelic acid concentrations were 0.45, 0.22, 391.51, and 201.36 ㎍/g creatinine, respectively. Those levels were all significantly higher than those in the control area (p<0.05). In addition, as a result of multiple regression analysis, even after adjusting for potential confounding factors such as gender and smoking, the concentration of metabolites in urine was high in residents near the Shinpyeong·Jangrim Industrial Complex. Conclusion: The results of this study show the possibility of human exposure to VOCs in residents near the Shinpyeong·Jangrim Industrial Complex. Therefore, continuous monitoring of the local community is required for the management of environmental pollutant emissions.

Catalytic Characteristics of Mn-PC for VOCs Combustion (VOCs 연소용 Mn-PC 촉매 특성)

  • Seo, Seong-Gyu;Ma, Zhong-Kun;Liu, Yi;Yoon, Hyung-Sun;Kim, Sang-Chai
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.237-242
    • /
    • 2011
  • In this study, the catalytic activity of Mn-Phthalocyanine (Mn-PC) for VOCs (acetadehyde, propionaldehyde and toluene) combustion was determined. The reaction was carried out in a fixed bed reactor at the temperature range of $200{\sim}380^{\circ}C$. We investigated the physicochemical properties of Mn-PC before and after the pretreatment (air, $450^{\circ}C$, 1 hr, 60 cc/min) by TGA (Thermogravimetric Analyzer), BET (Brunauer Emmett Teller), EA (Elemental Analyzer), XRD (X-ray Diffractometer) and SEM (Scanning Electronic Microscope). By TGA analysis, 88 wt.% mass loss of Mn-PC was found at $419^{\circ}C$. The BET surface area of Mn-PC increased after the pretreatment. The decomposition and combustion of organic components in Mn-PC were observed by EA analysis. We also confirmed that Mn-PC had transformed into a new manganese oxide phase ($Mn_3O_4$) after the pretreatment by XRD analysis. By SEM analysis, many of the micropores generated during the pretreatment were found. The catalytic activity of Mn-PC with the pretreatment for propionaldehyde combustion was higher than that of $Mn_3O_4$ and fresh Mn-PC. It showed the catalytic activity of Mn-PC with the pretreatment for VOCs combustion by the order of toluene < acetadehyde < propionaldehyde.

The Analysis of Volatile Organic Compounds in Water by Using the Purge-and-Trap and the Gas Chromatography/Mass Selective Detector with Modified Indirect Coupling (퍼지-트랩장치와 변형된 간접 결합기를 부착한 기체크로마토그래피/질량 선택성 검출기를 이용한 물중의 휘발성 유기화합물의 분석)

  • 정영자
    • The Korean Journal of Food And Nutrition
    • /
    • v.12 no.2
    • /
    • pp.191-191
    • /
    • 1999
  • A Purge & Trap Concentrator was used to analyze various volatile organic compounds(VOCs) in wat-er. The object of this study was to observe the purge efficiency of 40 VOCs in water according to the change of parameters (purge time drypurge time sample temperature) and to determine the optimum condition for VOCs using the purge & Trap concentrator interfaced with a narrow capillary connected to a gas chromatography/mass spectrometry. The optimum condition of purge and trap is as follows: purge time at 11min drypurge time at 5min sample temperature at 6$0^{\circ}C$ at constant purge flow (40mol/min) constant desorption flow(20ml/min) desorption temperature(2$25^{\circ}C$) and desorption time (1min) At this analytical condition the detection limits of VOCs was in the range of 0.1~0.5$\mu$g/ml and the purge efficiency of each compound was over 70%.

Analysis of 111 VOCs using SPME-GC/MS (SPME-GC/MS에 의한 111종 VOCs 분석법 확립)

  • 김대원;허귀석;유혜경;홍진희
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.344-345
    • /
    • 2001
  • 대기 중에는 ppb 수준의 매우 미량으로 많은 VOC 성분이 존재하고 있어 이를 효과적으로 신속하고 적은 비용으로 분석할 수 있는 분석할 필요성이 커지고 있다. 그러므로, 본 연구에서는 대기중의 VOC성분을 SPME-GC/MS법을 이용하여 효율적으로 분석하기 위한 분석법을 개발하고자 하였다. 유해성이 큰 halocarbon, aromatic, haloaromatic V()Cs 42 종(USEPA TO-14)과, 오존을 유발시키는 오존전구물질 VOCs 53 종, 국내 규제 VOCs 33종, 그리고 악취물질(국내 8종 포함 일본 악취물질 22종)을 전부 포함하는 111종의 VOC를 SPME-GC/MS를 이용하여 신속하게 정성, 정량분석할 수 있는 방법을 확립하고저 하였다. (중략)

  • PDF

Simulated Study on Typical Sources of Volatile Organic Compounds (VOCs) in Indoor Air

  • Dai, Shugui;Bai, Zhipeng;Zhu, Tan;Zhang, Lin
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.745-751
    • /
    • 1995
  • In this paper, several simulated devices were constructed for determining components of organic vapors emitting from decorative materials, daily use chemicals and from common behavior of human beings, such as smoking and cooking. The VOCs were preconcentrated on activated carbon and then desorbed by carbon disulphide. The results were obtained by GC/MS analysis and computer searching. It can be concluded that the categories of the sources and the components of organic vapors in indoor air are very complicated, and different sources of VOCs in indoor air have their own emission characteristics.

  • PDF

A Trend of VOC(Volatile Organic Compound) Control and Patent Analysis on the VOC Control Technical (국내의 VOC 제거 및 회수에 대한 연구동향 및 특허분석)

  • Kim, Pilh-Hwan;Hua, Jin-Mei;Lee, Byung-Ho;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.132-135
    • /
    • 2007
  • VOCs(Volatile Organic Compounds) have been recently enacted by several regulations to the environment since the end of 1990's. So, it need to control emissions of VOCs from industrial cite. VOC controls include all technologies which either collect the VOCs for recovery and reuse or destroy the VOCs. In this study, the VOC control technical trend was searched. Additionally, it was compared to the number of patent along to the year in Korea.

  • PDF

The Study of VOCs Decomposition Characteristics Using UV Photolysis Process (휘발성유기화합물의 광분해 제거 특성에 관한 연구)

  • 서정민;정창훈
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.743-748
    • /
    • 2002
  • UV photolysis process is little known in parts of air pollution treatment, so there are not many applications in field. Therefore we have to do more experiment and study application possibility for treatment of VOCs(Volatile organic compounds). To solve these problems, we have been studying for simultaneous application of this technology. It has shown that concentration of TCE and B.T.X., diameter of reactor and wavelength of lamp have effected on decomposition efficiency. Analysis of TCE and B.T.X. concentration was carried out by GC-FID. A cylinderical reactor consisting of a quartz tube and a centrally located lamp(${\psi}25mm$) was used. The length and diameter of reactor were 1800mm, 75mm. It has shown that the generated ozone concentration goes up 250ppm when using 64watt ozone lamp. When using Photolysis process only, the rates of fractional conversion of each material are TCE 79%, Benzene 65%, Toluene 68%, Xylene 76%. This phenomenon can be rationalized in terms of the different bond energy that indicates how easily VOCs species can be decomposed.